SCHMERSAL 17-11ZK-ST-2493 Safety Switch Separate Actuator Instruction Manual

June 16, 2024
SCHMERSAL

SCHMERSAL 17-11ZK-ST-2493 Safety Switch Separate Actuator

SCHMERSAL-17-11ZK-ST-2493-Safety-Switch-Separate-Actuator-
PRODUCT

Specifications

  • Product Name: Safety switch with separate actuator AZ 17-11ZK-ST-2493
  • Function: Provides information and instructions for mounting, set-up, commissioning, operation, and disassembly of the switchgear
  • Target Group: Authorised qualified personnel
  • Appropriate Use: The product is designed for use in safety-related functions as part of an entire plant or machine
  • General Safety Instructions: The user must observe the safety instructions in the operating instructions manual, country-specific installation standards, and all prevailing safety regulations and accident prevention rules

Product Description

  • Ordering Code: AZ 17-11ZK-ST-2493
  • Special Versions: N/A
  • Purpose: The safety switch with separate actuator is designed to ensure safe operation and disassembly of the switchgear
  • Warning about Misuse: Users must be aware of the potential risks and follow the appropriate guidelines to prevent misuse
  • Exclusion of Liability: The information provided in this operating instructions manual is without liability and subject to technical modifications
  • Technical Data: Detailed technical specifications can be found in the product documentation

Mounting

General Mounting Instructions

The general mounting instructions provide guidance on how to install the safety switch with separate actuator. It is important to follow these instructions carefully to ensure proper installation and functionality.

Dimensions

The dimensions of the safety switch with separate actuator are specified in the product documentation. These dimensions should be considered during the installation process to ensure proper fit and compatibility with the existing setup.

Mounting of the Actuator

The actuator of the safety switch needs to be mounted according to the instructions provided in the product documentation. This includes aligning and securing the actuator in the correct position for optimal performance.

Electrical Connection

General Information for Electrical Connection

The electrical connection of the safety switch should be performed by qualified personnel following all applicable electrical safety standards and regulations. The product documentation provides detailed instructions on how to make the electrical connections.

Contact Options

The safety switch may have different contact options depending on the specific model and application. The product documentation provides information on the available contact options and how to select and configure them according to the desired functionality.

Set-up and Maintenance

The set-up and maintenance procedures for the safety switch are crucial for ensuring its proper operation and longevity. The product documentation provides detailed instructions on how to set up and maintain the switch, including any necessary adjustments or periodic checks.

Disassembly and Disposal

Disassembly

If disassembly of the safety switch is required, it should be done following the instructions provided in the product documentation. This ensures safe disassembly without causing any damage to the components or surrounding equipment.

Disposal

When disposing of the safety switch or its components, it is important to follow proper disposal procedures according to local regulations and guidelines. The product documentation may provide specific instructions on how to dispose of the switch or its components in an environmentally friendly manner.

FAQ

Q: Can the safety switch be used by private consumers?

A: No, the Schmersal range of products is not intended for private consumers. It is designed for use in industrial settings and must be installed and operated by authorized qualified personnel.

Q: Who is responsible for ensuring the functionality of the entire machine or plant?

A: It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant, including the proper integration and use of safety switchgear.

Q: Where can I find further technical information about the product?

A: Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet at products.schmersal.com.

Safety switch with separate actuator AZ 17-11ZK-ST-2493

1 About this document

Function
This document provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the switchgear. The operating instructions enclosed with the device must always be kept in a legible condition and accessible.

Target group of the operating instructions: authorised qualified personnel
All operations described in the operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only.

  • Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation.

  • The machine builder must carefully select the harmonised standards to be complied with as well as other technical
    specifications for the selection, mounting and integration of the components.

  • The information contained in this operating instructions manual is provided without liability and is subject to technical modifications.

Explanation of the symbols used

Information, hint, note: This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could lead to failures or malfunctions.
Warning:Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.

Appropriate use

The Schmersal range of products is not intended for private consumers.
The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter “Product description”.

General safety instructions
The user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.

Product Description

Ordering code

AZ 17-(1)Z(2)K-(3)-(4)-(5)

(1) 11 02
(2) R
(3) 2243 2243-1 ST
(4) 1637
(5) 5M 6M
  • 1 NO /1 NC
  • 2 NC
  • 5N 30N
  • M16 M12 4
  • 5m 6m

Special versions
For special versions, which are not listed in the ordering code, these specifications apply accordingly, provided that they correspond to the standard version.

Purpose

  • The safety switches with separate actuator are suitable for sliding, hinged and removable safety guards, which need to be closed in order to ensure the necessary operational safety.
  • The safety switches are used for applications, in which the hazardous situation is terminated without delay when the safety guard is opened.
  • When the safety guard is opened, the NC contacts are positively opened and the NO contacts are closed.

The safety switchgears are classified according to EN ISO 14119 as type 2 interlocking devices.

The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level.

The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards.

Warning about misuse

In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.

Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with the operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden, the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device.

Note about the safety classification

Basically suitable up to Cat. 1 / PL c.
With 2-channel usage with fault exclusion mechanism (if a fault exclusion to the 1-channel mechanics is authorised) and suitable logic applicable up to Cat. 3 / PL d

(Determined values can vary depending on the application-specific parameters as well as the load.)
If multiple safety components are wired in series, the Performance Level to EN ISO 13849-1 will be reduced due to the restricted error detection under certain circumstances.

Mounting

General mounting instructions

Please observe the remarks of the standards EN ISO 12100, EN ISO 14119 and EN ISO 14120.

The mounting position however must be chosen so that the ingress of dirt and soiling in the used opening is avoided. Use the supplied base plate for the fixing. The tightening torque of the fixing screws must not exceed 150 Ncm. The enclosure must not be used as an end stop. Any position is possible. The mounting position however must be chosen so that the ingress of dirt and soiling in the used opening is avoided. The unused opening must be sealed by means of slot sealing plugs.

Dimensions
All measurements in mm.

SCHMERSAL-17-11ZK-ST-2493-Safety-Switch-Separate-Actuator-
FIG-3

Mounting of the actuator
See operating instructions Actuator.

The actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling of the screw heads).

Electrical connection

General information for electrical connection

The electrical connection may only be carried out by authorised personnel in a de-energised condition.

IDC method of termination
The IDC method of termination (cut clamp technology) enables connecting flexible wires with cable section 0.75 … 1 mm² without using conductor ferrules. To this effect, strip the wire for 17 … 20 mm and insert it into the cable gland, close the cable gland, push the conductors in the groove of the cover (refer to wiring example) and screw the cover back. Alternatingly tighten the cover screws uniformly. Tightening force for the Torx T10 cover screws 0.7 … 1 Nm.

SCHMERSAL-17-11ZK-ST-2493-Safety-Switch-Separate-Actuator-
FIG-4

Contact Options

Contacts are shown with safety guard closed. All NC contacts have positive break .

SCHMERSAL-17-11ZK-ST-2493-Safety-Switch-Separate-Actuator-
FIG-6

Set-up and maintenance

The safety function of the safety components must be tested. In the case of correct installation and adequate use, the safety switchgear features maintenance-free functionality. A regular visual inspection and functional test, including the following steps, is recommended:

  1. Check for correct installation of the actuator and the switch
  2. Check the integrity of the cable entry and connections
  3. Check the switch enclosure for damages
  4. Remove particles of dust and soiling
    • Adequate measures must be taken to ensure protection against tampering either to prevent tampering of the safety guard, for instance by means of replacement actuators.
    • Damaged or defective components must be replaced.

Disassembly and disposal

Disassembly

The safety switchgear must be disassembled in a de-energised condition only.

Disposal

The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.