REVOPOINT RANGE 2 3D Scanner User Guide Revopoint RANGE 2 3D Scanner

January 21, 2024
REVOPOINT

RANGE 2 3D Scanner

Revopoint RANGE 2 3D Scanner

Specifications

  • Operating environment temperature range: 0°C to 40°C (32°F to
    104°F)

Product Profile

The Revopoint RANGE 2 3D Scanner is a high-quality scanner that
allows you to capture detailed 3D scans of objects. It is designed
for both professional and personal use.

System Requirements

To use the Revopoint RANGE 2 3D Scanner, you will need to ensure
that your device meets the following system requirements:

  • Windows: Win 10/11 (64-bit), RAM: 8GB or
    better, Processor: Intel Core i5 10th Gen or better

  • Mac with Intel x86 chip: macOS 10.15 and
    models after, RAM: 8GB or better

  • Mac with Apple M1/M2 chip: macOS 11.0 and
    models after, RAM: 8GB or better

  • Android: Android 9.0 or better, RAM: 6GB or
    better

  • iPhone: iPhone 8 Plus or models after

  • iPad: 6th generation iPad or models after,
    System Version: iOS 13.0 or better

Connecting the RANGE 2 Scanner

I. Connecting RANGE 2 to a PC via USB Cable

Follow these steps to connect the scanner to a PC via USB:

  1. Connect the Tripod to the scanner.

  2. Use the USB Type-A to C Cable to connect the scanner to a PC.
    When the scanner’s indicator turns solid green, it’s powered. If
    your PC does not have a USB Type-A port, use the USB Type-C
    Adapter.

  3. Open Revo Scan software. When the software shows “Scanner
    Connected” and the scanner’s indicator turns solid blue, it’s
    ready.

II. Connecting RANGE 2 to a PC via Wi-Fi

Follow these steps to connect the scanner to a PC via Wi-Fi:

  1. Screw the scanner onto the Power Bank Handle.

  2. Use the USB Type-A to C Cable to connect the scanner and Power
    Bank Handle. When the scanner’s indicator turns solid green, it’s
    powered.

  3. Search for a Wi-Fi network called “RANGE 2-REVO-XXXXXXXX” in
    your PC’s Wi-Fi settings, and connect (no password is
    required).

  4. Open Revo Scan software. When the software shows “Scanner
    Connected” and the scanner’s indicator turns solid blue, it’s
    ready.

III. Connecting RANGE 2 to Android Phones via USB Cable

Follow these steps to connect the scanner to Android phones via
USB:

  1. Attach the Quick Release Plate, Phone Holder, and Power Bank
    Handle to the scanner.

  2. Put a phone in the Phone Holder, and use the 2-in-1 Mobile
    Cable to connect to the ports shown. When the scanner’s indicator
    turns solid green, it’s powered. Note: The 2-in-1 Mobile Cable can
    only be used to connect the scanner and phones.

  3. Open Revo Scan software. When the software shows “Scanner
    Connected” and the scanner’s indicator turns solid blue, it’s
    ready.

IV. Connecting RANGE 2 to Android or iOS Phones via Wi-Fi

Follow these steps to connect the scanner to Android or iOS
phones via Wi-Fi:

  1. Attach the Quick Release Plate, Phone Holder, and Power Bank
    Handle to the scanner.

  2. Put a phone in the Phone Holder, and use the USB Type-A to C
    Cable or 2-in-1 Mobile Cable to connect the scanner to the Power
    Bank Handle. When the scanner’s indicator turns solid green, it’s
    powered.

  3. Open Revo Scan software. When the software shows “Scanner
    Connected” and the scanner’s indicator turns solid blue, it’s
    ready.

FAQ

Q: Where can I download the Revo Scan software?

A: For Windows and macOS users, visit the Support section on
Revopoint’s website at www.revopoint3d.com to download.
Smartphone users can find Revo Scan on Google Play or the Apple App
Store to download.

Q: What is the operating environment temperature range for this

product?

A: The operating environment temperature range for the Revopoint
RANGE 2 3D Scanner is 0°C to 40°C (32°F to 104°F).

RANGE 2 3D SCANNER
Quick Start Guide
V1.0

Thank you for choosing the Revopoint 3D scanner! Please carefully read this guide before your first scan.
Begin by downloading the Revo Scan software for your RANGE 2 3D Scanner. For Windows and macOS users, visit the Support section on Revopoint’s website at www.revopoint3d.com to download. Smartphone users, find Revo Scan on Google Play or the Apple App Store to download.
Please keep the scanner away from water and any other liquids, and avoid bashing the scanner. This product’s operating environment temperature range is 0 to 40 (32 to 104 ). Please
operate the product appropriately and only in situations limited to this temperature range.

