GROW K216 Fingerprint Control board User Manual

May 15, 2024
GROW

GROW K216 Fingerprint Control board

GROW-K216-Fingerprint-Control-board-product

Product Information

Specifications

  • Power supply: DC10V-30V
  • Output Relay Max. current: 10A
  • Fingerprint Module: MX 1.0-6P
  • Fingerprint Module Standby current: 6mADC12V
  • Fingerprint capacity: 300 pieces

FAQ

  • Q: Where can I find more information about the product?

Product Usage Instructions

SET Button

  1. Press the SET button shortly to enter the register state. The indicator light will flash fast. Press the SET button two times for each fingerprint. Register successful when hearing music. You can continuously register fingerprints while in the register state. If you do not need to add more fingerprints, wait for 8 seconds. (Fingerprint capacity is 100 pieces when pressing the SET button, and the registered fingerprints are stored in database 01).
  2. To reset to factory default, press and hold the SET button until you hear a long beep and music, indicating successful initialization operation.

Remote Control

  1. When the red indicator is lighted, it means the system is in programming state. Hearing music means operation successful. The default password is “123456” with a password length of 6 numbers.
  2. To change the password, press password1new passwordnew password#.
  3. To register a fingerprint, press password2DD#, where DD ranges from 00 to 02 (00, 01, and 02 refer to three different fingerprint databases). Each database can store up to 100 fingerprints. Exit fingerprint registration state by pressing the button or waiting for 10 seconds.
  4. To empty a fingerprint, press password3*password#.

Product Overview

GROW-K216-Fingerprint-Control-board-fig-1

Technical parameter

  • P1: Power supply: DC10V–30V
  • P2: Output:Relay(Max. current: 10A)
  • P3: MX 1.0-6P Fingerprint Module
  • P4: MX 1.25-6P Fingerprint Module
  • Standby current: 6mA(DC12V)
  • Fingerprint capacity: 300 pieces

Instructions for control board

SET Button

  1. Press SET button shortly,system in register state and indicator light flash fast, press two times for each fingerprint, fingerprint register successful when hearing music. Fingerprint can be registered continuously when system in register state; if no need adding fingerprint more, waiting 8 seconds.(Fingerprint capacity is 100 pieces when press SET button, the registered fingerprints are stored in database 01)
  2. When back to factory default, press SET button until hear “Di” long beep and music,means initialization operation successful

Remote Control:

  1. Red indicator lighted means in programming stated, music means operation successful, default password: 123456,password length: 6numbers
  2. Change password: Press password1new passwordnew password#
  3. Register fingerprint: Presspassword2DD# , DD from 00 to 02(00, 01 and 02 refer to three different fingerprint databases), each database can store fingerprint 100 pieces; Exit fingerprint in register state when press button or waiting for 10s.
  4. Empty fingerprint: Press password3*password#
  5. Control Work Mode:
    • Press password4*00# Fingerprint module touch standby function ON
    • Press password4*01# Fingerprint module touch standby function OFF(Normally on Mode)
  6. Delay time for closing relay: Press password5*SS #; SS from 00 to 20, SS means the closing time for relay(from 0.5s to 20s), e.g.: 00 means 0.5s, 20 means 20s; Default time is 5s.
  7. Delete fingerprint: Press password6*DD#, DD from 00 to 02 (00, 01 and 02 refer to three different fingerprint databases).
  8. Password Using: Press *password and relay closed, press # and relay opened.
  9. Function Set: For function selection, when chose 2, closing time of the relay is 5s after pass fingerprint(5s is default time, and it can be adjusted by remote control);When chose 1, relay closed when fingerprint passed, relay will be opened when removing finger.