LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide

June 16, 2024
LILLIPUT

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User
Guide

Important Safety Instructions:

  • Please read User Guide before using this product.
  • Please keep User Guide for future reference.
  • Please read the precaution to prevent possible danger and loss of property.

Precaution:

  • Please do not place the display screen towards the ground.

  • Please avoid heavy impact or drop onto the ground. Please do not use chemical solutions to clean this product.

  • Please wipe with a clean soft cloth to maintain the brightness of the surface.

  • Please do not block any vent hole.

  • Please follow the instructions and trouble-shootings to adjust the product. Other improper adjustment
    may result in damage. Any further adjustment must be performed or conducted by a qualified technician.

  • Please unplug the power and remove the battery if long-term no-use, or thunder weather.

1. Production Description

1.1 Front Panel

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide - Front
Panel

  1. Earphone Jack

  2. POWER: Power ON/OFF.

  3. SDI: Signal switch to SDI mode when light on.

  4. HDMI: Signal switch to HDMI mode when light on.

  5. MENU
    – Press to enter menu.
    – Press to enter option in the menu.

  6. < – Select option in the menu.
    – Decrease the option value. Before enter the menu, single press to activate function bar, press again to switch among of volume, brightness, contrast, color, hue, sharpness and backlight.

  7. – Select option in the menu.
    – Increase the option value.

  8. Exit Button

  9. F1~F3 User definable buttons
    Assigned function by factory as follow: [F1]: MV Mode [F2]: Waveform [F3]: Level Meter (Long press any F1-F2-F3 buttons for 3-5 seconds to custom options)

1.2 Rear Panel
1.2.1 Interfaces

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide -
Interfaces

  1. 12V DC power port.
  2. USB port.
  3. TALLY connecter.
  4. LAN port. (Connected to PC network interface for function adjustment.)
  5. HDMI 2.0 input port.
  6. HDMI 2.0 output port.
  7. 4×12G-SDI input/output ports.

2. Menu Setting

Before setting the functions, please make sure the device is connected correctly.

2.1 Shortcut keys
2.1.1 Function Menu

Under non menu screen, press < or > buttons to activate function bar, and then press the “MENU” button can activate the shortcut menu bar to select brightness, contrast, saturation, tint, sharpness, volume, back light. Use the

< or > button to adjust the value. Default function is [Back Light].
2.1.2 F1-F2-F3 Buttons:
  • Long press any F1-F2-F3 buttons for 3-5 seconds to pop up shortcut menu on the screen. As shown in Figure. Select option via < and > key, and set it as default via pressing the Menu button, then press Exit button to exit shortcut setting menu.
  • Functions of F1-F2-F3 buttons can also be customized: [Center Marker], [Aspect Marker], [Safety Marker], [Overscan], [Scan], [Aspect], [Color Space], [HDR], [Gamma], [Camera Log], [Check Field], [H/V Delay], [Freeze], [Image Flip], [Color Bar], [Peaking], [False Color], [Exposure], [Histogram], [Full Mode], [Waveform], [Time Code], [Audio Source], [Mute], [Lever Meter], [MV Mode]. (PS: Time Code only available on SDI mode.)
  • Default function:
    F1: [MV Mode] F2: [Waveform].
    F3: [Level Meter]
2.2 MENU Operations
2.2.1 PICTURE

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide -
PICTURE

  • Brightness
    Control the degree of brightness between 0-100.

  • Contrast
    Control contrast ratio between 0-100.

  • Saturation
    Adjust the color intensity between 0-100.

  • Tint
    Adjust tint between 0-100.

  • Sharpness
    Control sharpness of the image between 0-100.

  • Back Light
    Adjust the level of the back light from 0 to 100.

  • RGB Range
    Use this item to choose the RGB range of the HDMI input: [Full], [Limited].
    Only available on HDMI mode.

  • HDMI EDID
    Select the HDMI EDID from between [4K] and [2K]. This item enables PC or other devices to recognize
    the property of this monitor and makes the images look excellent on the screen.
    PS: Only available on HDMI mode.

  • Color Space Select the display gamut from among [Native], [SMPTE-C], [Rec709], [EBU].

  • Camera Log Use this item to choose one of the camera Log modes: – [Off]: Turn off Camera Log. – [Def. Log]: Use this item to choose one of the Camera Log modes as the following sequence: [SLog2ToLC-709], [SLog2ToLC-709TA], [SLog2ToSLog2-709], [SLog2ToCine+709], [SLog3ToLC-709], [SLog3ToLC-709TA], [SLog3ToSLog2-709], [SLog3ToCine+709], [ArriLogCTo709], [ArriLogCToP3DCI], [CLogTo709], [VLogToV709], [JLogTo709], [JLogTo709HLG], [JLogTo709PQ], [Z7 NLogTo709], [D780 NLogTo709]

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide - Camera
Log

– [User Log]: Use this item to choose one of the User Log modes (1-6). Please install the User Log as following steps: The User Log must be named with. Cube in the suffix. Please note: the device only supports the format of User Log: 17x17x17 / 33x33x33; Data order is BGR; Table order is BGR. If the format does not meet the requirement, please use tool “Lut Tool.exe” to transform it. Naming the User Log as User1-User6.cube, then copy the user Log into USB flash disk. Insert the USB flash disk to the device, the User Log is saved to the device automatically at the first time. If the User Log is not loaded for the first time, the device will pop up a prompt message, please choose whether to update or not.

  • Gamma Use this item to choose the display Gamma: [Off], [1.8], [2.0], [2.2], [2.35], [2.4], [2.6], [2.8].

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide -
Gamma

Note: Gamma mode can be only activated while HDR function closed.

  • HDR
    Use this item to choose one of the HDR presets: [Off], [ST 2084 300], [ST 2084 1000], [ST 2084 10000], [HLG].

  • Color Temp.
    Use this item to choose one of the color temperature presets: [5500K], [6500K], [7500K], [9300K], [User].
    PS: Only available under [User] mode to adjust R/G/B Gain and Offset.

  • R/G/B Gain
    Adjust the R/G/B Gain of the current Color Temperature from 0 to 255. Default value: 128.

  • R/G/B Offset
    Adjust the R/G/B Offset of the current Color Temperature from 0 to 511. Default value: 256

2.2.2 MARKER
  • Center Marker Select [On] to display the center marker “+” and [Off] not to display it.

  • Aspect Marker Select the aspect ratio of the marker: [Off], [16:9], [1.85:1], [2.35:1], [4:3], [3:2], [1.3X], [1.5X], [2.0X], [2.0X MAG], [Grid].
    PS: When [Aspect Marker] is selected as [Grid], Safety Marker and Aspect Mat cannot be displayed.

  • Safety Marker Select [Off] not to display the safety marker. When this item is used with the Aspect Marker, it is only in Aspect Marker. When [Aspect Marker] is selected as [User], the safety marker does not be changed. Select the size of the safety markers: [95%], [93%], [90%], [88%], [85%], [80%].

  • Marker Color Select the color of marker displayed on the screen: [Red], [Green], [Blue], [White], and [Black].

  • Aspect Mat. When activated, it can be selected from 1-7 (Step value is 1).LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide - Aspect Mat

  • Thickness Adjust the thickness of all the marker lines from 1-7 (Step value is 1).

2.2.3 DISPLAY
  • MV Mode
    MV1 Source: SDI1/ SDI2/ SDI3/ SDI4/ HDMI signal input
    MV2 Source: SDI1/ SDI2/ SDI3/ SDI4/ HDMI signal input
    MV3 Source: SDI1/ SDI2/ SDI3/ SDI4/ HDMI signal input
    MV4 Source: SDI1/ SDI2/ SDI3/ SDI4/ HDMI signal input
    Frame Line Width: Off, 2, 4, 6, 8, 10, 12, 14
    MV1 Frame Line Color: White, Red, Green, Blue, Yellow
    MV2 Frame Line Color: White, Red, Green, Blue, Yellow
    MV3 Frame Line Color: White, Red, Green, Blue, Yellow
    MV4 Frame Line Color: White, Red, Green, Blue, Yellow

  • UMD
    UMD: Off, On
    UMD 1 Text Color: White, Red, Green, Blue, Yellow, Cyan, Magenta
    UMD 2 Text Color: White, Red, Green, Blue, Yellow, Cyan, Magenta
    UMD 3 Text Color: White, Red, Green, Blue, Yellow, Cyan, Magenta
    UMD 4 Text Color: White, Red, Green, Blue, Yellow, Cyan, Magenta
    PS: When [MV Mode] is turned on, UMD be selected.

  • Scan
    Adjust the scan mode among [Aspect], [Pixel To Pixel].

  • Aspect
    Select the aspect of the image among [Full], [16:9], [1.85:1], [2.35:1], [4:3], [3:2], [1.3X], [1.5X], [2.0X], [2.0X MAG].

  • Over scan
    Use this item to activate or deactivate over scan.

  • H/V Delay
    Select one of the H/V modes: [OFF], [H], [V], [H/V]. When H/V Delay on, the blanking portions of the input signal will be displayed horizontally and vertically.

  • Check Field
    Select one of check field modes: [Off], [Red], [Green], [Blue], [Mono].

  • Freeze Choose [On] to capture one frame of current image on the screen, and choose [Off] to close freeze function.

2.2.4 WAVEFORM

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide -
WAVEFORM

  • Full Mode Use this item to activate Full Mode: [Off], [Y], [YCbCr], [RGB], [Vector], [Histogram], [Audio].

  • Waveform
    Use this item to activate or deactivate Waveform. Select the waveform mode from among [Off], [Y],
    [YCbCr], and [RGB].
    – [Y]: Display Y Waveform.
    – [YCbCr]: Display YCbCr Waveform.
    – [RGB]: Display R/G/B Waveform.

  • Vector
    Use this item to activate or deactivate Vector.
    PS: The Vector function is not available in Quad Mode.

  • Transparency
    Adjustment of transparency can support waveform, vector, histogram, level meter.
    Transparency can be selected from among [off], [25%], and [50%].
    – [Off]: The background of waveform is shown at black.
    – [25%]: The background of waveform is shown at 25% intensity.
    – [50%]: The background of waveform is shown at 50% intensity.

  • Peaking
    Use this item to activate or deactivate the peaking function.

  • Peaking Color
    Select one of the peaking colors: [Red], [Green], [Blue], [White], and [Black].

  • Peaking Level Use this item to adjust the level of peaking from 1-100. The higher peaking level is, the more obvious peaking effect is.

  • False Color Use this item to activate or deactivate the false color function. When activated, [Default], [Spectrum], [ARRI], [RED] are for optional.

  • False Color Table Use this item to activate or deactivate the false color table.

  • Exposure Use this item to activate or deactivate the exposure function.

  • Exposure Level Use this item to adjust the level of exposure between 50-100 IRE.

  • Histogram Use this item to activate or deactivate histogram.

  • Time Code Use this item to activate or deactivate the Time Code. When activated, [LTC], [VITC] are for optional. PS: Time code is only available under SDI mode.

2.2.5 AUDIO
  • Volume Adjust the volume among 0-100.
  • Audio Ch In HDMI mode, select the audio channels from among [Ch1&Ch2], [Ch3&Ch4], [Ch5&Ch6] and [Ch7&Ch8]. In SDI mode, select the audio channels from among [Ch1&Ch2], [Ch3&Ch4], [Ch5&Ch6], [Ch7&Ch8], [Ch9&Ch10], [Ch11&Ch12], [Ch13&Ch14] and [Ch15&Ch16].
  • Level Meter Select whether to activate or deactivate level meter.
2.2.6 SYSTEM

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide -
SYSTEM

  • Language Option: [Chinese], [English].

  • Color Bar
    Turn on/off color bar. When the color bar on, it can be selected: [100%], [75%].

  • -OSD Timer
    Option: [10s], [20s], [30s].

  • OSD Transparency
    Turn on/off OSD transparency. When OSD Transparency on, option: [25%], [50%].

  • OSD H Position
    Option: 0-100. Default: 50.

  • OSD V Position
    Option: 0-100. Default: 50.

  • Color Calibration
    Select [On] or [Off].
    If the device needs to be calibrated color, please operate as following:
    1. Connect the device with the PC via HDMI interface.
    2. Make sure the device and color calibration equipment to work more than 30 minutes.
    3. After the previous step, activate the Color Calibration function of the device and color calibration software to calibrate the color (See the document “CMS Color Calibration Process” for details).
    4. It will generate a document “Rec709.cube” after calibrated, then copy this document to USB flash disk.
    5. Insert the USB flash disk to the device and save the document. This document “Rec709.cube” will be found under Color Space Option.
    PS: It is not available under Quad mode.

  • Comparison En
    Use this setting to activate or deactivate the Comparison En function.
    When activated, the screen displays the comparison of Original image and customized image, as shown:

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide -
Comparison En

Option: [Off], [Gamma/HDR], [Color Space], [Camera Log]. Default: [Off].
PS: It is not available under Quad mode.

  • DHCP
    – [On]: The monitor will automatically get an IP address from network for remote control via various programs.
    – [Off]: Manually configure IP address.

  • IP Address
    Manually configure IP address: xxx.xxx.xxx.xxx
    PS: When [DHCP] on, IP address cannot be manually set.

  • Subnet Mask
    Manually configure Sub net Mask: xxx.xxx.xxx.xxx
    PS: When [DHCP] on, Subnet Mask cannot be manually set.

  • Gateway
    Manually configure Gateway: xxx.xxx.xxx.xxx
    PS: When [DHCP] on, Gateway cannot be manually set.

  • No Signal Mode
    Option: [Normal], [Shutdown], [Sleep].

  • Reset
    Select the Reset option, press the Menu button to automatically reset.

3. Product Parameters

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide - Product
Parameters

4. Accessories

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide -
Accessories

Standard:

  1. 12V DC adapter. 1 pc
  2. Tally adapter. 1 pc
  3. User Manual. 1 pc

5. Trouble Shooting

  1. Only black-and-white display: Check whether the color saturation is properly setup or not.
  2. Power on but no pictures: Check whether the cables of SDI and HDMI are correctly connected or not. Please use the standard power adapter coming with the product package. Improper power input may cause damage.
  3. Wrong or abnormal colors: Check whether the cables are correctly and properly connected or not. Broken or loose pins of the cables may cause a bad connection.
  4. When on the picture shows size error: Press “MENU FUNCTION Over scan” to zoom in/out pictures automatically when receiving HDMI signals.
  5. Other problems: Please press “MENU” button and choose “MENUSYSTEM Reset On”.
    PS: Due to constant effort to improve products and product features, specifications may change without notice.

Appendix 1: 3D LUT Loading

3D LUT supports upload color calibration document and User Log via USB flash disk.

  • Format Requirement

    • LUT format
      Type: .cube
      3D Size: 17x17x17/33x33x33
      Data Order: BGR
      Table Order: BGR

    • USB flash disk version
      USB: 2.0
      System: FAT32
      Size: <16G

    • LUT format Color calibration document: Rec709. cube

    • User Log: User1. cube-User6.cube

  • LUT Format conversion
    Please convert LUT format according to the following steps. PS: For Mac users, please copy the “mac OS” file to Mac, then click and follow the steps below.

    • Activate Lut converterLILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide - LUT Format conversion
      One individual Product ID for one computer. Please send the ID number to Sales to get an Enter Key. Then the computer gets the permission of the Lut Tool after input the Enter Key.

    • Light Space CMS software user demo

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide -
LightSpace CMS software user demo LILLIPUT RM1731S-12G
17.3 Inch 1RU Rack Mount Monitor User Guide - LightSpace CMS software user
demo

  • USB Loading
    Copy the needed files to the root directory of the USB flash disk. Plug the USB flash disk into USB port of the device after power on. Click “Yes” on the pop-up prompt window (If the device doesn’t pop-up the prompt window, please check the LUT document name or the USB flash disk version), then press Menu button to update automatically. It will pop-up a prompt message if the update completed.

Appendix 2: Remote Terminal Instructions

  • Cross-connection network cable
  1. Connect LAN Port on the device to PC network interface by using network cable. 2) Manually configure the IP of the computer which the monitor needs to connect to: xxx.xxx.xxx.xxx
  2. Install the Net framework The device uses OS Win 8 and above do not need to be installed as it ships with this framework.
    PS: The device uses OS below Win 8 need to be pre-installed framework “dotNetFx40_Full_x86_x64.exe”.
  • Software Interface
    1 Software Setup Open the software, it displays related IP address on the left of pop-up window if the device is connected successfully.

LILLIPUT RM1731S-12G 17.3 Inch 1RU Rack Mount Monitor User Guide - Software
Interface

2) Introduction

  1. Source Area:
    To check and setup the selected Source. The settable parameters will be different for different Sources.

  2. Device Area:
    The software will read the data from the device. After selection, the user can change the Settings to setup the selected device.

  3. Refresh Button:
    Click to refresh connected device. The display screen will display the IP address.

  4. Copy & Paste Button:
    Using Copy Button with Paste Button to read and save data get from the device which IP address marks as blue. The copied data can be saved until the process closed.
    After copy the data from the display device, click Paste Button to save it. The data can be sent to select multiple devices.

  5. Parameter Zone:
    The Parameter Zone includes Picture, Marker, Function, Source, Audio, and UMD. See the software interface for the details.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals