RICE LAKE SCT-4X Series Indicators and Controllers Instruction Manual

June 17, 2024
RICE LAKE

RICE LAKE SCT-4X Series Indicators and Controllers Instruction Manual
RICE LAKE SCT-4X Series Indicators and Controllers

Introduction

Thank you for purchasing this product.

This manual contains web server information for the following SCT-4SX digital weight transmitters:

  • SCT-4X-ETHIP
  • SCT-4X-MODTCP
  • SCT-4X-PRONET

It is recommended that you carefully follow the instructions for programming the weight transmitter; performing actions not indicated in this manual could compromise the functionality of the scale.

Manuals are available from Rice Lake Weighing Systems at www.ricelake.com/manuals Warranty information is available at www.ricelake.com/warranties.

Any problem with the product must be reported to the manufacturer or to the retailer where it was purchased.
Always TURN OFF THE POWER SUPPLY prior to installation or repair action.

Network Connection

Connect the instrument to the network using the available Ethernet ports:
Network Connection

Network Parameters

The IP address, subnet mask and gateway of the instrument can be configured using the procedure indicated in the “Fieldbus configuration” paragraph in the instrument Quick start guide.

In most applications it is sufficient to set the IP address of the instrument in the same class as the PC.

For advanced configurations it is recommended to contact your network administrator.

Web Page Login

Type the IP address of the instrument into a web browser. If the instrument has been configured correctly, the login window will be displayed:
Web Page Login

Enter the password “00000” and sign in.

Once you logged in, it is possible to change the password (Change password).
In case of lost password contact Rice Lake Weighing Systems for recovery.

Only one PC is allowed to access the instrument’s web page at a time, so if you login from a second PC, the first one will be automatically disconnected.

Logging in the instrument web page interrupts the communication with the PLC.

Main Screen

Dependent / independent channels mode (single scale)
Main Screen

Independent Channels Mode (Multi-Scale)
Main Screen

Operating Mode

You can change the operating mode and select the number of active channels / scales from the page below.
After the change you need to log in again to the main page.

Network Configuration

You can change the network parameters and the displayed data format:

  • IP address, Subnet mask, Gateway (enable “Auto config.” for DHCP).
  • Byte order: Big endian / Little endian.
  • Data format : Unsigned integer / Signed integer / Float.
  • Profinet name: up to 16 characters (only SCT-4X-PRONET)
    Network Configuration

Changing the parameters will disconnect the transmitter. To reconnect, you must enter the new IP address in the search bar.

Backup

By clicking on the “Backup” button the browser starts receiving the instrument configuration.
When reception is complete, the “setup.mot” file is automatically downloaded. This file is compatible with the Rice Lake Tools.

Restore

By clicking on the “Restore” button you can select a configuration file to load on the instrument.
WARNING: the configuration file must have “.mot” extension.

Change Password
You can change your login password from this page:
Change Password

Sign Out

Logout from the instrument web page.

Instrument Information

Shows the weight and status information of the scale:
Instrument Information

Zero

Performs zeroing on the instrument.
WARNING: the zero execution takes place only if the necessary conditions are met (zero parameters).

Tare

Performs the tare on the instrument.
To clear an active tare, you must perform a new tare when the scale is empty.

A/D Converter Points

In dep.Ch mode the value displayed is the sum of the active channels.
In ind.Ch mode is displayed the value of the active scale.

Calibration Parameters

Setting of the scale calibration parameters:

Unit Unit of measure (g, kg, t, lb)
Decimals Number of decimal digits (0, 1, 2, 3)
Capacity 1 First range value (or full capacity for single range applications)
Capacity 2 Second range value (not used in single range applications)
Division 1 First range division (1, 2, 5, 10, 20, 50)
Division 2 Second range division (1, 2, 5, 10, 20, 50)

Calibration

  1. Select the number of calibration points from the drop-down menu.
  2. Enter the weight values of the calibration points in the text boxes on the left.
  3. For each point, load the sample weight on the scale and click the corresponding button. The value of ADC points is automatically acquired in the text box on the right. If you know the ADC point value, you can enter it manually.

The weight and ADC point values must be increasing:

Case 1
Calibration

Case 2
Calibration

Save the calibration by clicking WRITE PARAMETERS

If the weight and/or ADC values are not increasing (Case 2), only point 1 will be considered.
If “Check stability” is active, the calibration points are only acquired if the weight is stable.

Theoretical Calibration

  1. Enter the value 0 in the zero mV/V box.
  2. Enter in the mV/V box related to point 1, the cell sensitivity value calculated as shown in the note.
  3. Calculate ADC points by clicking THEOR. CALIB.
    Theoretical Calibration

Commands
Theoretical Calibration

Set point

  1. Set the output function to Gross or Net. (Ref. Quick Start Guide)
  2. Enter the output on/off values in the text boxes.
  3. Save set points by clicking WRITE SETPOINTS

© Rice Lake Weighing Systems Content subject to change without notice.
230 W. Coleman St. • Rice Lake, WI 54868 • USA USA: 800-472-6703 • International: +1-715-234-9171

January 4, 2024 www.ricelake.com PN 221635 Rev A

RICE LAKE Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

RICE LAKE User Manuals

Related Manuals