PANTHER 302577 Power Supply User Manual

June 16, 2024
PANTHER

PANTHER 302577 Power Supply User Manual

PANTHER 302577 Power Supply.jpg

FIG 1.JPG

www.panther.tv

INTRODUCTION

Congratulations to your decision of purchasing or renting your Panther Product. We are pleased that you made your decision in favor of equipment, which combines state-of-the-art technology and many years of experience in manufacturing camera support equipment.

Your new Panther Product is designed to power the equipment that you love working with. To ensure that you will love working with your Panther Product and that all requirements during shooting can be fulfilled considering utmost safety and reliability, please carefully read this user manual.

With our best wishes

BATTERY

GENERAL INFORMATION

With proper use and charging at 20-30° C the battery lifetime is about 2-3 years. Batteries are wear products and therefore not covered by the guarantee or warranty.
Absorbent Glass Mat (AGM) batteries for cyclic use can easily withstand more than 600 cycles at at least 50% discharge before max.capacity falls below 80%.

FIG 3 GENERAL INFORMATION.JPG

AGM Battery: 24V
– Charging time: approx. 5-7 hours
80- 90% = full
27-28,5V = full
– Charge only with suitable 24V charger. We recommend the Panther Charging Station (313165).

Important:
24V = empty
50% = empty
Recharge after use! Do not short Circuit!
Charge this battery during storage at least once a month in order to guarantee a long lifetime!

CAPACITY TESTER

OVERVIEW

This battery capacity tester can test the voltage and capacity of battery, and display them with intuitive battery symbol and percentage. Users can know the state of battery in time.

Remove / Install
The Tester is fixed by buckles, so it is easy to remove / install. Use a flat screw driver to do so.

FIG 5 Remove Install.jpg

FIG 6 Remove Install.jpg

Connecting Cables
This is how you have to connect the cables:

FIG 7 Connecting Cables.JPG

CAPACITY TESTER
USAGE

Functions
The Tester has two functions : F0 and F2. Use the“K+” key on the back to select F0 and F2. Then press the“OK”key on the front, the selected function will run. The default function is F2.

FIG 8 Functions.jpg

F0: Backlight on
Tester run all the time, LCD and backlight always on.

F2: Dormancy
Tester enter a dormancy state (<15uA) after display 10s, LCD and backlight turn off. Press the “OK”key, LCD and backlight turn on 10s.

Display Mode
The Tester has three kinds of display mode. Press the “ K-”key on the back to enter display setting. Use the“K-”key on the back to change the display mode. Then press the “OK”key on the front, the selected mode will run.

FIG 9 Display Mode.jpg

V + % = Voltage and percentage display
The Tester can display the current voltage or the current percentage of capacity. Press the
“OK”key on the front can change the display content.

V = Voltage display
The Tester only displays the current voltage.

% = Percentage display
Tester only displays the current percentage of capacity.

****The Tester cannot be exposed in the sun for a long time or in the environment with large amounts of ultraviolet radiation when using or storing, particular in winter ( -20°C) and summer ( >60°C), otherwise it will shorten the life of the LCD display.

CHARGING

CHARGING STATION

FIG 10 CHARGING STATION.JPG

Charging: Snap-On Battery
Plug in the 1-Way Charge Cable (134643) into the Snap-On battery and into the Charging Station.

FIG 11 Snap-On Battery.JPG

Charging: Slide-In Battery
Slide in the Slide-In Battery on the top side of the Charging Station.

FIG 12 Slide-In Battery.JPG

Charger for AGM batteries
Built-in 3 stage programmable charging curve Fanless design, cooling by free air convection
Protection: Short circuit / Over voltage / Over temperature / Battery under voltage / Battery over voltage / Battery reverse polarity protection

FIG 13 Charger for AGM batteries.jpg

FIG 14 Charger for AGM batteries.jpg

Front Panel LED Indicators

FIG 15 Front Panel LED Indicators.JPG

SAFETY

Safety Guidelines

  • Do not use in wet or humid conditions
  • The cables between charger and battery should be kept as short as possible to prevent excessive voltage drop (suggested cable length: 50cm – 100cm). Too much voltage drop will lead to longer charging period.
  • Temperature raising on case during charging is a normal behavior.
  • Dismantling or changing components of the charger is forbidden.
  • Charger should be in the OFF mode before making battery connection or disconnection.

The charger provides a DIP switch behind the panel used to switch different factory charging parameters. Please refer to the table below for corresponding curves on different positions of the DIP switch.

FIG 16 Safety Guidelines.JPG

General Operation

At the beginning stage of operation, the charger provides the largest current with 28.8V dc of output voltage to charge batteries, the LED indicator will flash in orange. After a period of time
(probably a couple of hours) the charging current will decrease gradually.
After reducing to 10% of its maximum value, the charger will go into „float charge“ stage.
Output voltage will drop to 27.6V and the LED indicator can flash in green.

Troubleshooting

FIG 17 Troubleshooting.JPG

NOTES

FURTHER ASSISTANCE

If you need any further assistance with this instructions (or also other questions) please contact our service department.

FIG 18 FURTHER ASSISTANCE.JPG

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals