SUPERIOR PUMP 92581 Stainless Steel and Cast Iron Sump Pump Owner’s Manual
- June 15, 2024
- SUPERIOR PUMP
Table of Contents
OWNER’S MANUAL
INSTALLATION AND OPERATION INSTRUCTIONS FOR
SUBMERSIBLE SUMP/EFFLUENT PUMP
Model:
92581, 92571
92731, 92751
92181, 92151
Safety Guidelines
Carefully read, understand and follow all safety instructions in this manual.
This is the safety alert symbol. When you see this symbol, look for one of the
following signal words.
Indicates a hazardous situation which, if not avoided, will result in death or
serious injury.
Indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.
Safety Information
Read these warnings carefully. Know the application and limitations of this
pump.
Failure to follow these warnings could result in serious bodily injury and/or
property damage.
RISK OF ELECTRICAL SHOCK. Disconnect and lockout power supply before removing
old pump or installing or servicing this pump.
RISK OF ELECTRICAL SHOCK. This pump is supplied with a grounding conductor and
grounding type attachment plug. To reduce the risk of electric shock, be
certain that it is connected only to a properly grounded, grounding type
receptacle. For added safety, it is highly recommended to connect this pump to
a GFCI (Ground Fault Circuit Interrupter) outlet. Connect only to a receptacle
that is adequately rated for the voltage and amperage of this pump
The installation of this pump must be in accordance with the National Electric
Code (NEC), Uniform Plumbing Code (UPC), International Plumbing Code (IPC) as
well as all applicable local codes and ordinances.
Do not install this pump in any location classified as hazardous by the
National Electrical Code, ANSI/NFPA70.
Do not use this pump to pump flammable or explosive fluids such as gasoline,
kerosene, etc. Do not use this pump in flammable or explosive environments.
Use only with liquids compatible with pump component materials.
RISK OF ELECTRICAL SHOCK. This pump has not been investigated for use in
swimming pool or marine areas.
RISK OF ELECTRICAL SHOCK. DO NOT use the power cord to remove or lower the
pump into the basin. The cord may pull apart exposing bare wires which could
cause a fire or electrical shock. Use the handle supplied with the pump for
installing and removing the pump from the basin.
Do not run the pump dry. This pump relies on water for cooling. Running the
pump dry can cause the pump to overheat and the possibility of burns to anyone
that handles the pump. Running the pump dry will void the warranty.
Don’t expose pump to freezing temperatures. Discharge . lines exposed to
freezing temperatures should be positioned with a downward slope to prevent
freezing.
Do not use this pump for potable/drinking water. Use only in applications for
which the pump is designed for.
According to the state of California (Prop 65), this product contains
chemicals known to the state of California to cause cancer and birth defects
or other reproductive harm.
DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN. The 3-prong plug must be
inserted into a mating 3-prong grounded receptacle. If the installation does
not have such a receptacle, it must be changed to the proper type, wired and
grounded in accordance with the National Electrical Code and all applicable
local codes and ordinances.
All wiring must be performed by a qualified electrician.
Keep hands clear of suction & discharge openings. To prevent injury, never
insert fingers into pump while it is plugged in.
Sump basins must be vented according to local plumbing codes.
Do not handle this pump with wet hands or while standing on wet or damp
surfaces or in water.
If a flexible discharge hose is used, make sure the pump is secured in the
basin to prevent movement. Failure to secure the pump could result in flooding
from switch malfunction.
This pump motor is equipped with an automatic resetting thermal protector and
may restart unexpectedly.
USE AND INSTALLATION
Always disconnect the power source before attempting to install, service or
perform maintenance on the pump. Failure to do so may result in fatal
electrical shock. Always disconnect the power source before servicing pump.
Your Superior Pump is designed and built to give you reliable performance and
long life. It will pump water automatically for years when properly installed
in the right environment.
REMOVING OLD PUMP. (If necessary)
- Make sure power supply is disconnected.
- After the power is off, remove the old pump. There are many different possible types of installations. It is best to remove all old piping and start over with new piping. Be sure to clean all debris and dirt out of the sump basin before installing your new pump. Be sure to have a grounded 120V AC outlet mounted within 6 ft. of your sump basin. Again, it is highly recommended that a GFCI (ground fault circuit interrupter) outlet be installed in the receptacle box.
NOTICE !
A qualified electrician must perform all wiring.
INSTALLATION (New Pump)
- Set your new pump in the bottom of the sump basin off to one side. The pump should be placed on a solid foundation. Do not place the pump directly on the ground or sandy or rocky surfaces. Sand and small stones may clog or cause damage to your pump.
- Make sure the float switch will swing freely from the bottom to top without coming in contact with the side of the sump basin. Contact with the side of the sump basin may cause the switch to malfunction. See figure below.
- It is highly recommended to install a full flow, swing type check valve (not included) as close to the discharge outlet on the pump as possible. A new check valve will greatly increase the life of your pump. The check valve should be the same size as the pump discharge.
A. Grounded Outlet. A GFCI outlet is strongly recommended.
B. Discharge Pipe
C. Full-flow swing type check valve| D. Sump Basin
E. Position pump so the float switch operates freely without touching the sides of the basin.
---|--- - Connect the pump and check valve together using schedule 40 PVC pipe and fittings. You can also use DWV or ABS pipe, as this is not a pressure installation. Corrugated drain hose is intended for temporary use and should not be used in a permanent installation. Although there are many types of pipe that work adequately for this installation, PVC is recommended.
- Test your installation after you have completed setting up the pump. Plug the cord from the pump into the piggyback plug of the float switch, then plug that into your grounded outlet. The pump should not run at this point. If the pump runs, the switch is stuck in the upright position or the pump is plugged directly into the outlet and not through the piggyback switch plug. Fill the sump basin with water using buckets or a hose. When the switch floats to the upright position, the pump will turn on. The switch will turn off the pump when it reaches the down position. You may adjust the switch to meet your particular needs. Remember the switch must swing freely without touching the sides of the sump basin.
NOTE: This pump has a built in anti-airlock device. Leakage is normal from this device.
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSES | HOW TO CORRECT |
---|---|---|
If the pump does not start or run | Pump is not plugged in, switch or breaker | |
is off | Plug pump in or turn on switch/breaker | |
Check for blown fuses or tripped circuit breakers or tripped GFCI outlets |
Replace fuse, reset breaker, reset GFCI outlet
Float switch is defective| Check and replace if necessary
Motor thermal protector tripped| Allow pump to cool. Pump will reset
Float switch is stuck or obstructed| Remove obstruction or position pump so it
will not become stuck
The pump starts and stops too often| Backflow of water from discharge
hose/pipe| Install or replace check valve
Float switch is defective| Replace float switch
If the pump runs but moves little or no water| Clogged intake screen| Clean or
replace screen
Clogged discharge hose/pipe| Remove clog
Frozen discharge hoselpipe| Allow hose/pipe to thaw
Pump is air laded| Clean out airlock hole with a paper clip or pipe cleaner
Low line voltage| Check wire size and increase if necessary
Check valve is stuck in the closed position| Inspect, repair or replace if
necessary
Check valve is installed backwards| Make sure valve is installed in the
correct direction of flow
Worn, damaged or dogged pump parts| Inspect for wear, damage or clog and dean
or replace if necessary
Discharge head exceeds pump capacity| If pumping height is over 25, the pump
will not move water. See performance chart
Pump does not shut off| Float switch is obstructed or stuck| Remove
obstruction
Defective Float Switch| Replace switch
NOTICE !
Height and/or piping restriction will reduce the pump output performance. See
the performance chart below to insure you have the proper pump for your
application. Whenever possible use the same size or larger pipe as the pump
discharge for optimum performance.
Reducing the pipe size will not harm your pump; it will just reduce the
output.
PERFORMANCES
Output in gallons per minute at listed discharge
Model # | Height above pumping level |
---|---|
0′ | 5′ |
40′ | 45′ |
92581
92571| 75| 70| 64| 57| 49| 40| 31| 21| 11| 0
92731
92751| 80| 75| 69| 61| 55| 45| 38| 25| 16| 2
92181
92151| 86| 81| 75| 68| 61| 52| 43| 31| 20| 3
SPECIFICATIONS
Power supply requirements ……………… 120V, 60 Hz
92581, 92571 Motor …………………………. 1/2 HP, Continuous Duty, Split Capacitor
92731, 92751 Motor …………………………. 3/4 HP, Continuous Duty, Split Capacitor,
Thermally Protected
92181, 92151 Motor …………………………. 1 HP, Continuous Duty, Split Capacitor,
Thermally Protected
Amps …………………………………………….. 7.5
Liquid Temperature Range ……………… 32° F – 120° F (0° C – 49° C)
Circuit Requirements ……………………… 15 amp minimum
Solids Handling ……………………………… 1/2”
Discharge Size ………………………………… 2” NPT
Warranty ……………………………………….. 3 Years
REPLACEMENT PARTS
To order replacement parts call
Ref# | Description | Part # |
---|---|---|
1 | Power Cord | 99102 |
2 | Oil Fill Plug with 0-ring | 99056 |
3 | Pump Housing Cover | 99166 |
4 | Gasket | 99162 |
5 | Shaft Seal | 99157 |
6 | Impeller | 99152 |
7 | Volute/Base | 99165 |
8 | Intake Screen | 99163 |
9 | Vertical Float Switch | 92010 |
10 | Vertical Float Switch Bracket | 99104 |
11 | 2″ MNPT x 1-1/2″ MNPT Adapter | 99250 |
12 | Tethered Float Switch | 92000 |
LIMITED WARRANTY – SUMP PUMPS:
Manufacturer warrants the products specified in this warranty to be free
from defects in material or workmanship for three (3) years from date of
purchase. During the time period and subject to the terms and conditions, the
manufacturer will repair or replace to the original user or consumer any
portion of this product which proves to be defective due to materials or
workmanship. At all times the manufacturer shall have and possess the sole
right and option to determine whether to repair or replace defective
equipment, parts, or components. The manufacturer has the option to inspect
any product returned under warranty to confirm that the warranty applies
before repair or replacement under warranty is approved. This warranty sets
forth the manufacturer’s sole obligation and purchaser’s exclusive remedy for
defective product. Return defective product to the place of purchase for
warranty consideration.
WARRANTY PERIOD – PRODUCTS:
If, within the duration of product use by the original user, this product
proves to be defective due to materials or workmanship, the product shall be
repaired or replaced at the manufacturer’s option, subject to the terms and
conditions set forth in this warranty statement. Proof of purchase is required
for warranty consideration. In the absence of suitable proof of the purchase
date, the effective period of this warranty is 12 months from the product’s
date of manufacture.
LABOR, ETC. COSTS:
The manufacturer shall IN NO EVENT be responsible or liable for the cost of
field labor or other charges incurred by any customer in removing and/or
affixing any product, part, or component thereof.
PRODUCT IMPROVEMENTS:
The manufacturer reserves the right to change or improve its products or
any portions thereof without being obligated to provide such a change or
improvement for units sold and/or shipped prior to such change or improvement.
GENERAL TERMS AND CONDITIONS:
This warranty shall not apply to damage due to acts of God, normal wear and
tear, normal maintenance services and the parts used in connection with such
service, lightning or conditions beyond the control of the manufacturer, nor
shall it apply to products which, in the sole judgment of the manufacturer,
have been subject to negligence, abuse, accident, misapplication, tampering,
alteration; nor due to improper installation, operation, maintenance or
storage; nor to excess of recommended maximums as set forth in the
instructions. Warranty will be VOID if any of the following conditions are
found:
- Product is used for purposes other than those for which it was designed and manufactured
- Product not installed in accordance with applicable codes, ordinances, and good trade practices
- Product connected to voltage other than indicated on nameplate or labels
- Pump exposed to but not limited to the following: sand, gravel, cement, grease, plaster, mud, tar, oil, gasoline, solvents or other abrasive or corrosive substances
- Pump has been used for pumping liquids above 120°F
- Pump allowed to operate dry (liquid supply cut off)
DISCLAIMER:
Any oral statements about the product made by the seller, the manufacturer,
the representatives, or any other parties do not constitute warranties, shall
not be relied upon by the user, and are not part of the contract for sale.
Seller’s and the manufacturers only obligation, and buyer’s only remedy, shall
be the replacement and/or repair by the manufacturer of the product as
described above. NEITHER SELLER NOR THE MANUFACTURER SHALL BE LIABLE FOR ANY
INJURY, LOSS OR DAMAGE, DIRECT, INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT
NOT LIMITED TO, INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS, LOST
SALES, INJURY TO PERSON OR PROPERTY, OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL
LOSS), ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT, AND THE
USER AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT. Before using, the
user shall determine the suitability of the product for his/her intended use,
and user assumes all risk and liability whatsoever in connection therewith.
THE WARRANTY AND REMEDY DESCRIBED IN THIS LIMITED WARRANTY IS AN EXCLUSIVE
WARRANTY AND REMEDY AND IS IN LIEU OF ANY OTHER WARRANTY OR REMEDY, EXPRESSED
OR IMPLIED, WHICH OTHER WARRANTIES AND REMEDIES ARE HEREBY EXPRESSLY EXCLUDED,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, TO THE EXTENT EITHER APPLIES TO A PRODUCT
SHALL BE LIMITED IN DURATION TO THE PERIODS OF THE EXPRESSED WARRANTIES GIVEN
ABOVE.
Some states and countries do not allow the exclusion or limitations on how
long an implied warranty lasts or the exclusion or limitation of incidental or
consequential damages, so the above exclusion or limitations may not apply to
you. This warranty gives you specific legal rights, and you may also have
other rights which vary from state to State.
SS Sump Manual Rev. 1215
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>