Product Information

Specifications

  • SKU: 10138 23000
  • Watts: 40W
  • Lumens: 4000Lm
  • CRI: >80
  • DF: Beam Angle
  • Input Power: AC 220-240V, 50/60 Hz
  • IP Rating: IP20
  • Dimension: 1200x50x58mm

Introduction & Warranty

This LED Linear Light comes with a warranty. Please read the following instructions carefully before installation to ensure proper usage and to maintain the warranty.

Warning

  1. Please make sure to turn off the power before starting the installation.
  2. Installation must be performed by a qualified electrician.
  3. The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
  4. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similarly qualified person to avoid a hazard.
  5. For Indoor use only.

This marking indicates that this product should not be disposed of with other household wastes. Caution, risk of electric shock.

Mounting with Hangers

For suspension mounting, it is necessary to use special suspension kits (not included in the kit, purchased separately). Follow these steps:

  1. Fasten the bracket to the ceiling with screws.
  2. Install the carabiner on the back of the luminaire.
  3. Pass the cable through the hanger bracket.
  4. Pass the cable through the hole in the suspension cover.
  5. Connect the lamp to the 220V network.
  6. Installation completed!

Maintenance

Maintenance must be carried out by qualified authorized personnel with the appropriate authority to do so.

Safety Instructions

Installation and maintenance of the luminaire should only be carried out when the power supply is switched off. Do not use light sources with a power exceeding that indicated in the luminaire marking.

Disposal

The luminaire does not contain expensive or toxic materials requiring special disposal. Disposal is carried out in the usual way through recycling companies.

Product Usage Instructions

Installation Diagram

Refer to the provided installation diagram for guidance on mounting methods.

Mounting Methods

  1. Surface Installation (Surface Mounting Kit Included)
  2. Hanging (Accessories not included, to be purchased separately)
  3. Recessed (Accessories not included, to be purchased separately)

Wiring Diagram – Linking Diagram (up to 1000W)

Note: When linking 2 or more fixtures, the power cable needs to be plugged only on 1 end.

Scheme of Collecting Fixtures into the System using
Fixtures-Connectors

  • L SHAPE CONNECTION DIAGRAM
  • X SHAPE CONNECTION DIAGRAM
  • A SHAPE CONNECTION DIAGRAM

NOTE: Be careful! The power input must be one for the whole system!

FAQ

  • Q: Can I replace the light source in this luminaire?
  • A: No, the light source is not replaceable. When it reaches its end of life, the whole luminaire should be replaced.
  • Q: What is the IP rating of this product?
  • A: This product has an IP rating of IP20, which means it is protected against solid objects larger than 12mm and does not provide any protection against water.
  • Q: Can I use this product outdoors?
  • A: No, this product is designed for indoor use only.

TECHNICAL DATA

SKU

|

WATTS

|

LUMENS

|

CRI

|

DF

| BEAM ANGLE|

INPUT POWER

| IP RATING|

DIMENSION

---|---|---|---|---|---|---|---|---
10138

23000

|

40W

|

4000Lm

|

80

|

0.9

|

120°

| AC:220-240V 50/60 Hz|

IP20

|

1200x50x58mm

INTRODUCTION &WARRANTY

Thank you for selecting and buying the V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any other queries, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at your best. The warranty is valid for 3 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 hours of Daily operation. Usage of the product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only.

WARNING

  1. Please make sure to turn off the power before starting the installation.
  2. Installation must be performed by a qualified electrician.
  3. The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
  4. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similarly qualified person to avoid a hazard.
  5. For Indoor use only

V-TAC-10138-23000-LED-Linear-Light-FIG-1

  • This marking indicates that this product should not be disposed of with other household wastes.
  • Caution, risk of electric shock.

Mounting with hangers

  • For suspension mounting, it is necessary to use special suspension kits (not included in the kit purchased separately).
  • Fasten the bracket to the ceiling with screws, and install the carabiner on the back of the luminaire. Pass the cable through the hanger bracket. Pass the cable through the hole in the suspension cover, then connect the lamp to the 220V network. Installationcompleted!

Maintenance

  • Maintenance must be carried out by qualified authorized personnel with the appropriate authority to do so.

Safety instructions

  • Installa on and maintenance of the luminaire should only be carried out when the power supply is switched off.
  • Do not use light sources with a power exceeding that indicated in the luminaire marking.

Disposal

  • The luminaire does not contain expensive or toxic materials requiring special disposal.
  • Disposal is carried out in the usual way through recycling companies.

INSTALLATION DIAGRAM

MOUNTING METHODS

  1. Surface Installation (Surface Mounting Kit Included)V-TAC-10138-23000-LED-Linear-Light-FIG-4
  2. Hanging (Accessories not included to be purchased separately)V-TAC-10138-23000-LED-Linear-Light-FIG-5
  3. Recessed (Accessories not included to be purchased separately)

V-TAC-10138-23000-LED-Linear-Light-FIG-6

Wiring Diagram

V-TAC-10138-23000-LED-Linear-Light-FIG-7

LinkingDiagram (Upto 1000W)

V-TAC-10138-23000-LED-Linear-Light-FIG-8

Note: When linking 2 or more fixtures, the power cable needs to be plugged only on 1end.

V-TAC-10138-23000-LED-Linear-Light-FIG-9

Scheme of collecting fixtures “into the system” using fixtures-connectors

  • L SHAPE CONNECTION DIAGRAMV-TAC-10138-23000-LED-Linear-Light-FIG-10
  • X SHAPE CONNECTION DIAGRAMV-TAC-10138-23000-LED-Linear-Light-FIG-11
  • A SHAPE CONNECTION DIAGRAM

V-TAC-10138-23000-LED-Linear-Light-FIG-12

NOTE: Be careful! The power input must be one for the whole system!

Scheme for collecting fixtures “in a square”

V-TAC-10138-23000-LED-Linear-Light-FIG-13

Documents / Resources

| V-TAC 10138 23000 LED Linear Light [pdf] Instruction Manual
10138 23000 LED Linear Light, 10138 23000, LED Linear Light, Linear Light, Light
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals