SPXFLOW Aqua Void Electro Magnetic Combo Bilge Pump Instruction Manual

June 16, 2024
SPXFLOW

SPXFLOW Aqua Void Electro Magnetic Combo Bilge Pump

Specifications

  • Product Name: Aqua Void Cartridge Bilge Pump
  • Features:
    • High Flow Impeller Design
    • Quick-Change Motor Connection
  • Benefits:
    • Heightened Efficiency and an Increased Flow Rate
    • Most Efficient and Highest Flow in GPH Capacity Category
    • Enjoy Quick and Hassle-Free Cartridge Motor Changes or Capacity Upgrades
    • Industry First and Only Cartridge Motor Pump with included harness connection requiring no cutting and splicing of wires
    • Durable Thermoplastic Housing Design Commonality with Removable Motor Cartridge
    • Water-Cooled Motor, 316 Stainless Steel Shaft and Permanently Lubricated Double Bearings
    • Check Valve
    • Straight or 90-Degree Dura Port Discharge Ports
    • Common Body Allows Interchangeable Motor Cartridge Replacement to the Same or Different Size
    • Upgradeable Cartridge Motors
    • Corrosion Resistant and Extended Life
    • Reduces Cycling from Water Back Flow
    • Allow Multi-Directional Hose Routing and Eliminate Stress Cracking without Disengaging Hoses or Removing Pump
    • Molded T-Slot
    • Easy Installation with Switches
    • Clip-In Basket
    • Ease of Installation & Maintenance
  • Available Sizes:
    • 500 GPH 12V
    • 800 GPH 12V
  • Technical Specifications:

PART NUMBER| PUMP SIZE| DESCRIPTION| CAPACITY STRAIGHT (12V) GPH| CAPACITY STRAIGHT (12V) L/MIN| VOLTAGE| AMP| FUSE SIZE| HOSE CONN.
---|---|---|---|---|---|---|---|---
10-13626-01| Aqua Void| | | | | | |
10-13635-01| 500 GPH Aqua Void Automatic – Ultima Combo| 600| 38| 12V| 2.7A| 3.5 A| 3/4″
10-13637-01| Aqua Void Automatic- Electro-Magnetic Combo| 12V| 3.7A| 5 A| 3/4″
10-13626-05| Aqua Void| | | | | | |
10-13636-01| 800 GPH Aqua Void Automatic – Ultima Combo| 785| 50| 12V| 3.7A| 5 A| 3/4″
10-13637-02| Aqua Void Automatic- Electro-Magnetic Combo| 12V| 3.7A| 5 A| 3/4″

Pump Dimensions

PUMP SIZE DESCRIPTION WIDTH (A) HEIGHT (B) LENGTH (C) WEIGHT
500 GPH Aqua Void 2.75″ (70mm) 4.69″ (119mm) 5.24″ (133mm) 11.2oz

(0.32kg)
800 GPH| Aqua Void| 2.75″ (70mm)| 4.69″ (119mm)| 6.63″ (168mm)| 12.6oz (0.36kg)
500 GPH| Aqua Void Automatic – Ultima Combo| 2.95″ (75mm)| 4.69″ (120mm)| 5.24″ (133mm)| 17.1oz (0.48kg)
800 GPH| Aqua Void Automatic – Ultima Combo| 2.95″ (75mm)| 4.69″ (120mm)| 6.63″ (168mm)| 18.5oz (0.52kg)
500 GPH| Aqua Void Automatic – Electro-Magnetic Combo| 3.88″ (99mm)| 4.69″ (119mm)| 6.17″ (157mm)| 15.9oz (0.45kg)
800 GPH| Aqua Void Automatic – Electro-Magnetic Combo| 3.88″ (99mm)| 4.69″ (119mm)| 6.17″ (157mm)| 17.3oz (0.49kg)

Standard Features: All Cartridge Pumps

  • BODY: ABS
  • DURA PORT: PA66/GF – Nylon
  • SHAFT: 316 Stainless Steel
  • SHAFT SEAL: Nitrile Rubber
  • MOTOR CARTRIDGE: PC-ABS
  • WIRE SIZE: 16 GA, TINNED

Aqua Void Cartridge Bilge Pump Usage Instructions

Installation

  1. Choose a suitable location for the pump.
  2. Ensure the bilge area is clean and free from debris.
  3. Attach the pump to the desired surface using the provided brackets or screws.
  4. Connect the hose to the discharge port of the pump.
  5. Rout the hose to the desired outlet location, ensuring proper drainage.
  6. If necessary, use the included T-slot for additional hose routing options.
  7. Connect the pump to a suitable power source using the appropriate voltage and fuse size.
  8. Secure all electrical connections and ensure proper grounding.

Operation

  1. Ensure the pump is securely installed and connected to a power source.
  2. Turn on the power supply to activate the pump.
  3. The pump will start drawing water from the bilge area and discharge it through the hose.
  4. Monitor the pump operation and check for any signs of malfunction or blockage.
  5. If necessary, clean or replace the pump cartridge motor for optimal performance.

Maintenance

  1. Regularly inspect the pump for any signs of damage or wear.
  2. Clean the pump and remove any debris or obstructions that may affect its performance.
  3. Check the electrical connections and wiring for any loose or damaged components.
  4. Replace any worn-out parts or components as needed.
  5. Perform routine testing to ensure the pump is functioning correctly.

**FAQ

**

Q: Can I use this pump in salt

AQUA VOID CARTRIDGE BILGE PUMP

FEATURES BENEFITS COMPETITIVE ADVANTAGES

High Flow Impeller Design

| Heightened Efficiency and an Increased Flow Rate| Most Efficient and Highest Flow in G PH Capacity Category
Quick-Change Motor Connection| Enjoy Quick and Hassle-Free Cartridge Motor Changes or Capacity Upgrades| ****

Industry First and Only Cartridge Motor Pump with included harness connection requiring no cutting and splicing of wires

Durable Thermoplastic Housing

Design Commonality with Removable Motor Cartridge

| Common B ody Allows Interchangeable Motor Cartridge Replacement to the

S ame or Different Size

| **** Upgradeable Cartridge Motors
Water-Cooled Motor, 316 St ainless Steel Shaft and Permanently

Lubricated Double Bearings

| Corrosion Resist ant and Extended Life|
Check Valve| Reduces Cycling from Water B ack Flow
** Straight or 9 0-Degree Dura Port Discharge Ports| Allow Multi- Directional Hose Routing and Eliminate Stress Cracking without Disengaging Hoses or Removing Pump
Molded T-Slot| Easy Inst allation with Switches
Clip-In B asket| Ease of Inst allation & Maintenance
AVAILABLE SIZES**

  • 500 GPH 12V
  • 800 GPH 12V

|

TECHNICAL SPECIFICATIONS

Aqua Void Cartridge Bilge Pump: Non-Automatic Submersible Bilge Pumps

PART

NUMBER

| PUMP SIZE| D E SCR I PTI ON| CAPACITY

STRAI G HT ( 12 V)

| VOLTAG E| AM P| FU S E SIZE| H OS E CON N.
---|---|---|---|---|---|---|---
G PH| L/ MIN
10-13626-01|

500

GPH

| Aqua Void| 600|

38

|

12V

|

2.7A

|

3.5 A

| 3/4″
10-13635-01| Aqua Void Automatic – Ultima Combo
10-13637-01| Aqua Void Automatic- Electro-Magnetic Combo
10-13626-05|

800

GPH

| Aqua Void| 785| 50|

12V

|

3.7A

|

5 A

|

3/4″

10-13636-01| Aqua Void Automatic – Ultima Combo
10-13637-02| Aqua Void Automatic- Electro-Magnetic Combo

Pump Dimensions

PUMP SIZE| D E SCR I PTI ON| WI DTH (A)| HEI GHT (B)| LE N GTH (C)| WE I G HT
---|---|---|---|---|---
500 GPH| Aqua Void|

2.75″

(70mm)

| ****

4.69″ (119mm)

| ****

5.24″ (133mm)

| 11.2oz (0,32kg)
800 GPH| 12.6oz (0,36kg)
500 GPH| Aqua Void Automatic – Ultima Combo| 2.95″

(75mm)

| 4.69″ (120mm)| 6.63″ (168mm)| 17.1oz (0,48kg)
800 GPH| 18.5oz (0,52kg)
500 GPH| Aqua Void Automatic – Electro-Magnetic Combo| 3.88″

(99mm)

| 4.69″ (120mm)| **** 6.17″ (157mm)| 15.9oz (0,45kg)
800 GPH| 17.3oz (0,49kg)

Dimensions include straight fitting installed.
Standard Features : All Cartridge Pumps

B ODY ABS D U RA P ORT PA66/GF – Nylon
S HAFT 316 Stainless Steel S HAFT S EAL Nitrile Rubber
M OTOR CARTR I D G E PC-ABS WIRE SIZE 16 GA, TINNED

Cartridge Motor: Replacement Cartridge

PART

NUMBER

| PUMP SIZE| D E SCR I PTI ON
---|---|---
09-36336-01| 500

GPH

| Aqua Series Replacement Cartridge Motor
09-36336-06| 800

GPH

| Aqua Series Replacement Cartridge Motor

SPX FLOW, Inc. reserves the right to incorporate our latest design and material changes without notice or obligation. Design features, materials of construction and dimensional data, as described in this bulletin, are provided for your information only and should not be relied upon unless confirmed in writing. Please contact your local sales representative for product availability in your region. The green “ ” is a trademark of SPX FLOW, Inc.
For more information, visit www.spxflow.com/johnson-pump- marine

©2023 SPX FLOW, Inc. JP_AV_FLR_US
Version: 09/2023

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals