ELATION PROFESSIONAL KL FRESNEL 6 CW 150W Warm White LED Light User Manual
- June 4, 2024
- ELATION PROFESSIONAL
Table of Contents
- KL FRESNEL 6 CW 150W Warm White LED Light
- GENERAL INFORMATION
- LIMITED WARRANTY (USA ONLY)
- SAFETY GUIDELINES
- MAINTENANCE GUIDELINES
- FIXTURE OVERVIEW
- INSTALLATION INSTRUCTIONS
- SYSTEM MENU
- MANUAL DIMMING CONTROL
- DMX CHANNEL FUNCTIONS AND VALUES
- SPECIFICATIONS
- FCC STATEMENT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KL FRESNEL 6 CWTM
user manual
KL FRESNEL 6 CW 150W Warm White LED Light
©2021 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non- ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and
all liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax |
www.elationlighting.com |
info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The
Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax |
www.elationlighting.eu |
info@elationlighting.eu
Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma,
Lerma, Mexico 52000 +52 728-282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version
of this document may be available online. Please visit
https://www.elationlighting.eu/en for the latest revision/update of this
manual, before installation and/or programming.
Date| Document Version| Software Version ≥| DMX Channel
Modes| Notes
---|---|---|---|---
03-02-19| 1| 1.03| 1 / 2 / 3 / 4 / 5| Initial release.
10-02-20| 1.1| N/C| NO CHANGE| Updated box contents
10-08-20| 1.2| N/C| NO CHANGE| Updated refresh frequency
10/30/20| 1.3| 1.04| NO CHANGE| Updates specifications and secondary mode
05/26/21| 1.4| N/C| NO CHANGE| Added Standalone instructions to System Menu
section.
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and
thoroughly before attempting to operate this device. These instructions
contain important safety and use information.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton is damaged, carefully inspect the
device for damage, and be sure all accessories necessary to install and
operate the device have arrived intact. In the event damage has been found or
parts are missing, please contact our customer support team for further
instructions. Please do not return this device to your dealer without first
contacting customer support. Please do not discard the shipping carton in the
trash. Please recycle whenever possible.
BOX CONTENTS
Barn Door Gel Frame Power Cable Barn Door Safety Cable (USA Only)
CUSTOMER SUPPORT
Contact ELATION Service for any product related service and support needs.
Also visit forums.elationlighting.com with questions, comments or suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax
323-832-9142 |
support@elationlighting.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET +31 45 546 85
63 | Fax +31 45 546 85 96 |
support@elationlighting.eu
REPLACEMENT PARTS please visit parts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND
ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
LIMITED WARRANTY (USA ONLY)
A. Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual. D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect. E. Elation Professional reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre-
paid and accompany a return authorization (R.A.) number. The R.A. number must
be clearly written on the outside of the return package. A brief description
of the problem as well as the R.A. number must also be written down on a piece
of paper and included in the shipping container. If the unit is under
warranty, you must provide a copy of your proof of purchase invoice. Items
returned without a R.A. number clearly marked on the outside of the package
will be refused and returned at customer’s expense. You may obtain a R.A.
number by contacting customer support.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts (omega brackets) included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufactures warranty and increase the risk of damage and/or personal injury.
| PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED
---|---
| THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND
ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
| DO NOT PLUG FIXTURE INTO A DIMMER PACK! NEVER OPEN THIS FIXTURE WHILE IN
USE! UNPLUG POWER BEFORE SERVICING FIXTURE! NEVER TOUCH FIXTURE DURING
OPERATION, AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
| NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK – MAY INDUCE
BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
| INDOOR / DRY LOCATIONS USE ONLY!
DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and
allow approximately 15 minutes for the fixture to cool down before serving. DO
NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if
any of the power cord connectors are damaged and do not insert into the
fixture securely with ease.
NEVER force a power cord connector into the fixture. If the power cord or any
of its connectors are damaged, replace it immediately with a new one of
similar power rating.
DO NOT block any air ventilation slots.
All fan and air inlets must remain clean and never blocked.
Allow approx. 6″ (15cm) between fixture and other devices or a wall for proper
cooling.
When installing fixture in a suspended environment, always use mounting
hardware that is no less than M10 x 25 mm, and always install fixture with an
appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug end,
never pull out the plug by tugging the wire portion of the cord. During the
initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess
paint in the interior of the casing burning off from the heat associated with
the lamp and will decrease gradually over time. Consistent operational breaks
will ensure fixture will function properly for many years.
ONLY use the original packaging and materials to transport the fixture in
for service.
MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light
output, and an extended life. The frequency of cleaning depends on the
environment in which the fixture operates: damp, smoky or particularly dirty
environments can cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to
avoid dirt/debris accumulation. NEVER use alcohol, solvents, or ammonia-based
cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended
life. There are no user serviceable parts inside this fixture, please refer
all other service issues to an authorized Elation service technician. Should
you need any spare parts, please order genuine parts from your local Elation
dealer.
