Specifications

Part Number| Pump Size| Description| Capacity (Straight, 12V)| Voltage| Amp| Fuse Size| Hose Conn.| Weight
---|---|---|---|---|---|---|---|---
10-13642-01| Aqua O2 Cartridge Aerator Pump| 500 GPH| 585 L/min| 12V| 2.7A| 3/4″| 9.6 oz.
10-13649-01| Aqua O2 Cartridge Twin Port Aerator Pump| 800 GPH| 810 L/min| 12V| 3.7A| 3/4″| 10.4 oz.

Features

  • High Flow Impeller Design: Heightened efficiency and increased flow rate.
  • Quick-Change Motor Connection: Enjoy quick and hassle-free cartridge motor changes or capacity upgrades. Industry first and only cartridge motor pump with included harness connection requiring no cutting and splicing of wires.
  • Reorient Discharge in Any Direction: Unmatched versatility for ease of installation.
  • Durable Thermoplastic Housing Design Commonality with Removable Motor Cartridge: Common body allows interchangeable motor cartridge replacement to the same or different size.
  • Water-Cooled Motor, 316 Stainless Steel Shaft, and Permanently Lubricated Double Bearings: Corrosion resistant and extended life.
  • Dual Port Inlet: Allows single transom intake for dual intake pump application. Choose the correct intake for the application.

Benefits

  • Heightened efficiency and increased flow rate.
  • Quick and hassle-free cartridge motor changes or capacity upgrades.
  • Unmatched versatility for ease of installation.
  • Interchangeable motor cartridge replacement to the same or different size.
  • Corrosion resistant and extended life.
  • Allows single transom intake for dual intake pump application.

Competitive Advantages

  • Most efficient and highest flow in GPH capacity category.
  • Industry first and only cartridge motor pump with included harness connection requiring no cutting and splicing of wires.

Product Usage Instructions

Installation

  1. Select the appropriate Aqua O2 Aerator or Live well Pump based on your desired capacity (500 GPH or 800 GPH) and voltage (12V).
  2. Prepare the installation location by ensuring it is clean and free from debris.
  3. Position the pump in the desired location, ensuring proper orientation for the discharge.
  4. Connect the hose to the pump’s hose connection.
  5. Securely fasten the pump using screws or other appropriate mounting hardware.
  6. Connect the pump to a power source with the correct voltage and fuse size.
  7. Test the pump to ensure proper operation.

Motor Cartridge Replacement

  1. Ensure the power source is disconnected before proceeding with motor cartridge replacement.
  2. Remove any screws or fasteners securing the motor cartridge to the pump body.
  3. Disconnect the wire harness from the motor cartridge.
  4. Remove the old motor cartridge from the pump body.
  5. Insert the new motor cartridge into the pump body, ensuring a secure fit.
  6. Reconnect the wire harness to the new motor cartridge.
  7. Securely fasten the new motor cartridge to the pump body using screws or fasteners.
  8. Reconnect the power source and test the pump to ensure proper operation.

FAQ

  • Q: Can I increase or decrease the capacity of the Aqua O2 Aerator or Livewell Pump?
    A: Yes, you can increase or decrease the capacity of the pump according to your environment and flow needs. This allows for customization based on specific requirements.

  • Q: What is the purpose of the dual port inlet?
    A: The dual port inlet allows for a single transom intake for a dual intake pump application. This provides flexibility and convenience in installations where multiple pumps are needed.

  • Q: Are the Aqua O2 Aerator and Live well Pumps corrosion resistant?
    A: Yes, the pumps are designed with a durable thermoplastic housing and corrosion-resistant materials, such as 316 stainless steel shafts, to ensure extended life and performance even in harsh marine environments.

AQUA O2 AERATORS & LIVEWELL PUMPS

FEATURES BENEFITS COMPETITIVE ADVANTAGES

High Flow Impeller Design

| Heightened efficiency and an increased flow rate| Most efficient and highest flow in GPH capacity category
Quick-Change Motor Connection| Enjoy quick and hassle-free cartridge motor changes or capacity upgrades| Industry first and only cartridge motor pump with included harness connection requiring no cutting and splicing of wires
360° Pump Discharge Rotation| Reorient discharge in any direction| Unmatched versatility for ease of installation
Durable Thermoplastic Housing Design Commonality with Removable Motor Cartridge| Common body allows interchangeable motor cartridge replacement to the same or different size|
Water-Cooled Motor, 316 Stainless Steel Shaft and Permanently Lubricated Double Bearings| Corrosion resistant and extended life
Upgradeable Motor Cartridge| Can increase or decrease capacity according to environment and flow needed
Dual Port Inlet| Allows single transom intake for dual intake pump application
Straight or 90-Degree Inlet| ** Chose correct intake for the application
AVAILABLE SIZES**

  • 500 GPH 12V
  • 800 GPH 12V

| Aqua O 2

TECHNICAL SPECIFICATIONS

Cartridge Aerator Pump & Cartridge Twin Port Aerator Pump

**PART**

NUMBER

| **PUMP SIZE| ****DESCRIPTION| CAPACITY
STRAIG HT ( 12 V)| ****VOLTAG E| ****AM P| ****FUS E SIZE| ****H OS E CON N.| ****WEIGHT
---|---|---|---|---|---|---|---|---
G PH| L/ MIN
10-13642-01| **
500

GPH

| Aqua O2 Cartridge Aerator Pump| 585| 37| 12V| 2.7A| 3.5 A| 3/4″| 9.6 oz.
10-13649-01| Aqua O2 Cartridge Twin Port Aerator Pump
10-13643-01|
800

GPH

| Aqua O2 Cartridge Aerator Pump| 810| 51| 12V| 3.7A| 5 A| 3/4″| **** 10.4 oz.
10-13650-01| Aqua O2 Cartridge Twin Port Aerator Pump

All Aqua O2 Cartridge Aerator Pumps offer the convenience of using only one intake for both the livewell and wash down pump. Aqua O2 Cartridge Aerator Pump includes 3/4 NPSM thru-hull inlet that can be used as straight or 90°.
Aqua O2 Cartridge Twin Port Aerator Pump only includes 3/4 NPT seacock inlet.
Standard Features: All Cartridge Aerator Pumps

BODY ABS D U RA PORT PA66/GF – Nylon
S HAFT 316 Stainless Steel S HAFT S EAL Nitrile Rubber
M OTOR CARTR I D G E PC-ABS WIRE SIZE 16 GA, TINNED

Cartridge Motor : Replacement Cartridge

PART

NUMBER

| PUMP SIZE| D E SCR I PTION
---|---|---
09-36336-01| 500 GPH| Aqua Series Replacement Cartridge Motor
09-36336-06| 800 GPH| Aqua Series Replacement Cartridge Motor

360° Rotation – Reorient Discharge in Any Direction

SPX FLOW, Inc. reserves the right to incorporate our latest design and material changes without notice or obligation. Design features, materials of construction and dimensional data, as described in this bulletin, are provided for your information only and should not be relied upon unless confirmed in writing. Please contact your local sales representative for product availability in your region. The green “ ” is a trademark of SPX FLOW, Inc.
For more information, visit www.spxflow.com/johnson-pump- marine
©2023 SPX FLOW, Inc. JP_O2_FLR_US
Version : 09/2023

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals