RICE LAKE PR5230 Fieldbus Transmitter Instructions
- June 4, 2024
- RICE LAKE
Table of Contents
PR5230 Fieldbus Transmitter
Instructions
PR5230 Fieldbus Transmitter
The Fieldbus transmitter PR5230 is a product for readout and transmitting weight values to installed networks and control systems. The LCD display is configurable and displays up to 10 items, and can be installed at the process. Through the different interface upgrade possibilities and the robust stainless steel housing, the PR5230 is an innovative and flexible process unit.
Specifications (cont.)
Digital Filter for Load Cell:
4th order (low pass), Bessel, aperiodic, or Butterworth.
Ethernet Interface for Optional IP Card:
Ethernet TCP/IP and Modbus ® TCP Definition of an IP address: – AutoIP; – DHCP
Server classification; – manual entering of an IP address.
Automatic detection of signal transmission and corresponding change over
(crossover or patch cable) Webservice via SOAP|UPnP (Simple Object Access
Protocol) Synchronal Modbus UDP.
Serial Interfaces:/strong >
RS 422/485 and RS232
Protocols: Remote Display, SMA, Modbus RTU, printer and Minebea digital scales
(XBPI – protocol)
Options Analogue Output PR 5230/06 (C11):
Ø-1Ø VDC or 4 -2Ø mA, internal resolution 16 bit, usable step width: 0.5 μA
max. load 500 O, user-configurable.
Fieldbus PR 1721/4x (C2x):
Profibus® -DP, Interbus-S, DeviceNet ®, CC-Link, Profinet ®, and EtherNet/IP.
Load Cell Connection Board PR 5230/22 (C31):
For the internal connection of up to 4 Load cells (instead of using a cable
junction box)
Environmental Conditions Temperature:
WandM: –10° C to 40° C
Operation: –10° C to 50° C
Storage: –20° C to 70° C
ATEX Approvals PR 5230:
II 3G Ex nA nC IIC T4
II 3D Ex tD A22 IP6X T80° C
SAG 09ATEX004X
II (2)G [Ex ib] IIC
II (2)D [Ex ibD] KEMA 10 ATEX 0065 X
Standard Features
- IP66, stainless steel, electro-polished construction
- Display for weight and status information
- OIML approval for 10,000e, and an internal resolution of 4 and 8 Mio. counts
- SmartCalibration feature for fast calibration even without weights
- Serial Interface RS-485/422 and RS-232
- Option cards: Analog output 0 to 10 or 4-20 mA, DeviceNet, and Ethernet/IP
- Load cell connection board for up to four load cells
Part Number/Price
Part # | Type | Minebea Part # | Description | Price |
---|---|---|---|---|
158861 | PR5230/00 | 9405 152 30000 | PR5230 transmitter in field housing |
$2,333.00
Options/Accessories
Part # | Type | Minebea Part # | Description | Price |
---|---|---|---|---|
158863 | PR1721/57 | 9405 317 21571 | EtherNet IP interface module | $788.00 |
158864 | PR1721/44 | 9405 317 21441 | DeviceNet interface module | $940.00 |
160431 | PR5230/06 | 9405 352 30061 | 0-10 or 4-20 mA interface module | $313.00 |
APPROVALS
|
---|---
Specifications
Housing:
Housing IP66 material: stainless steel electropolished
RoHS
conform
Dimensions:
(W x D x H): 13.78 x 9.84 x 5.91 in (350 x 250 x 150 mm
Weight:
Net: 1.45 kg (3.2 lb)
Display and Status:
LCD, transflective, back-lit
Weight: 6-digits
Size: 128 + 64 pixels, graphic Information can be configured with Status LEDs
to signal operation and error conditions.
Internal Keys:
In the housing: 3 keys for Zero, Tare, Test
Supply Voltage:
230 VAC, (+10/-15 %): 24 VDC, (±20 %)
Power Consumption: 11 W
Control Outputs:
Quantity: 3Relay output, passive,
Functions: Limits, weight status
Voltage: max. 30 VDC:
Current: max. 30 mA
Control Inputs:
Quantity: 3 Opto-isolated input, passive,
Functions: zero setting, taring
Voltage: max. 30 VDC
Current: max. 10 mA
Remote I/O:
The I/O can be set internally via a function and remote via Fieldbus or PC
In/Output:
All I/O circuits fully galvanically isolated from the sensor input and supply
3 inputs/3 outputs (relays)
Load Cell Connection:
All strain gauge load cells; 6- or 4-wire connection
Load Cell Supply:
12 V, short-circuit proof. External load cell supply possible.
Minimum Load Impedance:
Min. 75 Ω (e.g. 6 load cells with 600 O or 4 loadcells with 350 ohms)
Measuring Principle:
Measuring amplifier: Delta-Sigma converter
Measuring time: min 5 ms – max. 1600 ms
Accuracy:
7.5 nV (appr. 4.8 Mio. div.) Usable resolution: 0.2μV/d
LC Input Signal:
Measuring signal: 0 bis 36 mV (for 100 % nominal load)
Wanda Approval (in preparation):
10,000 e class III acc. to EN 45501; according to.
OIML R76, min. verification interval: 0.5 μV/e at160 ms
Linearity:
< 0.003 %Temperature Effects:
Zero: TK0 m < 0.05 μV/K RTI
Span: TKspan < ±2.5 ppm/K
An ISO 9001 Registered Company © 2021
Rice LakeWeighing Systems 01/21
Prices and specifications are subject to change without notice
Visit ricelake.com for current prices.
References