Table of Content
What’s in the Box?……………………………………………………………………………………………………………………………………………………………………………..1 Product Profile……………………………………………………………………………………………………………………………………………………………………………………2 System Requirements ……………………………………………………………………………………………………………………………………………………………………3 Scanner Connection ……………………………………………………………………………………………………………………………………………………………………… 3
I. Connecting RANGE 2 to a PC via USB Cable……………………………………………………………………………………………………………… 4 II. Connecting RANGE 2 to a PC via Wi-Fi…………………………………………………………………………………………………………………………5 III. Connecting RANGE 2 to Android Phones via USB Cable……………………………………………………………………………………. 7 IV. Connecting RANGE 2 to Android or iOS Phones via Wi- Fi………………………………………………………………………………… 9 Scanning Tips …………………………………………………………………………………………………………………………………………………………………………………….11 Your First Scan………………………………………………………………………………………………………………………………………………………………………………….13 I. Your First Scan Using Revo Scan (PC)………………………………………………………………………………………………………………………….13 II. Your First Scan Using Revo Scan (Android)……………………………………………………………………………………………………………..15 III. Your First Scan Using Revo Scan (iOS)………………………………………………………………………………………………………………………18 Sharing Models from a Phone to a PC………………………………………………………………………………………………………………………….. 20

What’s in the Box?
1

Product Profile
2

System Requirements

Please download the Revo Scan software before your first scan. The system requirements are as follows:

Windows: Win 10/11 (64-bit) RAM: 8GB or better Processor: Intel Core i5 10th Gen or better Mac with Intel x86 chip: macOS 10.15 and models after Mac with Apple M1/M2 chip: macOS 11.0 and models after RAM: 8GB or better

Android: Android 9.0 or better RAM: 6GB or better
iPhone: iPhone 8 Plus or models after iPad: 6th generation iPad or models after System Version: iOS 13.0 or better

Scanner Connection

Connection Modes

System

PC

Phone

Mode

Windows

macOS

Android

iOS

USB

×

Wi-Fi

3

I. Connecting RANGE 2 to a PC via USB Cable
Step 1: Connect the Tripod to the scanner.
Step 2: Use the USB Type-A to C Cable to connect the scanner to a PC. When the scanner’s indicator turns solid green, it’s powered.
Note: If your PC does not have a USB Type-A port, use the USB Type-C Adapter.
4

Step 3: Open Revo Scan, when the software shows Scanner Connected and the scanner’s indicator turns solid blue, it’s ready.
II. Connecting RANGE 2 to a PC via Wi-Fi
Step 1: Screw the scanner onto the Power Bank Handle.
5

Step 3: Search for a Wi-Fi network called RANGE 2-REVO-XXXXXXXX in your PC’s Wi-Fi settings, and connect (no password is required).

Step 2: Use the USB Type-A to C Cable to connect the scanner and Power Bank Handle. When the scanner’s indicator turns solid green, it’s powered.
6

Step 4: Open Revo Scan, when the software shows Scanner Connected and the scanner’s indicator turns solid blue, it’s ready.
III. Connecting RANGE 2 to Android Phones via USB Cable
Step 1: Attach the Quick Release Plate, Phone Holder, and Power Bank Handle to the scanner.
7

Step 3: Open Revo Scan, when the software shows Scanner Connected and the scanner’s indicator turns solid blue, it’s ready.

Step 2: Put a phone in the Phone Holder, and use the 2-in-1 Mobile Cable to connect to the ports shown. When the scanner’s indicator turns solid green, it’s powered.
Note: The 2-in-1 Mobile Cable can only be used to connect the scanner and phones.
8

IV. Connecting RANGE 2 to Android or iOS Phones via Wi-Fi
Step 1: Attach the Quick Release Plate, Phone Holder, and Power Bank Handle to the scanner.
Step 2: Put a phone in the Phone Holder, and use the USB Type-A to C Cable or 2-in-1 Mobile Cable to connect the scanner to the Power Bank Handle. When the scanner’s indicator turns solid green, it’s powered.
9

Step 3: Search for a Wi-Fi network called RANGE 2-REVO-XXXXXXXX in your smartphone’s Wi-Fi settings, and connect (no password is required).
Step 4: Open Revo Scan, when the software shows Scanner Connected (iOS devices will show the scanning preview window) and the scanner’s indicator turns solid blue, it’s ready.
10

Scanning Tips
Please scan indoors and ensure only the object to be scanned is shown in the Depth Cameras’ preview window. Use the Large Calibration-board Sheet to help if necessary. Ensure the object is evenly lit if you need a color model.
Use scanning spray when scanning transparent, dark, and reflective objects.
Note: Scanning spray can be purchased from the Revopoint Store on our website.
Please stick markers irregularly on the object’s surface or use the Magic Mat when scanning featureless objects like balls and cylinders, and choose Marker Tracking in Scan Settings – Tracking Mode in Revo Scan.
11

Please aim the scanner at the object to be scanned, hold it steady and move slowly during your scan. The distance between the scanner and the object can be between 400 ­ 1300 mm. In the 3D scanning interface in Revo Scan, refer to the distance indicator bar to ensure an excellent distance between the scanner and the object.
Note: The scanning accuracy may be affected if the scanner is bashed by accident. In this case, please get in touch with us to help you recalibrate the scanner with the Calibration Board. If the accuracy still cannot reach the standard accuracy after recalibration, please return the scanner for repair.
12

Your First Scan
I. Your First Scan Using Revo Scan (PC) After the scanner is connected, click the New Project button on Revo Scan’s Home Page, then set parameters and start your scan using the following steps:
Please refer to the interface of Revo Scan. 13

Choose Accuracy, Tracking Mode, and Object Type according to your requirements.

Toggle Color Scanning if you need a color model.

Move the scanner closer or further away from the object until the scanning distance indicator bar shows Excellent or Good.

Click the

button for the Depth Cameras’ exposure to be set automatically, or you can turn off

the

exposure and change the exposure by dragging the slider until there are as few blue and

red areas on the object in the Depth Camera preview window as possible.

You also must adjust the RGB Camera’s exposure when doing a color scan. Click the

button

for the exposure to be set automatically, or you can turn off the

exposure and adjust the

exposure by dragging the slider until the object’s color in the RGB preview window is clear and

sharp.

Click the

button to begin your scan. While scanning, hold the scanner steady and move

slowly. Try not to scan the same areas repeatedly. You can click the

button to stop and

check your model anytime during your scan. If the model is incomplete, click the

button to

continue your scan. Click the

button to finish the scan when the model is complete.

Click One-click Edit to process the model automatically, or manually edit the model using the Fusion, Mesh, Texture (only for color models) settings, and other tools if you need a more detailed model.

After post-processing, export the model in PLY, OBJ, or STL formats.

14

II. Your First Scan Using Revo Scan (Android)
Open Revo Scan on your phone and tap the New Project button. Choose Accuracy, Tracking Mode, and Object Type according to your needs. Choose Color in
Texture if you need a color model. Tap the Start Scanning button to enter the scanning preview window.
15

Move the scanner closer or further away from the object until the scanning distance indicator bar shows Excellent or Good.

Tap the icon in the Depth Camera preview window to adjust the Depth Cameras’ exposure until there are as few blue and red areas on the object in the preview window as possible.

You must also adjust the RGB Camera’s exposure when doing a color scan. Tap the

icon in the

RGB Camera preview window and adjust the exposure until the object’s color in the preview window

is clear and sharp.

Tap the

icon to start scanning. While scanning, hold the scanner steady and move slowly. Try

not to scan the same areas repeatedly. Tap the

button to finish the scan and enter the

post-processing window when the scan is over.

16

Tap the

icon to fill holes in the model (optional).

Tap the Post-processing button for Fusing and Meshing. You can share the model to Revo Scan on your PC for more editing options. See Sharing Models from a Phone to a PC on page 20 of this guide for details.

17

III. Your First Scan Using Revo Scan (iOS)

Tap the

icon to choose Accuracy, Tracking Mode, and Object Type. Toggle Color Scanning if

you need a color model.

Move the scanner closer or further away from the object until the scanning distance indicator bar shows Excellent or Good.

Tap the

button for the Depth Cameras’ exposure to be set automatically, or you can turn off

the

exposure and change the exposure by dragging the slider until there are as few blue

and red areas on the object in the Depth Camera preview window as possible.

18

You also must adjust the RGB Camera’s exposure when doing a color scan. Tap the

button

for the exposure to be set automatically, or you can turn off the

exposure and adjust the

exposure by dragging the slider until the object’s color in the RGB preview window is clear and

sharp.

Tap the

button to start your scan. While scanning, hold the scanner steady and move slowly.

Try not to scan the same areas repeatedly.

Tap the

button to finish the scan and enter the post-processing window when the scan is over.

Tap the

icon to fill holes in the model (optional).

Tap the Post-processing button to automatically process the model. You can share the model to Revo Scan on your PC for more editing options.

19

Sharing Models from a Phone to a PC

Open Revo Scan on your PC and click the New Project button.
Choose File – Import from Phone on the Menu Bar.
Open Revo Scan on your phone and find the project to transfer.
Tap the share icon and enter the share page (see the image on the right).
Enter the code or scan the QR code displayed on the PC.
Wait for the project to be transferred.

Note: The phone and PC must be connected to the same network while transferring.

To learn more scanning skills, go to the Download page in the Support section on Revopoint’s website, www.revopoint3d.com, to get the latest Quick Start Guide and User Manual. You can also follow our YouTube account, Revopoint 3D, for tutorial videos. This content is subject to change. Please refer to the latest version.
20

Follow Us:

Contact Us:

Scan the QR code left with your phone and contact us for help.

©2023 REVOPOINT 3D ALL RIGHTS RESERVED

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals