Royal Sovereign ARP-2214P 3-In-1 Portable Air Conditioner Owner’s Manual

June 5, 2024
Royal Sovereign

Royal-Sovereign-ARP-2214P-3-In-1-Portable-Air-Conditioner-
logo

Royal Sovereign ARP-2214P 3-In-1 Portable Air Conditioner

Safety Instructions

When using this unit follow these safety precautions to reduce risk of fire, electric shock, or injury

Electrical Safety

  1. For your safety, this unit should be properly grounded on a level surface indoors.
  2. The unit should be placed near an electrical outlet so that the outlet is easily accessible.
  3. Make sure the voltage meets the unit’s electricity requirements (115-120V/60Hz).
  4. Do not connect this machine to an outlet having the electrical ratings below or above this machine.
  5. In case of any abnormality, be sure to turn off the machine, disconnect the plug, and contact Royal Sovereign Customer Service.
  6. Do not operate if the electrical plug or power cord is damaged. If damaged, call Royal Sovereign Customer Service for repair/replacement.
  7. Do not under any circumstances alter the electric plug.
  8. Do not place heavy items on the plug or cord.
  9. Do not plug this cord into a loose electrical outlet.
  10. nly plug the unit into a properly installed, grounded 3 prong outlet.
  11. If the electrical outlet you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, you should have a qualified electrician install the proper outlet.
  12. Do not share the electrical socket with other appliances.
  13. Do not use an adapter plug or extension cord with this unit.
  14. Never attempt to turn off this machine by disconnecting the plug.
  15. When plugging or unplugging, keep your hands dry.
  16. Always grasp the plug when plugging or unplugging the unit. Never unplug by pulling on the cord.
  17. Do not pull on the power cord while moving the unit.
  18. This unit uses a plug with a built-in fuse. Conduct a Power Plug Check before use to confirm normal operation.
  19. Turn the unit off and unplug when: cleaning the unit, removing the filters, or not using the unit for an extended time period.

Operational Safety

  1. Install the unit according to the installation instructions supplied
  2. Do not block air outlets or intake with obstacles.
  3. Do not insert any objects into the unit.
  4. Do not place heavy items or sit on the unit.
  5. Do not place flammable or chemical substances near the unit.
  6. Do not place this machine near heating appliances.
  7. Do not splash or pour water on the housing or control panel.
  8. To prevent the water from freezing, do not use this machine and the drain hose at a temperature below 41°F (5°C).
  9. Ensure the rubber drain plugs are securely plugged into the drain ports on the back of the unit to prevent water leaks.
  10. Drain the unit before moving the unit or storing the unit.
  11. Do not operate the unit with the back cover removed.
  12. Do not use this machine outside.
  13. Do not modify any part of this product.
  14. Do not operate this unit for any other purpose other than its intended use.
  15. This unit is not designed for use by young children

Product View 

Royal-Sovereign-ARP-2214P-3-In-1-Portable-Air-Conditioner-
fig1

Unit

1 Louver 5 Air Inlet 8 Power Cord
2 Control Panel 6 Drainage Outlet 9 Drainage Outlet
3 Front Panel

Display

| 7| Air Outlet| 10     Cord Management
4| Caster Wheels| | |

Remote Control

1| Power (ON/OFF)| 4| Temperature

Down

| 7| Sleep Mode
---|---|---|---|---|---
2| Timer (ON/OFF)| 5| Temperature Up| 8| Swing (ON/OFF)
3| Mode (Cool /Dry

/ Fan)

| 6| Fan Speed|

Unpacking

Royal-Sovereign-ARP-2214P-3-In-1-Portable-Air-Conditioner-
fig2

Accessories Included:

  1. Exhaust hose
  2. Hose connector
  3. Window connector
  4. Remote control (battery included)
  5. Window kit
  6. Hose (used for continuous drainage option)

Important:
To prevent damage after moving, unpack the unit and let the unit stand upright for a minimum of 2 hours. If the unit was accidentally placed on its side, allow the unit to set upright for at least 24 hours before use

Placement

  1. Place the unit on a firm, level surface in an area with at least 12” (30cm) of free space around it to allow for proper air circulation. The electrical outlet used should be in accordance with the local electric safety requirements.
  2. Do not operate in close proximity to walls, curtains, or other objects that may block the units air inlet and outlet.
  3. Keep the air inlet and outlet free of obstacles.

Never install the unit where it could be subject to:

  • Heat sources such as radiators, heat registers, stoves or other products that products that produce heat.
  • Direct sunlight
  • Mechanical vibration or shock
  • Excessive dust
  • Lack of ventilation, such as next to a cabinet or bookcase
  • Uneven surface
BEFORE PLUGGING IN THE UNIT TO A POWER SOURCE:
  1. Let the unit stand upright for a minimum of 2 hours. This will reduce the chance of malfunction in the cooling system.
  2. Ensure the rubber drain plugs are securely plugged into the drain ports on the back of the unit to prevent any possible water leaks.
  3. Ensure the exhaust hose and window kit installation has been installed properly and properly vented
Conduct a Power Plug Check:
  1. Press the RESET button on the power cord.
  2. Plug the cord into an electrical outlet.
  3. Press the TEST button on the power cord. The RESET button should pop up.
  4. Press the RESET button for use.
  5. Do not use the air conditioner if the test fails.

NOTE:

  1. If you turn the air conditioner off and immediately restart it, allow up to 3 minutes for the compressor to restart cooling. In the event of a power failure, wait 3 minutes before restarting the unit.
  2. The unit sold in the United States is preset to Fahrenheit. the unit sold in Canada is preset to Celsius

Installation

The air conditioner requires being vented outside so that the exhaust air can escape the room. Do not replace or extend exhaust hose beyond its specification. This will result in decreased efficiency of the unit and may cause the unit to shut down due to low backpressure.
The window kit can be installed either horizontally or vertically. The window kit can be adjusted from 26.6”-47.2” (675-1200mm). The exhaust hose can be adjusted from 9.4”-59” (240-1500mm)

  1. Step 1:
    Connect one end of the exhaust hose to the window connector and the other end to the hose connector.

  2. Step 2:
    Connect the hose connector to the unit.

  3. Step 3. Connect the widow connector to the window kit. Extend the adjustable hose the length of your window

  4. Step 4: Open the window and place the window kit on the inside edge of the window. Adjust the window kit to the width /height of the window. Once secure, close the window to secure it in place. Note: Depending on the type of window frame, for some window installations the use of duct tape may be ideal to better seal the window kit to attain a better-closed seal which will yield maximum efficiency.

Operation

Unit Panel

Royal-Sovereign-ARP-2214P-3-In-1-Portable-Air-Conditioner-
fig10

A Power ON/OFF 3 Dehumidifying icon
B Fan speed 4 Fan Icon
C Temperature up 5 Digital Display
D Temperature down 6 Auto Swing Icon
E Mode (Cool, Fan, Dehumidify) 7 Low fan speed icon
F Timer ON/OFF 8 Medium fan speed Icon
9 High speed Icon
1 Sleep Icon 10 Water full Icon
2 Cooling Icon 11 Water full Icon

Note: Switching between °C/°F Setting:
Celsius /Fahrenheit setting can be done either using the remote control or the control panel. To change setting, press the “Temp +” and “Temp – ” buttons at the same time.

  • Cooling Mode
    Press the Mode button until the cool mode icon appears.
    Press the up or down icons to set the desired temperature.
    Press the Fan button to change between high, medium and low setting
    To control the direction of the air flow press the auto swing button

  • Mode
    Press the Mode button until the dehumidify icon appears
    In dehumidify mode, only fan runs at low speed and the temperature is not adjustable and the temperature .ais utomatically set to the current room temperature minus 2°C

  • Fan Mode
    Press the Mode button. The cool icon will appear
    In fan mode, only the unit will circulate air, while the units compressor is off.
    Press the Fan button to change between high , medium and low setting,
    To control the direction of the air flow, press the auto swing button

  • Timer Mode
    Timer ON Setting
    When the air-conditioner is OFF, press the Timer button . Select a desired ON time using the temperature and time setting buttons.
    “Preset ON Time” is displayed on the operation panel. (0-24 hours)
    Press the “Timer ” button again to confirm. The Timer indicator icon turns ON.
    To turn OFF the timer function, press the Timer button until timer indicator turns off.