Please refer to the following points during routine inspections: A detailed
electric check by an approved electrical engineer every three months, to make
sure the circuit contacts are in good condition and prevent overheating. Be
sure all screws and fasteners are securely tightened at all times. Lose screws
may fall out during normal operation resulting in damage or injury as larger
parts could fall. Check for any deformations on the housing, color lenses,
rigging hardware, and rigging points (ceiling, suspension, trussing).
Deformations in the housing could allow for dust to enter into the fixture.
Damaged rigging points or unsecured rigging could cause the fixture to fall
and seriously injure a person(s). Electric power supply cables must not show
any damage, material fatigue, or sediments. NEVER remove the ground prong from
the power cable.
FIXTURE OVERVIEW
1. Fuse
2. Power In
3. Power Out
4. 5pin DMX In
5. 5pin DMX Out| 6. 3pin DMX Out
7. 3pin DMX In
8. USB Software Update Port
9. OLED Control Menu Display
10. MODE Button| 11. UP Button
12. DOWN Button
13. ENTER Button
14. Manual Dimming Control Knob
15. Manual Zoom Control Knob
---|---|---
INSTALLATION INSTRUCTIONS
FLAMMABLE MATERIAL WARNING
Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or
pyrotechnics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or
installations.
USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER
CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS
FIXTURE. CHECK SILK SCREEN FOR MAX AMPS.
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country
commercial electrical and construction codes and regulations.
Before rigging/mounting a single fixture or multiple interconnected fixtures
for custom matrix designs to any metal truss/structure or placing the
fixture(s) on any surface, a professional equipment installer MUST be
consulted to determine if the metal truss/structure or surface is properly
certified to safely hold the combined weight of the fixture(s), clamps,
cables, and accessories.
Fixture ambient operating temperature range is 14° to 113°F. (-10° to 45°C) Do
not use the fixture under or above this temperature.
Fixture(s) should be installed in areas outside walking paths, seating areas,
or away from areas were unauthorized personnel might reach the fixture by
hand.
NEVER stand directly below the fixture(s) when rigging, removing or servicing. Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable that meets all local, national, and country codes and regulations. Allow approximately 15 minutes for the fixture to cool down before serving.
GEL FRAME AND BARN DOOR INSTALLATION
The fixture has 2 slots on the front to hold the GEL FRAME and BARN DOOR.
The first smaller slot is for the GEL FRAME and the second larger slot is
for the BARN DOOR. The fixture also has a top lock that secures these
accessories to the fixture.
Secure the included mini SAFETY CABLE to the BARN DOOR and the top lock.
- Lift up lock on top of fixture and insert GEL FRAME into the first slot closest to fixture.
- Insert BARN DOOR into the second slot.
- Lower the lock on top of the fixture to secure both the GEL FRAME and BARN DOOR.
- Secure the included mini SAFETY CABLE to the BARN DOOR and top lock.
CLAMP INSTALLATION
When mounting the fixture to truss, be sure to secure an appropriately rated
professional grade rigging clamp to the fixture using an M10 screw fitted
through one of the 3 holes of the yoke bracket. The fixture provides a built-
in rigging point for a SAFETY CABLE. Be sure to only use the designated
rigging point for the safety cable and never secure a safety cable to a
carrying handle.
SAFETY CABLE RIGGING POINT
RIGGING
Overhead rigging requires extensive experience, including amongst others
calculating working load limits, installation material being used, and
periodic safety inspection of all installation material and the fixture. If
you lack these qualifications, do not attempt the installation yourself.
Improper installation can result in bodily injury. Fixture is fully
operational in the specific mounting positions illustrated below.
SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE
WHENEVER INSTALLING THIS FIXTURE
IN A SUSPENDED ENVIRONMENT TO
ENSURE THE FIXTURE WILL NOT DROP IF
THE CLAMP FAILS.
SYSTEM MENU
The fixture includes an easy to navigate system menu. The control panel (see image below) located on the side of the fixture provides access to the main system menu and is where all necessary system adjustments are made to the fixture. During normal operation, pressing MODE button once will access the fixture’s main menu. Once in the main menu you can navigate through the different functions and access the sub-menus with the UP and DOWN buttons. Once you reach a field that requires adjusting, press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm your setting. You may exit the main menu at any time without making any adjustments by pressing the MODE button.
NOTE: To access the LCD Menu Control Display when locked, press and hold the MODE button for 3 seconds. The LCD Menu Control Display will shut OFF automatically about 1 minute from the last button press.
STANDALONE
Press the MODE button to access the fixture’s main menu. Use the UP and DOWN
buttons to navigate to DMX Settings and press the ENTER button. Navigate to No
DMX Status and press the ENTER button. Navigate to Standalone and press the
ENTER button.
ELATION KL FRESNEL 6 CW
S Y S T E M M E N U
Supports Software Versions: ≥ 1.04
Features subject to change without notice.
MAIN
MENU| SUB MENU| OPTIONS / VALUES (Default Settings in BOLD)| DESCRIPTION
Address| Address| 001 – xxx| Set DMX Address Setting
UserMode| User Mode| Dimmer / Dimmer 16bit / 3CH / Standard / Extended| Set
DMX Channel / User Mode
Function| Status| Lost Dmx| Hold / Black| Function If NO DMX Detected
LCD. Set| Display| ON / OFF| OLED Display Screen Saver Mode When ON 30
g es off after seconds.
ONLY WHEN DMX IS CONNECTED.
Key Lock| ON / OFF| Control Front Panel Buttons Key Lock
Flash| ON / OFF| Display flashes when NO DMX
Invert| ON / OFF| Flip LCD Display 180°
Temp. C/F| C / F| Temperature Switch Between C7 F”
Dim Mode| Standard, Stage, TV, Arctitec, Theatre. Stage2. 0.0s. 0.1s, 0.2s,
0.3s, 0.4s. 0.5s, 0.6s, 0.7s, 0.8s, 0.9s, 1.0s, 1.5s, 2.0s. 3.0s. 4.0s, 5.0s,
6.0s, 7.0s, 8.0s. 9.0s, 10.0s| Set Dimmer Mode
Disp. Set| ADDR, Disp.CH. Secondry| Set Information to Display on LCD
Fan. Set| Led Fan I Auto / High / Low| Set LED Fan Speed
Dim Curve| Linear / Square / INV-Square / S-Curve| Set Dimmer Curve Mode
Frequen| 900kHz. 1000k11z. 1100kHz. 1200kHz. 1300kHz. 1400kHz.
1500kHz, 2500kHz, 4000kHz. 5000kHz. 10kHz. 15kHz. 20kHz. 25kHz| Set LED
Refresh Frequency
USB_Data| ON. OFF| Software Update Port – Contact Service
Primary| ON. OFF|
DFSE| ON, OFF| Restore Factory Settings
Info| Timelnfo| Current| 000 (Hours)| Fixture Run Time From Power ON
Total| 000 (Hours)| Fixture Total Run Time
Last| 000 (Hours)| Clear Fixture Last Run Time
Password| PIN= 050| Enter PIN to Access Clear Last. Menu
Clew| ON / OFF| Reset Fixture Last Run Time
Tempinfo| Led Temp| 000 C /F| Temperature of LED
Err. Info| Error Record 1 – Error Reco d 10| Display 10 Recent Error Messages
Modellnf| KL F6 CW| Display Model Name
Software| Software| V1.03| Software Version (Greater than or Equal to)
Test| ManCtrl| Dimmer| 000 – 255| Manual Control Functions
Strobe| 000 – 255
DIMMER CURVE MODES – Dim Curve
Select desired DIMMER MODE (Standard, Stage, TV, Architectural, Theatre,
Stage2).
MANUAL DIMMING CONTROL
- FEATURE IS DISABLED WHEN DMX INPUT CABLE IS CONNECTED TO FIXTURE! TO USE MANUAL DIMMING KNOB, DISCONNECT DMX CABLE IF CONNECTED.
Follow steps below to enable manual DIMMING control knob.
- Access fixture system menu navigating to Test menu then access ManCtrl sub menu.
Test| Reset.M| Zoom| Reset Zoom Motor
---|---|---|---
Calibrat| PassWord| Password=050| Calibrate Zoom Motor
(PSWD Required to Access)
Zoom| 000-255
ManCtrl| Dimmer, Zoom, Strobe| Manual Control Functions
NOTE: To access the LCD Menu Control Display when locked/OFF, press and hold the MODE button for 3 seconds.
- Select Stobe menu, set to value of 255 (LED ON), then exit fixture system menu.
- Push DIMMING knob to unlock, rotate to desired level, push knob again to lock.
Repeat this process each time a dimmer adjustment is desired.
LCD DISPLAY
DMX CHANNEL FUNCTIONS AND VALUES
ELATION KL FRESNEL 6 CW
DMX Channel Values / Functions (5 DMX Channels)
Supports Software Versions: 1.03
Features subject to change without notice.
MODE/CHANNEL | VALUE | FUNCTION |
---|---|---|
Damns | Deemer | |
IBM | 3CH | Stomata |
1 | 1 | 1 |
Dimmer 0 to 100%
000-255
| | | 2| 2| | DIMMER INTENSITY FINE
Dmsuncnt FINE Adjustment
000-255
| | | | 3| | SHUTTER STROBE
LED OFF
000-031
032-063| LED ON
064-035| Strobe Effect SLOW to FAST
096-127| LED ON
129-169| Rube Ellett In SLOW b FAST
160-191| LED ON
192-223| Randeen Strata Eflect SLOW to FAST
224-255| LED ON
| | | | 4| 1:101420|
| Standwd
021-040| Stage
041-060| 1V
061-090| Arthaecttrat
0111-11:0| Theatre
101-120| Stage 2
121| Drone Delay Tone 0.0 secant
122| Marna Delay line 0.1 seconds
123| Dimmer Delay Tyne 0.2 seconds
124| Owner Delay Tyne 0.3 seconds
125| Deaner Delay Tine 0.4 seconds
126| Dimmer Delay Time 0.5 seconds
127| Orme. Delay line 0.6 seconds
129| Dime Delay line 0.7 second;
129| Dime. Delay Tine OS seconds
130| Dimmer Delay Tyne 0.9 seconds
131| Dime Delay Tome 1.0 seconds
132| Deemer Delay Tine 1.5 seconds
133| Owner Delay Tyne 2.0 seconds
134| Dimmer Delay Time 3.0 seconds
135| Omer Delay Tana 4.0 seconds
136| Dimmer Delay Tyne 6.0 seconds
137| Dime. Delay line 6.0 seconds
139| Dinner Delay Tine 7.0 seconds
139| Drente Delay line 00 seconds
140| Dame, Delay These 9.0 seconds
141| Dimmer Delay Tene 10.0 seconds
142-265| Default
| | | | 5| | LED REFRESH RATE | DIMMER CURVES
Hold selected DMX value for 5 seconds to set LED Refresh Rate.
000-100| IDLE
101-105| 900 kHz
106-110| 1000 kHz
111-115| 1100 kHz
116-120| 1200 kHz
121-125| 1300 kHz
126-130| 1400 kHz
131-135| 1500 kHz
136-140| 2500 kHz
141-145| 4000 kHz
146-150| 5000 kHz
151-155| 10,000 kHz
156-160| 15,000 kHz
161-165| 20,000 kHz
166-170| 25,000 kHz
171-200| IDLE
201-210| DIMMER CURVE LINEAR (DEFAULT)
211-220| DIMMER CURVE SQUARE
221-230| DIMMER CURVE INVERSE SQUARE
231-240| DIMMER CURVE S-CURVE
241-255| IDLE
SPECIFICATIONS
SOURCE
150W Cool White LED Engine 5,600K, 97CRI
50,000 Hour Average LED Life
May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling),
Control and Dimming.
PHOTOMETRIC DATA
8,500+ Total Lumen Output 9,269 LUX 861 FC @ 9.8′ (3m) (Min. Zoom) 2,334 LUX
217 FC @ 9.8′ (3m) (Max. Zoom)
Zoom Range 16° – 39° Beam Angle 16.1° – 38° Field Angle 39.1° – 53.9°
EFFECTS
Manual Zoom
Electronic Dimmer and Strobe Variable 16-bit Dimming Modes and Curves
COLOR
5,600K Cool White LED
CONTROL / CONNECTIONS
Manual and DMX Controlled Dimmer and Shutter
Dimmer and Zoom Rotary Dials (5) DMX Channel Modes (1 / 2 / 3 / 4 / 5) 4
Button Control Panel LCD Menu Display RDM (Remote Device Management) 3/5pin
DMX and IP65 Locking Power Cable In/Out With Wired Digital Communication
Network
SIZE / WEIGHT
Length: 13.5″ (344mm) Width: 10.75″ (273mm) Vertical Height: 15.47″ (393mm)
Weight: 18.5 lbs. (8.4kg)
ELECTRICAL / THERMAL
AC 100-240V – 50/60Hz 180W Max Power Consumption 5°F to 113°F (-15°C to 45°C)
Power Linking: 6Pcs @ 110V / 14Pcs @ 240V
INCLUDED ITEMS
Gel Frame and Rotating Barn Doors IP65 Locking Power Cable Barndoor safety
cable (USA Only)
APPROVALS / RATINGS
CE | cETLus | IP30
IP30
Specifications and improvements in the design of this unit and this manual
subject to change without written notice.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part
15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
device uses and can radiate radio frequency energy and, if not installed and
used in accordance with the included instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this device does
cause harmful interference to radio or television reception, which can be
determined by turning the device off and on, the user is encouraged to try to
correct the interference by one or more of the following methods:
- Reorient or relocate the device.
- Increase the separation between the device and the receiver.
- Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
DIMENSIONAL DRAWINGS
Specifications and improvements in the design of this unit and this manual subject to change without written notice
References
- WorldSite ist nun VIVANET
- Topics | Elation Lighting Forums
- Elation Professional EUROPE - Professional Lighting Products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>