ZEBRONICS Zeb-U1205 Uninterruptible Power Supply User Manual
- June 4, 2024
- ZEBRONICS
Table of Contents
ZEBRONICS Zeb-U1205 Uninterruptible Power Supply
Dear Customer,
Thank you for purchasing the ZEB-U1205 UPS. Please read the user manual
carefully before usage & save it for future reference.
Important Safety Instructions
- The voltages inside UPS may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs.
- Internal battery voltage is 12Vdc. sealed, lead-acid, 6 cells battery.
- Connection to any other type of socket other than a two-pole, three-wire grounded socket may result in shock hazard as well as violating to local electrical codes.
- In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. Do not allow liquids or any external objects to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
- This unit is designed for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is static or flowing water, or excessive humidity.
- Do not plug the UPS input into its own output.
- Do not attach a power strip or surge suppressor to the UPS.
- Do not connect non-computer-related items, such as medical equipment, lifesupport equipment, microwave ovens, or vacuum cleaners to UPS.
- To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as air heaters or furnaces.
- Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
- Do not dispose the batteries into fire as they may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
- A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
- Remove watches, rings, or other metal objects from the hands.
- Use tools with insulated handles.
- Wear rubber gloves and boots.
- Do not lay tools or metal parts on top of batteries.
- Disconnect charging source prior to connecting or disconnecting batteries terminals.
- Servicing of battery should be performed or supervised by technical and authorized personnel only.
- When replacing battery, replace with the same type of sealed lead-acid battery. The maximum ambient temperature rating is 40° C
UPS Installation Procedure
- Your new UPS may be used immediately; however recharging the battery for at least 8hours (no load) is recommended to ensure that the battery maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
- With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive, Tape drive, etc.) into the battery power supplied outlets. DO NOT plug laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
- Plug the UPS into a 2 pole, 3 wire grounded socket (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator. copier, etc. Avoid using extension cords.
- Press the power switch to turn the unit ON. The power on indicator light will illuminate and the unit will “beep”.
- If an overload is detected, an audible alarm will sound and the unit will emit beep once every 0.5 seconds. To correct this turn the UPS off and unplug atleast one piece of equipment from the battery power supplied outlets. Wait 10 seconds and then turn the UPS on.
- To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
- To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to ensure battery life.
Product Description
Front Panel
-
Power Switch
-
LED Indicators
- AC Mode : Green LED Glow
- Battery Mode : Orange
- LED blinks Fault Mode : Red LED Glow
Back Panel
-
AC input
-
Output Sockets
Power On/Off (AC mode)
To turn on the UPS unit, press the power switch lightly. To turn off the UPS
unit, press the power switch again
Power On/Off (Battery mode)
To start the UPS when AC utility power is not available, simply press the
power switch.
LED Indication and Alarm
Condition | Indication | Alarm |
---|---|---|
Normal | Green LED Glows | —- |
Battery Discharge | Orange LED blinks | Beep once every 10 seconds |
Battery Low | Red LED Glow and Orange LED flashing | Beep once every 1 second |
Overload | Orange LED flashing | Beep once every 0.5 seconds |
Fault | Red LED Glow | Continuous alarm |
Features
- Line Interactive UPS
- Auto Restart while AC is Recovering Double Boost
- Automatic Voltage Regulation (AVR) Wide Input Range
- Microcontroller Based
- Generator Compatible
Specifications
Capacity | (VA/W) | 1000VA/600W |
---|---|---|
Input | Nominal voltage | 220-240 VAC |
Voltage range | 140-300 VAC | |
Frequency | 50/60 Hz | |
Plug type | 3 Pin plug | |
Output | Voltage range | 23OVAC±5% (AC mode) |
Voltage range | 230VAC±10% (Batt. mode) | |
Frequency range | 50/60Hz±1% (Batt. mode) | |
Transfer time | 4-8ms typ. | |
Waveform | Simulated Sine Wave | |
No. of output sockets | 4 | |
Protections | Overload, Short Circuit, Over Discharge & Over Charge | |
Battery | Battery type | 12V 7Ah x 2 nos |
Charging current | 1.2A | |
Recharge time | 6-8h typ. (up to 90% capacity after complete discharge) | |
Indicators | No. of LEDs | 3 LED |
AC mode | Green LED Glows | |
Battery mode | Orange LED blinks in an interval of 10 seconds | |
Fault mode | Red LED Glows | |
Alarm | Battery mode | Beeping every 10 Secs. |
Low battery | Beeping every 1 Sec. | |
Overload | Beeping every 0.5 sec. | |
Fault | Continuous beeping | |
Physical details | Dimension | 130 x 314 x 175 mm (WxDx H) |
Net. weight | 7.19 kg | |
Package dimension | 173 x 368 x 248 mm (WxDxH) | |
Environmental factors | Operational temperature | 0-40°C |
Noise level | < 45dB |
Troubleshooting
Problem | Possible Cause | Solution |
---|---|---|
No LED Indicator on the front panel | Battery weak | Charge battery up to 8 |
hours
Battery defect| Replace with the same type of battery
Power switch is not pressed| Press the power switch again
Alarm buzzer beeps continuously when AC supply is normal| Overload of the UPS|
Verify that the load matches the UPS capability specified in the specs
When power failure, back-up time is shorten| Overload of the UPS| Remove some
non-critical load
Battery voltage is too low| Charge battery 8 hours or more
Battery defect due to high temperature operation environment, or improper
operation to battery| Replace with the same type of battery
Mains normal but Battery Mode indicator orange LED is flashing (for LED
model)| Power cord is loose| Reconnect the power cord properly
If any abnormal situations occur that are not listed above, please call service person immediately.