PRESIDIUM OTI All in One Diamond Tester User Guide

June 20, 2024
PRESIDIUM

PRESIDIUM OTI All in One Diamond Tester

PRESIDIUM OTI All in One Diamond Tester

IMPORTANT INFORMATION

  • OTi is intended to be used on polished colorless gemstones that are proportionately cut with a minimum table width of 1.6mm x 1.6mm from Color Grade of D to J only.

  • Our tip is constructed with fibre optic glass and should be handled carefully.

  • For gemstones that have non-ideal cut proportions, inaccuracies may arise due to light leakage. Refer to diagram below.
    Important Information

  • For smaller gemstones or gemstones in an enclosed setting, user should allow gemstone to cool down for 3-5 seconds before retesting.

  • OTi comes with a replacement tip function.

GETTING STARTED

Powering up your OTi

  • Rechargeable Lithium batteries or Power Bank via the provided USB cable is recommended for prolonged usage with portability.
  • If electrical power is preferred, ensure that only Presidium universal USB adaptor is used. Kindly note that the adaptor is not meant for charging of batteries.

Turning on your OTi

  • Press the power button to turn ON the tester.
    Extend the tip outwards by sliding the knob down.

  • Press power button to return to previous page.

INITIALIZE DETECTOR

  • Initializing detector will occur one time only upon turning on.

  • Press the Test icon and tip will heat up.
    To initialize detector, depress tip against round disk on the stone rest.

  • In the event Initialize Detector is unsuccessful, it is possible the tip is defective. User is advised to calibrate and if it does not rectify the problem, a tip replacement is required.

  • To check on the functionality of UV LED, gently depress the tip onto a piece of paper.
    Should you notice a UV LED blue light, this confirms the UV LED is operational. Absence of light indicates a faulty UV LED and need for tip replacement.

  • Upon completion, tip will reheat until “Depress tip to start test” appears. Do not perform any test till heating is completed.

Cleaning the Probe Tip

  • Gently rub the tip in a circular motion against a piece of paper
  • Hold the probe pen with the pen tip forming a right-angle (90-degree) with alcohol wipe.

Cleaning your gemstone prior to testing

  • The gemstone should be clean and dry before testing.

PERFORMING A TEST

  • For testing of loose gemstones, ensure the gemstone is placed securely on the metal stone rest.
  • During the test, the tip must be placed at a right angle or perpendicular to the table of the gemstone for an accurate reading.
  • Depress tip on the table of gemstone.
  • Results will be shown after each test.
  • To start next test, wait for the heating icon to complete or until “Depress tip to start test” appears.

READING TEST RESULTS

The test results are indicated as follows:

Results Description Sound
Diamond The tested gemstone has the characteristic light transmittance
ability of a Type Ia diamond, suggesting that this could be a Natural Diamond

Single Beep
CVD/HPHT/ Type IIa| The tested gemstone has the characteristic light transmittance ability of a Type IIa diamond, suggesting that this could be a CVD/HPHT/Type IIa Diamond| Single Long Beep
Moissanite| The tested gemstone has the characteristic light transmittance ability of a Moissanite, suggesting that this could be a Moissanite| Double Beep
Simulant| The tested gemstone has the characteristic low thermal conductivity compared to diamonds and Moissanite, suggesting that this could be a simulant| No Beep

SHUTTING DOWN

  • Press and hold the power button to initiate shutting down sequence. Retract probe tip from the tester when not in use.

OTHER FUNCTIONS

  • Press the gear icon on the main page, to enter the settings function.
    Settings Function

Calibration

  • Depress tip against round disk on the stone rest and follow the instructions to complete the calibration.

CUSTOMER SUPPORT

www.presidium.com.sg
Presidium Instruments Pte Ltd
Copyright © 2024 Presidium Instruments Pte Ltd
All rights reserved.
Quick Guide
(OTi)
Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>