BLUEDIAMOND 230 volt P-Series Models MaxiBlue and Reservoir 208V User Guide

June 17, 2024
BLUEDIAMOND

BLUEDIAMOND 230 volt P-Series Models MaxiBlue and Reservoir 208V

Product Information

  • Specifications:
    • Manufacturer: Charles Austen Pumps
    • Product: BlueDiamond Condensate Removal Pump
    • Warranty: 3 years from the date of purchase
    • Tolerance: Can tolerate some dust and sludge
    • Operational Voltage: 230 volts

Product Usage Instructions

  • Warranty:
    • The BlueDiamond Pumps come with a 3-year warranty from the delivery date.
    • The warranty covers any failure within the specified period under normal usage. To avail of the warranty, ensure that the installation of the pump conforms to the provided instructions and specifications.
    • Any modifications to the unit will void the warranty. Charles Austen Pumps reserves the right to alter specifications without prior notification.
  • Cleaning & Maintenance:
    • If the reservoir or sensors of the BlueDiamond pump require cleaning, use warm soapy water.
    • Take care not to damage the sensors during cleaning. After any cleaning or maintenance work, carry out an operational test before using the pump.
  • Installation Instructions:
    • 230 volt M-Series models:
    • Before installation, verify the pump voltage.
    • The installation requires removing the black plug from the pump power cable. For CITY MULTI indoor units, identify if it has a CN4F or CN31 drain safety connector and wire accordingly.
    • If these connectors are not present, wire according to the M-series diagram.
    • CITY MULTI 230 volt models:
    • Before installation, verify the pump voltage.
    • The installation requires removing the black plug from the pump power cable.
    • CITY MULTI indoor units will either have a CN4F or CN31 drain safety connector.
    • Identify which is present and wire according to the provided diagram. If the connectors are not present, wire according to the M-series diagram.
    • 230 volt P-Series models:
    • Before installation, verify the pump voltage.
    • The installation requires removing the black plug from the pump power cable.
    • Current P-Series indoor units will either have a CN4F or CN31 drain safety connector. Identify which is present and wire according to the provided diagram.
    • If the connectors are not present, wire according to the M-series diagram.
    • MXZ Branch Box Applications with Blue Diamond Pump:
    • For MXZ-4C36NAHZ, MXZ-5C42NAHZU1, MXZ-8C48NAHZU1, MXZ-8C48NAU1, and MXZ8C60NA models, the Blue Diamond pumps have a delay on the NC alarm circuit that may cause a 7102 capacity error when S1 is broken.
    • Breaking S1 is the proper way to install the pump and safety switch according to the original instructions.

FAQs

  • Q: How long is the warranty for BlueDiamond Pumps?
    • A: The warranty for BlueDiamond Pumps is 3 years from the date of purchase under normal usage.
  • Q: What should I do if the pump requires cleaning?
    • A: If the reservoir or sensors of the pump require cleaning, use warm soapy water. Take care not to damage the sensors. After cleaning or maintenance, perform an operational test before using the pump.
  • Q: Can I modify the unit without voiding the warranty?
    • A: No, any modifications to the unit will immediately void the warranty.
  • Q: How can I contact Charles Austen Pumps for support?
    • A: You can contact Charles Austen Pumps at +1 770 831 1122 or reach them at 4850 Golden Parkway, Suite B, 409, Buford, GA30518, USA. You can also email them at info@bluediamondpumps.com or visit their website at www.bluediamondpumps.com.

WARRANTY

  • BlueDiamond Pumps are manufactured under Charles Austen Pumps strict quality control system.
  • In the unlikely event of failure within the 3 years from the date of purchase under normal usage, Charles Austen Pumps will repair the item free of charge subject to the following conditions: 3-year warranty from delivery date in conjunction with our conditions of sale.
  • Charles Austen Pumps will decline any responsibility if the installation of the pump does not conform to our instructions and specifications.
  • Any modifications to the unit will immediately void the warranty.
  • We reserve the right to alter any specifications without prior notifications These pumps have been evaluated for use with water freezing and 82°F.

CLEANING & MAINTENACE

  • BlueDiamond condensate removal pumps will tolerate some dust and sludge.
  • However, if the reservoir or sensors require cleaning, use warm soapy water and take care to not damage the sensors.
  • After any cleaning or maintenance work, carry out an operational test before using the pump.

WARRANTY

  • 230 volt M-Series models Verify pump voltage before installation
    • The installation below will require the black plug to be removed from the pump power cable.
  • 230 volt P-Series models Verify pump voltage before installation
    • The installation below will require the black plug to be removed from the pump power cable.
    • Current P-Series indoor units will either have a CN4F or CN31 drain safety connector.
    • Identify which is present and wire according to the diagram below.
    • Older models may not have one of these connectors. If this is the case, wire according to the M-series diagram.
  • CITY MULTI 230 volt models Verify pump voltage before installation
    • The installation below will require the black plug to be removed from the pump power cable.
    • CITY MULTI indoor units will either have a CN4F or CN31 drain safety connector.
    • Identify which is present and wire according to the diagram below.
    • Older models may not have one of these connectors. If this is the case, wire according to the M-series diagram.
    • Please refer to full installation instructions for full product safety details.
    • If the pump is to be operated on 110v Vac please use the following wiring diagram.

MXZ Branch Box Applications with Blue Diamond Pump

  • Application Models: MXZ-4C36NAHZ, MXZ-5C42NAHZU1, MXZ-8C48NAHZU1, MXZ-8C48NAU1 and MXZ8C60NA.

Occurring Condition

  • The Blue Diamond pumps have a delay on the NC alarm circuit that will cause a 7102 capacity error when S1 is broken.
  • According to original instructions breaking S1 is the proper way to install the pump and safety switch.
  • To avoid the error condition it will be necessary to break the coil thermistor of the indoor unit with the NC Alarm circuit of the Blue Diamond pump using butt splice connectors.
  • On the indoor unit wiring diagram the coil thermistors will be designated as either RT12 or TH2. (See Below)
  • Recommended inlet & outlet tubing is to be 1/4″ ID PVC braided tube.
  • All connections should be securely fastened and airtight.
  • The maximum internal diameter of the suction and discharge lines should not exceed 3/8″ in areas that are dependent on the pump (ie none gravity).

CONTACT US

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals