Specifications
- Item #: 89244/1, 89254/1, 89264/1, 89284/1
- Power: Requires connection to main power supply
- Installation: In accordance with National Electrical Code (NEC) and local code specifications
Product Usage Instructions
Installation
Before starting the installation process, please read and follow the safety warnings provided in the user manual.
- Disconnect power at the main fuse box before installation.
- Carefully pull the house wires out of the junction box to make them easily accessible during installation.
- Position the mounting bracket (A) with the threaded ends of the attached fixture mounting screws (E) facing down towards the floor.
- Pull the house wires through the center hole in the mounting bracket (A) and align the small holes in the mounting bracket with the holes in the junction box.
- Thread each junction box screw (B) into the appropriate hole in the mounting bracket (A) and into the hole in the junction box. Tighten the junction box screws (B) to secure the mounting bracket (A) to the junction box. Make sure the house wires are pulled completely through the hole in the mounting bracket and avoid pinching them between the mounting bracket and ceiling.
- Strip 3/4 of insulation from the ends of fixture wires.
- Slightly loosen the ground screw on the mounting bracket (A). Wrap the house ground wire (copper) around the ground screw, leaving enough ground wire to attach to the fixture ground wire. Twist the end of the fixture ground wire and the end of the house ground wire (copper) together. Twist the wire nut (C) onto the ends of the wires and completely tighten it.
- Twist the end of the house lead wire (black) and the end of the fixture lead wire together. Twist the wire nut (C) onto the ends of the wires and completely tighten it.
- Twist the end of the house neutral wire (white) and the end of the fixture neutral wire together. Twist the wire nut (C) onto the ends of the wires and completely tighten it.
- Wrap electrical tape (not included) around the wire nuts (C) and wires to ensure they are securely fastened.
- Carefully push all wires and wire nuts into the junction box.
Wire Connections
Refer to the chart below for correct wire connections:
Connect Supply (House) Ground Copper Wire to:| Bare Copper Wire or, Bare
Silver Wire or, Green Insulated
Wire
---|---
Connect Black Lead Supply (House) Wire to:| Black Wire or, Parallel Cord
(Round and Smooth)
Connect White Neutral Supply (House) Wire to:| White Wire or, Parallel Cord
(Square and Ridged) or, No printed
words on wire insulation or, Insulated Wire (other than green) with
Copper Conductor
Connect Fixture Lead Wire to:| Black Wire or, Parallel Cord (Round and
Smooth)
Connect Fixture Neutral Wire to:| White Wire or, Parallel Cord (Square and
Ridged) or, No
printed words on wire insulation or, Insulated Wire (other than
green) with Copper Conductor
Connect Fixture Ground Wire to:| Bare Copper Wire or, Bare Silver Wire or,
Green Insulated
Wire
*When parallel wire (SPT 1 & SPT 2) is used: The lead wire is round in shape or smooth. The neutral wire is square in shape or ridged.
Frequently Asked Questions
Q: What should I do if any parts are missing from the box?
A: If anything is missing, please contact the retailer from which the product was purchased.
Q: What is the recommended installation process?
A: The fixture should be installed in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, it is recommended to have the installation done by a certified electrician.
Q: How can I contact customer support?
A: For any questions, you can call our customer support at 800-613-3261 from Monday to Friday, 8:00 AM to 6:00 PM ET.
ANY QUESTIONS CALL: 800-613-3261
M-F 8:00AM-6:00PM ET
- ITEM#: 89244/1
- ITEM#: 89254/1
- ITEM#: 89264/1
- ITEM#: 89284/1
ANY QUESTIONS CALL: 800-613-3261
M-F 8:00AM-6:00PM ET
WARNING: DISCONNECT POWER AT THE MAIN FUSE BOX BEFORE INSTALLATION.
WARNING:
This fixture is intended for installation in accordance with the National
Electrical Code (NEC) and all local code specifications. If you are not
familiar with code requirements, installation by a certified electrician is
recommended.
Before assembly, remove all parts and part packages from box. If anything is
missing, please contact the retailer from which the product was purchased.
INSTALLATION
-
Carefully pull house wires out of junction box so they are easily accessible during installation.
-
Position mounting bracket (A) so threaded ends of attached fixture mounting screws (E) are facing down towards floor.
CAUTION: Make sure house wires are pulled completely through hole in mounting bracket.
DO NOT pinch wires between mounting bracket and ceiling. -
Carefully pull house wires through center hole in mounting bracket (A). Align small holes in mounting bracket (A) with holes in junction box.
-
Thread each junction box screw (B) into appropriate hole in mounting bracket (A) and into hole in junction box. Tighten junction box screws (B) to secure mounting bracket (A) to junction box.
CAUTION: Make sure house wires are pulled completely through hole in mounting bracket.
DO NOT pinch wires between mounting bracket and ceiling. -
Strip 3/4” of insulation from ends of fixture wires.
-
Slightly loosen ground screw on mounting bracket (A). Do not completely remove ground screw. Wrap house ground wire (copper) around ground screw, leaving enough ground wire to attach to fixture ground wire. Twist end of fixture ground wire and end of house ground wire (copper) together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Reference chart below for correct wire connections.
Connect Supply (House) Ground Copper Wire to: -
Bare Copper Wire or,
-
Bare Silver Wire or,
-
Green Insulated Wire.
-
Twist end of house lead wire (black) and end of fixture lead wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Twist end of house neutral wire (white) and end of fixture neutral wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Reference chart to the right for correct wire connections.
-
Wrap electrical tape (not included) around wire nuts (C) and wires. Ensure wires are securely fastened into wire nuts.
-
Carefully push all wires and wire nuts into junction box.
-
Carefully raise fixture up to ceiling. Place canopy (D) of fixture over mounting bracket (A). Pass holes in canopy (D) over ends of fixture mounting screws (E).
-
Screw one threaded cap (F) onto end of each fixture mounting screw (E). Tighten threaded caps (F) to secure fixture to ceiling. DO NOT over tighten.
-
Pass hole in top of shade (K) over socket. Thread socket ring (L) onto socket. Tighten socket ring (L) to secure shade (K) in place. DO NOT over tighten.
-
Screw recommended bulb (E26 Edison bulb type, not included) into socket. Verify correct bulb wattage marked on socket of fixture. WARNING: DO NOT exceed maximum bulb wattage.