Schneider Electric XARS8D18p Harmony Standard Remote User Guide
- June 17, 2024
- Schneider Electric
Table of Contents
Schneider Electric XARS8D18p Harmony Standard Remote
SAFETY WARNINGS
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power from all equipment including connected devices, before removing any covers or doors, or installing or removing any accessories, hardware, cables, or wires except under the specific conditions specified in the appropriate hardware guide for this equipment.
- Always use a properly rated voltage sensing device to confirm the power is off where and when indicated.
- Replace and secure all covers, accessories, hardware, cables, and wires and confirm that a proper ground connection exists before applying power to the unit.
- Use only the specified voltage when operating this equipment and any associated products. Failure to follow these instructions will result in death or serious injury.
WARNING
UNINTENDED EQUIPMENT OPERATION
- Use appropriate safety interlocks where personnel and/or equipment hazards exist.
- Install and operate this equipment in an enclosure appropriately rated for its intended environment.
- Do not disassemble, repair, or modify this equipment.
- Do not connect any wiring to unused connections, or to connections designated as Not Connected (N.C.). Failure to follow these instructions can result in death, serious injury, or equipment damage.
It is recommended to charge the battery once a week, for a duration of at least 4 hours.
Electrical equipment should be installed, operated, serviced, and maintained
only by qualified personnel.
No responsibility is assumed by Schneider Electric for any consequences
arising out of the use of this material.
You can download our technical user guide file as well as the eXLhoist
configuration software from our website at www.schneider-electric.com.
WARNING
- UNINTENDED EQUIPMENT OPERATION
- Power line must be wired and protected with fuse or thermal magnetic switch (ex: Schneider-Electric GV2) in compliance with local and national regulatory requirements for the rated current and voltage of the particular equipment.
- Failure to follow these instructions can result in death, serious injury, or equipment damage.
- UNINTENDED EQUIPMENT OPERATION
- Put the remote into STOP mode when not operating the unit to avoid accidental operations of motions push buttons. Failure to follow these instructions can result in death, serious injury, or equipment damage.
Note: You can decrease the “stand-by time out” value using the configuration software tool to reduce the time the remote is in run mode.
MODELS
Main characteristics
WARNING – UNINTENDED EQUIPMENT OPERATION
Install and operate this equipment according to the environmental conditions
described in the operating limits. Failure to follow these instructions can
result in death, serious injury, or equipment damage.
Base station ZARB…
- M12 for external antenna (covered by cap)
- Status LEDs
- M20 for the safeguarding function input wires (covered by cap) 4: 62 pins connector
- M25 for output wires (covered by cable gland)
- M25 for detected applicative alarms input wires (covered by cap)
Specifications | Details | Values |
---|---|---|
ZARB12H | ZARB12W | ZARB18H |
Operating voltage | AC/DC power supply Min…max | 24…48 V AC/DC ± 20% |
AC/DC ± 20% | 24…48 V AC/DC ± 20% | 24…240 V AC/DC ± 20% |
Current consumption (maximum current in onnected or not connected state) | For | |
24V DC | 328 mA | |
For 24V AC | 535 mA | |
For 48V DC | 155 mA | |
For 48V AC | 312 mA | |
For 240V DC | – | 44 mA |
For 240V AC | – | 250 mA |
Operating temperature | For 24…48 V AC/DC power supply | -25…70°C (-13…158°F) |
For 48…130 V AC/DC power supply | – | -25…70°C (-13…158°F) |
(-13…158°F)
For 130…240 V AC/DC power supply| –| -25…50°C (-13…122°F)| –| -25…50°C
(-13…122°F)
Degree of protection| –| IP65 / NEMA 4
Remote control ZART
Specifications | Details | Values |
---|---|---|
ZART8L | ZART8D | ZART12D |
Operating radio range | Free field | > 300 m |
Operating temperature | – | -20…60°C (-4…140°F) |
Operating temperature to charge battery | Office environment | 10…40°C |
(50…104°F)
Degree of protection| –| IP65 / NEMA 4
Charger for remote device
Specifications | Details | Values |
---|---|---|
Operating voltage | – | 110 / 240 VAC |
Operating temperature | Office environment | 0…40°C (32…104°F) |
Degree of protection | – | IP20 |
Wiring
WARNING
- UNINTENDED EQUIPMENT OPERATION
- Use shielded cables wherever specified for inpunts and outputs connections.
- Properly ground the cable shields as indicated in the related documentation.
- Route I/O cables separately from power cables.
- Failure to follow these instructions can result in death, serious injury, or equipment damage.
- Connect the Base Station protective earth ground connection to the machine ground.
- Failure to follow these instructions can result in death, serious injury, or equipment damage.
Base station terminal wiring
Base station ZARB..H – Connector pinout
- A: Pin number
- B: ZARB18H description
- C: ZARB12H description
A| B| C| | A| B| C| | A| B|
C| | A| B| C
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
1| CR_18| –| | 17| CT_16| –| | 33| CT_7| CT_7| | 49| –| –
2| CC_18| –| | 18| CT_15| –| | 34| CC_Y| CC_Y| | 50| –| –
3| CT_18| –| | 19| S2/S3| S2/S3| | 35| CT_2| CT_2| | 51| –| –
4| CT_13| –| | 20| IN3| –| | 36| IN1| –| | 52| –| –
5| CR_17| –| | 21| CC_16| –| | 37| Q0A_1| Q0A_1| | 53| –| –
6| CC_17| –| | 22| CC_15| –| | 38| Q0A_2| Q0A_2| | 54| –| –
7| CT_17| –| | 23| –| –| | 39| CT_3| CT_3| | 55| –| –
8| CC_13| –| | 24| IN2| –| | 40| IN4| –| | 56| –| –
9| CT_14| –| | 25| CT_9| CT_9| | 41| Q0B_1| Q0B_1| | 57| –| –
10| CC_12| CC_12| | 26| CT_8| CT_8| | 42| Q0B_2| Q0B_2| | 58| –| –
11| CT_11| CT_11| | 27| CT_5| CT_5| | 43| CT_1| CT_1| | 59| –| –
12| CC_10| CC_10| | 28| IN_COM| –| | 44| IN5| –| | 60| AC_Neutral|
AC_Neutral
13| CC_14| –| | 29| CC_Z| CC_Z| | 45| PE| PE| | 61| –| –
14| CT_12| CT_12| | 30| CT_6| CT_6| | 46| –| –| | 62| AC_Phase| AC_Phase
15| CC_11| CC_11| | 31| CT_4| CT_4| | 47| CC_X| CC_X| | | |
16| CT_10| CT_10| | 32| IN0| IN0| | 48| IN6| –| | | |
Cable length maximum 50 m (164 ft)
-
DANGER-FIRE HAZARD
Use only the recommended wire sizes for I/O channels and power supplies. Failure to follow these instructions will result in death or serious injury. -
NOTICE-INOPERABLE EQUIPMENT
Do not tighten screw terminals beyond the specified maximum torque (Nm / lb- in.). Failure to follow these instructions can result in equipment damage.
Electrical diagram
Base station ZARB… – Inputs / Outputs
Input / Output| Possible uses ( depending of the
configuration)
---|---
IN0| Feedback loop input
IN1…IN6| Applicative Alarm (only for ZARB18p)
IN7…IN18| Limit Switches (only for ZARB18p)
Q0A (13/14) Q0B (23/24)| Safety relays
Q1…Q9| Motion relays
Q10…Q16 (NO type)| Auxiliary relays (Q13 to Q18 only for ZARB18p)
Q17, Q18 (NO+NC type)| Specific relays (only for ZARB18p)
Base station ZARB… safety relays internal wiring
Base station ZARB18. – Applicative alarms
Input | Description |
---|---|
IN1 | Overload pre-alarm |
IN2 | Overload alarm |
IN3 | Over wind pre-alarm |
IN4 | Over wind alarm |
IN5 | Over speed alarm |
IN6 | Generic alarm |
The ZARB18. base station implements 6 inputs : IN1…IN6 Differents sensors can be connected to these inputs These inputs are dedicated for applicative alarms
Base station ZARB18. wiring diagram for the applicative alarm devices
The IN1 to IN6 input cable length should not exceed 50 m (164 ft)
For E-Stop SIL3, PLe, category 4 refer to the user manual. For the other cases, connect IN0 to S2_S3 signals.
Informs that the feedback loop is opened
Example of wiring for E-Stop and Stop SIL2, PLd, category 3
Example of wiring for E-Stop and Stop SIL2, PLd, category 3, mix drives and contactors
Mechanical installation
Pairing with discovering
(only for ZART..D)
Pairing with configuration software
Diagnostics
Base station ZARB… – Diagnostic LEDs
LED | Color | State | Description |
---|---|---|---|
Status | Green | ON | The remote control system is working properly |
OFF | Base station power OFF or internal fault detected | ||
COM | Yellow | OFF | No communication between the base station and the remote |
control device
Blinking| Communication is established between the base station and the remote
control device
Power| White| OFF| Base station powered OFF
ON| Base station powered ON
Remote device ZARTppD – Diagnostic Display
Exit
Accessories
www.schneider-electric.com/control
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>