ELATION PROFESSIONAL ZCL BAR Z300 IP Versatile IP65 Rated Bar Effect Luminaire with Zoom User Manual

June 6, 2024
ELATION PROFESSIONAL

ELATION | ZCL BAR Z300 IP™
| user manual
ZCL BAR Z300 IP™

user manual

©2021 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non- ELATION brands and product names are trademarks or registered
trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or because of the improper, unsafe, insufficient, and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040 323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 +52 728-282-7070
DOCUMENT VERSION

https://www.elationlighting.com/zcl-bar-z300-ip

Due to additional product features and/or enhancements, an updated version of this document may be available online. Please scan the QR Code with your mobile device or visit www.elationlighting.com for the latest revision/update of this manual, before installation and/or programming.

Date| Document Version| Software Version ≥| DMX
Channel Modes| ****

Notes

---|---|---|---|---
11/22/16| 1| 1U 101

1U 101

| 5 /6 /7 /9 /12 /21 /28| Initial release.
04/06/17| 1.2| N/C| NO CHANGE| Updated Strobe DMX Values. (See highlighted values)
01/10/18| 1.4| N/C| NO CHANGE| Updated version.
09/10/20| 1.6| 1.03| NO CHANGE| Updated primary/secondary
03/16/21| 1.8| N/C| 5 /6 /7 /9 /13 /21 /28| Corrected DMX Channel Mode to 5 /6 /7 /9 /13 /21 /28

GENERAL INFORMATION

INTRODUCTION
This fixture has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP65) where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture and the second digit (Water Protection) indicates the extent of protection against water entering the fixture.
An IP65 rated lighting fixture is one, which has been designed and tested to protect against the ingress of dust (6) and low-pressure water jets from any direction (5).

ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR AN ELECTRICAL SHORT CIRCUIT.

UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect operating condition.
Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this unit to your dealer without first contacting customer support at the number listed below. Please do not discard the shipping carton in the trash. Please recycle whenever possible.

BOX CONTENTS
(1) Glare Shield
(2) Frost Filters
(1) Power Cable
(2) Omega Brackets
CUSTOMER SUPPORT
Contact ELATION Service for any product-related service and support needs.
Also visit forums.elationlighting.com with questions, comments or suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST 323-582-3322 | Fax 323-832-9142 | support@elationlighting.com 
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET +31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu
REPLACEMENT PARTS please visit parts.elationlighting.com

IMPORTANT NOTICE!
THIS FIXTURE CAN ONLY BE SERVICED BY AN AUTHORIZED ELATION-TRAINED PROTEUS BEAM SERVICE TECHNICIAN. THERE ARE NO END USER-SERVICEABLE PARTS, DO NOT ATTEMPT ANY REPAIRS WITHOUT BEING AUTHORIZED; DOING SO WILL VOID THE
MANUFACTURER WARRANTY. DAMAGES OR ANY REPAIRS RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR DISREGARD OF THE SAFETY INSTRUCTIONS AND OPERATION GUIDELINES IN THIS USER MANUAL VOIDS THE MANUFACTURER WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.

LIMITED WARRANTY (USA ONLY)

A. Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability whatsoever for loss and/or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner that Elation Professional concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility
of Elation Professional under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional. All products covered by this warranty were manufactured after January
1, 1990, and bare identifying marks to that effect.
E. Elation Professional reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

WARRANTY RETURNS

All returned service items whether under warranty or not, must be freight pre- paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem, as well as the R.A. number, must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without an R.A. number clearly marked on the outside of the package will be refused and returned at the customer’s expense. You may obtain an R.A. number by contacting customer support.

SAFETY GUIDELINES

To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual.
Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform the installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufactures warranty and increase the risk of damage and/or personal injury.

| PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED
---|---
THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS. 

DO NOT PLUG THE FIXTURE INTO A DIMMER PACK! NEVER OPEN THIS FIXTURE WHILE IN USE! UNPLUG POWER BEFORE SERVICING THE FIXTURE! NEVER TOUCH FIXTURES DURING OPERATION, AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURES!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR AN ELECTRICAL SHORT CIRCUIT.
IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH AS RELOCATION FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, DO NOT POWER THE FIXTURE ON  IMMEDIATELY. INTERNAL CONDENSATION AS A RESULT OF ENVIRONMENTAL TEMPERATURE CHANGE
CAN CAUSE INTERNAL FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS REACHED ROOM TEMPERATURE BEFORE POWERING ON. 

NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK – MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK! 

SAFETY GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 60 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate the fixture if the power cord has become frayed, crimped, damaged and/or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease.
NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of a similar power rating.
DO NOT block any air ventilation slots, these must remain clean and never blocked.
Allow approx. 6” (15cm) between the fixture and other devices or a wall for proper cooling.
When installing fixtures in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, and always attach an appropriately rated safety cable.
ALWAYS disconnect fixtures from the main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, light smoke or smell may emit from the interior of the fixture.
This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
Consistent operational breaks will ensure fixtures will function properly for many years.
ONLY use the original packaging and materials to transport the fixture in for service.

OVERVIEW

SAFETY CABLE RIGGING POINTS
INSTALLATION
FLAMMABLE MATERIAL
WARNING
Keep fixture at least 5.0 ft (1.5m) away from any flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.

**** ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL  SUPPLIERS) TO PREVENT WATER CORROSION AND/OR AN ELECTRICAL SHORT CIRCUIT.

DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations. Before rigging/mounting the fixture to any metal truss/structure or placing the fixture on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture, clamps, cables, and accessories. Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable that meets all local, national, and country codes and regulations. The fixture ambient operating temperature range is 5° to 113°F. (-15° to 45°C) Do not use this fixture outside this temperature range. The fixture should be installed in areas outside walking paths, seating areas, or away from areas were unauthorized personnel might reach the fixture by hand. NEVER stand directly below the fixture when rigging, removing, or servicing. Allow approximately 15 minutes for the fixture to cool down before serving.
CLAMP INSTALLATION
The fixture provides an integrated adjustable yoke with rotating floor stands. When mounting this fixture to truss, (2) Omega Brackets (optional not included) are required. Be sure to secure appropriately rated clamps to the Omega Brackets. Be sure to attach an appropriate Safety Cable to the fixture using the safety cable rigging points integrated in the fixture.
RIGGING
Overhead rigging requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. The fixture is fully operational in the specific mounting positions illustrated below.


SAFETY CABLE

ALWAYS USE A SAFETY CABLE WHENEVER
INSTALLING THIS FIXTURE IN A
SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMPS FAIL.

POWER LINKING
Max number of ZCL BAR Z300 IP™ units power linked together: 2 units @120V | 5 units @240V
**** USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO ZCL BAR Z300 IP AS THE POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!

SYSTEM MENU

The fixture includes an easy-to-navigate system menu control panel display where all necessary setting adjustments are made. (See image below) During normal operation, pressing the MODE button once will access the main menu. Once in the main menu, you can navigate through the different functions and access the sub-menus with the UP and DOWN buttons. Once you reach a field that requires adjusting, press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm your setting. You may exit the main menu at any time without making any adjustments by pressing the MODE/ESC button.
LCD CONTROL PANEL LOCKOUT FEATURE
When the Key Lock menu (Function | LCD. Set | Key Lock) is set to ON (default setting), the LCD control panel display will turn OFF and become LOCKED after non-use. To UNLOCK , press the MODE button.
When the Key Lock menu is set to ON1 mode, follow these steps to UNLOCK the LCD display:

  1. When locked, the display will show LOCKED *****
  2. Press UP, then the display will change to: LOCKED *** (one disappears)
  3. Press DOWN, then the display will change to: LOCKED ** (two disappear)
  4. Press UP, then the display will change to: LOCKED * (three disappear)
  5. Press DOWN, then the display will change to: LOCKED (4 disappear)
  6. Press ENTER, then the display will change to LOCKED and then become unlocked.

INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:

ELATION© ZCL BAR Z300 IP™ |
Features are subject to change without any prior written notice.

ELATION© ZCL BAR Z300 IP™ | S Y S T E M            M E N U

Features are subject to change without any prior written notice.
MAIN MENU| SUB MENU| OPTIONS / VALUES (Default Settings in BOLD)| DESCRIPTION
Set ADDR| Set ADDR| 001 ~ 508| DMX Address Setting
UserMode| | CH:05 , 06, 07, 09, 13, 21, 28| Set DMX Channel / User Mode

Function

| DimCurve| Standard , Stage, TV, Architectural, Theatre| Set Dimmer Curve Mode
No DMX| Hold / Blackout / Program| Function If NO DMX Detected
ZOOM| 000 – 255| Zoom Control for AutoRun Programs
AUTORUN| FQN: 00 -99| Set Number of Times Internal Program Repeats
01.STATIC| CL: R , G, B, RG, GB, RB, RGB, BLAC| Internal Program #1

Select COLOR and Adjust FLASH

F: 00 -99
02. DREAM| SP: 01 -99 | F: 00 -99| Internal Prog#2 Adjust SPEED and FLASH
03.METER| SP: 01 -99 | F: 00 -99| Internal Prog#3 Adjust SPEED and FLASH
04. FADE| SP: 01 -99 | F: 00 -99| Internal Prog#4 Adjust SPEED and FLASH
05. CHANG| SP: 01 -99 | F: 00 -99| Internal Prog#5 Adjust SPEED and FLASH
06.FLOW1| SP: 01 -99 | F: 00 -99| Internal Prog#6 Adjust SPEED and FLASH
07.FLOW2| SP: 01 -99 | F: 00 -99| Internal Prog#7 Adjust SPEED and FLASH
08.FLOW3| SP: 01 -99 | F: 00 -99| Internal Prog#8 Adjust SPEED and FLASH
09.FLOW4| SP: 01 -99 | F: 00 -99| Internal Prog#9 Adjust SPEED and FLASH
10.FLOW5| SP: 01 -99 | F: 00 -99| Internal Prog#10 Adjust SPEED and FLASH
11.FLOW6| SP: 01 -99 | F: 00 -99| Internal Prog#11 Adjust SPEED and FLASH
12.FLOW7| SP: 01 -99 | F: 00 -99| Internal Prog#12 Adjust SPEED and FLASH
Flip| OFF , ON| Set starting LED, see FLIP Section for more info.
Macros| 00 -63| Select Color Macro Value

LCD.Set

| Backlight| 02~60m 05m| LCD Backlight Shut Off Time
Key Lock| ON / ON1, OFF| Control Front Panel Buttons Key Lock
DisFlash| ON / OFF| The display flashes when NO DMX
DORSET| ON / OFF| Restore Factory Settings
TEMP| Fahren / Celsius| Temperature Switch Between F˚/ C˚

Info

|

TimeInfo

| TimerPIN| PIN= 066| Enter PIN to Access Clear Last/Clear Total Menus
Current| XXXX (Hours)| Fixture Run Time From Power ON
TotalTim| XXXX (Hours)| Fixture Total Run Time
Last Clea| XXXX (Hours)| Clear Fixture Last Run Time
TempInfo| xxx°F| XXX / C°| Displays Temperature in Fixture Head
modeling| ELATION| Display Model Name
error in| Error Record 1 ~ Error Record 10| Display 10 Recent Error Messages
Software| 1U ≥V101| 2U ≥V101| Software Versions
Test| Reset. M| ZOOM| Reset of Zoom Motor
Calibrate| Password| Password= 050| Calibration of LEDS (RGBW) and Zoom Motor
Secondary| SECONDARY| SECONDARY Mode

Manual

|

Manual

| ZOOM| 000 – 255| Set Manual Zoom DMX Value
Dimmer| 000 – 255| Set Manual Master Dimmer DMX Value
RED| 000 – 255| Set Manual RED DMX Value
GREEN| 000 – 255| Set Manual GREEN DMX Value
BLUE| 000 – 255| Set Manual BLUE DMX Value
WHITE| 000 – 255| Set Manual WHITE DMX Value
Strobe| 000 – 255| Set Manual STROBE DMX Value

Function – DimCurve

Select desired DIMMER MODE (Standard, Stage, TV, Architectural, Theatre).

Flip
Select the desired starting LED and chase direction from one of the following modes below via UP/DOWN buttons and then press ENTER to confirm. (Default = OFF)

D MX CHANNEL FUNCTIONS AND VALUES

ELATION© ZCL BAR Z300 IP™

DMX Channel Values / Functions Version (28 DMX Channels)


Supports Software Versions: ≥ 1.01

Features are subject to change without any prior written notice.

*Rotation (Clockwise or Counterclockwise) and direction of effects depends on the orientation of the fixture head and Pan/Tilt settings.

MODE / CHANNEL| VALUE| FUNCTION
CH:05| CH:06| CH:07| CH:09| CH:13| CH:21| CH:28


1

| ****

1

| ****

1

| ****

1

| ****

1

| | | ****

0-255

| RED [ALL LEDs]
0 to 100%


2

| ****

2

| ****

2

| ****

2

| ****

2

| | | ****

0-255

| GREEN [ALL LEDs]
0 to 100%


3

| ****

3

| ****

3

| ****

3

| ****

3

| | | ****

0-255

| BLUE [ALL LEDs]
0 to 100%


4

| ****

4

| ****

4

| ****

4

| ****

4

| | | ****

0-255

| WHITE [ALL LEDs]
0 to 100%
| | | | | ****

1

| ****

1

| ****

0-255

| RED [LED #1]
0 to 100%
| | | | | ****

2

| ****

2

| ****

0-255

| GREEN [LED #1]
0 to 100%
| | | | | ****

3

| ****

3

| ****

0-255

| BLUE [LED #1]
0 to 100%
| | | | | ****

4

| ****

4

| ****

0-255

| WHITE [LED #1]
0 to 100%
| | | | | ****

5

| ****

5

| ****

0-255

| RED [LED #2]
0 to 100%
| | | | | ****

6

| ****

6

| ****

0-255

| GREEN [LED #2]
0 to 100%
| | | | | ****

7

| ****

7

| ****

0-255

| BLUE [LED #2]
0 to 100%
| | | | | ****

8

| ****

8

| ****

0-255

| WHITE [LED #2]
0 to 100%
| | | | | ****

9

| ****

9

| ****

0-255

| RED [LED #3]
0 to 100%
| | | | | ****

10

| ****

10

| ****

0-255

| GREEN [LED #3]
0 to 100%
| | | | | ****

11

| ****

11

| ****

0-255

| BLUE [LED #3]
0 to 100%
| | | | | ****

12

| ****

12

| ****

0-255

| WHITE [LED #3]
0 to 100%

Supports Software Versions: ≥ 1.01


Features are subject to change without any prior written notice.

*Rotation (Clockwise or Counterclockwise) and direction of effects depends on orientation of the fixture head and Pan/Tilt settings.

MODE / CHANNEL|

VALUE

| FUNCTION
CH:05| CH:06| CH:07| CH:09| CH:13| CH:21| CH:28
| | | | | ****

13

| ****

13

| ****

0-255

| RED [LED #4]
0 to 100%
| | | | | ****

14

| ****

14

| ****

0-255

| GREEN [LED #4]
0 to 100%
| | | | | ****

15

| ****

15

| ****

0-255

| BLUE [LED #4]
0 to 100%
| | | | | ****

16

| ****

16

| ****

0-255

| WHITE [LED #4]
0 to 100%
| | | | | ****

17

| ****

17

| ****

0-255

| RED [LED #5]
0 to 100%
| | | | | ****

18

| ****

18

| ****

0-255

| GREEN [LED #5]
0 to 100%
| | | | | ****

19

| ****

19

| ****

0-255

| BLUE [LED #5]
0 to 100%
| | | | | ****

20

| ****

20

| ****

0-255

| WHITE [LED #5]
0 to 100%
| | | ****





5

| ****





5

| | ****





21

| | SHUTTER / STROBE
0-31| LED OFF
32-63| LED ON
64-95| Strobe Effect SLOW to FAST
96-127| LED ON
128-159| Pulse Effect in Sequences
160-191| LED ON
192-223| Random Strobe Effect SLOW to FAST
224-255| LED ON
| | | ****

6

| ****

6

| | ****

22

| ****

0-255

| DIMMER INTENSITY
Dimmer 0 to 100%
| | | ****

7

| ****

7

| | ****

23

| ****

0-255

| DIMMER INTENSITY FINE
Dimmer FINE Adjustment

Supports Software Versions: ≥ 1.01


Features are subject to change without any prior written notice.

*Rotation (Clockwise or Counterclockwise) and direction of effects depends on orientation of the fixture head and Pan/Tilt settings.

MODE / CHANNEL| VALUE| FUNCTION
CH:05| CH:06| CH:07| CH:09| CH:13| CH:21| CH:28
| | | | ****





















8

| | ****





















24

| | COLOR PRESETS
0| OFF
1-4| COLOR PRESET 01
5-8| COLOR PRESET 02
9-12| COLOR PRESET 03
13-16| COLOR PRESET 04
17-20| COLOR PRESET 05
21-24| COLOR PRESET 06
25-28| COLOR PRESET 07
29-32| COLOR PRESET 08
33-36| COLOR PRESET 09
37-40| COLOR PRESET 10
41-44| COLOR PRESET 11
45-48| COLOR PRESET 12
49-52| COLOR PRESET 13
53-56| COLOR PRESET 14
57-60| COLOR PRESET 15
61-64| COLOR PRESET 16
65-68| COLOR PRESET 17
69-72| COLOR PRESET 18
73-76| COLOR PRESET 19
77-80| COLOR PRESET 20
81-84| COLOR PRESET 21
85-88| COLOR PRESET 22
89-92| COLOR PRESET 23
93-96| COLOR PRESET 24
97-100| COLOR PRESET 25
101-104| COLOR PRESET 26
105-108| COLOR PRESET 27
109-112| COLOR PRESET 28
113-116| COLOR PRESET 29
117-120| COLOR PRESET 30
121-124| COLOR PRESET 31
125-128| COLOR PRESET 32

Supports Software Versions: ≥ 1.01


Features are subject to change without any prior written notice.

*Rotation (Clockwise or Counterclockwise) and direction of effects depends on orientation of the fixture head and Pan/Tilt settings.

MODE / CHANNEL| VALUE| FUNCTION
CH:05| CH:06| CH:07| CH:09| CH:13| CH:21| CH:28
| | | | ****





















8

| | ****





















24

| | COLOR PRESETS [continued]
129-132| COLOR PRESET 33
133-136| COLOR PRESET 34
137-140| COLOR PRESET 35
141-144| COLOR PRESET 36
145-148| COLOR PRESET 37
149-152| COLOR PRESET 38
153-156| COLOR PRESET 39
157-160| COLOR PRESET 40
161-164| COLOR PRESET 41
165-168| COLOR PRESET 42
169-172| COLOR PRESET 43
173-176| COLOR PRESET 44
177-180| COLOR PRESET 45
181-184| COLOR PRESET 46
185-188| COLOR PRESET 47
189-192| COLOR PRESET 48
193-196| COLOR PRESET 49
197-200| COLOR PRESET 50
201-204| COLOR PRESET 51
205-208| COLOR PRESET 52
209-212| COLOR PRESET 53
213-216| COLOR PRESET 54
217-220| COLOR PRESET 55
221-224| COLOR PRESET 56
225-228| COLOR PRESET 57
229-232| COLOR PRESET 58
233-236| COLOR PRESET 59
237-240| COLOR PRESET 60
241-244| COLOR PRESET 61
245-248| COLOR PRESET 62
249-252| COLOR PRESET 63
253-255| COLOR PRESET 64

Supports Software Versions: ≥ 1.01


Features are subject to change without any prior written notice.

*Rotation (Clockwise or Counterclockwise) and direction of effects depends on the orientation of the fixture head and Pan/Tilt settings.

MODE / CHANNEL

|

VALUE

| FUNCTION
CH:05| CH:06| CH:07| CH:09| CH:13| CH:21| CH:28
| | | | | | ****










25

| | PROGRAM MACROS
0| NO FUNCTION
1-20| PROGRAM MACRO 01
21-40| PROGRAM MACRO 02
41-60| PROGRAM MACRO 03
61-80| PROGRAM MACRO 04
81-100| PROGRAM MACRO 05
101-120| PROGRAM MACRO 06
121-140| PROGRAM MACRO 07
141-160| PROGRAM MACRO 08
161-180| PROGRAM MACRO 09
181-200| PROGRAM MACRO 10
201-230| PROGRAM MACRO 11
231-240| PROGRAM MACRO 12
241-250| PROGRAM MACRO 13
251-255| PROGRAM MACRO 14
| | | | ****

10

| | ****

26

| ****

0-255

| PROGRAM MACRO SPEED
SLOW to FAST Speed
| | | ****

8

| ****

11

| ****

21

| ****

27

| ****

0-255

| ZOOM
Zoom 0% (4 Degrees) to 100% (44 Degrees)
| | | ****




9

| ****




12

| | ****




28

| | DIMMING CURVE MODES
0-20| STANDARD
21-40| STAGE
41-60| TV
61-80| ARCHITECTURAL
81-100| THEATRE
101-255| Default to Unit Setting

CLEANING AND MAINTENANCE

CAUTION
Disconnect power before cleaning or maintenance.

CLEANING
Frequent cleaning is recommended to ensure proper function, optimized light output, and extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky or particularly dirty environments can cause a greater accumulation of dirt on the fixture’s optics.
• Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt/debris accumulation. Never use alcohol, solvents, or ammonia-based cleaners.

MAINTENANCE

Regular inspections are recommended to ensure proper function and extended life.
There are no user-serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections:

  • A detailed electric check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition and prevent overheating.
  • Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out during normal operation resulting in damage or injury as larger parts could fall.
  • Check for any deformations on the housing, color lenses, rigging hardware and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s).
  • Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.

TECHNICAL SPECIFICATIONS

SOURCE
(5) 60W 4-in-1 RGBW LEDs
100,000 Hour Average LED Life
May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
COLOR
RGBW
EFFECTS
RGBW Color Mixing
Full Pixel Control and Pixel Order Flip
4° – 44° Motorized Zoom
64 Color Presets and 12 Unique Program Macros
Electronic Strobe and Selectable Dimming Curves
CONTROL / CONNECTIONS
7 DMX Channel Modes (28 Total Channels)
4 Touch Button Control Panel and LCD Menu Display
RDM (Remote Device Management)
IP rated 5pin DMX and power In/Out

SIZE / WEIGHT
Length: 26.4” (670mm)
Width: 6.2” (157.8mm)
Horizontal Height: 11.7” (297.6mm)
Weight: 43.0 lbs. (19.5 kg)
ELECTRICAL / THERMAL
AC 100-240V – 50/60Hz
390W Max Power Consumption
5F to 113°F (-15°C to 45°C)
APPROVALS / RATINGS
CE | RoHs | IP65
Please Note : Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

OPTIONAL ACCESSORIES

ORDER CODE ITEM
NARROW CLAMP PRO 2” Wrap Around Clamp
8050000053 Omega Bracket (107mm)
NEU088 3 ft. (1m) Power Link Cable
Additional Cable Lengths Available

FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:

  • Reorient or relocate the device.
  • Increase the separation between the device and the receiver.
  • Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help to protect the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELATION PROFESSIONAL User Manuals

Related Manuals