Contents:
Sensor Specifications:
Relay On/Off Model:
500 Watts Incandescent
100 Watts Fluorescent at 120 Volts
500W LED BULLET12 at 120 Volts
5 Amps, 450 Watts LED at 120 Volts with .. 0.8pF driver
5 Amps, 300 Watts LED at 120 Volts with .. 0.5pF driver
Voltage: 120 Volts AC
Power Consumption: One watt
UL Listing: Raintight Photoelectric Switch Suitable for wet locations.
Time Adjustment: 5 seconds to 15 minutes
Quick Test Time: 5 second test time for fast installation. Works day or
night.
Detection Zone: Full 180º by 30’
“No Hands” Auto Testing: Auto mode starts after 3 minutes of testing. No
adjustment needed.
Built for Severe Conditions: Double weatherproofing for long life.
Photoelectric Control: Deactivates lights during daylight.
Fully adjustable for 24 hour operation or custom applications.
Vandal Resistant Lens: Hard lens resists casual vandalism.
Case Construction: Precision molded Lexan®
Color Matched Lens: Dark lens with black units.
White lens with white units.
Surge Protection: Withstands up to 3000 Volts
Manual Override: Double flip wall switch logic prevents activation by
short power outages.
Resets to auto at dawn.
No extra wiring needed.
LED Detection Indicator: Glows red day and night for “on-guard”
deterrence.
RF Immunity: Circuits fully shielded for maximum radio frequency
immunity.
Why RAB Sensors are BEST for You?
Smaller is better!
Mini Sensor uses state-of-the-art surface mount technology (SMT), just like cellular phones and beepers. SMT gives you more reliability, greater RF immunity, and a compact sensor that can fit neatly where others cannot.
Wider is better!
The wide 180º view detects movement along the entire side of a building with
only one compact sensor. It will detect people as they exit or enter. It takes
several conventional sensors to get the same coverage.
Molded is better!
No leaky gaskets or bug hotels with Mini Sensor. The hard lens is molded as
part of the case. It’s vandalproof, rainproof, bugproof and absolutely sealed.
Caution
- All wiring MUST comply with local electrical codes and should be installed by qualified electrician.
- Read entire Installation Manual before proceeding.
TURN OFF POWER BY REMOVING POWER FUSE OR TURNING OFF CIRCUIT BREAKER BEFORE INSTALLATION.
-
Total lighting load must not exceed: 500W LED BULLET12 at 120 Volts
5 Amps, 450 Watts LED at 120 Volts with .. 0.8pF driver
5 Amps, 300 Watts LED at 120 Volts with .. 0.5pF driver.
To switch more wattage, an electrician can install an additional relay. -
Line Carrier Remote Control Systems such as X-10, Leviton or Radio Shack are incompatible with sensors and cause false activations.
-
Do not install on circuits feeding motor loads such as kitchen appliances, HVAC equipment, washer/ dryer or garage door openers.
-
Sensor functions best when movement is across its detection pattern, not towards the sensor.
-
Mount 6’-10’ high for optimum range and direction.
Assembly and Wiring
Two BULLET12 heads come pre-wired and assembled along with SMS500 sensor on CU4 plate, allowing for mounting on round, rectangular or octagonal surface or recessed boxes.
- Connect the black fixture lead to the (+) LINE supply lead.
- Connect the white fixture lead to the (-) COMMON supply lead.
- Connect the GROUND wire from fixture to supply ground.
- Red pigtail is only used to switch remote or additional fixtures.
Mounting ****
- Attach the Universal Mounting Bar with the screws provided to the Junction Box. In case of surface mount junction box, use with the Metal Surface Plate. For proper weatherproof seal, apply weatherproof silicone sealant around the edge of the Junction Box. This is especially important with an uneven wall surface.
- Use the ‘S’ shaped hands free Hanging Hook to hold the CU4 Plate during wiring.
- Bring power leads and BULLET12 head leads into Junction Box.
- Strip off atleast 1/2” of insulation from all leads, and insert through openings in Metal Surface Plate (if used).
- Attach ground wire to grounding screw on Junction Box. Complete wiring as shown in wiring diagram section.
- Align Gasket, CU4 Plate and Metal Surface Plate (for use with surface mounted junction boxes) to ensure proper seal.
- Tighten Center Screw (make sure O-Ring Gasket is on the screw) to attach CU4 plate to the box. Check that the Gasket is fully sealed.
