Whirlpool UXT4230AY Range Hood User Guide

June 16, 2024
Whirlpool

Whirlpool UXT4230AY Range Hood

Product Information

Specifications

  • Product Model Numbers: UXT4230AY, UXT4236AY
  • Electrical: 120 volt, 60 Hz., AC only, 15-amp, fused electrical
    circuit is required

Venting Methods

Note: Flexible vent is not recommended. Flexible vent creates both back pressure and air turbulence that greatly reduce performance.

  1. Roof Venting
  2. Wall Venting

Product Dimensions

Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.

Installation Clearances

  • A. 18 (45.7 cm) min. clearance – upper cabinet to
    countertop

  • B. 18 (45.7 cm) to 24 (61.0 cm) suggested max. – bottom of range hood to cooking surface

  • C. 30 (76.2 cm) min. cabinet opening width for 30 (76.2 cm) models and 36 (91.4 cm) min. cabinet width for 36 (91.4 cm) models

  • D. 13 (33.0 cm) cabinet depth

  • E. 36 (91.4 cm) base cabinet height

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Product Usage Instructions

Electrical Connection

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required. If the house has aluminum wiring, follow the procedure below:

  1. Connect a section of solid copper wire to the pigtail leads.
  2. Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum. Follow the electrical connector manufacturer’s recommended procedure.
  3. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

Venting Methods

Note: Flexible vent is not recommended. Flexible vent creates both back pressure and air turbulence that greatly reduce performance.

  1. Roof Venting: Follow the instructions in the Installation Instructions packed with the product for proper roof venting.
  2. Wall Venting: Follow the instructions in the Installation Instructions packed with the product for proper wall venting.

Installation Clearances

Ensure proper installation clearances for optimal performance:

  • A. 18 (45.7 cm) minimum clearance between the upper cabinet and countertop.
  • B. 18 (45.7 cm) to 24 (61.0 cm) suggested maximum clearance between the bottom of the range hood and the cooking surface.
  • C. 30 (76.2 cm) minimum cabinet opening width for 30 (76.2 cm) models and 36 (91.4 cm) minimum cabinet width for 36 (91.4 cm) models.
  • D. 13 (33.0 cm) cabinet depth.
  • E. 36 (91.4 cm) base cabinet height.

Calculating Vent System Length

To calculate the length of the vent system, add the equivalent feet (meters) for each vent piece used in the system. Refer to the Installation Instructions packed with the product for more details.

FAQ

Q: Can I use flexible vent for the range hood?

A: No, flexible vent is not recommended as it creates back pressure and air turbulence that greatly reduce performance.

Q: What are the recommended electrical requirements for the range hood?

A: The range hood requires a 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit.

Q: How should I connect the range hood if my house has aluminium wiring?

A: If your house has aluminium wiring, follow the instructions provided in the user manual to connect a section of solid copper wire to the pigtail leads and then connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.

30″ (76.2 cm) and 36″ (91.4 cm) Range Hood

PRODUCT MODEL NUMBERS

UXT4230AY
UXT4236AY

Electrical

  • A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
  • If the house has aluminum wiring, follow the procedure below:
  1. Connect a section of solid copper wire to the pigtail leads.
  2. Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.
    Follow the electrical connector manufacturer’s recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.
  • Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.
  • Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.
  • 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

VENTING METHODS

Vent system can terminate either through the roof or wall. Use 3¹⁄₄” x 10″ (8.3 x 25.4 cm) rectangular with a maximum vent length of 35 ft (10.7 m) or 7″ (17.8 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.

NOTE: Flexible vent is not recommended. Flexible vent creates both back pressure and air turbulence that greatly reduce performance.

Roof Venting

  • A. 7″ (17.8 cm) round vent through roof (purchased separately) 3¹⁄₄” x 10″ (8.3 x 25.4 cm) rectangular vent through the roof (purchased separately)
  • B. Roof cap with damper (purchased separately)
  • C. 18″ (45.7 cm) min. to 24″ (61.0 cm) max. above the cooking surface

Wall Venting

  • A. 7″ (17.8 cm) round vent out the top and through the wall (purchased separately) 3¹⁄₄” x 10″ (8.3 x 25.4 cm) rectangular vent through the wall or out the top (purchased separately)
  • B. Wall cap with damper (purchased separately)
  • C. 18″ (45.7 cm) min. to 24″ (61.0 cm) max. above the cooking surface

Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

7″ (17.8 cm) Round Vent System

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Example vent system

Maximum Recommended Length

PRODUCT DIMENSIONS

Installation Clearances

  • A. 18″ (45.7 cm) min. clearance – upper cabinet to countertop
  • B. 18″ (45.7 cm) to 24″ (61.0 cm) suggested max. – bottom of range hood to cooking surface
  • C. 30″ (76.2 cm) min. cabinet opening width for 30″ (76.2 cm) models and 36″ (91.4 cm) min. cabinet width for 36″ (91.4 cm) models
  • D. 13″ (33.0 cm) cabinet depth
  • E. 36″ (91.4 cm) base cabinet height

Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.

Ref. W10400322C
11/6/12