  • Timer OFF setting
    When the air-conditioner ON, press the Timer button . Select a desired OFF time using the temperature and time setting buttons.
    “Preset OFF Time” is displayed on the operation panel. (0-24 hours)
    Press the “Timer ” button again to confirm,. The Timer indicator icon turns on.
    To turn OFF the timer function, press the Timer button until timer indicator turns off.

  • Sleep Mode
    While in cooling mode, press the sleep button to set the temperature. It will increase 1°C after an hour and at most increase 2°C after 2 hours.

  • Auto Swing
    Press this button to have the louver automatically swing continuously up and down.
    Press the button again to turn off Auto Swing function

  • Water Drainage
    Water Full Alarm
    The internal water tank in the air conditioner has a water level safety switch. When water level reaches or exceeds an anticipated height, the water full indicator light will turn on. This may happen in high humidity environmental conditions. In order for the unit to resume operation it must be drained.

To Drain Manually
  1. Turn off the power to the unit and unplug
    The unit has two locations for water draining, one in the middle and the other at the bottom

  2. Place a water tray under the drainage port at the middle of the unit to collect water

  3. Remove the rubber drainage plug and allow water to drain

  4. Replace the plug, when drainage water stops flowing

  5. Repeat step 2 -4 for the bottom locationRoyal-Sovereign-ARP-2214P-3-In-1-Portable-Air-Conditioner-fig11

Built into this unit is self-evaporating drainage feature. Under normal operating conditions, the self-evaporative feature of the unit will operate without issue or maintenance being required.
However, in high humidity conditions, you may need to drain manually water from the unit. (Ft error) You may also choose to do continuous drain option, which would drain water automatically from the unit (in dehumidifier mode)
For continuous drainage into a floor drain
To operate similar to a stand alone dehumidifier, you may choose to use continuous drain option

  1. Turn off the power to the unit and unplug the unit
  2. Remove the plug of the water outlet opening. (Either middle or bottom)
  3. Attach the drain hose . Ensure that the hose is straight without any knots and clear of obstruction.
  4. Place the other end of the drainage hose into a floor drain.
  5. Replace the rubber sealing plug after operation to prevent leaksRoyal-Sovereign-ARP-2214P-3-In-1-Portable-Air-Conditioner-fig12

CLEANING THE AIR FILTER

The filter should be cleaned about every 2 weeks to maintain proper air flow
Important: Do not operate the unit without an air filter, or the evaporator may be contaminated.

  1. Press POWER button to turn OFF the unit. Unplug the unit from the electrical power outlet.
  2. Remove the filter from the unit.
  3. Use a vacuum cleaner or a wet cloth to clean the air filter. Ensure that the air filter is dry before placing it back into the unit

STORAGE
If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. The unit must be kept in upright position when in storage.

  1. Unplug the unit and remove exhaust hose and window kit store with the unit.
  2. Drain the remaining water from the unit.
  3. Clean the filter and let the filter dry completely
  4. Re-install the filter.
  5. Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor

Troubleshooting

Troubles Possible Causes Suggested Remedies




1.Unit does not work

| – Water full indicator lamp blinks, and water tank is full.| Water tank needs to be emptied. Refer to water

drainage section of manual

– Room temperature is lower than the set temperature.| ****

Reduce the temperature setting

Unit not plugged in or reset button on power cord not set| Plug unit in or press the reset button






2. Not cool enough

| – The doors or windows are not closed.| Make sure all the windows and doors are closed.
– There are heat sources inside the room.| Remove the heat sources if possible
– Exhaust air hose is not connected or blocked.| Connect or clean the exhaust air hose.
– Temperature setting is too high.| Lower the temperature
– Air inlet is blocked.| Clean the air inlet.



3. Noisy

| – The ground is uneven or not flat| Place the unit on a flat, level surface
– Sound is heard from the flowing of the refrigerant inside the air

conditioner

| ****

This is normal operation


4. E0 Code

| ****

Room temperature sensor failed

| Replace room temperature sensor. Contact Royal Sovereign customer service


5. E1 Code

| Condenser temperature sensor failed| Replace condenser temperature sensor Contact Royal Sovereign

customer service


6. E2 Code

| ****

Water tank full when cooling

| Water tank needs to be emptied. Refer to water

drainage section of manual


6. E3 Code

| Evaporator temperature sensor failed| Replace evaporator temperature sensor Contact Royal Sovereign

customer service


7. E4 Code

| ****

Water tank full when in heating

| Water tank needs to be emptied. Refer to water

drainage section of manual

Specifications

  • Attributes
  • BTU: 14,000 BTU ASHRAE /10000 BTU SACC
  • Room Size: 500 sq. ft. (45m2)
  • Functions: Cool, Fan, Dehumidify
  • Touch Screen Control: Yes
  • Front LED Temperature Display: Yes
  • Automatic and Manual Louvres: Yes
  • Fan Speeds: 3
  • 24-Hour Timer: Yes
  • Sleep Mode: Yes
  • Auto Restart: Yes
  • Cord Management: Yes
  • Thermostat Range: 16-31°C /61-88°F
  • Selectable °C/°F setting: Yes
  • Airflow Volume: 300 m3/h
  • Water Removal: Self-evaporative
  • Dehumidify Capacity /Day: 36L (76 pints)
  • Sound: High <56dB
  • Window Kit Included: Yes. Kit frame adjustable from 26.6”-47.2” (675-1.200mm), Hose 9.4”-59” (240-1500mm) Refrigerant: R410A
  • Power Supply: 120V/60 Hz
  • Power Consumption: 1250W,11.2A
    • Dimensions and Weights
    • Unit Dimensions (w x d x h)
    • 440 x 357 x 690mm (17.3” x 14.1” x 27.2”)
    • Unit Weight: 26.3kg (58 lbs)

DISPOSAL

WARNING!!!
Releasing refrigerant into the atmosphere is strictly forbidden!
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.

  • All specifications mentioned are under test conditions, Actual performance depends on ambient conditions

One Year Limited Warranty

Royal Sovereign International, Inc. warranties this product to be free from defects in material and workmanship to the original purchaser only as outlined below.
Parts: Replacement of defective parts for 1 year from the date of customer purchase.
Compressor: 3-year warranty from the date of customer purchase. Royal Sovereign will supply a replacement compressor (parts only), free of charge.
Labour: 1 year from the date of end user purchase.
This warranty only covers products that are properly installed, properly maintained, and properly operated in accordance with the instructions provided. This limited warranty does not cover any failures or operating difficulties due to normal wear and tear, accident, abuse, misuse, alteration, misapplication, improper installation, or improper maintenance and service by you or any third party.
Returned products will not be accepted without a Return Authorization number. To request a Return Authorization number, please visit us at www.royalsovereign.com. All transportation costs for the return of damaged products or parts will be the responsibility of the purchaser. Return the defective product, in original packaging, to the address below.
Royal Sovereign International, Inc. (and its affiliated companies) requires reasonable proof of your date of purchase from an authorized retailer or distributor. Therefore, you should keep your receipt, invoice, or canceled check from the original purchase. The limited warranty shall be limited to the repair or replacement of parts which prove defective under normal use and service within the warranty period.
Royal Sovereign International, Inc. (and its affiliated companies) SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL,OR CONSEQUENTIAL DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion and limitations may not apply to you

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Royal Sovereign User Manuals

Related Manuals