amber connect ACT200 Amber Covert T200 GSM GNSS BLE Terminal User Guide

June 17, 2024
amber connect

amber connect ACT200 Amber Covert T200 GSM GNSS BLE Terminal

Product Information

Specifications

  • Technology : ACT200 GSM/GPRS/GNSS/BLUETOOTH
  • GNSS Receiver :
    • Tracking sensitivity : -165 dBm
    • Accuracy: < 3 m
    • Hot start : < 1 s
    • Warm start : < 25 s
    • Cold start : < 35 s
  • Cellular Technology:
    • 2G bands : Quad-band 850 / 900 / 1800 / 1900 MHz
    • Data transfer : GPRS Multi-Slot Class 12 (up to 240 kbps)
    • Data support : GPRS Mobile Station Class B SMS (text/data)
  • Power:
    • Input voltage range: 10-30 V DC with overvoltage protection
    • Back-up battery: 170 mAh Li-Ion battery 3.7 V (0.63 Wh)
    • Internal fuse : 3 A, 125 V
    • Power consumption:
    • At 12V < 6 mA (Ultra Deep Sleep)
    • At 12V < 8 mA (Deep Sleep)
    • At 12V < 11 mA (Online Sleep)
    • At 12V < 20 mA (GPS Sleep)
    • At 12V < 35 mA (nominal with no load)
    • At 12V < 1.5 A Max. (with full Load/Peak)
  • Bluetooth Specification : 4.0 + LE
  • Supported peripherals : Temperature and Humidity sensor,Headset, OBDII dongle, Inateck Barcode Scanner, Universal BLE sensors support
  • Interface:
    • Digital Inputs : 3
    • Digital Outputs : 2
    • Analog Inputs : 2
    • CAN Adapter inputs : 1
    • 1-Wire : Yes
    • GNSS antenna : Internal High Gain
    • GSM antenna : Internal High Gain
    • USB : 2.0 Micro-USB
    • LED indication : 2 status LED lights
    • Memory : 128MB internal flash memory
  • Physical Specification:
    • Dimensions : 65 x 56.6 x 20.6 mm (L x W x H)
    • Weight : 55 g
  • Operating Environment:
    • Operating temperature (without battery): -40°C to +85°C
    • Storage temperature (without battery ): -40°C to +85°C
    • Operating humidity : 5% to 95% non-condensing
    • Ingress Protection Rating : IP41
    • Battery discharge temperature : -20°C to +60°C
  • Features:
    • Sensors : Accelerometer
    • Scenarios : Green Driving, Over Speeding detection, Jamming  detection, GNSS Fuel Counter, DOUT Control Via Call, Excessive Idling detection, Immobilizer, iButton Read Notification, Unplug detection, Towing detection, Crash detection, Auto Geofence, Manual Geo fence, Trip
    • Sleep modes : GPS Sleep, Online Deep Sleep, Deep Sleep, Ultra Deep Sleep
    • SMS GPRS commands : Configuration, Events, DOUT control, Debug
    • Time Synchronization : GPS, NITZ, NTP
    • Fuel monitoring : LLS (Analog), LV-CAN200, ALL-CAN300, OBDII dongle, CAN CONTROL
    • Ignition detection : Digital Input 1, Accelerometer, External Power Voltage, Engine RPM (CAN Adapters, OBDII dongle)
  • Accessories:
    • Bluetooth and analog fuel sensor
    • RFID reader
    • Temperature sensor
    • Bluetooth fuel sensor
    • Analog fuel sensor
    • RFID reader
    • Wired temperature sensor

Product Usage Instructions

Installation

Follow the steps below to install the ACT200 GSM/GNSS/BLE Terminal:

  1. Choose a suitable location for installation.
  2. Ensure that the power supply is within the recommended range (10-30 V DC).
  3. Connect the GNSS antenna and GSM antenna to their respective ports.
  4. Connect any desired peripherals using the available interfaces (e.g., Bluetooth peripherals, temperature sensors, fuel sensors).
  5. Securely mount the terminal in the chosen location.

Powering On/Off

To power on the ACT200 GSM/GNSS/BLE Terminal, connect it to a suitable power source within the recommended voltage range.

To power off the terminal, disconnect it from the power source.

Configuration

The ACT200 GSM/GNSS/BLE Terminal can be configured using SMS commands or through a debugging interface.

Refer to the user manual for detailed instructions on how to configure the terminal.

FAQ

  • Q: What is the recommended operating temperature range for the ACT200 GSM/GNSS/BLE Terminal?
    • A : The recommended operating temperature range is -40°C to +85°C.
  • Q: Can I connect external peripherals to the terminal?
    • A : Yes, you can connect various peripherals such as temperature sensors, fuel sensors, and RFID readers using the available interfaces.

Characteristic

MODULE|
---|---
Name| ACT200
Technology| GSM/GPRS/GNSS/BLUETOOT

GNSS

GNSS GPS, GLONASS, GALILEO, BEIDOU, SBAS, QZSS, DGPS, AGPS
Receiver 33 channel
Tracking sensitivity -165 dBM
Accuracy < 3 m
Hot start < 1 s
Warm start < 25 s
Cold start < 35 s

Cellular

Technology GSM
2G bands Quad-band 850 / 900 / 1800 / 1900 MHz
Data transfer GPRS Multi-Slot Class 12 (up to 240 kbps), GPRS Mobile Station

Class B
Data support| SMS (text/data)

POWER

Input voltage range 10-30 V DC with overvoltage protection
Back-up battery 170 mAh Li-Ion battery 3.7 V (0.63 Wh)
Internal fuse 3 A, 125 V
  At 12V < 6 mA (Ultra Deep Sleep)
  At 12V < 8 mA (Deep Sleep)
Power consumption At 12V < 11 mA (Online Sleep)
  At 12V < 20 mA (GPS Sleep)
  At 12V < 35 mA (nominal with no load) At 12V < 1.5 A Max. (with full

Load/Peak)

BLUETOOTH

Specification 4.0 + LE

Supported peripherals

| Temperature and Humidity sensor, Headset, OBDII dongle, Inateck Barcode Scanner, Universal BLE sensors support

INTERFACE

Digital Inputs 3
Digital Outputs 2
--- ---
Analog Inputs 2
CAN Adapter inputs 1
1-Wire 1
GNSS antenna Internal High Gain
GSM antenna Internal High Gain
USB 2.0 Micro-USB
LED indication 2 status LED lights
Memory 128MB internal flash memory

PHYSICAL SPECIFICATION

Dimensions 65 x 56,6 x 20,6 mm (L x W x H)
Weight 55 g

OPERATING ENVIRONMENT

Operating temperature (without battery) -40 °C to +85 °C

Storage temperature (without

battery)

| ****

-40 °C to +85 °C

Operating humidity| 5% to 95% non-condensing
Ingress Protection Rating| IP41
Battery charge temperature| 0 °C to +45 °C
Battery discharge temperature| -20 °C to +60 °C
Battery storage temperature| -20 °C to +45 °C for 1 month
-20 °C to +35 °C for 6 months

FEATURES

Sensors Accelerometer

Scenarios

| Green Driving, Over Speeding detection, Jamming detection, GNSS Fuel Counter, DOUT Control Via Call, Excessive Idling detection, Immobilizer, iButton Read Notification, Unplug detection, Towing detection, Crash detection, Auto Geofence, Manual Geo fence, Trip
Sleep modes| GPS Sleep, Online Deep Sleep, Deep Sleep, Ultra Deep Sleep
SMS| Configuration, Events, DOUT control, Debug
GPRS commands| Configuration, DOUT control, Debug
Time Synchronization| GPS, NITZ, NTP
Fuel monitoring| LLS (Analog), LV-CAN200, ALL-CAN300, OBDII dongle, CAN- CONTROL


Ignition detection

| Digital Input 1, Accelerometer, External Power Voltage, Engine RPM (CAN Adapters, OBDII dongle)

ACCESSORIES

Bluetooth and analog fuel sensor

RFID reader
Temperature sensor

Bluetooth fuel sensor

Electrical characteristics

Electrical characteristics MIN. TYP. MAX. UNIT

SUPPLY VOLTAGE

Supply Voltage (Recommended Operating Conditions) +10   +30 V

DIGITAL OUTPUT (OPEN DRAINGRADE)

Drain current (Digital Output OFF)     120 µA
Drain current (Digital Output ON, Recommended Operating Conditions)   0.1
0.5 A
Static Drain-Source resistance (Digital Output ON)   400 600

DIGITAL INPUT

Input resistance (DIN1) 47    
Input resistance (DIN2) 51.7    
Input resistance (DIN3) 150    
Input voltage (Recommended Operating Conditions) 0   Supply voltage V
Input Voltage threshold (DIN1)   7.5   V
Input Voltage threshold (DIN2)   2.5   V
Input Voltage threshold (DIN3)   2.5   V

ANALOG INPUT

Input voltage (Recommended Operating Conditions), Range 1 0   +10 V
Input resistance, Range 1   38.45  
Measurement error on 12V, Range 1   0.9   %
Additional error on 12 V, Range 1   108   mV
Measurement error on 30 V, Range 1   0.33   %
Additional error on 30 V, Range 1   88   mV
Input Voltage (Recommended Operating Conditions), Range 2 0   +30 V
Input resistance, Range 2   150  
Measurement error on 12 V, Range 2   0.9   %
Additional error on 12 V, Range 2   108   mV
Measurement error on 30 V, Range 2   0.33   %
Additional error on 30 V, Range 2   88   mV

OUTPUT SUPPLY VOLTAGE 1-WIRE

Supply voltage +4.5   +4.7 V
Output inner resistance   7   Ω
Output current (Uout > 3.0 V)   30   mA
Short circuit current (Uout = 0) 75 mA

Pinout

PIN NUMBER PIN NAME DESCRIPTION
1 VCC (10-30) V DC (+) Power supply (+10-30 V DC).
2 AIN 1 Analog input, channel 1. Input range: 0-30 V DC.
3 AIN 2 / DIN 3 Analog input, channel 2. Input range: 0-30 V DC / Digital

input, channel 3.
4| DIN 2| Digital input, channel 2.
5| DIN 1| Digital input, channel 1.
6| INPUT 6| TX EXT (LVCAN – TX).
7| GND (-)| Ground pin. (10-30) V DC (―)
8| DOUT 1| Digital output, channel 1. Open collector output. Max. 0,5 A DC
9| DOUT 2| Digital output, channel 2. Open collector output. Max. 0,5 A DC
10| 1WIRE POWER| +3,8 V output for 1–Wire devices.
11| 1WIRE DATA| Data for 1–Wire devices.
12| INPUT 5| RX EXT (LVCAN – RX).

Accessories Connection Possibilities

  • 4 IN ports/pin
    • 2 Digital
    • 1 Analog
    • 1 Digital or Analog
  • 2 OUT ports/pins
    • o 2 Digital (for future use)
  • 1 One-wire connection

Installation team must follow the below Accessory connection for efficient working. If installation has to be done with different patterns then please contact your immediate tech support for the possibilities. You can configure these accessories settings in our amber connect fleet management platform.
Fleet Portal > Settings > Vehicle > Safety > Device Input Configuration [This setting available Only to specific device models that supports the accessories]

Warning : These settings should exactly match with the actual accessories connected to the device ports during the installation. If you make any changes on this will result in data reception from accessories to the device. So Kindly make sure you are changing this with proper understanding of which accessory connected to which wire during the installation.

Wiring Scheme

Mounting Recommendations

Mounting Recommendations
Connecting wires

  • a) Wires should be connected while the module is not plugged in.
  • b) Wires should be fastened to stable wires or other non-moving parts. Any heat emitting and/or moving objects should be kept away from the wires.
  • c) There should be no exposed wires. If factory isolation was removed while connecting the wires, the isolation material should be applied.
  • d) If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied and thewires should not be loose.
  • e) Wires cannot be connected to the board computers or control units.

Connecting power source

  • a) Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on the car model, this may happen in 5 to 30-minute period.
  • b) When the module is connected, measure the voltage again to make sure it did not decrease.
  • c) It is recommended to connect to the main power cable in the fuse box.
  • d) 3 A, 125 V external fuse shall be used.

Connecting ignition wire

  • a) Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
  • b) Check if this is not an ACC wire (when key is in the first position, most of thevehicle electronics are available).
  • c) Check if power is still available when you turn off any of vehicle’s devices.
  • d) The ignition  is connected to the ignition relay output. As an alternative, any other relay,which has power output when ignition is on, may be chosen.

Connecting ground wire

  • a) Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
  • b) If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
  • c) For better contact scrub paint from the spot where loop is going to be connected.

LED Indications

BEHAVIOUR MEANING
Permanently switched on GNSS signal is not received
Blinking every second Normal mode, GNSS is working
Off GNSS is turned off because: Device is not working or Device is in Sleep

mode
Blinking fast constantly| Device firmware is being flashed
BEHAVIOUR| MEANING
---|---
Blinking every second| Normal mode
Blinking every two seconds| Sleep mode
Blinking fast for a short time| Modem activity
Off| Device is not working or Device is in Boot mode

Safety information

This message contains information on how to operate safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!

  • The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed voltage range is +10…+30 V DC.
  • To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible. They show the status of the device’s operation.
  • When connecting the 2×6 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.
  • Before unmounting the device from the vehicle, the 2×6 connector must be connected. The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of the EN62368-1 standard. The device is not designed as a navigational device for boats.

Certification and Approvals

  • EACH
  • REACH
  • Declaration of IMEI assignment
  • CE / RED
  • E-Mark
  • RoHS
  • Declaration of device operation temperature

Need help? Contact 24/7 live support!

Scan this QR code to download your App

C 2024 Amber Connect Limited. All rights reserved

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

amber connect User Manuals

Related Manuals