APOLLO 69 TANKMAX Tankmax Water Heater Tank Booster Instruction Manual
- June 4, 2024
- APOLLO
Table of Contents
69 TANKMAX Tankmax Water Heater Tank Booster
Instruction Manual
69TANKMAX
Installation Instructions
SAFETY PRECAUTIONS
Scalding Risk: Water temperatures above 125°F can cause severe burns,
resulting in severe injury or death. Scalding risk can be reduced at
120°-125°F, but even 120°F water can cause scalding injuries. Children, the
disabled, and the elderly are at the highest risk of being scalded. Feel water
before bathing or showering.
Your water heater thermostat (temperature control) temperatures should never
be turned above 120°F without a properly installed, properly commissioned, and
functioning Thermostatic Mixing Valve. If Tank Max is removed, decommissioned,
or suspected of being faulty, immediately lower the water heater thermostat
temperature to 120°F or lower in accordance with the water heater
manufacturer’s instructions.
INSTALLATION GUIDELINES
Delivery Temperature: Each valve is factory set for 120°F outlet temperature
with a 140°F hot water inlet temperature. To ensure delivery of the desired
mixed water temperature at the outlet, the installer must adjust and verify
the temperature at the outlet by carefully following installation
instructions.
Flush the system before installation: All debris should be flushed from the
plumbing system before installing Tank Max. Not flushing the system properly
may cause system difficulties.
- DO NOT subject the valve to heat during installation or damage may occur.
- DO NOT install valves on steam-supplied systems.
- DO NOT freeze the valve. If the valve is installed where freezing can occur, then suitable insulation must be provided to prevent damage to the valve.
- DO NOT use excess thread sealant (liquid, tape, or any other form) as this may cause the valve to fail.
Failure to comply with all aspects of the installation instructions may result
in unsafe performance.
All installations must comply with relevant state, provincial, and local codes
and laws.
INSTALLATION INSTRUCTIONS
-
Apply sealing tape to the hot and cold water connection threads on the water heater. Attach the union fitting to the hot water outlet of the water heater.
-
Attach the mixing valve to the NPSM Swivel end of the fitting as shown below.
-
Connect the tee to the cold water inlet of the water heater.
-
Apply sealing tape to the male threads of the mixing valve and tee. Check the installation orientation of both to ensure that the connection of the flexible hose can be allowed.
-
Connect the flexible hose from the mixing valve to the tee as shown below.
-
Connect the system’s cold water inlet supply hose to the tee and the hot water outlet supply hose to the mixing valve. Turn on the water and check for leaks.
TEMPERATURE ADJUSTMENT
-
Turn the hot water on at one faucet.
-
Remove the cap. You may need a flathead screwdriver to pry it off the valve.
-
Place the cap triangle end on the brass triangle on the mixing valve.
-
Turn the cap 1/4 turn counter-clockwise (to the left) to increase the water temperature to your house by 5º F. Turn the cap clockwise (to the right) to decrease the water temperature.
If your water heater is set to 140º or above, the mixing valve is factory pre- set to produce hot water at 120º F. The lowest setting for the valve is 100º F. The highest setting is the temperature at which your water heater is set.
TROUBLESHOOTING
If adjusting the temperature on the mixing valve doesn’t change your water temperature, remove the mixing valve from your water heater and clean the filter screens, one on the cold water inlet and one on the hot water inlet.
Warranty & Limitations of Liability
APOLLO INTERNATIONAL PRODUCTS: The Mosack Group, Inc. warrants its
international products, to its initial purchaser only, that its international
products which are delivered to this initial purchaser will be of the kind
described in the order or price list and will be free of defects in
workmanship or material for a period of TWO years from the date of delivery to
you, our initial purchaser.
THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED WARRANTY OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF
QUALITY, WHETHER EXPRESSED OR IMPLIED, EXCEPT THE WARRANTY OF TITLE AND
AGAINST PATENT INFRINGEMENT. Correction of non-conformities, in the manner
and for the period of time provided above, shall constitute fulfillment of all
liabilities of Conbraco to our initial purchaser, with respect to the goods,
whether based on contract, negligence, strict tort or otherwise. It is the
intention of The Mosack Group, Inc. that no warranty of any kind, whether
expressed or implied shall pass through our initial purchaser to any other
person or corporation.
LIMITATION OF LIABILITY: The Mosack Group, INC. SHALL NOT UNDER ANY
CIRCUMSTANCES BE LIABLE FOR SPECIAL OR CONSEQUENTIAL DAMAGES SUCH AS, BUT NOT
LIMITED TO, DAMAGES TO OR LOSS OF OTHER PROPERTY OR EQUIPMENT, LOSS OF PROFITS
OR REVENUE, COST OF CAPITAL, COST OF PURCHASED OR REPLACEMENT GOODS, OR CLAIMS
OF CUSTOMERS OF OUR INITIAL PURCHASER. THE REMEDIES OF OUR INITIAL PURCHASER,
AND ALL OTHERS, SET FORTH HEREIN, ARE EXCLUSIVE, AND THE LIABILITY OF CONBRACO
WITH RESPECT TO SAME SHALL NOT, EXCEPT AS EXPRESSLY PROVIDED HEREIN, EXCEED
THE PRICE OF THE GOODS UPON WHICH SUCH LIABILITY IS BASED.
*It is the end user’s responsibility to confirm that items intended for use satisfy local codes and standards.
The Mosack Group, Inc.
11210 Allen Station Dr, Mint Hill NC 28227
Customer Service: 1-888-229-2874
www.apolloflow.com
Tank Max Installation Booklet_09/20/21
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>