EDiMAX ES-3305P V3 Fast Ethernet Desktop Switch Installation Guide

June 17, 2024
EDIMAX

EDiMAX ES-3305P V3 Fast Ethernet Desktop Switch

EDiMAX-ES-3305P-V3-Fast-Ethernet-Desktop-Switch-
product

Specifications:

  • Model: ES-3305P V3: 5-Port Fast Ethernet Desktop Switch
  • Model: ES-3308P V3: 8-Port Fast Ethernet Desktop Switch

Package Contents:

  • Fast Ethernet Desktop Switch
  • Quick Installation Guide
  • Power Adapter

Top Panel:

5-Port Fast Ethernet Desktop Switch:

  • PWR LED
  • LNK/ACT LEDs 1 – 5

8-Port Fast Ethernet Desktop Switch:

  • PWR LED
  • LNK/ACT LEDs 1 – 8

LED Status:

LED Name Light Status Description
PWR On Switch is on
PWR Off Switch is off
LNK/ACT Off Corresponding port is not connected
LNK/ACT Flashing Corresponding port is active and transferring/receiving

data

Side Panel:

5-Port Fast Ethernet Desktop Switch:

  • RJ-45 Ports 1 – 5
  • 5VDC Power

8-Port Fast Ethernet Desktop Switch:

  • RJ-45 Ports 1 – 4
  • RJ-45 Ports 5 – 8
  • 5VDC Power

Product Usage Instructions:

Connecting to network devices:

The RJ-45 ports on the switch support Auto-MDI/MDI-X which allows both straight-through or cross-over type cables to connect this switch to a workstation or switch.

To connect the switch to a network device:

  1. Connect one end of the network cable to the RJ-45 port on the side panel of the switch.
  2. Connect the other end of the network cable to the RJ-45 port on the network device.
  3. Repeat the above steps for all RJ-45 ports of the switch.

Note: The UTP network cables must comply with EIA/TIA 568 specifications and Category 5 standard for data transmission. The maximum length for a UTP cable segment between the switch and connected devices is 100 meters (300ft).

Once the network cable is connected to both ends and the attached network device is powered on, the green LNK/ACT LED should be lit.

Connecting the power:

To connect the power:

  1. Connect the power adapter to the power connector of the unit.
  2. The green power LED on the front panel should be lit.

Troubleshooting:

  1. Power LED is not lit.

FAQ:

  • Q: What should I do if the Power LED is not lit?
  • A: Please check if the power adapter is properly connected to the unit and if the power source is functioning. If the issue persists, please contact our customer support for further assistance.

ES-3305P V3 / ES-3308P V3

Edimax Technology Co., Ltd.
No.3, Wu-Chuan 3rd Road, Wu-Gu, New Taipei City 24891, Taiwan
Email: support@edimax.com.tw

Edimax Technology Europe B.V.
Fijenhof 2, 5652 AE Eindhoven, The Netherlands
Email: support@edimax.nl

Edimax Computer Company
3350 Scott Blvd., Bldg. 15 Santa Clara, CA 95054, USA
Live Tech Support: 1(800) 652-6776
Email: support@edimax.com

PRODUCT INTRODUCTION

Model:
ES-3305P V3: 5-Port Fast Ethernet Desktop Switch
ES-3308P V3: 8-Port Fast Ethernet Desktop Switch

Package Contents
Before you start using this switch, please check if there is anything missing in the package, and contact your dealer to claim the missing item(s):

  • Fast Ethernet Desktop Switch
  • Quick Installation Guide
  •  Power Adapter

Top Panel

5-Port Fast Ethernet Desktop Switch:

EDiMAX-ES-3305P-V3-Fast-Ethernet-Desktop-Switch-fig-1

8-Port Fast Ethernet Desktop Switch:

EDiMAX-ES-3305P-V3-Fast-Ethernet-Desktop-Switch-fig-2

LED Status

LED Name Light Status Description
PWR On Switch is on
Off Switch is off

LNK/ACT

| On| Corresponding port is connected
Off| Corresponding port is not connected
Flashing| Corresponding port is active and transferring

/receiving data.

Side Panel

EDiMAX-ES-3305P-V3-Fast-Ethernet-Desktop-Switch-fig-3

Operating Environment

This switch must be installed and operated within the limits of the specified operating temperature 0 – 40°C (32 – 104°F) and humidity (10 – 90% non- condensing).

  • Do not place objects on top of the unit.
  • Do not obstruct any vents at the sides of the unit.
  • Do not position the unit to any heating source such as a heater, radiator or in direct exposure to sun.
  • Take care to ensure the unit does not come into contact with water. Consider using a dehumidifier to reduce humidity and prevent moisture entering the unit.

Connecting to network devices

The RJ-45 ports on the switch support Auto-MDI/MDI-X which allows both straight-through or cross-over type cables to connect this switch to a workstation or switch.

  • Connect one end of the network cable to the RJ-45 port on the side panel, and connect the other end of the network cable to the RJ-45 port on the network device. Follow the same procedure to connect all RJ-45 ports of the switch.
  • The UTP network cables must comply with EIA/TIA 568 specifications and Category 5 standard for data transmission. The maximum length for a UTP cable segment between the switch and connected devices is 100 meters (300ft).
    Once the network cable is connected to both ends and the attached network device is powered on, the green LNK/ACT LED should be lit.EDiMAX-ES-3305P-V3
-Fast-Ethernet-Desktop-Switch-fig-4

Connecting the power

Connect the power adapter to the power connector of the unit; the green power LED on the front panel should be lit.

EDiMAX-ES-3305P-V3-Fast-Ethernet-Desktop-Switch-fig-5

  1. Power LED is not lit
    Check if the power cord is properly connected to the external power adapter and the power source. Make sure the DC power jack is firmly plugged into the power socket of the switch.

  2. Link/Activity (LNK/ACT) LED is not lit when connected to devices
    Ensure that the network device attached to the switch is switched on.
    Check the network cable; ensure it is properly connected to the switch and the network device.
    Check the network cable; ensure the UTP cable complied with EIA/TIA 568 and Category 5 specifications.
    [!] Contact your dealer if problems persist.

COPYRIGHT

  • Copyright  Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission from Edimax Technology Co., Ltd.
  • Edimax Technology Co., Ltd. makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties, merchantability, or fitness for any particular purpose. Any software described in this manual is sold or licensed as is. Should the programs prove defective following their purchase, the buyer (and not this company, its distributor, or its dealer) assumes the entire cost of all necessary servicing, repair, and any incidental or consequential damages resulting from any defect in the software. Edimax Technology Co., Ltd. reserves the right to revise this publication and to make changes from time to time in the contents hereof without the obligation to notify any person of such revision or changes.
  • The product you have purchased and the setup screen may appear slightly different from those shown in this QIG. For more information about this product, please refer to the user manual on the CD-ROM. The software and specifications are subject to change without notice. Please visit our website www.edimax.com for updates. All brand and product names mentioned in this manual are trademarks and/or registered trademarks of their respective holders.

Edimax Technology Co., Ltd.
Add: No. 3, Wu-Chuan 3rd Rd., Wu-Ku Industrial Park, New Taipei City, Taiwan Tel: +886-2-77396888
Email: sales@edimax.com.tw

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  1. Reorient or relocate the receiving antenna.
  2. Increase the separation between the equipment and receiver.
  3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  4. Consult the dealer or an experienced radio technician for help.

FCC Caution
This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the authority to operate equipment.

Federal Communications Commission (FCC) Radiation Exposure Statement
This equipment complies with FCC radiation exposure set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 2.5cm (1 inch) during normal operation.

Federal Communications Commission (FCC) RF Exposure Requirements
This EUT is compliance with SAR for general population/uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and had been tested in accordance with the measurement methods and procedures specified in OET Bulletin 65 Supplement C. The equipment version marketed in US is restricted to usage of the channels 1-11 only.

R &TTE Compliance Statement
This equipment complies with all the requirements of DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL of March 9, 1999 on radio equipment and telecommunication terminal equipment and the mutual recognition of their conformity (R&TTE). The R&TTE Directive repeals and replaces in the directive 98/13/EEC
(Telecommunications Terminal Equipment and Satellite Earth Station Equipment) As of April 8, 2000.

Safety
This equipment is designed with the utmost care for the safety of those who install and use it. However, special attention must be paid to the dangers of electric shock and static electricity when working with electrical equipment. All guidelines of this and of the computer manufacture must therefore be allowed at all times to ensure the safe use of the equipment.

EU Countries Intended for Use
The ETSI version of this device is intended for home and office use in Austria, Belgium, Bulgaria, Cyprus, Czech, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Turkey, and United Kingdom. The ETSI version of this device is also authorized for use in EFTA member states: Iceland, Liechtenstein, Norway, and Switzerland.

EU Countries Not Intended for Use
None

EU Declaration of Conformity

This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC, 2009/125/EC, 2006/95/EC, 2011/65/EC.

WEEE Directive & Product Disposal

At the end of its serviceable life, this product should not be treated as household or general waste. It should be handed over to the applicable collection point for the recycling of electrical and electronic equipment, or returned to the supplier for disposal.

Declaration of Conformity

EDiMAX-ES-3305P-V3-Fast-Ethernet-Desktop-Switch-fig-6

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

EDIMAX User Manuals

Related Manuals