nVent A22 Standard Coupler Installation Guide

June 16, 2024
nVent

nVent LENTON Installation Instructions

Standard Coupler ­- Americas


|

Optimal Torque¹

in.-lb.

| Metric| Canada| Nm| ft.-lbs.

3| 10| —| 40|

30

4

| 12| 10M| 40| 30
—| 14| —| 80|

60

5

| 16| 15M| 120| 90
—| 18| —| 150|

110

6

| 20| 20M| 180| 130

7| 22| —| 220|

160

| 24| —| 270| 200

8| 25| 25M| 270|

200

| 26| 26M| 270| 200

9| 28| 30M| 270|

200

| 30| —| 300| 200*

10| 32| —| 300|

200*

| 34| —| 300| 200*

11| 36| 35M| 300|

200*

| 38| —| 350| 200*
—| 40| —| 350|

200*

14

| 43| 45M| 350| 200*
—| 50| —| 350|

200*

18

| 57| 55M| 350|

200*

nVent A22 Standard Coupler A3

+ Metric and Imperial table values are not a direct conversion

  • Americas only
    Note 1: Refer to the “SNUG Tight Installation Instruction in this document”

SNUG Tight Installation Instructions: SNUG Tight installation (>5 ft-lbs) may be used with ASTM A615 or A706 Grade 60 and Grade 80 rebar for commercial projects when splice performance requirements are limited to only ACI 318 Type 1 (125% Specified Yield) or Type 2 (Specified Tensile), or when otherwise approved by the project. Additional steps may be necessary to secure product for transportation and handling.

WARNING:

  1. nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Instruction sheets are available at www.nVent.com and from your nVent customer service representative.
  2. nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
  3. All instructions must be completely followed to ensure proper and safe installation and performance.
  4. Improper installation, misuse, misapplication, or other, failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury, and/or death, and void your warranty.

The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer.
c. Using appropriate industry standard hardware as noted above.

SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed.
Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.

nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent EIRFLEX, and nVent LENTON are registered trademarks of nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.

TECHNICAL SUPPORT:
www.nVent.com

IPNASC01

© 1995 -­ 2023 nVent All Right Reserved

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals