GOLDENSEA UV UVL 150 Disinfection Unit for Commercial Spaces
- June 6, 2024
- GOLDENSEA UV
Table of Contents
- GOLDENSEA UV UVL 150 Disinfection Unit for Commercial Spaces
- Manual Operation (control panel)
- Remote Control Operation
- Motion Sensor Operation (if the lamp with Motion Sensor)
- Notes
- Suggestion For Disinfection Time
- Warnings
- Product Overview
- Dimensional Drawings
- Installation Instructions
- Replacing The UV Tube
- Troubleshooting Tips
- Features
- Cleaning and Maintenance
- Service
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GOLDENSEA UV UVL 150 Disinfection Unit for Commercial Spaces
Thank you for purchasing a GOLDENSEA UV product. You have acquired a powerful and versatile device. We are confident that you will be satisfied with our excellent products and service. For your own safety, please read this user manual carefully before installing and operating the device.
Voltage Input : AC 100-240V~, 50/60Hz; Power : 150W; Product Size : 491x76x397mm
This UV lamp is only for commercial use in non-residential locations, such as in the hotels, schools, factories, theaters, gymnasiums, restaurants, offices, etc., it shall only be used by professional person. The warning sign as below shall be shown on the way to the fixture during operation.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- This equipment is designed for use with germicidal UV radiation sources and UV radiation can pose a risk of personal injury. Overexposure can result in damage to eyes and bare skin. To reduce the risk of overexposure this equipment must be used by professional person.
- Maintenance and servicing of this UV generating equipment shall be performed by professional person. Service personnel must wear appropriate Personal Protective Equipment (PPE) if the equipment will be in operation during the maintenance or servicing work. Contact the equipment manufacturer for PPE recommendations and guidance.
- When replacing lamps, replace them only with the lamps for which the equipment is marked and intended.
- The use of accessory not recommended by the manufacturer may cause an unsafe condition.
- Do not use this equipment for other than intended use.
- People, pets, and plants should leave the areas when using the disinfection light.
- It should be stored well to avoid accidental damage to the sterilizer and personal injury after the sterilization is finished.
Manual Operation (control panel)
- Close all the doors and windows.
- Plug-in and power on: press the power switch <I/O> to , the power indicator turns on green.
- Select time setting <30 mins>, <60 mins> or <120 mins> by the Time Setting touch key, the touch key indicator light turns on.
- Press the Start touch key, audible alarm starts beeping and red power indicator will flash regularly for 2 minutes. The UV lamp will turn on after the 2 minutes delay when disinfection time is set, the power indicator stays on red.
- Once the disinfection process ends, the power indicator switches to green, an audible alarm sounds. Open the doors and windows to ventilate the disinfected area.
Warning: Don’t look at the disinfection light directly. People, pets and plants should leave the area when using the disinfection light. Ventilate for 30-40 minutes after working.
Remote Control Operation
- Close all the doors and windows.
- Plug-in and power on: press the power switch <I/O> to , the power indicator turns on green.
- Select time setting <30’>, <60’> or <120’> by the Time Setting button on the remote control, the touch key indicator light on the device turns on.
- Press the Start button on the remote control, audible alarm starts beeping and red power indicator on the device will flash regularly for 2 minutes. The UV lamp will turn on after the 2 minutes delay when disinfection time is set, the power indicator stays on red.
- Once the disinfection process ends, the power indicator switches to green, an audible alarm sounds. Open the doors and windows to ventilate the disinfected area.
Note: if the remote control loses pairing with the device, re-do the pairing by pressing the start button on the remote control and switch on the device for 5 seconds. One remote control can be matched with multiple units of the same model.
Motion Sensor Operation (if the lamp with Motion Sensor)
- Turn on the UV lamp, select the disinfection time and start, leave the room, after 2 minutes alarming (Di….Di…Di….), the UV lamps will switch on automatically, the motion sensor will be activated.
- The Motion sensor can ‘see’ through non-metal materials, such as wood board, plastic, fabrics, etc. But the concrete will influence the motion sensor, and the metal board even can stop the detecting ability. So, when the UV Lamps is working, it will turn off when it detects that someone or something moving around within its detecting range even outside the rooms, and it will turn on again when someone or something left.
Note: for safety reason, the UV lamp does not work if the motion sensor is defective.
Notes
- Put the UV lamp on a height of 0cm-400cm to get the best disinfection effect. Please do not put the lamp higher than 400cm, as the Motion Sensor cannot detect perfectly.
- The surface of the lamp should be kept clean.
- When disinfecting the surface of an object with ultraviolet rays, the surface to be irradiated should be directly irradiated within 1 meter of ultraviolet rays, otherwise it’s necessary to increase the irradiation time.
- The lamp is fragile. Please handle it with care.
- According to the latest guideline on the diagnosis and treatment released by the National Health Commission, the virus is sensitive to ultraviolet (UV) light and heat, so UV radiation is a quick and effective way of disinfecting rooms against germs and viruses.
According to the guideline, indoor spaces should be disinfected with UV light with an intensity of over 1.5 watts per square meter. An UV lamp can disinfect objects within one meter for at least half an hour. Longer exposure to radiation is needed when the temperature indoors is below 20°C or above 45°C and relative humidity is over 60%. A room should be ventilated after UV disinfection, and people are suggested to enter the room half an hour later.
Suggestion For Disinfection Time
Area | Power | Disinfection Time |
---|---|---|
40m2 | 150W | 30min |
80m2 | 150W | 60min |
160m2 | 150W | 120min |
Warnings
The UV-C wavelength is 253.7nm, the radiation intensity in 200mm distance is 4422.6 uw/cm
WARNING – RISK OF PERSONAL INJURY
THIS EQUIPMENT IS DESIGNED FOR USE WITH GERMICIDAL LAMPS OR UV SOURCES AND
MUST BE INSTALLED AND USED IN COMPLIANCE WITH COMPETENT TECHNICAL DIRECTIONS
TO PREVENT THE USER’S EYE AND BARE SKIN FROM EXPOSURE TO HARMFUL UV OR OPTICAL
RADIATION. PEOPLE, PETS AND PLANT SHOULD LEAVE THE AREAS WHEN USING THE
DISINFECTION LIGHT.
DO NOT USE THIS EQUIPMENT IN A DWELLING
EYE DAMAGE MAY RESULT FROM DIRECTLY VIEWING THE LIGHT PRODUCED BY THE LAMP IN
THIS EQUIPMENT. ALWAYS TURN OFF LAMP BEFORE SERVICING.
CAUTION: TO REDUCE THE RISK OF FIRE USE ONLY TUV PL-L, 36W,0.44A LAMPS
Suitable for damp locations
UV-C RISK GROUP 3
WARNING: UV-C emitted from this product. Avoid eye and skin exposure to
unshielded product. Follow installation instructions and user manual.
Product Overview
- Handle
- Hanging Hook
- 120 mins – touch key
- 60 mins – touch key
- 30 mins – touch key
- Start – touch key
- Power Indicator
- Power Switch
- Power Cable
- Lamp Tube Safety Catch
- Protective Grid
- UV Tube
- Grid Opening Tabs
- Indicator Lights
Dimensional Drawings
Installation Instructions
Installation of Floor Bracket
Steps:
- Take the device and the floor brackets out of the package.
- Align the screw holes of the floor brackets with the screw holes at the bottom of the device. (Note: feet must face to floor as shown).
- Fix the brackets to device with the 4 screws (M4x10mm) provided.
Wall Mounting
Steps:
- Mount 2 screws (M4) on the wall with a distance of 422mm.
- Mount the device onto the 2 screws using the 2 hooks of the device (as shown).
- Attach a safety cable (not included) between the handle of device and a fixing point on the wall.
(ATTENTION! This step is essential to prevent the device from falling off by accident or misuse)
Installation of Reflector
Steps:
- Pull up the 4 locking tabs (as shown) on the back of the device.
- Install the reflector onto the back of the device. Make sure the reflective (shiny) surface of the reflector is facing the lamp tubes. The rough side of the reflector should be facing away from the lamp tubes.
- Push the 4 locking tabs (as shown) down to lock the reflector into position.
Installation of Tripod Bracket (optional)
Steps:
- Align the screw holes of the tripod bracket with the screw holes at the bottom of the device.
- Fix the tripod bracket to the device with 2 screws (M4x10mm).
- Install your tripod to the tripod bracket with corresponding screws.
Installation of Rotating Bracket (optional)
Steps:
- Align the screw holes of the rotating bracket with the screw holes of both top and bottom of the device as shown.
- Fix the rotating bracket to the device with 4 screws (M4x10mm).
Replacing The UV Tube
To maintain the sterilizing efficacy, the UV tube needs to be replaced after 9,000 hours of use.
Steps:
-
Wait for UV tube to cool down (to avoid scalding) after switching off the device.
-
Pull up the locking tabs ① on both sides of the device, and open the protective grid as shown.
-
Remove the safety catch ② of the UV tube, move the UV tube out of its holder from left to right ③ as shown and take it out.
Note: please follow your local toxic and hazardous waste regulations for lamp disposal. -
Insert the new UV tube into the holder of the device and move the UV tube towards the left until it fits into place correctly and tightly.
Note: direct contact with new UV tube should be avoided as grease from your skin may reduce the efficiency of the UV tube. It is advised to wear protective gloves when handling a new UV tube. -
Fix the safety catch ② back to the UV tube holder.
-
Install the protective grid back onto the device and push down the locking tabs ① on both sides of the device. The device is ready for use now.
Troubleshooting Tips
What to do if the device doesn’t work?
- Ensure the device is plugged into a working wall socket.
- Ensure the plug is wired correctly and terminal well-connected.
- If you still have issues with the device, please contact your local dealer or our customer service for assistance.
How often should the UV tube be replaced?
- The UV tube is the core of the product, it should be replaced after 9000 hours of use to maintain the germicidal efficacy.
- The UV tube is defected if it flashes, please contact your local dealer or our customer service to order a new UV tube. For replacing the UV tube, please refer to the instructions in this user manual.
- After use for a period of time, it is normal to find some black spots on both sides of the UV tube.
The Audio alarm signal and LED indicator signal for this product
Status | Audio Alarm | Power Indicator |
---|---|---|
Standby | – | Green indicator on |
Delayed Start | Beeping for 2 minutes regularly (frequency increase in the |
countdown 10 seconds)
| Red indicator flashing for 2 minutes regularly (frequency increase in the
countdown 10 seconds)
Lamp Strike| UV Lamp on after 15 seconds when the beeping stops| Red indicator
on after beeping stops
Emitting (working)| Single Beeping every 10 seconds| Red indicator on
Motion Detected| Dual beeping every 10 seconds| Red & Green indicators
flashing
End of Cycle| Triple beeping every 10 seconds (in 30 seconds)| Green indicator
on
Features
Light Source
Lamp: TUV PL-L 36W/4P 1CT/25 (PHILIPS)
or
HNS L 36W 2G11 GFT36DL/2G11/SE/OF PURITEC UV-C Germicidal Low Pressure Lamp
(OSRAM)
Extremely long Life: up to 9,000 H
other Features
- Delayed start (2-min delayed start)
- Motion sensor
- Audio alarm
- Visual indicator lights
- 3 disinfection time settings
- Power switch
- Control panel with touch keys
- Through wall remote control
Product Type
Industrial Ultraviolet disinfection light
Weight
Net weight: 3.8 kg
Accessories List:
UV Tube
| |
Included
---|---|---
Remote Control (battery type: CR2025)| |
Included
UV Glasses (protective eyewear)
| | ****
Included
Reflector
| |
Included
---|---|---
Floor Bracket
| |
Included
Warning Sign
| |
Included
Tripod Bracket| ****| Included
Safety Cable
| |
Optional
Rotating Bracket
| |
Optional
UV Irradiance Meter
| | ****
Optional
Cleaning and Maintenance
- To ensure the device remains in good condition and does not fail prematurely, regular maintenance,cleaning and checks are required.
- For cleaning of the device, please use a lint-free cloth.
- To avoid damage to the device, never use detergent or solvents.
- Never spray insecticide towards the device, it can discolor or damaged.
- Should you need any spare parts, please order genuine parts from your local dealer.
Service
For all service needs, please contact your local authorized dealer or GOLDENSEA customer service. Our contact details are:
Email: support@goldenseauv.com
Tel: +86 20 3996 6388
Address: No.109 Haiyong Road, Shiji Town, Panyu Zone, Guangzhou, China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>