- Insert plastic Finishing Cap in the center of the CU4 Plate for a weatherproof seal. Use silicone sealant on all plugs and unused conduit entries.
- Aim BULLET12 heads in the desired direction and tighten locknut and arm screw.
Wiring Diagrams
To override sensor with a manual switch
To switch more than rated load Multiple sensors:
Wiring more than one sensor together is recommended only for the
experienced installer because it becomes difficult to troubleshoot. Single
sensors that control their own lights pinpoint movement more accurately and
operate better.
Power Quality:
Sensors should not be installed on a circuit that also feeds motor loads
such as HVAC equipment, kitchen appliances, or garage door openers. If voltage
varies significantly from 120 volts, sensors may malfunction.
How Does RAB’s Mini Sensor Work?
The Mini Sensor infrared sensor “sees” small temperature changes caused by
the motion of people or cars within its detection zone and turns on lights
automatically. It welcomes visitors and may deter intruders.
How long do the lights stay on?
Lights remain on as long as there is movement within the Detection Zone.
Once the zone is vacated, lights can be adjusted to remain on approximately 5
seconds up to 15 minutes.
Will the sensor detect animals?
Mini Sensor may detect large animals.
Having animals trigger the sensor can give property a “lived-in” look. You can
limit animal detection by placing opaque weatherproof tape on the lower part
of the lens or using the bottom mask on the Lens Mask Kit provided. What
does Manual Override do?
Keep lights on by flipping the wall switch two times within 5 seconds. Sensor
resets to auto mode at dawn. No extra wiring needed.
How are the Time, Sensitivity and Photocell adjusted?
TimeControl: Sets the time that lights will remain on after the Detection
Zone is vacated from approximately 5 seconds to 15 minutes. Use the adjustment
tool provided to turn clockwise to increase the time.
Factory Setting: 5-8 minutes.
Photocell Control: For night only operation, use the tool provided or a
small screwdriver to turn the Photocell Control all the way counter-clockwise
(to the moon symbol). For operation in low level lights, turn the knob all the
way clockwise (to the sun symbol). Adjust counterclockwise to have the sensor
come on later at dusk, clockwise to have it come on earlier. Turning photocell
control will show when the sensor “thinks” the current ambient light level =
night, because the lights will turn on.
Factory setting : Night Only
Sensitivity: Increases or decreases the responsiveness and range of the
sensor.
Control Panel:
Turn controls gently using adjustment tool provided. Do not force past stops.
Picking A Location
Location Considerations:
- Choose a location from which the sensor can “see” all the paths of movement that will be illuminated by its lights.
- Mini Sensor may be wall or ceiling mounted.
- Sensor functions best when the direction of expected movement is across its detection pattern, not towards the sensor.
- If wall mounting, locate 6-10’ high for optimum range and detection. Lower mounting height will reduce range.
Sensor must be below and as far as possible away from lights. If ceiling mounted be sure there are no lights below sensor.
Detection Pattern:
- The sensor has a “Double Look Down” Lens with one “Look Out” zone and two “Look Down” zones, for excellent detection both at long and close range.
- Detection extends out a maximum of 30 feet and is 180º wide.
- To reduce the Detection Pattern length, aim the sensor down
- To reduce Detection Pattern width, mask the sides of the lens with the Lens Mask Kit provided or opaque weatherproof tape.
- If sensor is mounted by a doorway at the top of stairs, be aware that the elevated mounting height may extend the sensors range.
- As distance from the sensor increases, it will take more movement to be detected. For instance, at 10 feet, a half step will be enough, while at 30 feet, several steps will be necessary.
Double Look Down Lens
Aiming and Walk Testing
Test Period:
The sensor has a 3 minute Test Period which allows it to be aimed and walk
tested day or night.
- For the first 30 seconds, the lights will be turned on. During this time, test that all fixtures and lamps function properly.
- For the next 3 minutes, the sensor will keep lights on for 5 seconds each time it detects movement in its Detection Zone. The sensor will change to Automatic Mode after the 3 minute Test Period.
- If another 3 minute Test Period is desired, turn the power off for at least 10 seconds and back on again.
Walk Test:
The purpose of the Walk Test is to check and adjust the coverage pattern.
- Aim the sensor approximately to cover the area you desire.
- Start outside the Detection Zone and walk across the zone until the lights go on. As distance from the sensor increases, it will take more movement to be detected. For instance, at 10 feet, a half step will be enough, while at 30 feet, several steps will be necessary.
- To reduce range, use the lens masks provided or tilt sensor down.Repeat steps #2 and #3 until you are satisfied with the coverage.
- The Time Control is factory set between 5-8 minutes. This period starts after the movement in the Detection Zone ceases. If less time is desired, turn the time control counterclockwise. For more time, turn the control clockwise.
- The sensor is factory set for night only operation. To obtain full operation 24 hours per day, turn the Photocell Control fully clockwise to the sun symbol. Intermediate settings will allow the sensor to operate earlier or later at dusk.
- Your sensor is ready for operation. See the Technical Tips pages if additional help is needed.
Control Panel:
Turn controls gently using the adjustment tool provided. Do not force past
stops.
Technical Tips: Lights Do Not Turn Off
-
Make sure sensor is not aimed at something that would move or change temperature such as waving branches, water, air conditioners, windows or heating vents – even on neighboring property. You can test for infrared sources in the area by placing a box or bag over the sensor. Put sensor into Test Mode. After the initial 30 seconds of the lights being on, lights should stay off. Wave your hand inside the bag in front of sensor. Lights should go on and then time out. If sensor operates properly when covered, check items 2-6.
Problem: Sensor is triggered by unwanted movement or heat source. Solution: Tilt sensor (Pg.8) or mask lens in the direction of the source. Move sensor or source. -
Make sure sensor is mounted firmly and does not move even slightly when touched. If it moves, tighten all screws.
-
Make sure that Mini Sensor is not mounted on an unstable object such as a tree or a pole that will move in the wind.
-
Was sensor wired hot? If so, circuitry may have been damaged.
-
Make sure sensor is not aimed within 30 feet of a road.
Problem: Passing cars activate sensor. Solution: A 20’ safety zone between the sensor and road is recommended to avoid activation from passing cars.
You may tilt sensor to not aim in the direction of the street or mask top of sensor lens to reduce range (Pg. 8) -
Make sure heat from lights is not triggering sensor. Make sure the sensor is below and as far as possible away from lights.
Technical Tips: Range appears limited
- Check that the sensor is level from side to side and pointed at the area you desire. If unit is tilted, part of the Detection Zone may be high in the air over people’s heads. Solution: Position sensor exactly level from side to side.
- Check that the sensor is not mounted too high. If mounted above 20 feet, much of the usable range will be lost. Solution: Mounting at 5’ to 8’ allows maximum range.
- If sensor is painted, make sure there is no paint on the lens and that the lens paint mask is removed.
- Check that movement is not directly towards sensor. Sensor will see movement across its pattern more quickly. To fix, move the sensor.
- Check that movement far away and directly towards sensor is not entirely within one Detection Pattern finger.
Problem: Sensor will not detect until movement crosses from one finger into a second finger.
No detection until here Solution: “Micro Adjust” sensor by tilting sensor 1/16”. This small adjustment may move the zones to allow earlier detection.
Technical Tips: Lights Do Not Turn On
-
Check that lamps and fixtures work.
Compare wiring to the Wiring Diagram in this manual. Check that the power is on. -
If installing during daylight, remember that the sensor will provide a 3 minute Test Period after power is turned on. After 3 minutes, the sensor will switch to Automatic Mode and will not work during daylight if the Photocell Control is turned to or near the night only position (fully counter clockwise to the moon symbol).
If you require another 3 minute Test Period, turn the power off for at least 10 seconds and back on again.
If you require the sensor to operate both in low level light and at night, turn the Photocell Control knob clockwise to the sun symbol. -
Check that lights from other sources, such as adjacent porch lights, garden lights, streetlights or lights from inside the house are not in the sensor’s view. See #1 under “Lights Turn Off Too Quickly”.
-
Was sensor wired hot? If so, circuitry may have been damaged.
-
If sensor is painted, make sure there is no paint on the lens and that the lens paint mask is removed.
Lights Turn Off Too Quickly
-
Check if sensor is being “tricked” by reflected light. If lights shine or reflect into the photocell, (located behind the lens), the unit will go on briefly and turn off thinking it is daytime.
Problem: Lights reflect into photocell or lights shine directly into photocell. Solution: Adjust Photocell Control slightly clockwise, toward the sun symbol. This allows the sensor to function in brighter ambient light conditions. Alternatively, move the lights or mask the lens in the direction of the lights or reflections. If the problem persists, it may be necessary to increase the lenth of the sun shield over the sensor using weatherproof tabe or some other material. -
Check if “R” lamps, “A” lamps or selfballasted PL lamps are being used in a non-enclosed lampholder that can be “seen” by the sensor. If so, switch to reflector PAR floodlight lamps or Quartz floods so the sensor is not affected by stray light. If using PAR floodlights, consider using lower wattage, energy saving lamps.
Self ballasted compact fluorescent lamps may cause the sensor to cycle on and off.
Technical Tips:
Lights Turn On and Off Incorrectly
-
Make sure the sensor is installed on its own dedicated circuit free of motor loads such as HVAC equipment, kitchen appliances or garage door openers.
-
It is not recommended to wire sensors in parallel. More than one sensor wired together makes them difficult to troubleshoot. Disconnect multiple sensors and test separately.
-
Keep all people completely out of the detection pattern to make sure the sensor is not detecting them.
-
Make sure sensor is located below and as far as possible from its lights. Heat from the lights may trigger the sensor.
Solution: Move sensor below and away from the lights. -
Make sure lights are not visible from or reflecting back into sensor. Check for white or reflective surfaces close to the sensor. Solution: Aim sensor away from lights and reflective objects or mask the lens in the direction of the light or reflection.
-
Heavy rain, snow or high winds may activate the sensor occasionally. Solution: Reduce sensitivity control settings, mount in a more protected area and/or mask the lens if this is a constant problem.
-
Make sure sensor is not aimed within 30’ of a road or sidewalk. Passing cars will activate sensor. Solution: Mask the top of the lens to reduce Detection Pattern Length.
-
Self ballasted PL lamps may cause cycling (on-off ).
-
Check solutions 1, 2, 3, 5 & 6 under “Lights Do Not Turn Off” (Pg. 10).
Technical Tips: Lights Turn On For Unknown Reasons
- Lights may turn on occasionally during rain, snow and windstorms because the sensor is detecting changes in temperature. If this is a constant problem, mount the sensor in a more protected area.
- Tilt the sensor lower – it may be seeing distant objects moving.
- You may not be aware that animals have triggered sensor. Check sensor aiming to reduce nuisance triggering or mask the lower part of the lens with opaque weatherproof tape.
- The sensor may turn on occasionally during voltage surges.
- A possible source of “mysterious” sensor activations are strong local radio signals. Check for nearby CB, Ham, VHF radio transmitters or Cellular telephones. The sensor may be activated, but will not be permanently impaired by these signals.
- Check other solutions mentioned under on pages 12 &13.
RAB Sensor Warranty
The SMARTBULLET RAB Sensor will be free from defects in materials and
workmanship for a period of ten (10) years from the date of delivery to the
end-user.
Sensors must be installed by a properly insured and licensed electrician or
under the supervision of a licensed electrician and the product must be in its
original, unopened and new condition at the time of installation. The
information provided in the RAB Sensor Owner’s Manual is critical in
determining the location, conditions, intended use and other requirements with
respect to the use and installation of a sensor product. Using a sensor
product in any manner other than as disclosed in the RAB Owner’s Manual
automatically voids the warranty.
Exceptions. The above warranties shall not apply and RAB makes no
representations or warranties with respect to:
a. problems caused by acts of God including without limitation lightning
strikes; and
b. problems caused by any improper action or failure to act by any person or
entity other RAB, including without limitation problems caused by improper
installation by the buyer, an authorized RAB distributor, or any other person
or entity; and
c. using or installing a sensor product in any manner other than as disclosed
in the RAB Owner’s Manual.
d. use with Instant Start ballasts; use with Instant Start ballasts will void
the RAB warranty. Out of warranty sensors replacement program.
If your sensor is out of warranty or if damage is unrelated to its original
manufacture, return your sensor (freight prepaid and insured) directly to us
(at RAB Lighting Inc. 170 Ludlow Ave. Northvale, NJ 07647) with a check for
$50.00 made payable to RAB Lighting Inc. We will repair or replace your sensor
promptly.
RAB Lighting Product Warranties
The following warranties apply to RAB Lighting, Inc. (“RAB”) products that
meet all of the following conditions: (a) the product was purchased by the
contractor or end-user from an authorized RAB distributor who purchased the
product directly from RAB and from no other source; (b) if the product has
been installed, the entire installation was performed by a licensed
electrician or under the supervision of a licensed electrician and the product
was in its original, unopened and new condition at the time of installation.
RAB LIGHTING DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES WITH RESPECT TO ALL
OTHER PRODUCTS, INCLUDING WITHOUT LIMITATION PRODUCTS THAT HAVE BEEN PURCHASED
FROM ANY PERSON OR ENTITY OTHER THAN AN AUTHORIZED RAB DISTRIBUTOR, OR
INSTALLED BY ANY PERSON OR ENTITY OTHER THAN A LICENSED ELECTRICIAN OR UNDER
THE SUPERVISION OF A LICENSED ELECTRICIAN, AND ALL PRODUCTS THAT ARE USED OR
ARE OTHERWISE NOT IN THEIR ORIGINAL RAB LIGHTING PACKAGING AT THE TIME OF
INSTALLATION.
Remedy. RAB’s obligations for breach of warranty shall be limited to repair or
replacement, at RAB’s option, of any products or parts which prove to be
defective, provided that buyer gives RAB written notice and returns the
defective product to RAB in accordance with RAB’s return material
authorization (RMA) policies, and RAB confirms the defect. Buyer is
responsible for all costs to de-install defective products and re-install
replacement or repaired products and RAB shall not be liable for labor or
other costs related to de-installation or re-installation.
DISCLAIMER. THE FOREGOING WARRANTIES ARE IN LIEU OF, AND RAB EXPRESSLY
DISCLAIMS, ALL OTHER REPRESENTATIONS, GUARANTEES AND WARRANTIES, EXPRESS OR
IMPLIED IN FACT OR BY LAW, INCLUDING WITHOUT LIMITATION ALL WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE. THE
FOREGOING WARRANTIES STATE RAB’S ENTIRE AND EXCLUSIVE LIABILITY, AND BUYER’S
SOLE AND EXCLUSIVE REMEDY, IN CONNECTION WITH THE PRODUCTS AND ALL PARTS,
THEIR DESIGN, SUITABILITY FOR USE, INSTALLATION AND OPERATION.
LIMITATION OF LIABILITY. RAB shall not be liable under any theory of relief,
including without limitation breach of warranty, breach of contract, tort
(including negligence), strict liability, or otherwise, arising out of or
related to any breach of warranty, any RAB products and the use thereof, or
any other acts or omissions of RAB for: (i) any indirect, incidental, special
or consequential damages, whatsoever (including without limitation, loss of
anticipated value of a business or its reputation) or (ii) any damage or loss
in excess of the price actually paid by buyer to the authorized RAB
distributor for the products that caused the damages. Any action by buyer must
be commenced within one year after the cause of action has accrued.
Miscellaneous. These product warranty terms shall be governed by the laws of
the State of New York. Buyer consents to the personal jurisdiction and venue
of the courts of the State of New York. Any legal or equitable claim of any
nature arising hereunder shall be filed and maintained in the state or federal
courts in the State of New York and buyer agrees that such courts are a
convenient forum for adjudication. In the event that suit is necessary to
recover amounts owed RAB, buyer shall be liable for reasonable attorney’s
fees, interest and costs of collection. No agreement or understanding varying
the terms and conditions hereof shall be binding upon RAB or buyer unless in
writing and signed by duly authorized representatives of both parties. These
product warranty terms shall inure to the benefit of and be binding upon the
parties hereto and their respective successors and assigns.
Toll Free Technical Assistance
If you need technical assistance, please do the following:
- Re-read the Technical Tips sections of this manual.
- Call the Tech Help Line at 888 RAB1000, 8AM to 6PM Eastern Time M-F and we will be glad to help you. Before you call, please have the following information handy:
a) Catalog number of your unit;
b) Wattage, types and locations of lights connected to the sensor;
c) The electrical circuit on which the sensor is installed. What else does it feed? How is the sensor power switched?
d) Serial Number (4 digits) on the back of the sensor.
e) This installation Manual
RAB Lighting cannot give electrical wiring instructions by phone. Please
consult a qualified electrician
Note: These instructions do not cover all details or variations in equipment
nor do they provide for every possible situation during installation operation
or maintenance.
©2014 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
SMSBULLET2X12-IN-0314
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>