OCRW IIS00347 Oncurve Instruction Manual
- June 16, 2024
- OCRW
Table of Contents
OCRW 2×4 / 4×4 Series
Recessed Installation Instructions
ERP: IIS00347
Date: 04/12/2022
Rev 1.0
IIS00347 Oncurve
NOTES
- Installation should be completed by an individual familiar with the construction and operation of the luminaire.
- Installation of luminaire must be in accordance with nation and local building and electrical codes.
- Carefully read and follow all warnings and instructions before installing or servicing the luminaire.
- Instructions do not cover all details and all possible product configurations
- Do not restrict luminaire ventilation.
- Ensure LED luminaire is not covered with material that will prevent convection or conduction cooling.
- Do not exceed luminaire’s maximum ambient temperature.
- Ensure LED luminaire has the correct polarity before installation.
- These products have maximum rated output voltage that exceeds the voltage limits that cannot be accessible based on voltage restrictions for Class 2 circuits in Canadian Electrical Code. This output complies with the definition of Class 2 per Canadian Electrical Code. This product complies with this requirement since the installation instruction requires installation in restricted access area.
- Do not mount the luminaire to ceiling if convenience outlet option is provided.
- Do not use the luminaire housing as junction box cover unless the housing width is wider than the junction box.
WARNINGS
Electric shock:
- Disconnect or turn off power before installing or servicing luminaire.
- Fixture should ONLY be powered on with access plate installed in fixture.
- All electrical wiring to be completed by a qualified licensed electrician in accordance with local and National/Canadian Electrical Code.
- Ensure supply voltage corresponds with the correct ballast/driver voltage.
- Avoid exposing wiring to metal edges and sharp objects.
- Ensure that the luminaire is properly grounded to prevent electric hazards.
- Before powering up fixture, perform appropriate testing to ensure the fixture is properly grounded
Fire:
- Keep flammable and combustible materials away from the light source and/or lens.
- Use correctly rated supply conductors as indicated by product labeling.
Burn:
- Allow luminaire to cool before handling luminaire. Personal Injury:
- Wear safety glasses and gloves when handling the luminaire to avoid physical injury.
- Avoid direct eye contact with light source.
- Always support the weight of the luminaire.
Manufacturer is not responsible for any injuries due to the improper installation or handling of its products.
Cleaning and Maintenance
- Use a damp, lint-free cloth to wipe lens. Don not use solvents or cleaners containing abrasive agents. When cleaning the fixture, make sure the power is turned off, and any liquid spray should be applied to the cleaning cloth and not sprayed directly onto the fixture itself.
INSTRUCTIONS:
Mounting:
- Disconnect electrical power intended to be connected to the luminaire.
- Remove the concave and convex lens and .
- Insert the luminaire into the T-Bar grid ceiling from room side.
- Secure luminaire with grid wire/chains to the structure above per local and/or national building codes.
- Remove access plate and appropriate K.O.’s for attachment of electrical power feed cable connectors (by others).
- Make the necessary wiring connections and ground connections per local and national electrical building codes.
- Reattach access plate to luminaire and secure access plate screw, ensuring that screw is inserted through clearance hole and into extruded hole.
- Re-install lens.
- Apply power.