ELATION PROFESSIONAL DW CHORUS 12 Variable White LED Batten User Manual

June 17, 2024
ELATION PROFESSIONAL

ELATION PROFESSIONAL DW CHORUS 12 Variable White LED Batten

ELATION-PROFESSIONAL-DW-CHORUS-12-Variable-White-LED-Batten-
PRODUCT

Product Information

Specifications

  • DMX Channel Modes: 1 / 2 / 3 / 4+ / 5+ / 4 / 5 / 7

FAQ

  • Q: Are there any user-serviceable parts inside the DW CHORUS 12TM?
    • A : No, there are no user-serviceable parts inside this unit. Do not attempt any repairs yourself; doing so will void your manufacturer’s warranty.
  • Q: What happens if I modify the fixture or disregard safety instructions?
    • A : Damages resulting from modifications to this fixture and/or the disregard of safety and general user instructions found in this user manual void the manufacturer’s warranty and are not subject to any warranty claims and/or repairs.

©2015 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice.

ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies. ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.

Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com

Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu

DOCUMENT VERSION

Please check www.elationlighting.com for the latest revision/update of this manual.

GENERAL FORMATION

INTRODUCTION

Congratulations, you have just purchased one of the most innovative and reliable lighting fixtures on the market today! The fixture has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact. In the event, damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this unit to your dealer without first contacting customer support at the number listed below. Please do not discard the shipping carton in the trash. Please recycle whenever possible.
BOX CONTENTS

  • (1) powerCON Cable
  • Manual & Warranty Card

CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issues please contact ElationProfessional®.

ELATION SERVICE USA – Monday – Friday 8:00 am to 5:00 pm PST

ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
Voice : +31 45 546 85 30

Fax : +31 45 546 85 96
E-mail : support@elationlighting.eu

WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:http://www.elationlighting.com/Login.aspx to validate your purchase. All returned service items whether under warranty or not, must be freight pre- paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without an R.A. number clearly marked on the outside of the package will be refused and returned at the customer’s expense. You may obtain an R.A. number by contacting customer support.

I M P O R T A N T N O T I C E !
There are no user-serviceable parts inside this unit. Do not attempt any repairs yourself; doing so will void your manufacturer warranty. Damages resulting from modifications to this fixture and/or the disregard of safety and general user instructions found in this user manual void the manufacturer warranty and are not subject to any warranty claims and/or repairs.

LIMITED WARRANTY

A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional® product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional® concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional® factory unless prior written authorization was issued to purchaser by Elation Professional®; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional® will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional®. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional® reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional® in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability touse, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

SAFETY INSTRUCTIONS

  • For proper operation, follow the Installation guidelines described in this manual. Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts (brackets) included with this fixture should be used for installation. Any modifications will void the original manufacturer warranty and increase the risk of damage and/or personal injury.
  • Never look directly into the light source of this fixture to prevent risk of injury to your retina, which may induce blindness. Those suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times.
  • The fan and air inlets must remain clean and never be blocked. Allow approx. 6” (15cm) between this fixture and other devices or a wall for proper cooling.
  • Always disconnect from the main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord.
  • Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If the power cord is damaged, replace it immediately with a new one of similar power rating.

GENERAL GUIDELINES

NEVER OPEN THIS FIXTURE WHILE IN USE!

  • During the initial operation of this fixture, a light smoke or smell may be emitted from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
  • This fixture is a professional lighting effect designed for INDOOR / DRY LOCATIONS ONLY on stage, in nightclubs, theatres, etc.
  • Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while operating, to prevent any fire hazard.
  • The fixture must be installed in a location with adequate ventilation, at least 1.5 feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked.
  • DO NOT attempt installation and/or operation without knowledge how to do so.
  • DO NOT permit operation by persons who are not qualified to operate this type of fixture. Most damages are the result of operations by nonprofessionals.
  • Consistent operational breaks may ensure the fixture will function properly for many years to come.
  • DO NOT shake fixture, avoid brute force when installing and/or operating the fixture.
  • Always install the fixture with an appropriate safety cable. When installing the fixture in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, also be sure the hardware is insert in the pre-arranged screw holes in the bracket of the fixture.
  • Use the original packaging and materials to transport the fixture in for service.
  • DO NOT TOUCH the housing bare hand during its operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before replacing or serving.

FIXTURE  OVERVIEW

  1. RJ45 NET IN
  2. RJ45 NET OUT
  3. powerCON IN
  4. powerCON OUT
  5. LCD Menu Control Display
  6. MODE Button
  7. UP Button
  8. DOWN Button
  9. ENTER Button
  10. 3pin DMX IN
  11. 5pin DMX IN
  12. 3pin DMX OUT
  13. 5pin DMX OUT

FIXTURE INSTALLATION

CAUTIONS

  • For added protection, mount the fixture in areas outside walking paths, seating areas, or in areas were unauthorized personnel might reach the fixture.
  • Ambient operating temperature range for this fixture is 5°F to 113°F (-15°C to 45°C). Do not use the fixture under or above this temperature.
  • Before mounting the fixture to any surface, make sure the installation area can hold a minimum point load of 10 times the weight of the fixture.
  • Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
  • Never stand directly below the device when mounting, removing or servicing.\

POWER LINKING
Max number of units that can be power linked is 11 units @110V and 24 units @240V.
CLAMP MOUNTING
The fixture provides integrated and adjustable rigging brackets. When mounting this fixture to truss make sure to secure appropriately rated clamps to the rigging brackets using a M10 screw fitted through the center hole.

MOUNTING POINTS

  • Overhead mounting requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the device. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
  • Fixture is fully operational in the specific mounting positions as illustrated below.

SAFETY CABLE

ALWAYS USE A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS.

FIXTURE MENU
ON-BOARD SYSTEM MENU
The fixture comes with an easy-to-navigate system menu. The next section will detail the functions of each command in the system menu.
LCD MENU CONTROL PANEL
The control panel (see image below) located on the back of the fixture allows you to access the main menu and make all necessary adjustments to the fixture. During normal operation, pressing MODE button once will access the fixture’s main menu. Once in the main menu you can navigate through the different functions and access the sub-menus with the UP, and DOWN buttons. Once you reach a field that requires adjusting, press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm your setting. You may exit the main menu at any time without making any adjustments by pressing the MODE button.
NOTE : When LCD. Set Key Lock is set to ON, the LCD Menu Control Display will shut OFF and lockout after 30 seconds of no use. Press and hold the MODE button for 10 seconds to unlock the LCD display.

INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:

ELATION© DW CHORUS 12™

DIMMING CURVES
The DimCurve menu allows you to select one of the following preset dimming curves: Standard, Stage, TV, Architec, Theatre, or Default.
(See diagram below for more details)

PIXEL FLIP
Select the desired starting LED Group direction from one of the following modes below via
UP/DOWN buttons and then press ENTER to confirm.

DMX CHANNEL FUNCTIONS AND VALUES

CLEANING AND MAINTENANCE

CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics.

  • Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt/debris accumulation.

  • Never use alcohol, solvents, or ammonia based cleaners.
    MAINTENANCE
    Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.
    Please refer to the following points during routine inspections:

  • A detailed electric check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition and prevent overheating.

  • Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall.

  • Check for any deformations on the housing, color lenses, rigging hardware and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s).

  • Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.

TECHNICAL SPECIFICATIONS
SOURCE
(24) CW + (24) WW 3W Lumi™ LEDs
100,000 Hour Average LED Life*

  • LED Life may vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.

EFFECTS
Strobe and Chase Effects / Variable Dimming Curves
CONTROL / CONNECTIONS

  • (8) DMX Channel Modes
  • 4 Button Control Panel and LCD Menu Display
  • ArtNet™/ KlingNET™ / RDM Protocol Support
  • (2) RJ45 Ports, 3pin and 5pin DMX In/Out
  • powerCON Power In/Out
  • Power Link Up To (11) Units at 120V (24) Units at 230V

SIZE / WEIGHT

  • Length : 12.4” (316mm)
  • Width : 7.0” (177.1mm)
  • Vertical Height : 8.9” (227.1mm)
  • Weight : 12.0 lbs. (5.4kg)

ELECTRICAL / THERMAL

  • AC 110-250V – 50/60Hz

  • 120W Max Power Consumption 5°F to 113°F (-15°C to 45°C)
    APPROVALS / RATINGS

  • CE | IP30

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

PHOTOMETRIC DATA

DIMENSIONAL DRAWINGS

O P T I O N A L   A C C E S S O R I E S

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ELATION PROFESSIONAL User Manuals

Related Manuals