Panasonic S-26PF2U6 Split System Air Conditioner Instruction Manual

June 16, 2024
Panasonic

Panasonic S-26PF2U6 Split System Air Conditioner Instruction Manual

Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

ALERT SYMBOLS **

**

WARNING
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
CAUTION
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.

INSTALLATION LOCATION

  • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.

WARNING

  • Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.

  • Do not install the air conditioner where excessively high heat-generating objects are placed

  • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the

Avoid: To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.

ELECTRICAL REQUIREMENTS

WARNING

  • All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.
  • It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fire.
  • Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.
  • Wiring must be done by a qualified electrician.

CAUTION
To warm up the system, the power mains must be turned on at least five (5) hours before operation. Leave the power mains ON unless you will not be using this appliance for an extended period.

Power mains
ON

NOTE
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time.

SAFETY INSTRUCTIONS

  • Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
  • This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.

WARNING

  • Confirm to authorized dealer or specialist on usage of specified refrigerant type.
    Using of refrigerant other than the specified type may cause product damage, burst and injury etc.

  • Never touch the unit with wet hands.

  • Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous.

  • Do not use this appliance in a potentially explosive atmosphere.

  • This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.

  • To prevent possible hazards from insulation failure, the unit must be grounded.

  • Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning.

  • In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair.

  • Check for a leaking refrigerant! Refrigerant gas may produce a toxic gas if it comes in contact with fire.

WARNING

  • For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing.
  • Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
  • Do not sit or step on the unit. You may fall down accidentally

CAUTION

  • Do not turn the air conditioner on and off from the power mains switch. Use the ON/ OFF operation button.

  • Do not stick anything into the air outlet of the outdoor unit.
    This is dangerous because the fan is rotating at high speed.

  • Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You may get injured.

  • Keep the fire alarm and the air outlet at least 5 feet (1.5 m) away from the unit.

  • Do not let children play with the air conditioner.

  • Do not cool or heat the room too much if babies or invalids are present.

  • Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged.

OPERATION CONDITION

Use this air conditioner under the following temperature range

Single Split System

Temperature range (°F/°C) Indoor Outdoor
*DBT *WBT *DBT
Cooling Max. 90/32
Min. 64/17.8 57/14
Heating Max. 86/30
Min. 61/16 –/–

* DBT:* Dry bulb temperature
WBT:** Wet bulb temperature

NAMES OF PARTS

INDOOR UNIT

LOW SILHOUETTE DUCTED

F2 type (standard static pressure)

Timer Remote Controller (Optional parts)

**NOTE

Refer to the Operating Instructions attached to the optional Timer Remote Controller.
(CZ-RTC2)
High-spec Wired Remote Controller (Optional parts)
NOTE
Refer to the Operating Instructions attached to the optional High-spec Wired Remote Controller.
(CZ-RTC3)

** ADJUSTING AIRFLOW DIRECTION

Low silhouette ducted type (F2)
This air conditioner is not equipped with air outlet parts. These must be obtained locally. Please refer to the manual of the locally adopted air outlet parts.

SPECIAL REMARKS

‘‘DRY’’ Operation

How it works

  • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically.
  • In order to prevent the humidity in the room from rising again, the indoor fan also turns off whenthe unit stops operating.
  • The fan speed is set to ‘‘LO.’’ automatically, and cannot be adjusted.
  • ‘‘DRY’’ operation is not possible if the outdoor temperature is 59°F or less.

Heating Operation
Heating performance

  • Because this appliance heats a room by utilizing the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this heat pump, use another heating appliance in conjunction with this unit.

Defrosting

  • When the outdoor temperature is low, frost or ice may form on the outdoor heat exchanger coil, reducing the heating performance. When this happens, a microcomputer-controlled defrosting system operates. At the same time, the fan on the indoor unit stops (or runs at very low speed in some cases) and the ‘‘STANDBY’’ indicator appears on the display until defrosting is completed. Heating operation then restarts after several minutes. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms.)

(standby) on the display

  • For several minutes after the start of heating operation, the indoor fan will not start running (or it will run at very low speed in some cases) until the indoor heat exchanger coil has warmed up sufficiently. This is because a cold draft prevention system is operating. During this period, the ‘‘ ’’ (standby) indicator remains displayed.
  • (standby) remains displayed during defrosting or when the compressor has been turned off (or when the unit is running at very low speed) by the thermostat when the system is in the heating mode.
  • Upon completion of defrosting and when the compressor is turned on again, ‘‘ ’’ (standby) will turn off automatically as heating operation resumes.

NOTE

Should the power fail while the unit is running
If the power supply for this unit is temporarily cut off, the unit will automatically resume operation (once the power is restored) using the same settings before the power was cut off.

CARE AND CLEANING

WARNING

  1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning.

  2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard.

Air Intake and outlet side (Indoor Unit)

Clean the air intake and outlet side of the indoor unit with a vacuum cleaner brush, or wipe them with a clean soft cloth.
If these parts are stained, use a clean cloth moistened with a mild liquid detergent. When cleaning the air outlet side, be careful not to force the vanes out of place.
CAUTION

  1. Never use solvents or harsh chemicals when cleaning the indoor unit. Do not wipe plastic parts using very hot water.

  2. Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts.

  3. The internal coil and other components of the outdoor unit must be cleaned every year. Consult your dealer or service center.

Air filter
(Field supplied)
The air filter collects dust and other particles from the air and should be cleaned at regular intervals as indicated in the table below. If the filter gets blocked, the efficiency of the air conditioner drops greatly.

WARNING

Type F2
Period (depending on filter specifications)

* Low Silhouette Ducted (F2)
An air filter is not provided with this air conditioner at the time of shipment. To get clean air and to extend the service life of the air conditioner, an air filter must be installed in the air intake.
For installation and cleaning the air filter, consult your dealer or service center.
NOTE
The frequency with which the filter should be cleaned depends on the environment in which the unit is used.

TROUBLESHOOTING

If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center.

INDOOR UNIT


Symptom Cause
Noise Sound like streaming water during operation or after operation
  • Sound of refrigerant liquid flowing inside unit

•        Sound of drainage water through drain pipe

Cracking noise during operation or when operation stops.| Cracking sound due to temperature changes of parts
Odor| Discharged air is smelled during operation.| Indoor odor components, cigarette odor and cosmetic odor accumulated in the air conditioner and its air is discharged.Unit inside is dusty. Consult your dealer.
Dewdrop| Dewdrop gets accumulated near air discharge during operation| Indoor moisture is cooled by cool wind and accumulated by dewdrop.
Fog| Fog occurs during operation in cooling mode.(Places where large amounts of oil mist exist at restaurants.)|

  • Cleaning is necessary because unit inside (heat exchanger) is dirty. Consult your dealer as technical engineering is required.
  • During defrost operation

Fan is rotating for a while even though operation stops.|

  • Fan rotating makes operation smoothly.
  • Fan may sometimes rotates because of drying heat exchanger due to settings.

Dust| Dust accumulation inside indoor unit is discharged.
At the initial high-speed operation, the fan may sometimes rotate faster (for 3 to 30 minutes) than the setting speed.| This is for operation check in order to confirm whether the fan motor rotation is within use range.

OUTDOOR UNIT

Symptom Cause
No operation When power is turned ON instantly.

for the first approx. 3 minutes because compressor protection circuit is activated.
When operation is stopped and resumed immediately.
Noise| Noise often occurs in heating mode.| During defrost operation
Steam| Steam often occurs in heating mode.
When stopped by remote controller, outdoor unit fan is sometimes operating for a while even though outdoor compressor is stopped.| Fan rotating makes operation smoothly.

CHECK BEFORE REQUIRING SERVICES

Symptom Cause Remedy
Air conditioner does not run at all although power is turned on. Power
failure or after power failure Press ON/OFF operation button on remote

controller again.
Operation button is turned off.|

  • Switch on power if breaker is turned off.
  • If breaker has been tripped, consult your dealer without turning it on.

Fuse blow out.| If blown out, consult your dealer.
Poor cooling or heating performance| Air intake or air discharge port of indoor and outdoor units is clogged with dust or obstacles.| Remove dust or obstruction.
Wind speed switch is set to “Low”.| Change to “High” or “Strong”.
Improper temperature settings| Refer to “TIPS FOR ENERGY SAVING”.
Room is exposed to direct sunlight in cooling mode.
Doors and /or windows are open.
Air filter is clogged.| Refer to “CARE AND CLEANING”.
Too much heat sources in room in cooling mode.| Use minimum heat sources and in a short time.
Too many people in room in cooling mode.| Reduce temperature settings or change to “High” or “Strong”.

If your air conditioner still does not work properly although you checked the points as described above, first stop the operation and turn off the power switch. Then contact your dealer and report the serial number and symptom. Never repair your air conditioner by yourself since it is very dangerous for you to do so. You also report if the inspection mark ****and the letters E, F, H, L, P in combination with the numbers appear on the LCD of the remote controller.

TIPS FOR ENERGY SAVING

Avoid

  • Do not block the air intake and outlet of the unit. If either is obstructed, the unit will not work well, and may be damaged.
  • Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room.

Do

  • Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit.
  • To prevent conditioned air from escaping, keep windows, doors and any other openings closed.

NOTE
Should the power fail while the unit is running

If the power supply for this unit is temporarily cut off, the unit will automatically resume operation once power is restored using the same settings before the power was interrupted.

SPECIFICATIONS

Model Name S-26PF2U6 S-36PF2U6
Power Source 208 / 230 V, 60 Hz, 1PH
Cooling Capacity BTU/h 24,000
kW 7.0 9.1
Heating Capacity BTU/h 28,600
kW 8.4 10.6
Sound Pressure Level (H/M/L) dB(A) 35/32/26
**** Unit Dimensions H : inch (mm) 11-7/16 (290)
W : inch (mm) 39-3/8 (1000) 55-1/8 (1400)
D : inch (mm) 27-9/16 (700) 27-9/16 (700)
Net Weight lbs. (kg) 73 (33)

Model No.

Indoor Unit|
---|---


Type

| ****

Indoor Unit Type

| Nominal Capacity
26| 36
F2| Low Silhouette Ducted| S-26PF2U6| S-36PF2U6
| | | |

  • Connectable outdoor unit lineup

This booklet is the operating instructions for indoor unit. Regarding the outdoor unit, see the operating instructions supplied with the outdoor unit.

Outdoor Unit|
---|---
Type| Outdoor Unit Type| Nominal Capacity
26| 36| Remarks
U| Single| U-26PE1U6| U-36PE1U6| Cooling/Heating
| | | |

Panasonic Corporation 2014 Printed in China Panasonic Corporation
Website: http://panasonic.net/ F569696 BE0414-10814

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals