VIAVI 4100 Series ONA-800 Modular Test Set User Guide
- June 16, 2024
- VIAVI
Table of Contents
VIAVI 4100 Series ONA-800 Modular Test Set
USER GUIDE
Real Time Testing with Smart Test Assistant
This quick card describes how to connect to a fiber under test, configure SMART TEST Assistant with Real Time test OTDR settings, run tests, and analyze results with a VIAVI ONA-800 and 4100-series OTDR module.
Equipment Requirements:
- ONA-800 or ONA-1000 with Fiber Optics Software Release V21.04 or greater
- E4100 Series OTDR Module
- Fiber optic cleaning and inspection tools
- Launch Cable with connectors matching the OTDR port and Fiber Under Test (a minimum 20- meter Fiber optic patch cable or leash is recommended)
- Optical Coupler to connect Launch Cable to Fiber Under Test
The following information is required to complete the test:
- Type of Fiber (Multimode or Single Mode)
- Type of Connectors (SC UPC, SC APC, LC UPC, etc.)
Fiber Inspection Guidelines:
- Use the VIAVI P5000i or FiberChek Probe microscope to inspect both sides of every connection being used (OTDR Port, Launch Cable, bulkhead connectors, patch cords, etc.)
- Focus fiber on the screen. If dirty, clean the end-face.
- If it appears clean, run inspection test.
- If it fails, clean the fiber and re-run inspection test. Repeat until it passes.
Connect Launch Cable to OTDR port:
1. Inspect the OTDR port on top of the test set.
2. Inspect the fiber end face of Launch Cable.
3. Connect Launch Cable to the OTDR port.
Connect to Fiber Under Test (FUT):
The Launch Cable may be connected to the FUT via an optical patch panel (OPP) or an optical coupler:
1. If the interface to the FUT is a patch cord, connect the patch cord to an
optical coupler with the same connector type.
2. Inspect the FUT connected to the coupler or OPP.
3. Inspect the other fiber end face of the Launch Cable.
4. Connect the Launch Cable to the coupler or OPP.
Launch Smart Test Assistant:
1. Press the Power button on the top left of the ONA-800 to start the
instrument.
2. Tap the Tests, Fiber 1 and SMART TEST icon until it is Blue and
highlighted .
3. Select the CERTIFICATION configuration file
4. Tap to load the configuration and view the SMART TEST Setup screen.
Configure Test:
1. Laser: If the wrong wavelength is selected, tap the screen to deselect.
Tap the desired wavelength to test.
2. Distance Unit: Tap the desired unit of measure for the launch cable.
3. Launch Cable: Tap to select No.
4. Alarms: Tap to select No.
Run Test:
1. Tap to start the test. After auto-configuration, the OTDR will perform a
connection check to ensure that the connection is Good. If the Connection is
Bad, disconnect the launch cable, and reconnect as described on pages 1, 2 and
3, cleaning every end-face that fails the inspection test.
2. The OTDR will perform real-time acquisitions at the configured wavelength.
You can optimize the trace on the screen by using Automatic zoom and start
Measurements by using .
3. Tap the roll down menu Test to measure Loss or ORL or Reflectance at the
bottom left screen.
4. You can select the A or B cursors to change ` measurements values. Just
select the B cursor and move it on the screen to the position where
measurement is required.
5. Figure 11 shows Loss measurement, Figure 12 shows ORL measurement while
Figure 13 shows Reflectance measurement.
6. View SmartLink and Table are disabled in Real Time mode.
7. Select to stop the Real Time measurement. If you need to restart the real
time measurement, just select
Specifications:
- Product: VIAVI Solutions ONA-800 Modular Test Set
- Real Time Testing with Smart Test Assistant
Contact Us +1 844 GO VIAVI
(+1 844 468 4284)
To reach the VIAVI office nearest you,
visit viavisolutions.com/contacts.
© 2021 VIAVI Solutions Inc.
Product specifications and descriptions in this
document are subject to change without notice.
FAQ:
Q: How do I contact VIAVI for support?
A: You can contact VIAVI by calling +1 844 GO VIAVI (+1 844 468 4284) or visiting viavisolutions.com/contacts to find the nearest VIAVI office.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>