30-202050 Complete Pool Controller
NEW
MODEL
2015
FAN
LESS
PORTABLE
COLOR
DISPLAY
(TFT)
UPGRADE
POSSIBLE
WORLDWIDE
REMOTE
CONTROL
UP TO
4
PARAMETERS
WIFI and
MODBUS
FILTRATION
AND LIGHT
CONTROLS
INSTALLATION GUIDE
1 DESCRIPTION
Station is a complete pool controller which doses pool chemicals
in order to maintain the pool water in perfect
conditions. The base product controls the temperature,
filtration periods, pool lighting and 4 additional
relays. The base product is upgraded by adding the
measurement and control of up to 4 water parameters.
The management of the additional parameters can also
be upgraded post-sales via “upgrade kits”.
Electronic box
- Main connection 220 V
- ON/OFF switch
- Fuse for device and cell 3.15 A
- Fuse relays 3.15 A
Electrical connections of the electronic box
- An “Installer Menu” does exist for advanced functions. If you are an authorized installer, please ask your provider for the installers/service manual.
2 SYSTEM INSTALLATION
A Filtration pump timer *
B Silex / glass / diatom filter
C Recirculation pump
1 Electronic box
4 pH probe (optional – for models with pH control)
5 redox probe
(optional – for models with redoX control)
6 Conductivity probe
(optional – for models with conductivity control)
8 Acid dosing pump
(optional – for models with pH control)
9 Acid injector
(optional – for models with pH control)
10 Hydrochloric acid container
(optional, for models with pH control, not supplied with unit)
15 Other pool equipment
16 Module RF or RF/WIFI or WIFI
17 Free chlorine control
3 FUNCTIONING OF THE SYSTEM
Main screen
3.1 Measures
3.2 Filtration
2.1 Filtration modes
2.2 Manual: Filtration can be switched ON and OFF manually.
2.3 Automatic (or with timer): In this mode the filtration switches ON/OFF
according to 3 timers. The timers always work on daily bases.
2.4 Smart: This mode uses, as a basis, the automatic or timer mode, with its
3 intervals of filtration, but adjusting the filtration time in function of
the water temperature. For that reason 2 parameters of temperature are
provided: The maximum temperature, from which on the filtration times will be
the ones from the timer setting. The minimum temperature: below this value the
filtration time will be reduced to 5 minutes, which is the minimum working
time. Between these 2 temperatures the filtration times will climb linearly.
There is an option to activate the antifreeze mode in which the filtration
will start if the water temperature is below 2° C.
2.5 Timed heating with option of climatization: This mode acts equally to the
automatic mode, but besides it includes the option to work on a relay to
control the temperature. The desired temperature is set in this menu, and the
system works with a hysteresis of 1 degree (example: the setting temperature
is 23° C, the system will activate itself when the temperature goes below 22°
C and will not stop before it passes 23° C).
Clima OFF: The heating only works within the set filtration periods.
Clima ON: Keeps the filtration working when the filtration period is finished
if the water temperature is below the setting temperature. When the setting
temperature is reached the filtration and the heating will stop and will not
switch on till the next programmed filtration period.
2.6 Intelligent*: In this mode the user has 2 working parameters to guaranty
the desired water temperature with a minimum of filtration hours: You select
the desired water temperature and the minimum filtration time (minimum of 2
hours and maximum of 24 hours). The device divides the selected “minimum
filtration time” in 12 fragments which start up every 2 hours. If one of these
fragments finishes, without the temperature reaching the desired level, the
filtration/heating continues until the desired temperature is accomplished. In
order to keep the filtration-electricity-cost to a minimum, this additional
filtration time is subtracted from the following fragments of the “minimum
filtration time”. The first 10 minutes of each fragment will not be
subtracted. Example (see diagram): Minimum temperature = 28°C and minimum
filtration time = 12 hours.
2.7 Filter cleaning mode (and pool cleaning by suction): Use the up/down keys to activate or deactivate the filtration pump. The device will inform about the elapsed time from the moment of activation or deactivation. Follow the instructions of the filter manufacturer to execute an adequate filter cleaning.
- Note: Modes only visible if the option to use temperature and/or heating probe is activated in the “Installer Menu”.
4.3 Lighting
3.1 Lighting
3.2 Manual mode (ON/OFF).
3.3 Automatic mode: Shuts lights ON/OFF according to a timer. The timers can
be configured with a frequency: Daily; Every 2 days; Every 3 days; Every 4
days; Every 5 days; Weekly; Every 2 weeks; Every 3 weeks; Every 4 weeks.
3.4 Auxiliary relays
4.1 Auxiliary relays
4.2 It is possible to control up to 4 extra auxiliary relays (water features,
fountains, automatic irrigation systems, built-in cleaning systems, air pumps
for spas, garden lighting, etc.). This menu displays the relays which are
still available on your device and allow configuration.
4.3 Manual mode (ON/OFF).
4.4 Automatic mode: ON/Off according to a timer. The timers can be configured
with a frequency: Daily; Every 2 days; Every 3 days; Every 4 days; Every 5
days; Weekly; Every 2 weeks; Every 3 weeks; Every 4 weeks.
4.5 Timer mode: Working time is programmed in minutes. Each time the key on the front panel in relation to the relay is pressed, it will start up for the time programmed. This function is recommended for the timing of air pumps for spas.
3.5 Settings
5.3
Setting of preferred language.
5.5 Setting of day and current time.
5.7 Setting of the intensity of the display lighting (0-100%) and programming
its ON and OFF time.
3.5 Settings (continuation)
5.9 Sound: Programming of the system to emit sound for the functions: Keyboard
(keys); Notices (pop-up message); Alarms (working alarm); Filtration (start of
the filtration).
5.11 Password: Allows to protect the access to the user´s menu by activating a
password. To enter your password press a combination of 5 keys and the system
will memorize. If you forget the password, there is a “master password”. Ask
you installer/provider.
5.12 Time info: The system memorizes the operation times of the different
modules and they are displayed on the screen.
5.13 System info: Information about the available software version of the TFT
display and the power module. It also shows the ID node which is necessary for
the configuration of the WIFI connection of the system.
4 SYSTEMS WITH redoX CONTROL
The redoX value advises us of the oxidation/reduction potential and is used to determine the level of water sterilization. The parameters or setpoints are the minimum/maximum accepted redoX levels before the titanium cell is connected/disconnected. Adjusting the ideal redoX level (setpoint) is the last step in the Station start up sequence. To find the optimum redoX levels for your pool follow these steps:
- Connect the pool filtration system.
- Add chlorine to the pool till a level of 1-1,5 ppm is achieved (approx. 1-1,5 gr/ m3 of water). pH levels should be between 7,2 – 7,5.
- After 30 min. test the free chlorine levels in the pool (manual test kit DPD1) if the free chlorine level is between 0,8 – 1,0 ppm. Look at the redoX screen and memorize this level as the setpoint to CONNECT / DISCONNECT the chlorine pump.
- The next day check free chlorine levels (manual test kit DPD1) and redoX. Raise / lower setpoint if necessary.
- Remember to check the redoX set-point every 2-3 month and/or if the water parameters change (pH / temperature / conductivity).
5 MAINTENANCE
First days of maintenance
During the first 10-15 days your pool system will require more attention and the following care:
- Make sure the pH remains on the ideal level (7,2 – 7,5). If the pH is unusually unstable and uses a lot of acid, check the alkalinity (recommended levels between 80 y 120 ppm).
- The pool must be vacuumed and the skimmers cleaned whenever necessary to ensure perfect water conditions.
General maintenance
- DOSING PUMPS: Check regularly to ensure that the container contains liquid to prevent the dosing pump of running dry. The dosing pump requires maintenance (SEE INSTRUCTIONS ON BOX).
- pH PROBES / redoX / CONDUCTIVITY: Probes must be cleaned whenever necessary (check every 5-6 months). To clean the probe insert in distilled water (clear liquid). After each cleaning the probes must be calibrated. Also: the probes should never dry out and must be kept wet if stored (when emptying the pool for winterizing, make sure to store the measuring head in water).
Fortnightly checks
FREE CHLORINE 1,0 – 2,0 ppm
pH: 7,2 – 7,5
Monthly checks
TOTAL ALKALINITY (TAC) pH: 80 – 120 ppm
CYANURIC ACID: 30 – 50 ppm
6 TROUBLESHOOTING
Blank display
- Check if ON/OFF switch is illuminated.
- Check the connection wire between display and motherboard.
- Check fuse of the device 3.15 A – it could have tripped due to overload.
- Check the power supply 110V/60Hz – 230V/50Hz.
- If problem persists contact TECHNICAL SERVICE
White flakes in the water
- The water is excessively hard and it is unbalanced.
- Balance the water and check the cell, proceeding to clean it if necessary.
- Put 1 small bag of flocculant in the skimmer and recirculate 24 hours.
Alarm AL3 and pH dosing pump stopped
- The maximum dosing time (standard 200 min.) is accomplished and the acid dosing pump stops in order to avoid the acidification of the water.
- To delete the message and to restart the metering press ESC ( ). Do the following verifications in order to preclude errors on the device: Verify if the pH probe reading is correct (if not, calibrate the probe or substitute it with a new one); Verify if the acid/base deposit is full and if the dosing pump is working correctly; Verify the variable speed of the dosing pump.
WARNING
Keep chemical levels in pool as instructed in this manual.
EARTHING
All metallic components in the pool such as lamps, ladders, heat exchangers,
drains or similar elements within 3 m from the pool (10 feet) must be
connected to an earth below 37 Ohms. If using heat exchangers, we recommend
them to be made of titanium.
SECURITY
To avoid accidents, children should not handle this product unless supervised
by an adult. Children should be supervised at all times when in or near a spa,
pool or jacuzzi.