- SELKIRK SK-U1 CT-001E Stainless Steel Chimney System
- Product Information
- Product Usage Instructions
- Wall Support Installations
- Typical Installation
- CEILING SUPPORT INSTALLATIONS / WALL SUPPORT INSTALLATIONS
- GENERAL SPECIFICATIONS
- Stainless Steel Chimney lengths
- CHIMNEY SECTIONS
- LOCKING BANDS
- Stainless Steel Elbows
- INSULATED ELBOW KITS INCLUDE:
- INSULATED ELBOWS
- INSULATED TEE
- KITS INCLUDE
- INSULATED TEE CAP
- Supports
- WALL SUPPORT
- Shields
- Flashings and Storm Collars
- Rain Cap
- Parts and Accessories
- Components Specific to Canada Only
- Customer Service and Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SELKIRK SK-U1 CT-001E Stainless Steel Chimney System
Product Information
Specifications:
- Chimney material : Stainless Steel
- Chimney sizes available : 6″, 7″, 8″
- Support weight capacity: Four times the combined weight of the chimney installation
- Temperature range : Continuous flue gas temperature
Product Usage Instructions
Ceiling Support Installations :
For one-story installations:
- Install the round top termination on top of the chimney section.
- Attach the storm collar and adjustable roof flashing to ensure a watertight seal.
- Install the chimney sections to reach the desired height.
- Attach the attic insulation shield for added safety.
- Connect the smoke pipe adapter to the ceiling support.
- Install the double wall stove pipe to complete the installation.
For two-story installations
- Follow steps 1-5 from the one-story installation instructions.
- Install the elbow for proper venting.
- Attach the round top termination and storm collar.
- Install the attic insulation shield and chimney sections.
- Attach the adjustable roof flashing and joist shield for additional support.
- Connect the ceiling support, smoke pipe adapter, and double wall stove pipe to complete the installation.
Wall Support Installations
For installations with square ceiling/cathedral support
- Follow the one-story ceiling support installation instructions.
- Install the wall band and insulated wall thimble for proper venting.
- Attach the insulated tee & cap and adjustable wall support.
- Complete the installation by connecting the double wall stove pipe and smoke pipe adapter.
For installations through a soffit
- Follow steps 1-3 from the one-story ceiling support installation instructions.
- Install the round top termination, chimney sections, and wall band.
- Attach the insulated wall thimble and insulated tee & cap.
- Connect the adjustable wall support and complete the installation with the double wall stove pipe and smoke pipe adapter.
FAQ
- Q: What type of appliances can the UltimateOne All-Fuel Chimney be used for?
- A : The UltimateOne All-Fuel Chimney can be used for all solid wood, gas, and oil-fired residential appliances including cooking ranges, heating stoves, fireplaces, central furnaces, floor furnaces, steam and hot water boilers, recessed heaters, unit heaters, water heaters, masonry fireplaces, and domestic type incinerators.
- Q: How should the chimney passing through occupied portions of the building be enclosed?
- A : The chimney passing through occupied portions of the building must be enclosed with a 2-inch air space clearance maintained. Such enclosures must be firestopped at every floor penetration with UltimateONE parts designed for this purpose.
- Q: What is the weight capacity of the UltimateONE’s supports?
- A : The supports of the UltimateONE chimney are capable of supporting four times the combined weight of the chimney installation, at the maximum height given for the specific support.
Typical Installation
CEILING SUPPORT INSTALLATIONS
CEILING SUPPORT INSTALLATIONS / WALL SUPPORT INSTALLATIONS
USE USP STOVE PIPE FOR OPTIMUM SYSTEM PERFORMANCE.
Note : Technical data, photographs, drawings and installations may vary and are for reference only. Actual installations must be conducted according to the data and drawings shown in the installation instructions.
GENERAL SPECIFICATIONS
UltimateONE factory-built chimney has been laboratory tested and listed by Intertek Testing Services at temperatures up to 2100ºF (1150ºC) with solid fuel, gas and oil-fired residential and building heating appliances in accordance with the following Safety Standards; CAN/ULC-S629 and CAN/ULC0604 in Canada and UL 103 Type HT in the USA.
TESTED TEMPERATURES / CANADA / USA
- Continuous flue gas temperature / 650ºC (1200ºF) / 1000ºF
- Over Firing (for a duration of 60 minutes) / 925ºC (1700ºF) / 1400ºF
- Creosote Burn Out Test
- (3 x 30 minutes – CANADA) / 1150ºC (2100ºF) / 2100ºF
- (3 x 10 minutes – USA)
UltimateONE chimney (6″, 7″ and 8″ inner diameter sizes) may be used for all solid wood, gas, and oil-fired residential appliances including cooking ranges, heating stoves, fireplaces, central furnaces, floor furnaces, steam and hot water boilers, recessed heaters, unit heaters and water heaters. UltimateONE may also be used for masonry fireplaces and domestic-type incinerators.
UltimateONE’s supports are capable of supporting four times the combined weight of the chimney installation, at the maximum height given for the specific support.
Chimneys passing through occupied portions of the building must be enclosed with a 2″ air space clearance maintained. Such enclosures must be firestopped at every floor penetration with UltimateONE parts designed for this purpose.
Framing and Support Table
- *The clearance to combustibles obtained with a correctly installed Ceiling Support Assembly in the framed opening specified has been tested. The 2″ clearance does not apply at this location.
- **For Cathedral Ceiling application a rectangular opening must be prepared to suit the pitch of the roof.
- ***The Wall Support (WSP) is designed for 16-inch on-center construction. First set of numbers represents when installed 2″ from the vertical wall and the second set of numbers represents when installed 6″ from the vertical wall.
UltimateONE Chimney Features & Benefits
Stainless Steel Chimney lengths
The chimney must extend at least three feet above the highest point where it passes through the roof surface and at least two feet higher than any part of the building within a horizontal distance of ten feet.
- Each length includes a Latch Locking Band.
- Sectional overlap of 1″.
- Chimneys are sized according to the inner diameter and are available in 6″, 7″ and 8″.
- Chimney sections are available in 48″, 36″, 24″, 18″, 12″, 9″ & 6″ lengths.
- Inner liner also available in 316 stainless steel 6″ diameter.
Product # | Part # | Size | A | B | C | Pack |
---|
0821606
0821606-316
| 6U1-6
6U1-6-316
| 6″ x 6″| 6″| 6″| 8″| 1
0821406
0821406-316
| 6U1-9
6U1-9-316
| 6″ x 9″| 9″| 6″| 8″| 1
0821206
0821206-316
| 6U1-12
6U1-12-316
| 6″ x 12″| 12″| 6″| 8″| 1
0821106
0821106-316
| 6U1-18
6U1-18-316
| 6″ x 18″| 18″| 6″| 8″| 1
0821006
0821006-316
| 6U1-24
6U1-24-316
| 6″ x 24″| 24″| 6″| 8″| 1
0820306
0820306-316
| 6U1-36
6U1-36-316
| 6″ x 36″| 36″| 6″| 8″| 1
0820406
0820406-316
| 6U1-48
6U1-48-316
| 6″ x 48″| 48″| 6″| 8″| 1
0821607| 7U1-6| 7″ x 6″| 6″| 7″| 9″| 1
0821407| 7U1-9| 7″ x 9″| 9″| 7″| 9″| 1
0821207| 7U1-12| 7″ x 12″| 12″| 7″| 9″| 1
0821107| 7U1-18| 7″ x 18″| 18″| 7″| 9″| 1
0821007| 7U1-24| 7″ x 24″| 24″| 7″| 9″| 1
0820307| 7U1-36| 7″ x 36″| 36″| 7″| 9″| 1
0820407| 7U1-48| 7″ x 48″| 48″| 7″| 9″| 1
0821608| 8U1-6| 8″ x 6″| 6″| 8″| 10″| 1
0821408| 8U1-9| 8″ x 9″| 9″| 8″| 10″| 1
0821208| 8U1-12| 8″ x 12″| 12″| 8″| 10″| 1
0821108| 8U1-18| 8″ x 18″| 18″| 8″| 10″| 1
0821008| 8U1-24| 8″ x 24″| 24″| 8″| 10″| 1
0820308| 8U1-36| 8″ x 36″| 36″| 8″| 10″| 1
0820408| 8U1-48| 8″ x 48″| 48″| 8″| 10″| 1
HEIGHT REQUIREMENTS
CHIMNEY SECTIONS
ADJUSTABLE CHIMNEY LENGTH
- Used to adjust the system to an exact overall length.
- Used also between elbows for a required offset distance.
- All Stainless Steel construction with telescoping design.
- Locking Band included.
- Inner liner also available in 316 stainless steel 6″ diameter.
Product # | Part # | Size | A | B | C | Pack |
---|
0821506
0821506-316
| 6U1-AL18
6U1-AL18-316
| 6″| 6″| 8″| 6.5″-17″| 1
0821507| 7U1-AL18| 7″| 7″| 9″| 6.5″-17″| 1
0821508| 8U1-AL18| 8″| 8″| 10″| 6.5″-17″| 1
LOCKING BANDS
- All Stainless Steel construction.
- Latch-type locking mechanism.
- Simply latches to positively lock into place (no tools required).
Product # | Part # | Size | A | Pack |
---|---|---|---|---|
0829306 | 6U1-LB | 6″ | 8.15″ | 10 |
0829307 | 7U1-LB | 7″ | 9.15″ | 10 |
0829308 | 8U1-LB | 8″ | 10.15″ | 10 |
Stainless Steel Elbows
6″ Diameter 7″ Diameter 8″ Diameter
Elbow Length A B A B A B
2 x 15° NONE 1-1/2″ 11-1/2″ 1-1/2″
11-3/4″ 1-5/8″| 12″
2 x 15° 6″ 3″ 16-7/8″ 3″
17-1/8″ 3″| 17-3/8″
2 x 15° 9″ 3-3/4″ 19-3/4″ 3-3/4″
20″ 3-3/4″| 20-1/4″
2 x 15° 12″ 4-1/2″ 22-5/8″ 4-1/2″
22-7/8″ 4-5/8″| 23-1/8″
2 x 15° 18″ 6″ 28-3/8″ 6-1/8″
28-5/8″ 6-1/8″| 28-7/8″
2 x 15° 24″ 7-5/8″ 34-1/4″ 7-5/8″
34-1/2″ 7-5/8″| 34-3/4″
2 x 15° 36″ 10-3/4″ 45-3/4″ 10-3/4″
46-1/8″ 10-3/4″| 46-3/8″
2 x 15° 48″ 13-7/8″ 57-3/8″ 13-7/8″
57-5/8″ 13-7/8″| 57-7/8″
2 x 30° NONE 3-3/8″ 12-1/2″ 3-1/2″
13″ 3-5/8″| 13-1/2″
2 x 30° 6″ 6-1/8″ 17-1/4″ 6-1/4″
17-1/8″ 6-3/8″| 18-1/4″
2 x 30° 9″ 7-5/8″ 19-7/8″ 7-3/4″
20″ 7-7/8″| 20-7/8″
2 x 30° 12″ 9-1/8″ 22-3/8″ 9-1/4″
22-7/8″ 9-3/8″| 22-3/8″
2 x 30° 18″ 12-1/8″ 27-5/8″ 12-1/4″
28-5/8″ 12-3/8″| 28-5/8″
2 x 30° 24″ 15-1/8″ 32-7/8″ 15-1/4″
34-1/2″ 15-3/8″| 33-7/8″
2 x 30° 36″ 21-1/8″ 46-1/4″ 21-1/4″
46-1/8″ 21-3/8″| 44-1/4″
2 x 30° 48″ 27-1/8″ 53-5/8″ 27-1/4″
57-5/8″ 27-3/8″| 54-5/8″
2 x 45° NONE 6″ 14-5/8″ 6-1/8″
14-7/8″ 6-2/8″| 15-2/8″
2 x 45° 6″ 9-7/8″ 18-1/2″ 10″
18-7/8″ 10-1/4″| 19-1/8″
2 x 45° 9″ 12″ 20-5/8″ 12-1/8″
21″ 12-3/8″| 21-1/4″
2 x 45° 12″ 14-1/8″ 22-3/4″ 14-1/4″
23-1/8″ 14-4/8″| 23-3/8″
2 x 45° 18″ 18-3/8″ 27″
18-1/2″ 27-3/8″ 18-5/8″| 27-5/8″
2 x 45° 24″ 22-5/8″ 31-1/4″ 22-3/4″
31-5/8″ 22-7/8″| 31-7/8″
2 x 45° 36″ 31-1/8″ 39-3/4″ 31-1/4″
40-1/8″ 31-3/8″| 40-3/8″
2 x 45° 48″ 39-5/8″ 48-1/4″ 39-3/4″
48-1/2″ 39-7/8″| 48-7/8″
All measurements in chart are in inches. Construction tolerances are ± one
inch.
NOTE : In Canada, 45° insulated elbow kit are permissible and available.
A pair of elbows can be used to provide a sloped offset of 15º and 30º. An
offset data table is supplied to determine the offset dimension and the
offset height.’
The vertical run of chimney above an offset must be supported using an
Interior Resupport Assembly (U1-UIRA) securely clamped to the pipe just above
a Locking Band (U1-LB), with its straps nailed to a nearby structure.
INSULATED ELBOW KITS INCLUDE:
- Elbows
- Locking Bands
- Interior Resupport Assembly
- Inner liner also available in 316 stainless steel 6″ diameter.
Product #| Part #| Size| A| B| Pack
---|---|---|---|---|---
15º ELBOW KIT
0822406
0822406-316
| 6U1-EL15K
6U1-EL15K-316
| 6″| 6″| 8″| 1
0822407| 7U1-EL15K| 7″| 7″| 9″| 1
0822408| 8U1-EL15K| 8″| 8″| 10″| 1
30º ELBOW KIT
0822306
0822306-316
| 6U1-EL30K
6U1-EL30K-316
| 6″| 6″| 8″| 1
0822307| 7U1-EL30K| 7″| 7″| 9″| 1
0822308| 8U1-EL30K| 8″| 8″| 10″| 1
*45º ELBOW KIT (Canada Only)*
0822506| 6U1-EL45K| 6″| 6″| 8″| 1
0822507| 7U1-EL45K| 7″| 7″| 9″| 1
0822508| 8U1-EL45K| 8″| 8″| 10″| 1
45° Elbow kit is for connection to liquid or gas fired appliances normally producing flue gases of 540°C (1000°F). May also be installed with specific CAN/ULC-S610. Factory-Built Fireplaces where specified in the fireplace manufacturer’s installation instructions.
NOTE : In Canada, 45° insulated elbow kit are permissible and available.
INSULATED ELBOWS
- Used when an offset is required.
- Maximum of 8′ is allowable between elbows.
- Fully insulated and can be used at the same 2″ clearance as chimney lengths.
- Must be supported with an Interior Resupport Assembly.
- Can be rotated to attain optimum positioning offset, and allow chimney to return to correct vertical alignment, prior to installing Locking Bands.
INSULATED TEE
KITS INCLUDE
-
INSULATED TEE,
-
INSULATED TEE CAP
-
LATCH LOCKING BAND
-
Used to seal the base of an Insulated Tee.
-
Used for a through-the-wall installation using a Wall Support.
-
A chimney length is attached to the tee branch using a Locking Band to pass safely through a wall.
-
Maximum height of chimney supported by the Insulated Tee fixed to a Wall Support is variable depending on the Wall Support type selected.
-
Inner liner also available in 316 stainless steel 6″ diameter.
Product # | Part # | Size | A | B | C | Pack |
---|
0824306
0824306-316
| 6U1-IT
6U1-IT-316
| 6″| 16″| 8.8″| 6.5″| 1
0824307| 7U1-IT| 7″| 14.7″| 8.3″| 6″| 1
0824308| 8U1-IT| 8″| 13.5″| 7.6″| 5.5″| 1
INSULATED TEE CAP
- Used to seal the base of an Insulated Tee.
- Easily removed for chimney maintenance or inspection.
- Insulated to maintain flue gas temperatures.
- Inner liner also available in 316 stainless steel 6″ diameter.
Product # | Part # | Size | A | B | Pack |
---|
0814506
0814506-316
| 6U1-ITC
6U1-ITC-316
| 6″| 8″| 6″| 10
0814507| 7U1-ITC| 7″| 9″| 7″| 10
0814508| 8U1-ITC| 8″| 10″| 8″| 10
Supports
- Used to support the chimney from a flat or cathedral ceiling.
- Will support up to 26′ of chimney.
- Decorative matte black finish.
Product #| Part #| Size| A| B| C| Support
Capacity| Pack
---|---|---|---|---|---|---|---
0842806| 6U1-SBCS| 6″| 24″| 6″| 10.25″| 26′| 1
0842807| 7U1-SBCS| 7″| 24″| 7″| 11.25″| 23′| 1
0842808| 8U1-SBCS| 8″| 24″| 8″| 12.25″| 20′| 1
CEILING/CATHEDRAL SUPPORT
SQUARE KITS INCLUDE :
- SQUARE CEILING SUPPORT
- U-SHAPE CEILING TRIM PLATES (2)
- SMOKE PIPE ADAPTER
- SUPPORT BRACKETS (4)
- HARDWARE PACK AND INSTRUCTIONS
Product #| Part #| Size| A| B| C| D|
Support Capacity| Pack
---|---|---|---|---|---|---|---|---
0844606| 6U1-RBCS| 6″| 24″| 6″| 10″| 19″| 26′| 1
0844607| 7U1-RBCS| 7″| 24″| 7″| 11″| 19″| 23′| 1
0844608| 8U1-RBCS| 8″| 24″| 8″| 12″| 19″| 20′| 1
ROUND KITS INCLUDE :
- ROUND CEILING SUPPORT
- ROUND SUPPORT COLLAR
- ROUND CEILING TRIM PLATE (1 PIECE)
- SMOKE PIPE ADAPTER
- SUPPORT BRACKETS (4)
- CUTTING TEMPLATE
- HARDWARE PACK AND INSTRUCTIONS
- Used to extend the Ceiling/Cathedral Support for steeper pitchB application.
- Attaches easily to Ceiling/Cathedral Support.
- Decorative matte black finish.
- Includes Hardware Pack for both (Square and Round).
Product # | Part # | Size | A | B | Pack |
---|
SUPPORT EXTENSION – SQUARE
0842906| 6U1-CSES| 6″| 10.25″| 24″| 1
0842907| 7U1-CSES| 7″| 11.25″| 24″| 1
0842908| 8U1-CSES| 8″| 12.25″| 24″| 1
SUPPORT EXTENSION – ROUND
0844806| 6U1-RBCSE| 6″| 10″| 24″| 1
0844807| 7U1-RBCSE| 7″| 11″| 24″| 1
0844808| 8U1-RBCSE| 8″| 12″| 24″| 1
CEILING/CATHEDRAL SUPPORT EXTENSION
Ceiling/Cathedral Support Extension – Square
SQUARE CEILING SUPPORT WITH ATTIC INSULATION SHIELD
- The Square Ceiling Support with Attic Insulation Shield is designed to be used only when an attic space is immediately above thissupport.
- This support in combination with the storm collar acts as an Attic Insulation Shield and provides 2″ clearance to combustibles.
- U-Shape Ceiling Trim Collar (2), Smoke Pipe Adapter, Support Brackets (4), Storm Collar, Hardware Pack and Instructions.
- Will support up to 20 feet of chimney.
Product # | Part # | Size | A | B | Pack |
---|---|---|---|---|---|
0842406 | 6U1-SCSC | 6″ | 12-3/8″ | 24″ | 1 |
0842407 | 7U1-SCSC | 7″ | 13-3/8″ | 24″ | 1 |
0842408 | 8U1-SCSC | 8″ | 14-3/8″ | 24″ | 1 |
SQUARE CEILING SUPPORT WITH ATTIC INSULATION SHIELD EXTENSION
- Used to extend the Square Ceiling Support with Attic Insulation Shield when the mimimum height requirement cannot be attained.
- Attaches easily to the Square Ceiling Support with Attic Insulation Shield.
- Includes Hardware Pack.
Product # | Part # | Size | A | B | Pack |
---|---|---|---|---|---|
0842506 | 6U1-SCSE | 6″ | 12-3/8″ | 24″ | 1 |
0842507 | 7U1-SCSE | 7″ | 13-3/8″ | 24″ | 1 |
0842508 | 8U1-SCSE | 8″ | 14-3/8″ | 24″ | 1 |
WALL SUPPORT
- Used to support the chimney system at the base of the installation when using an insulated tee where the chimney has a lateral connection.
- Will support up to 47′ of chimney (6″ diameter at 2″ from vertical wall). Refer to Table 2 in the instructions.
- Allows for an adjustment of 2″ to 6″ from a vertical wall.
- Includes Base Plate, 2 Wall Brackets, Tee Plug Retainer Clip (1), Hardware Pack and Instructions.
Product # | Part # | Size | A | B | C | Pack |
---|---|---|---|---|---|---|
0812806 | 6U1-WSP | 6″ | 17.1″ | 10.5″ | 14.7″ | 1 |
0812807 | 7U1-WSP | 7″ | 17.1″ | 11.5″ | 14.7″ | 1 |
0812808 | 8U1-WSP | 8″ | 17.1″ | 12.5″ | 14.7″ | 1 |
UNIVERSAL EXTENDED WALL SUPPORT
- Designed to support a vertical wall installation above the UNIVERSAL EXTENDED WALL SUPPORT insulated tee.
- Will support up to 28′ of chimney.
- Adjusts up to 12″ from a vertical wall and will allow the chimney to pass by a 12″ overhang.
- Available in Stainless Steel construction.
- Includes Support Band, 2 Lower Support Arms, 2 Upper Support
Arms, 2 Support Arm Brackets, Tee Cap Retainer, Hardware Pack and Instructions.
Product # | Part # | Size | A | B | Pack |
---|---|---|---|---|---|
0800200 | U1-UWRSA | 6″ – 8″ | 14″ | 12-3/8” | 10 |
A is the height of the leg support. B is the depth of the leg support
UNIVERSAL WALL SUPPORT / RESUPPORT ASSEMBLY
- Incorporates the flexibility to work on 6″, 7″, 8″ diameters and is an UNIVERSAL INTERIOR RESUPPORT excellent method for re-supporting chimney systems that have offsets or vertical runs that require additional support.
- Straps are 18″ in length.
- Will support up to 26′ of chimney.
- Includes Universal Band, 2 Support Straps, Hardware Pack and Instructions.
Product # | Part # | Size | A | B | Pack |
---|---|---|---|---|---|
0800300 | U1-UIRA | 6″ – 8″ | 18″ | 8″, 9″, 10″ | 10 |
UNIVERSAL INTERIOR RESUPPORT
- Designed to provide support at the roof and adjusts to any roof pitch. UNIVERSAL ROOF SUPPORT ASSEMBLY
- The Universal Band is pre-assembled for 6″ diameter chimney but will also fit 7″ and 8″ chimneys.
- Will support up to 30′ of chimney; 20′ of which can be suspended beneath it.
- Includes Universal Band, 2 Roof Brackets, Hardware Pack and Instructions.
Product # | Part # | Size | A | B | C | Pack |
---|---|---|---|---|---|---|
0800500 | U1-URSA | 6″, 7″, 8″ | 8″, 9″, 10″ | 5″ | 8″ | 1 |
UNIVERSAL ROOF SUPPORT ASSEMBLY
- Required where the chimney passes from a lower living space into an upper living space and into an attic space.
- Maintains the mandatory 2″ clearance to combustibles provided by proper framing.
Product #| Part #| Size| A| B| C| D|
E| F| Pack
---|---|---|---|---|---|---|---|---|---
FIRESTOP RADIATION / JOIST SHIELD – USA
0819006| 6U1-JS| 6″| 14″| 10.03″| 8.5″| 5″| 18″| 13″| 1
0819007| 7U1-JS| 7″| 15″| 11.03″| 9.5″| 5″| 18″| 13″| 1
0819008| 8U1-JS| 8″| 16″| 12.03″| 10.5″| 5″| 18″| 13″| 1
FIRESTOP RADIATION / JOIST SHIELD – CANADA
0819106| 6U1-JS-C| 6″| 14″| 10.03″| 8.5″| 5″| 18″| 13″| 1
0819107| 7U1-JS-C| 7″| 15″| 11.03″| 9.5″| 5″| 18″| 13″| 1
0819108| 8U1-JS-C| 8″| 16″| 12.03″| 10.5″| 5″| 18″| 13″| 1
ANCHOR PLATE
- Used to shield insulation when the chimney extends through a cathedral/sloped ceiling to the roof.
- Provides a 2″ clearance to combustibles. Trim Plate acts as a firestop and is adjustable to accommodate any angle.
- Extension available when greater coverage is required to reach roof level.
- 6″, 7″ & 8″ Sizes.
- Cathedral Insulation Shield, U-Shape Ceiling Trim, (2), Support Brackets (4) Hardware Pack and Instructions.
- Chimney length not included.
Product # | Part # | Size | A | B | Pack |
---|---|---|---|---|---|
0842706 | 6U1-CISS | 6″ | 12-3/8″ | 24″ | 1 |
0842707 | 7U1-CISS | 7″ | 13-3/8″ | 24″ | 1 |
0842708 | 8U1-CISS | 8″ | 14-3/8″ | 24″ | 1 |
Shields
FIRESTOP RADIATION / JOIST SHIELD
- USA : Used for fireplace and stove installations.
- Canada : Used for fireplace installations.
NOTE : See installation instructions for framing dimensions.
CATHEDRAL INSULATION SHIELD
- Can be used as a substitute instead of the regular AIS when a fully ALTERNATE ATTIC INSULATION SHIELD
- open attic is immediately above a Round Ceiling Support.
- Fits perfectly over the Round Ceiling Support to allow the Universal Shielding Insulation (SUSI/JUSI) to be installed.
- Will adjust to allow for a depth of insulation up to 16.5″.
- Includes an AIS Storm Collar.
ATTIC INSULATION SHIELD
- Must be installed where the chimney enters the attic space in a ceiling ATTIC INSULATION SHIELD supported (interior) installation.
- Designed to keep insulation away from the chimney, and to maintain the mandatory 2″ clearance to combustibles provided by proper framing.
- Includes an AIS Storm Collar.
- Will adjust to allow for a depth of insulation up to 18.5″.
Product #| Part #| Size| A| B| C| D|
E| Pack
---|---|---|---|---|---|---|---|---
0843406| 6U1-AIS| 6″| 8″| 12.2″| 11″ – 20″| 7″| 14″| 1
0843407| 7U1-AIS| 7″| 9″| 13.2″| 11” – 20”| 7″| 15″| 1
0843408| 8U1-AIS| 8″| 10″| 14.2″| 11” – 20”| 7″| 16″| 1
ALTERNATE ATTIC INSULATION SHIELD
Product # | Part # | Size | A | B | C | Pack |
---|---|---|---|---|---|---|
0843506 | 6U1-AAIS | 6″ | 18” | 12″ | 8″ | 1 |
0843507 | 7U1-AAIS | 7″ | 18″ | 13″ | 9″ | 1 |
0843508 | 8U1-AAIS | 8″ | 18″ | 14″ | 10″ | 1 |
INSULATED WALL THIMBLE
- Required where the chimney passes horizontally through a combustible wall.
- Will accommodate a wall thickness of 12”.
- Adjustable Trim Cap in a decorative matte black finish.
- Matte black finish Trim Collar.
- Factory installed insulation between shields.
Product #| Part #| Size| A| B| C| D|
E| F| Pack
---|---|---|---|---|---|---|---|---|---
0828706| 6U1-IWT| 6″| 14″| 12″| 9″| 6.2″| 10.8″| 19″| 1
0828707| 7U1-IWT| 7″| 15″| 12″| 9″| 7.2″| 11.8″| 22″| 1
0828708| 8U1-IWT| 8″| 16″| 12″| 9″| 8.2″| 12.8″| 22″| 1
DECORATOR SLEEVE
- Used to provide a decorative finish to the horizontal length within the room when passing through a non-combustible wall.
- Adjustable Trim Cap in a decorative matte black finish.
Product # | Part # | Size | A | B | Pack |
---|---|---|---|---|---|
0817806 | 6U1-DS9 | 6″ | 8″ | 6.2″ | 1 |
0817807 | 7U1-DS9 | 7″ | 8″ | 7.2″ | 1 |
0817808 | 8U1-DS9 | 8″ | 8″ | 8.2″ | 1 |
Flashings and Storm Collars
ROOF FLASHING SELECTION CHART
- To determine what roof flashing you’ll require, you must work out the pitch of your roof.
- To determine the pitch, you’ll need two rulers and a level. Measure the number of inches from the end of the level down to the roof.
VENTED FLASHING ASSEMBLY
- Special Vented Flashing.
- Listed to CAN/ULC-S629.
- Required for use in fully enclosed attic or exterior chase.
- Used where the chimney passes through a roof with a pitch of 0/12 to 6/12 and 7/12 to 12/12.
- Storm Collar included.
- Roof Shield included with 0/12 to 6/12 roof pitch flashings.
Product #| Part #| Size| A| B| C| D|
Pack
---|---|---|---|---|---|---|---
ROOF PITCH 0/12 TO 6/12
0843306| 6U1-AF6-C| 6″| 9″| 21″| 6″| 9.3″| 1
0843307| 7U1-AF6-C| 7″| 10″| 21″| 6″| 9.3″| 1
0843308| 8U1-AF6-C| 8″| 11″| 21″| 6″| 9.3″| 1
ROOF PITCH 7/12 TO 12/12
0843706| 6U1-AF12-C| 6″| 9.3″| 20.5″| 6″| 10″| 1
0843707| 7U1-AF12-C| 7″| 10.3″| 22.3″| 6″| 10″| 1
0843708| 8U1-AF12-C| 8″| 11.3″| 24″| 6″| 10″| 1
NON-VENTED FLASHING ASSEMBLY
- Used where the chimney passes through a roof with a pitch of 0/12 to 2/12, 2/12 to 6/12 and 6/12 to 12/12.
- Storm Collar included.
- Roof Shield included (0/12 to 2/12 roof pitch).
Product #| Part #| Size| A| B| C| D|
E| Pack
---|---|---|---|---|---|---|---|---
ROOF PITCH 0/12 TO 2/12 – Includes: Roof Shield
0843106| 6U1-UVTF| 6″| 8.5″| 12.25″| 24″| 21.25″| 10.2″| 1
0843107| 7U1-UVTF| 7″| 9.5″| 15.75″| 24.75″| 24″| 11″| 1
0843108| 8U1-UVTF| 8″| 10.5″| 15.75″| 27.75″| 24″| 10.7″| 1
ROOF PITCH 2/12 TO 6/12
0843206| 6U1-UVAF6| 6″| 8.5″| 16.5″| 28.5″| 24″| 7.2″| 1
0843207| 7U1-UVAF6| 7″| 9.5″| 16.5″| 28.5″| 24″| 6.9″| 1
0843208| 8U1-UVAF6| 8″| 10.5″| 20″| 32″| 27″| 8.4″| 1
ROOF PITCH 6/12 TO 12/12
0843606| 6U1-UVAF12| 6″| 8.5″| 20″| 32″| 27″| 6.5″| 1
0843607| 7U1-UVAF12| 7″| 9.5″| 20″| 32″| 27″| 7.4″| 1
0843608| 8U1-UVAF12| 8″| 10.5″| 20″| 32″| 27″| 5.6″| 1
FLASHING ASSEMBLY
- Used where the chimney passes through a roof with a pitch of 12/12 FLASHING ASSEMBLY to 24/12 and 24/12 to 36/12.
- Safety Vents on flashing.
- Storm Collar sold separately.
Product # | Part # | Size | A | B | C | Pack |
---|
ROOF PITCH 12/12 TO 24/12
206835| 6TAF-24| 6″| 8-1/8″| 40.9″| 28.9″| 1
207835| 7TAF-24| 7″| 9-1/8″| 43.3″| 31.3″| 1
208835| 8TAF-24| 8″| 10-1/8″| 45.4″| 33.4″| 1
ROOF PITCH 24/12 TO 36/12
206840| 6TAF-36| 6″| 8-1/8″| 53.3″| 43.3″| 1
207840| 7TAF-36| 7″| 9-1/8″| 56.3″| 44.2″| 1
208840| 8TAF-36| 8″| 10-1/8″| 59.9″| 47.9″| 1
DEAD SOFT FLASHING
- Used on corrugated or tiled roofs.
- Safety Vents on flashing.
- Storm Collar sold separately.
Product #| Part #| Size| A| B| C| D|
Pack
---|---|---|---|---|---|---|---
ROOF PITCH 2/12 TO 6/12
206845| 6T-AF6D| 6″| 8-1/8″| 16.5″| 30″| 33″| 1
207845| 7T-AF6D| 7″| 9-1/8″| 16.5″| 30″| 33″| 1
208845| 8T-AF6D| 8″| 10-1/8″| 19.9″| 30″| 33″| 1
ROOF PITCH 7/12 TO 12/12
206850| 6T-AF12D| 6″| | | 32″| 33″| 1
207850| 7T-AF12D| 7″| | | 32″| 33″| 1
208850| 8T-AF12D| 8″| | | 32″| 33″| 1
RUBBER BOOT FLASHING KITS (UNIV)
- Used for installations on corrugated roofs with pitches flat to 12/12 RUBBER BOOT FLASHING KITS (UNIV) except for 8″ Chimney where 10/12 is max. pitch.
- Kits include rubber boot, spacer kit, special storm collar and mounting hardware.
Product # | Part # | Size | Dimension | Pack |
---|---|---|---|---|
200275 | URBAK1 | 6″ TO 8″ | 26-3/4″ X 26-3/4″ | 1 |
METAL ROOF FLASHING KIT (UNIV)
- Used in conjunction with the above metal flashings to seal the opening when penetrating a corrugated metal roof.
- Supplied with 2 – 90° bend metal strips (30″ x 2″ x 2″) and grey sealant tape.
- Flashing and Storm Collar sold separately.
Product # | Part # | Size | Pack |
---|---|---|---|
200280 | URFK | 6″ TO 8″ | 1 |
STORM COLLAR – CANADA ONLY
- Used in conjunction with roof flashing to weather proof the system.
- Use with ULC-S629 Flashings (Models U1-AF6-C and U1-AF12-C).
- Asterisk denotes diameter: 6″, 7″ or 8″.
- Storm Collar is tightened by adjusting tabs after proper positioning.
Product # | Part # | Size | A | Pack |
---|---|---|---|---|
0814206 | 6U1-SC-C | 6″ | 8″ | 10 |
0814207 | 7U1-SC-C | 7″ | 9″ | 10 |
0814208 | 8U1-SC-C | 8″ | 10″ | 10 |
STORM COLLAR – (FOR REGULAR FLASHINGS)
- Used in conjunction with U1-UVTF / U1-UVAF6 / U1-UVAF12 / TAF-24 / TAF-36 / T-AF6D roof flashings listed on pages 14 and 15 to weather proof the system.
- Storm Collar is tightened by adjusting tabs after proper positioning.
Product # | Part # | Size | A | Pack |
---|---|---|---|---|
206810 | 5/6T-SC | 6″ | 7″/8″ | 10 |
208810 | 7/8T-SC | 7″/8″ | 9″/10″ | 10 |
FLASHING – STORM COLLAR COMBO PACKS
Product # | Part # | Size | Dimensions |
---|
3 Per Carton
0843336| 6U1 AF6SC-C| 6″| Vented Flashing 0/12 – 6/12 w/SC ULC S629
0843337| 7U1 AF6SC-C| 7″| Vented Flashing 0/12 – 6/12 w/SC ULC S629
0843338| 8U1 AF6SC-C| 8″| Vented Flashing 0/12 – 6/12 w/SC ULC S629
0843736| 6U1 AF12SC-C| 6″| Vented Flashing 7/12 – 12/12 w/SC ULC S629
---|---|---|---
0843737| 7U1 AF12SC-C| 7″| Vented Flashing 7/12 – 12/12 w/SC ULC S629
0843738| 8U1 AF12SC-C| 8″| Vented Flashing 7/12 – 12/12 w/SC ULC S629
4 Per Carton
0843136| 6U1 UVTFSC| 6″| Unvented Flashing Assy 0/12 – 2/12 pitch w/SC
0843137| 7U1 UVTFSC| 7″| Unvented Flashing Assy 0/12 – 2/12 pitch w/SC
0843138| 8U1 UVTFSC| 8″| Unvented Flashing Assy 0/12 – 2/12 pitch w/SC
0843236| 6U1 UVAF6SC| 6″| Unvented Flashing Assy 2/12 – 6/12 pitch w/SC
---|---|---|---
0843237| 7U1 UVAF6SC| 7″| Unvented Flashing Assy 2/12 – 6/12 pitch w/SC
0843238| 8U1 UVAF6SC| 8″| Unvented Flashing Assy 2/12 – 6/12 pitch w/SC
0843636| 6U1 UVAF12SC| 6″| Unvented Flashing Assy 6/12 – 12/12 pitch w/SC
---|---|---|---
0843637| 7U1 UVAF12SC| 7″| Unvented Flashing Assy 6/12 – 12/12 pitch w/SC
0843638| 8U1 UVAF12SC| 8″| Unvented Flashing Assy 6/12 – 12/12 pitch w/SC
Rain Cap
ROUND TOP TERMINATION CAP – STAINLESS STEEL
- Part of the chimney system roof assembly, the Round Top is designed with a dome to exclude rain and leaves and a lower skirt to deflect wind for proper chimney draft.
- The Round Top is designed with three legs that slide down over the outside of the chimney. A cinch band is then positioned over the legs and tightened to hold the top firmly in place. This design makes cap removal for cleaning a breeze.
- Made of stainless steel.
- Inner Stub of Round Top available in 316 stainless steel for 6″ diameter only.
Product # | Part # | Size | A | B | C | Pack |
---|
0827606
0827606-316
| 6U1-CT
6U1-CT-316
| 6″| 8″| 12″| 5.5″| 1
0827607| 7U1-CT| 7″| 9″| 14″| 6.3″| 1
0827608| 8U1-CT| 8″| 10″| 16″| 7″| 1
Parts and Accessories
SPARK ARRESTER
Product # | Part # | Size | Pack |
---|---|---|---|
206791 | 6T-USA | 6″ | 1 |
207791 | 7T-USA | 7″ | 1 |
208791 | 8T-USA | 8″ | 1 |
- Corrosion resistant diamond mesh Stainless Steel.
- Preformed.
- Slip over the dome of the Round Top.
Product # | Part # | Size | A | B | Pack |
---|---|---|---|---|---|
206480 | 6T-FC | 6″ | 6.3” | 8″ | 4 |
207480 | 7T-FC | 7″ | 7.3″ | 9″ | 4 |
208480 | 8T-FC | 8″ | 8.3″ | 10″ | 4 |
FINISHING COLLAR
- Used to fit over lower end of suspended insulated chimney pipe to provide finished appearance.
- Matte black finish.
Product # | Part # | Size | A | B | Pack |
---|
0819806
0819806-316
| 6U1-SPA
6U1-SPA-316
| 6″| 3.7”| 6″| 1
0819807| 7U1-SPA| 7″| 3.7″| 7″| 1
0819808| 8U1-SPA| 8″| 3.7″| 8″| 1
SMOKE PIPE ADAPTOR
- For transition from black stove pipe to UltimateONE chimney.
- Includes black pipe stub and the retainer ring.
- Stainless steel construction. Also available in 316 stainless steel for 6″ diameter only
Product # | Part # | Size | A | B | Pack |
---|
0819806
0819806-316
| 6U1-SPA
6U1-SPA-316
| 6″| 3.7”| 6″| 1
0819807| 7U1-SPA| 7″| 3.7″| 7″| 1
0819808| 8U1-SPA| 8″| 3.7″| 8″| 1
TRIM PLATE CEILING SPACER – USA ONLY
- Used to trim ceiling, closing off the airspace around the pipe when the chimney is supported from above and extended down into the room.
- Used in conjunction with an Attic Insulation Shield.
- Black matte finish.
Product # | Part # | Size | A | B | C | Pack |
---|---|---|---|---|---|---|
206488 | 6UT-TPS | 6″ | 19″ | 12″ | 8.1″ | 1 |
207488 | 7UT-TPS | 7″ | 21″ | 13″ | 9.1″ | 1 |
208488 | 8UT-TPS | 8″ | 22″ | 14″ | 10.1″ | 1 |
ADJUSTABLE PITCHED CEILING PLATE – USA ONLY
- Pitched Ceiling Plate provides a finished appearance where the chimney passes through a sloped ceiling.
- Only two parts required to fit the full range of pitches.
- Black matte finish.
Product # | Part # | Size | A | B | Pack |
---|
CEILING PITCH 0/12 TO 6/12
206512| 6UT-PCPAJ| 6″| 16.5″| 19″ – 30″| 1
207512| 7UT-PCPAJ| 7″| 17.5″| 20″ – 31″| 1
208512| 8UT-PCPAJ| 8″| 18.5″| 21″ – 33″| 1
CEILING PITCH 7/12 TO 12/12
206514| 6UT-PCPAJ12| 6″| 16.5″| 19″ – 30″| 1
207514| 7UT-PCPAJ12| 7″| 17.5″| 20″ – 31″| 1
208514| 8UT-PCPAJ12| 8″| 18.5″| 21″ – 33″| 1
ROUND TRIM COLLAR
- Used to close off space around pipe in a non-combustilbe wall ROUND TRIM COLLAR installation.
- Matte black finish.
Product # | Part # | Size | A | B | Pack |
---|---|---|---|---|---|
0843806 | 6U1-TC | 6″ | 19″ | 10.9″ | 1 |
0843807 | 7U1-TC | 7″ | 22″ | 11.9″ | 1 |
0843808 | 8U1-TC | 8″ | 22″ | 12.9″ | 1 |
CLEANOUT TEE
- Always situated in a room with heating appliance.
- Cap on bottom can be removed for easy cleaning.
- Stainless steel construction.
Product # | Part # | Size | A | B | C | Pack |
---|---|---|---|---|---|---|
0514706 | 6CF-CA | 6″ | 6″ | 13.5″ | 24″ | 4 |
0514707 | 7CF-CA | 7″ | 7″ | 13.5” | 25″ | 4 |
0514708 | 8CF-CA | 8″ | 8″ | 13.5” | 26″ | 4 |
REPLACEMENT TEE CAP FOR CLEANOUT TEE
Product # | Part # | Size | Pack |
---|---|---|---|
0850606 | 6U1-STC | 6″ | 10 |
0850607 | 7U1-STC | 7″ | 10 |
0850608 | 8U1-STC | 8″ | 10 |
UNIVERSAL WALL BAND
- Provides lateral support for the chimney when installed adjacent to a wall.
- Provides more than 4″ of horizontal adjustability to clear some overhangs and obstructions.
- Required at 8 foot or closer intervals to stabilize the chimney, whenever it is supported along a vertical wall.
Product # | Part # | Size | A | B | C | Pack |
---|---|---|---|---|---|---|
0800700 | U1-UWB | Universal | 8″, 9″ & 10″ | 17″ | 4″ | 10 |
*0800700S | U1-UWBSS | Universal | 8″, 9″ & 10″ | 17″ | 4″ | 10 |
*Stainless steel construction
WALL BAND
- Provides lateral support for the chimney when installed adjacent to a wall.
- Maintains the mandatory 2″ clearance to combustibles.
- Required at 8 foot or closer intervals to stabilize the chimney, whenever it is supported along a vertical wall.
- Stainless steel construction.
Product # | Part # | Size | A | B | Pack |
---|---|---|---|---|---|
0818806 | 6U1-WB | 6″ | 8.1″ | 17″ | 10 |
0818807 | 7U1-WB | 7″ | 9.1″ | 17″ | 10 |
0818808 | 8U1-WB | 8″ | 10.1″ | 17″ | 10 |
UNIVERSAL TEE CAP RETAINER
- Used to secure tee cap on the bottom side of Insulated Tee when suspended.
- Adjusts to fit all chimney diameters.
Product # | Part # | Size | Pack |
---|---|---|---|
2002530 | UTCR | 6″ to 8″ | 4 |
HD UNIVERSAL ROOF BRACE KIT
- Designed to provide extra stability for chimney system above roof line.
- Required when the chimney extends 5 feet or more above the roof. Use one kit every 5 feet.
- Telescoping legs can adjust from 5′ to 9′.
- Support band adjusts to fit 6″, 7″, and 8″ chimney.
Product # | Part # | Size | Pack |
---|---|---|---|
0843900 | HDRBK | 6″ to 8″ | 1 |
SNOW SPLITTER ASSEMBLY
- Designed to deflect snow and ice while preventing unnecessary strain SNOW SPLITTER ASSEMBLY or damage to chimney.
- Mounts directly above chimney pipe with easy panel assembly.
- Made from heavy gauge galvanized steel.
Product # | Part # | Size | Pack |
---|---|---|---|
2001922 | USSA | 6″ to 8″ | 1 |
UNIVERSAL SHIELDING INSULATION
- The SUSI protects building materials against radiant heat from the chimney and helps maintain temperatures within the chimney system.
- The SUSI also reduces air infiltration into the house.
- Dimension is 48″ x 12″ x 2″.
Product # | Part # | Size | Pack |
---|---|---|---|
0522908 | SUSI | Universal | 1 |
UNIVERSAL WALL CHANNEL
- The use of one or more Wall Channels will simplify the installation of UNIVERSAL WALL CHANNEL the Extended Wall Support, Universal Wall Re -Support or Wall Band when framing members are not within range.
- 26″ in length to allow for 24″ on center construction.
Product # | Part # | A | B | Pack |
---|---|---|---|---|
0800800 | WC | 26″ | 2-1/4″ | 10 |
Components Specific to Canada Only
RIGID SUPPLEMENTAL RADIATION SHIELD – ENCLOSED CHIMNEY SYSTEM – CANADA ONLY
- Used only when the chimney is enclosed within living spaces and when the chimney is enclosed in an attic space.
- NOTE : Not required in an enclosed exterior chase.
- Ideal for straight up installation.
- Telescoping Length from 43″ to 103″.
NOTE : Not required when UltimateONE is used to vent an oil or a gas burning appliance even when the chimney is enclosed.
Product #| Part #| Size| A| B| C| D|
Pack
---|---|---|---|---|---|---|---
0850106| 6U1-RSRS| 6″| 9.9″| 10.5″| 10.3″| 10.1″| 1
0850107| 7U1-RSRS| 7″| 10.9″| 11.5″| 11.3″| 11.1″| 1
0850108| 8U1-RSRS| 8″| 11.9″| 12.5″| 12.3″| 12.1″| 1
SUPPLEMENTAL RADIATION SHIELD – RIGID TEE – CANADA ONLY
- Used only when the chimney is enclosed within a living space.
- NOTE: Not required in an enclosed exterior chase.
- Shield held together using supplied screws and comes in two separate pieces.
- NOTE: Not required when UltimateONE is used to vent an oil or a gas burning appliance even when the chimney is enclosed
Product #| Part #| Size| A| B| C| D|
Pack
---|---|---|---|---|---|---|---
0850206| 6U1-RSRST| 6″| 13.5″| 10″| 7.0″| 5.8″| 1
0850207| 7U1-RSRST| 7″| 14.7″| 11″| 7.5″| 6.4″| 1
0850208| 8U1-RSRST| 8″| 16.0″| 12″| 8.0″| 7.0″| 1
FLEXIBLE SUPPLEMENTAL RADIATION SHIELD – CANADA ONLY
- Used only when the chimney is enclosed within living spaces and when the chimney is enclosed in an attic space.
- NOTE : Not required in an enclosed exterior chase.
- Ideal for offset installation but can also be used in lieu of the Rigid Supplemental radiation Shield.
- Flexible Length from 26″ to 78″ (packed 2 per carton).
- NOTE : Not required when UltimateONE is used to vent an oil or a gas burning appliance even when the chimney is enclosed.
Product #| Part #| Size| A| B| C| D|
Pack
---|---|---|---|---|---|---|---
0850206| 6U1-RSRST| 6″| 13.5″| 10″| 7.0″| 5.8″| 1
0850207| 7U1-RSRST| 7″| 14.7″| 11″| 7.5″| 6.4″| 1
0850208| 8U1-RSRST| 8″| 16.0″| 12″| 8.0″| 7.0″| 1
SHIELD TRANSITION PIECE (4)
- Shield Transition Pieces provide a smooth connection from a square support to a round supplemental shield.
Product # | Part # | Pack |
---|---|---|
0850300 | U1-STP | 1 |
INSULATED CHASE PLUG
- Recommended to reduce air infiltration through the chase in cold climates.
- Maintains the thermal envelope of your home.
- For use with wood-burning fireplaces certified with UltimateONE chimney.
- A trim plate is provided when a 6″ chimney is used.
- Used with specific factory-built fireplaces listed to UL 127 or CAN/ULC-S610.
30°/45° INSULATED WALL PLUG
- For use where the chimney passes through a wall at a 30° & 45° 30°/45° INSULATED WALL PLUG angle.
- Insulated to maintain the thermal envelope of your home.
- For use with wood-burning fireplaces certified with UltimateONE chimney.
- A trim plate is provided – to be used when a 6″ diameter chimney is used with 30° or 45° angle or when a 7″ diameter chimney is used with 45° angle.
- Used with specific factory-built fireplaces listed to UL 127 or CAN/ULC-S610.
Size | A | B | C | Product Code | Pack |
---|---|---|---|---|---|
6″ & 7″ | 15″ | 15″ | 4-1/4″ | JSC7CP | 1 |
NOTE: 45º angle can only be used in Canada.
The following are four basic Chimney Kits designed around one of the standard support systems. Select the kit that is best suited for your installation along with the required Chimney Lengths to reach your desired height and a suitable Adjustable Flashing from our vast selection. Other components may be required such as Elbows, Firestop Radiation/Joist Shields, Universal Roof Brace Kit, etc.
CEILING/CATHEDRAL SUPPORT KIT
These kits provide the support and termination parts required for a chimney system that is supported by a flat or cathedral ceiling and passes through an attic area and penetrates the roof.
Product # | Part # | Size | Parts Included in Kit |
---|
SUPPORT KIT – SQUARE
0842206| 6U1-SCSK| 6″| • Attic Insulation Shield (AIS)
• Ceiling/Cathedral Support – Square (SBCS)
• Round Top Termination Cap (CT)
• Smoke Pipe Adapter (SPA)
0842207| 7U1-SCSK| 7″
0842208| 8U1-SCSK| 8″
SUPPORT KIT – ROUND
0844706| 6U1-CSK| 6″| • Attic Insulation Shield (AIS)
• Ceiling/Cathedral Support – Round (RBCS)
• Round Top Termination Cap (CT)
• Smoke Pipe Adapter (SPA)
• NOTE: In the CSK-316 Kit, the CT and SPA are 316 stainless steel
0844706-316| 6U1-CSK-316| 6″
0844707| 7U1-CSK| 7″
0844708| 8U1-CSK| 8″
WALL SUPPORT KIT
This kit is used for a wall-supported chimney system with a horizontal connection passing through an exterior wall, connecting to an Insulated Tee and running vertically up the exterior wall to terminate above the roof line.
Product # | Part # | Size | Parts Included in Kit |
---|---|---|---|
0829806 | 6U1-WSK | 6″ | • Wall Support (WSP) |
• Insulated Tee w/Insulated Tee Cap (IT)
• Insulated Wall Thimble (IWT)
• Wall Band (WB)
• Smoke Pipe Adapter (SPA)
• Round Top Termination Cap (CT)
• NOTE: In the WSK-316 Kit, the CT and SPA are 316 stainless steel
0829806-316| 6U1-WSK-316| 6″
0829807| 7U1-WSK| 7″
0829808| 8U1-WSK| 8″
EXTENDED WALL SUPPORT KIT
This kit is used for a through-the-wall installation where the insulated tee is suspended below and support the vertical system above. It allows the chimney to pass by a 12″ overhang.
Product # | Part # | Size | Parts Included in Kit |
---|---|---|---|
0829906 | 6U1-EWSK | 6″ | • Extended Wall Support (EWT) |
• Insulated Tee w/Insulated Tee Cap (IT)
• Insulated Wall Thimble with Trim Collar (IWT)
• Wall Band (WB)
• Smoke Pipe Adapter (SPA)
• Round Top Termination Cap (CT)
• Tee Cap Retainer (TCR)
0829907| 7U1-EWSK| 7″
0829908| 8U1-EWSK| 8″
Customer Service and Support
- Airmate (USA)……………………………………… 800.992.8368
- Airmate (CAN)………………………………………888.735.5475
- Ameriflow………………………………………………800.252.8467
- Amerivent (Retail)……………………………….800.252.8467
- Amerivent (Hearth & Wholesale)….. 800.423.4270
- Amerivent (Support)…………………………..800.748.0392
- AMPCO (USA)……………………………………….800.669.3269
- AMPCO (CAN)……………………………………….888.735.5475
- Duravent………………………………………………. 800.835.4429
- Hart & Cooley………………………………………. 800.433.6341
- Hart & Cooley (Support)…………………….800.748.0392
- Heatfab (USA)……………………………………….800.772.0739
- Heatfab (CAN)………………………………………800.848.2149
- Lima……………………………………………………….. 800.423.4270
- Milcor………………………………………………………800.774.5240
- Portals Plus……………………………………………800.774.5240
- RPS………………………………………………………….800.624.8642
- Security Chimney (USA)……………………800.361.4909
- Security Chimney (CAN)……………………800.667.3387
- Selkirk (USA) Residential…………………. 800.992.8368
- Selkirk (USA) Commercial……………….. 800.848.2149
- Selkirk (USA) Support…………………………800.748.0392
- Selkirk (CAN)………………………………………..888.735.5475
Manufacturing & Distribution Centers
CANADA
- Nobel, ON Manufacturing
- Laval, QC Manufacturing
- Prescott, ON Distribution
USA
- Grand Rapids, MI Center of Excellence
- Dallas, TX Distribution
- Englewood, OH Distribution
- Huntsville, AL Manufacturing & Distribution
- Mira Loma, CA Distribution
- Nampa, ID Manufacturing & Distribution
- Turner Falls, MA Manufacturing & Distribution
- Vacaville, CA Manufacturing
MEXICO
Ojinaga, MX Manufacturing Mexicali, MX Manufacturing
Corporate Headquarters :
Duravent Group 28 W. Adams, Suite 1810 Detroit, MI 48226
Tel : 800.835.4429
Email: info@duraventgroup.com
www.duraventgroup.com
800.992.8368 (US) 888.735.5475 (CAN) | Selkirk by Duravent
© 2023 Duravent Group. All rights reserved. SK_U1_CT-001E_10-23
Selkirk by Duravent | www.selkirkcorp.com (US) www.selkirkcorp.ca (CAN)
© 2023 Duravent Group. All rights reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>