LEVOIT LUH-D302-MUS Dual 150 Ultrasonic Cool Mist Humidifier User Manual
- June 16, 2024
- Levoit
Table of Contents
LEVOIT LUH-D302-MUS Dual 150 Ultrasonic Cool Mist Humidifier
SAFETY INFORMATION
To reduce the risk of fire, electric shock, or other injury, follow all instructions and safety guidelines.
General Safety
- Only use the humidifier as described in this manual.
- Place the humidifier and cord so that it will not be knocked over. Do not place near large pieces of furniture or in high-traffic areas.
- When not in use, turn the humidifier off and disconnect from power by removing the plug from the outlet.
- Do not use the humidifier in wet environments.
- Keep the humidifier out of reach from children.
- Do not open the base or remove the water level sensor for self servicing.
- Always unplug your humidifier from the power outlet before cleaning your humidifier or detaching the water tank from the humidifier base.
- Always make sure to place the humidifier on a flat, level surface before operation.
- Only fill the water tank with clean water. Never fill the water tank with any other liquids.
- Do not place the humidifier near sources of heat, such as stovetops, ovens, or radiators.
- Do not place the humidifier directly on floors, carpets, or rugs.
- Do not use other items as replacement parts for this product.
- Do not cover the nozzle while the humidifier is on. Doing so may damage the humidifier.
- Remove the water tank from the base before moving the humidifier.
- Do not immerse the humidifier base, power cord, or plug in water. If the humidifier is damaged or is not functioning properly, stop using it and contact Customer Support immediately .
- This humidifier is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Supervise children when they are near the humidifier.
- Children should not clean or perform maintenance on the humidifier without supervision.
- Children should be supervised to ensure that they do not play with the humidifier.
- Household use only. Not for commercial use.
Caution: Risk of Leaks and Electric Shock
Do not add supplemental water treatment liquids into the water tank or base
chamber.
This will damage the humidifier and cause leaks.
Power & Cord
- Ensure that the plug fits properly into a polarized socket.
- Do not handle the power cord or plug with wet hands. Keep the plug and power cord away from liquids.
- Your humidifier has a polarized plug (one prong is wider than the other), which fits into a polarized outlet only one way. This is a safety feature to reduce the risk of electric shock. If the plug does not fit, reverse the plug. If it still does not fit, do not use the plug in that outlet. Do not bypass this safety feature.
- If the power supply cord is damaged, it must be replaced by Arovast Corporation or similarly qualified persons in order to avoid an electric or fire hazard. Please contact Customer Support .
Package Contents
- 1 × Ultrasonic Cool Mist Humidifier
- 1 × Water Filter Sponge (1 Pre-Installed)
- 1 × Cleaning Brush
- 1 × User Manual
Specifications
Power Supply | AC 120V, 60Hz |
---|---|
Rated Power | 25W |
Water Tank Capacity | 0.79 gal / 3 L |
Max Runtime | Up to 25 hours on minimum mist setting |
Note: The humidifier may run for a longer or shorter time depending on
the environmental temperature and humidity.
Noise Level| < 28dB
Effective Range| 107–290 ft² / 10–27 m²
Dimensions| 7.2 × 8.1 × 11.6 in /
18.3 × 20.6 × 29.4 cm
Weight| 3 lb / 1.38 kg
GETTING TO KNOW YOUR HUMIDIFIER
- A. Nozzle
- B. Water Tank Cover
- C. Water Filter Housing
- D. Water Filter
- E. Mist Tube
- F. Water Tank
- G. Float
- H. Night Light Button
- I. Refill Indicator Light
- J. Control Knob
- K. Base
- L. Cleaning Brush
- M. Power Cord
- N. Max Water Line (Tank)
- O. Water Outlet Valve
- P. Noise Silencer
- Q. Air Outlet
- R. Max Water Line (Base)
- S. Float Brackets
- T. Transducer
- U. Secondary Float
- V. Feet
- W. Air Inlet
CONTROLS
Control Knob
- Rotate clockwise to turn on the humidifier and to adjust the mist level.
- Rotate counterclockwise to turn off the humidifier.
Note : There is a clicking sound when the humidifier turns on/off.
Refill Indicator Light
- The red light turns on when the water tank is empty. Refill the water tank.
- The red light turns off when the water tank is filled.
Night Light Button
- Press to turn the night light on.
- Press again to turn the night light off.
GETTING STARTED
-
Remove all packaging.
-
Take the water tank off of the base and remove all tape. [Figure 1.1]
-
Rinse and reassemble all parts before first use.
Note:- Check to make sure that the water filter is correctly in place. If not, then rotate the filter clockwise to secure it in place. [Figure 1.2]
- Check to make sure that the float is securely in place. [Figure 1.3]
-
Choose a hard, flat location for the humidifier at least 12 inches / 30 cm away from any walls. The surface must be water-resistant. [Figure 1.4]
-
Mist should be directed away from walls, furniture, bedding, and appliances. [Figure 1.5]
Filling & Refilling
Note : Make sure the water tank is clean before filling.
-
Turn the humidifier off.
-
Remove the water tank cover by holding the nozzle and pulling upward. [Figure 1.6]
-
Fill the tank with room-temperature water. [Figure 1.7]
Note-
We recommend using purified or distilled water to fill the tank.
-
Do not fill past the tank’s max water line.
-
Do not fill with hot water.
CAUTION -
Do not add water directly into the base chamber. [Figure 1.8]
-
Do not add water through the mist tube. [Figure 1.9]
-
-
Replace the water tank cover.
Note : Make sure the nozzle on the water tank cover is placed over the mist tube, or the humidifier may not work correctly. [Figure 1.10] -
Optionally, add 10–15 drops of essential oil into the base chamber for aromatherapy. [Figure 1.11]
Note : For best results, we recommend using Water soluble essential oil.
USING YOUR HUMIDIFIER
- Plug in the humidifier. Rotate the Control Knob clockwise to turn the humidifier on. Adjust the knob to your desired mist level. [Figure 2.1]
- Rotate the nozzle to adjust the direction of the mist. [Figure 2.2]
- When your room has reached your preferred humidity level, turn the humidifier to a lower setting, or turn it off.
- Rotate the Control Knob counterclockwise to turn the humidifier off.
- Press the Night Light Button to turn the night light on/off.
Note : If there is no water in the tank or the tank is removed, the humidifier will stop misting and the Refill Indicator light will turn on. Refill the tank and properly place it on the base to use your humidifier.
Important Tips
Your humidifier must have the correct level of water in the base chamber to work properly. If there is too much water in the base chamber, the humidifier cannot create mist.
- Never pour water directly into the base chamber. [Figure 2.3]
- Only add water to the water tank. The humidifier will automatically release the correct amount of water into the base chamber.
- Avoid moving or shaking the humidifier. [Figure 2.4] This may cause the water tank to release too much water into the base chamber.
- Before moving the humidifier, turn it off, unplug it, and remove the water tank.
- If your humidifier doesn’t produce mist correctly, check the max water line to see if there is too much water in the base chamber. Pour out extra water if water is over the max line. [Figure 2.5] Note : The max water line is only for this purpose.
Do not pour water into the base chamber.
CARE & MAINTENANCE
Note:
- All maintenance should be done on a water resistant surface, such as a kitchen counter.
- Change the water daily to avoid bacteria growth.
- Use a tissue or cloth to clean the nozzle regularly.
- If not using the humidifier for 3 days or longer, do not leave water inside. Clean and dry the humidifier instead.
Cleaning
You should clean your humidifier every 3 days, and when you’re ready to store it.
Note:
- Never immerse the base in water or liquid.
- Do not use detergents to clean the humidifier.
- Avoiding water or liquid going into the air outlet when cleaning the base chamber.
-
Unplug the humidifier.
-
Remove and rinse the water tank cover. [Figure 3.1]
-
Remove the water tank from the base and pour out any water from the tank and base chamber. [Figure 3.2] Note : When pouring out water, hold down the float to ensure that it does not fall out of the base chamber.
-
Remove the water filter assembly from the tank by rotating it counterclockwise and lifting it out. [Figure 3.3]
-
Rinse the tank, water filter assembly, and base chamber with room temperature water. [Figure 3.4]
Descaling Your Humidifier
- Remove the water filter from the tank by rotating it counterclockwise and lifting it out. [Figure 3.5]
- Fill the tank with 3 US cups / 710 mL of distilled white vinegar. [Figure 3.6]
- Replace the tank cover and swish the vinegar around the tank. [Figure 3.7]
- Place the tank on the base and soak for 15–20 minutes. Vinegar will drain into the base chamber and loosen scale (mineral buildup) in the tank and in the base chamber (including the transducer and float). [Figure 3.8]
- Remove the tank, remove the tank cover, and pour out any vinegar. [Figure 3.9]
- Flip the tank over and remove the noise silencer. To remove the noise silencer, press the release tabs and gently pull away from the humidifier. [Figure 3.10]
- Remove the float from the base chamber by pulling up one end of the float [Figure 3.11] and pulling the shaft out from the float brackets. One side of the float brackets is open (U-shaped) to allow the shaft to be removed. [Figure 3.12]
- Place the float, water filter assembly, and noise silencer in a small container. Fill with enough vinegar to cover them. Soak for 15–20 minutes. [Figure 3.13]
- Use the cleaning brush and a soft cloth to remove scale from all parts.
- Rinse all parts until any vinegar smell is completely gone. [Figure 3.14]
- Dry all parts with a cloth. Make sure all parts are completely dry before reassembling or storing.
Reassembling
-
Flip the water tank over and place the noise silencer back into the tank. [Figure 3.15]
-
Place the water filter assembly back into the tank and rotate it clockwise to secure it in place. [Figure 3.16]
-
Place the float back into the base chamber:
a. Make sure the correct side of the float is facing up. [Figure 3.17] b. Insert the smaller prong into the closed side of the float brackets. [Figure 3.18] c. Place the larger prong into the open (U-shaped) side of the float brackets. -
Place the tank back on the base. Refill the tank, if necessary.
-
Place the tank properly on the base and place the tank cover on the water tank.
Storing
Follow the cleaning instructions and allow all parts to dry completely before storing. Store in a cool, dry location.
The Filter Assembly
If the filter assembly is damaged or water cannot flow into the base chamber,
for further assistance, contact Customer Support.
The water filter can prevent the big particles in water from entering the base
and polluting the mist.
Meanwhile, it can filter out the big particles so they won’t get stuck in the
valve causing leakage. We suggest you change the filter regularly.
Problem | Possible Solution |
---|---|
Little or no mist comes out. | Turn the mist level to a higher setting. |
Fill the water tank.
There may be too much water in the base chamber. Empty the base chamber.
Refill the water tank (not the base chamber) and place the water tank properly
onto the base.
Make sure the air inlet on the bottom of the base is not blocked. The
humidifier should not be set on carpet or other surfaces that may block the
air inlet.
Make sure the nozzle is not blocked or clogged.
Make sure the humidifier is on a level surface.
The water temperature may be too low. Turn the mist level to the highest
setting and let the humidifier run for a while, then adjust to the desired
setting.
If the water tank or base was washed with detergent, rinse thoroughly with
clean water to remove any detergent.
Clean the water filter assembly (see page 6) or replace the filter with a new
one (see page 10).
Humidifier doesn’t turn on, or turns off unexpectedly.| Plug in the humidifier
and turn it on.
Add purified or distilled water to the water tank.
Humidifier produces an unusual smell.| If the humidifier is new, unplug and
rinse all parts, then place in a cool, dry place for 12 hours.
Clean the water tank and base chamber (see Care & Maintenance, ).
Humidifier makes a loud or unusual noise.| Make sure the water tank is
properly in place (see Getting Started , ).
Set mist level to a lower setting.
Empty the base chamber. Refill the water tank (not the base chamber) and place
the water tank properly onto the base.
The humidifier may be malfunctioning. Stop using the humidifier and contact
Customer Support.
White scale (mineral buildup) appears around the humidifier.| We recommend
using purified or distilled water to fill the humidifier. Avoid using water
with high mineral content.
Clean the humidifier .
Water leaks from the humidifier.| Make sure the silicone sealing ring around
the water outlet valve is secure.
Avoid running the humidifier in a room with high relative humidity.
Wipe any excess water off the top and bottom of the base.
Do not shake the humidifier.
Make sure to place the humidifier on a flat, level surface.
Check the water tank for leaks. If there are leaks, contact .
Condensation forms around humidifier or windows.| Humidity may be too high.
Turn down the mist level, turn off the humidifier, or open a door or window in
the room.
Mold grows inside the humidifier.| Clean the water tank and base chamber
regularly .
Refill Indicator Light turns on.| Fill the water tank.
Place the water tank properly on the base.
Clean the water filter or replace it with a new one. To request a new water
filter, contact.
FEDERAL COMMUNICATION
COMMISSION INTERFERENCE STATEMENT – PART 18
This device complies with part 18 of the FCC Rules.
This equipment generates and uses ISM frequency energy and if not installed
and used properly, that is in strict accordance with the manufacturer’s
instructions, may cause interference to radio and television reception. It has
been type tested and found to comply with limits for an ISM Equipment pursuant
to part 18 of FCC Rules, which are designed to provide reasonable protection
against such interference in a residential installation. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause interference to radio or television reception, which
can be determined by tuning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following:
- Reorient the receiving antenna of radio or television.
- Relocate the equipment with respect to the receiver.
- Move the equipment away from the receiver.
- Plug the equipment into a different outlet so that the equipment and receiver are on different branch circuits.
Conduct only the user maintenance found in this manual. Other maintenance and servicing can cause harmful interference and can void the required FCC compliance. The manufacturer is not responsible for any radio or TV interference cause by unauthorized modification to the equipment. It is the responsibility of the user to correct such interference.
FCC SDOC SUPPLIER’S DECLARATION OF CONFORMITY
Arovast Corporation hereby declares that this equipment is in compliance with the FCC Part 18 Subpart B. The declaration of conformity may be consulted in the support section of our Website, accessible from www.levoit.com
WARRANTY INFORMATION
Product | Levoit Dual 150 Ultrasonic Cool Mist Humidifier |
---|---|
Model | LUH-D302-MUS |
For your own reference, we strongly recommend that you record your order ID
and date of purchase.
Date of Purchase|
Order ID|
Terms & Policy
Arovast Corporation (“Arovast”) warrants this product to the original
purchaser to be free from defects in material and workmanship, under normal
use and conditions, for a period of 2 years from the date of original
purchase.
Arovast agrees, at our option during the warranty period, to repair any defect
in material or workmanship or furnish an equal product in exchange without
charge, subject to verification of the defect or malfunction and proof of the
date of purchase.
There is no other express warranty. This warranty does not apply:
- If the product has been modified from its original condition;
- If the product has not been used in accordance with directions and instructions in the user manual;
- To damages or defects caused by accident, abuse, misuse or improper or inadequate maintenance;
- To damages or defects caused by service or repair of the product performed by an unauthorized service provider or by anyone other than Arovast;
- To damages or defects occurring during commercial use, rental use, or any use for which the product is not intended;
- To damages or defects exceeding the cost of the product.
Arovast will not be liable for indirect, incidental, or consequential damages
in connection with the use of the product covered by this warranty.
This warranty extends only to the original consumer purchaser of the product
and is not transferable to any subsequent owner of the product regardless of
whether the product is transferred during the specified term of the warranty.
This warranty does not extend to products purchased from unauthorized sellers.
Arovast’s warranty extends only to products purchased from authorized sellers
that are subject to Arovast’s quality controls and have agreed to follow its
quality controls.
All implied warranties are limited to the period of this limited warranty.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.
If you discover that your product is defective within the specified warranty
period, please contact Customer Support via
support@levoit.com.
DO NOT dispose of your product before contacting us. Once our Customer Support
Team has approved your request, please return the product with a copy of the
invoice and order ID.
Every Levoit product automatically includes a 2-year limited warranty. To make
the customer support process quick and easy, register your product online at
www.levoit.com/warranty.
This warranty is made by : Arovast Corporation 1202 N. Miller St., Suite
A Anaheim, CA 92806, USA
CUSTOMER SUPPORT
If you have any questions or concerns about your new product, please contact
our helpful
Customer Support Team.
Arovast Corporation
1202 N. Miller St., Suite A
Anaheim, CA 92806, USA
Email : support@levoit.com
Toll-Free : 1-888-726-8520
Mon–Fri, 9:00 am–5:00 pm PST/PDT
Support Hours
*Please have your order invoice and order ID ready before contacting Customer Support.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>