U King RGBY Four Tunnels Laser Show System User Manual

June 16, 2024
U King

RGBYFOURTUNNELSLASERSHOWSYSTEM
User ManualU King RGBY Four Tunnels Laser Show
System

Read this manual befo Do not attempt to open the housing or repair this dePvicEbRy yourself without contact us!

General instructions

Unpacking:
Thank you for purchasing this product. Please read user guide for safety and before using the product. Keep this manual for future reference. This product can create perfect laser programs and effects since it has passed a series of strictly tests before delivery. Please check the attachments listed on the page after opening the carton. Immediately upon receiving a fixture, carefully unpack the box. Check the box contents to ensure that all parts are present and that they are in good condition. If any part appears damaged from shipping, or if the box shows signs of mishandling, notify the shipper immediately. In addition, retain the box and all the packing material for inspection.In any event, save the carton and all packing material because, in case that you have to return the fixture to the factory, you will have to do so in its original box, with it original packing.

  1. Laser Light: 1PCS
  2. Power Cable: 1PCS
  3. User Guide: 1PCS

Technical Specification

  1. Voltage: bi-voltage 110\ -220V-250V” AC, 50HZ-60HZ/ Fuse: 2A/250V”

  2. Rated Power: 30W

  3. Laser:
    Color|  Wavelength| Power output
    ---|---|---
    Red| 650nm|
    Green| 5320m|
    Blue| 450nm|
    Yellow| |

  4. Laser class: Class ITIB

  5. Working Modes: DMX, Sound Active, AUTO, Master-Slave

  6. DMX Control Channel: 11 channels

  7. Graphics & Effects: More than 100 patterns with blended beam effect from four apertures.
    Each lens laser beam can be shown one by one from four apertures, or scan separately towards different direction on systematic procedure.

  8. Interface: 3 pins XLR jack for DMX or Maser-Slave linking

  9. Item Size: 58018590mm

  10. Net weight:5.8kg

  11. Gross weight:6.4Kg

  12. Tnner box:49.5%2436.5, outer box: 51.3%2436.5, 2pes/carton

Laser Expected Lifespan
Laser gradually decline in brightness over time. HEAT s the dominant factor that leads to the acceleration of this decline. Packaged in clusters, laser exhibit higher operating temperatures than in ideal or singular optimum conditions. For this reason when all color lasers are used at their fulles intensity, life of the laser is significantly reduced. It is estimated that a viable lifespan of 4,000 to 10,000 hours will be achieved under normal operational conditions. If improving on this lifespan expectancy is of a higher priority, place care in providing for lower operational temperatures. This may include climatic-environmental and the reduction of overall projection intensity.
Safty Notice:
Please read the following notes carefully because they include important safety information about the installation,usage and maintenance of this product. It is important to read all these notes before starting to work with this product.
Lasers can be hazardous and have unique safety considerations. Permanent eye injury and blindness is possible if lasers are used incorrectly. Pay close attention to each safety REMARK and WARNING statement in the user mamual. Read all instructions careful.

| There are no user serviceable parts inside the light. Any reference to servicing this unit you may find from now on in this User Manual will only apply to properly
consult we certified technicians. Do not open the housing or attempt any repairs unless you
---|---
| Avoid direct eye exposure to the light source while the fixture is on. Always disconnect the light from its power source before servicing. Always connect the light to a grounded circuit to avoid the risk of electrocution.
| This product is for indoor use only! Use only in dry locations. Keep this device away from rain and moisture, excessive heat, humidity and dust. Do not allow contact with water or any other fluids, or metallic objects.
Power
110v 240V
Ground| Atvays make sure that you are connecting the light to the proper voltage, as per the specifications in this manual or on the product’s sticker. Never connect the
ieht toa dimmer pack. Make sure that the power cable is not cracked, crimped or damaged. Ne
| ‘The maximum ambient temperature (Ta) is 104 F (40 C). Do not operate the fixture at a higher temperature. In case of a serious operating problem, stop using this product immediately!
| Do not remove or break the warranty label, otherwise it void the warranty.
| Always replace with the exact same type fuse, replacement with anything other than the specified fuse can cause fire or electric shock and damage your unit, and will void your manufactures warranty.
| There are no serviceable parts in the light. Please have all servicing and adjustments made by a qualified service engineer.
| Please refer to all applicable local codes and regulations for
proper installation of the light| | Keep this manual for future consultation. If you sell the light to another user, make sure that they also receive this manual.
| Make sure there are no flammable materials close to the fixture(s) while operating.| | Please prevent this light away from electrical shock
| When hanging this fixture, always secure it to a fastening device using a safety cable (not provided).| | Use cleaning tissue to remove the dust absorbed on the extemal lenses peniodically to optimize light output.
| Don’t throw this product away just as general trash. please dispose of this product following the abandon electromec product regulation m your country.|
| To protect the environment, recycle packing material wherever possible.

Laser Safty Warnings

Potential laser injury hazard exists with this product! Read these Instructions carefully, which include important information about installation, safe use and service!

Caution

  • Avoid direct eye contact with laser light. Never intentionally expose your eyes or others to direct laser radiation.
  • This laser product can potentially cause instant eye injury or blindness if laser light directly strikes the eyes.
  • It s illegal and dangerous to shine this laser into audience areas, where the audience or other personnel could get direct laser beams or bright reflections into their eyes.
  • Itis a US Federal offense to shine any laser at aircraft.

NON-INTERLOCKED HOUSING WARNING
*This unit contains high power laser devices internally. Do not open the laser housing, due to potential exposure to unsafe levels of laser radiation. The laser power levels accessible if the unit is opened can cause instant blindness, skin burns and fires.

Installation

U King RGBY Four Tunnels Laser Show System - parts1Laser effects projected 3 meters (9.8 ft) above the audience are eye safe. A survey should be taken to assess the likelihood of any reflective surfaces (such as high windows, chrome bars etc) bouncing stray beams back down into the audience
Using a fastening clamps on the light and tight to the ceiling in a strong hook.
*Make sure its correct power output and plug the power cable to the wall socket.

  • Power must be in earth! Power on the light.
  • Do not shoot the beams to the audience!
    *Do not look direct into the laser aperture once the laser light is ON. Please pay attention to the Laser Danger Warning Label!

Cleaning

Fixture Cleaning: Due to fog residue, smoke, and dust cleaning the internal and external Ienses should be carried out periodically to optimize light output.

  1. Use normal glass cleaner and a soft cloth to wipe down the out- side casing.
  2. Clean the extenal optics with glass cleaner and a soft cloth every 20 days.
  3. Always be sure to dry all parts completely before plugging the unit back in.

Cleaning frequency depends on the environment in which the fixture operates (L. smoke, fog residue, dust, dew). In heavy use we recommend cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp beam output.

Front/Rear Panel

U King RGBY Four Tunnels Laser Show System - parts2

Function & Setting

SoundWAT tive POWER POWER POWER POWER PO The change of the laser paternis controlled by sound’ thatis,, the thythm of the sound control the effect of the changing laser pattern. Tuming the sensitivity knob in the clockwise direction to increase the fixture’s sensitivity to sound, the knob in the counter clockwise direction to decrease. The laser diode will automatically tum off after 8 seconds when the music stops.
AUTO
Auto cycles the built-in programs without being controlled extemally. It has no laser OFF.
The mode allows a single unit to react to the beat of the music in the master mode.

  1. Install the units in a suitable pos iOti o (laying or append ing)ER POWER
  2. Set dipswiteh to select Sound Active or AUTO mode.
  3. Tum on the unit power, the unit begins reset, then the unit begins working.
  4. The unit will react to the low frequencies of music via the internal microphone.

Adjust the audio sensitivity knob on the back of the unit to makWtEhe unit more or less sensitive in sound active.The panel has LED indicating for sound active.
Master- Slave Operation
This mode will allow you to link up to 32 units together without controller.

  1. Install the units in a suitable position (laying or appending).

  2. Choose a unit to function as Master mode, set dipswitch to select Sound Active or
    AUTOmode. The others mOustEbRe set to Slave mode, seiWdipR switch to select SlaveP mode.

  3. Use standard XLR microphone cable chain your units together via the XLR connector POWER on the rear of the units. For longer cable runs we suggest a terminator at the last fixture.
    Cabling must have a male XLR connector on one end and a female XLR connector on the other end.U King RGBY Four Tunnels Laser Show System -
parts3Uses dipswitches to assign a unit’s function: DMXslave, or sound active, or AUTO mode.
    Grounding the common can cause a ground loop, and your fixture may perform erratically.
    Test cables with an olum meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shild or each other.

  4. Tumn on the all units’ power, the units begins reset, then the unit begins working. The slave units will react the same as the master unit.

  5. The units will react to the low frequencies of music via the internal microphone.
    Adjust the audio sensitivity knob on the back of the master unit to make the unit more or less sensitive in sound active. The panel has LED indicating for sound active.

Universal DMX Operation (DMX mode)
This mode allows you to use universal DMX-512 console to operate.

  1. Install the units in a suitable position (laying or appending).

  2. Use standard XLR microphone cable chain your units together via the XLR connector on the rear of the units. For longer cable runs we suggest a terminator at the last fixture.

  3. Assign a DMX address to each the unit using dipswitches, see the “DMX Address Quick Reference Char”.U King RGBY Four Tunnels Laser Show System - parts4DMX Signal
    1 : MASTER: SOUND/AUTODMX 2: SLAVE 2: SLAVE

  4. Turnon the all units’ po we 1E, T he units begins reset,Pthe nET he unit begins workinPg.

  5. Use DMX console to control your units.

Notes:

  1. DMX console can not be used in Master-Slave operation (Sound Active or AUTO mode )
  2. There should be only one master unit in Master-Slave operation.

DMX Control
The system only accepts the DMX512 signal of international standard to control the system mode, the laser beam ON /OFF, running direction, running speed and twinkle speed ec. represents a binary value. See the “Function chart” .
DMX Chart 1=ON 0=OFF x=ON OR OFF

Dipswitch Mode
1 2
0 x
0 x
x x
Dipswitch 0

DMX address calculation
For DMX mode, DMX address from #1 to 9# dipswitches must be set, the address is set from 1 to 511. Each dipswitch represents a binary value.

Dipswitch Value Dipswitch Value
#1 1 #6 32
#2 2 #7 64
#3 4 #8 128
#4 8 #9 256
#5 16 #10 DMX, Set to “0”

One unit has 5 channels, so each unit must be assigns 5 channels at least. We may assign 8 channels for one unit, then DMX address = 8*N+ 1, N=0,1, 2,3 …… Example, One loop address=1, two loop address=0, three loop address=17, four loop address=25

Loop Address Binary Dipswitches
1 1 100000000 #1
2 9 100100000 #1+#4
3 17 100010000 #1+#5
4 25 100110000 #1+#4+#5

The dipswitches setting for DMX address see the ” DMX Address Quick Reference Chart “.
DMX Control
The system only accepts the DMXS512 signal of international standard to control the system
DMX Control Parameter Chart

Channel Function POValue POWED Rescription
CHI Mode 0—-63 Close, laser OFF
P064E-127P Sound active
128— 191 AUTO
192-255 DMX
CH2 Pattern selecti oOnW 0—2P505W E2R8 stag c/dynaPlliNicEpRattems
CH3 Position-X 0—-24 Manual Adjust position- X
POW25—87 AUTO Movement from Left to Right
88— 151 AUTO Movement from right to left
152—215 AUTO movement Left/ Right
216—231 Sound Active movement from left to right
232—239 Sound Active movement from right to left
p2417—255 Sound Active left/right
CH4 PO Position-Y 0—-24 Manual Adjust position- Y
25—87 AUTO movement from up to down
N 88— 151 AUFTO movethOe fit& rom down to up
152— 183 AUTO movement up/down
184— 191 Sound Active movement from up to down
192—207 Sound Active movement from down to up
207—215 Sound Active movement up/ down
216—247 AUTO jumping
248—255 Sound Active jumping
CH5 Patten size
Zoom(+/-) 0 No movement
1—63 Manual zoom(+/-)
64–95 Auto zoom(+)
96— 127 Auto zoom(-)
128— 159 Auto zoom(+/-)
160– 191 Sound Active zoom(+)
192—223 Sound Active zoom(-)
224—255 Sound Activ zoom(+/-)
CI 16 Dimmer-X 0— 128 Munual dimmer
--- --- --- ---
129—223 AUTO dimmer
224—255 Sound Active dimmer
C1-17 Dimmer-Y 0– 128 Munual dimmer
129—223 AUTO dimmer
224—255 Sound Active dimmer
CH8 Rotation 0 No rotation
1–71 Manual rotation
72– 135 Auto clockwise rotation
136— 199 Auto counter clockwise rotation
200—231 Sound Active clockwise rotation
232—255 Sound Active counter clockwise rotation
CH9 Output lens
selection 0–55 Manual selection (ABCD-A-B-C-D-AC-BDAB- CD-RD-BC-ABC- CBD-

ACD-ABD-
55—87| Au TO) change A– B- – C- – D
88— 119| AUTO change D—C—B– A
120— 151| AUTO change AC–BD–AB–CD–RD–BC
152– 183| AUTO change ABC–CBD–ACD–ABD
184– 199| AUTO change A– AB– ABC– ABCD
200—215| AUTO change D–CD–BCD–ABCD
216—223| Sound Active change A–B–C–D
224—231| Sound Active change D–C–B–A
232–239| Sound Active change AC–BD–AB–CD–RD–
240–247| Sound Active change ABC– CBD– ACD–ABD
248—251| Sound Active change A– AB–ABC– ABCD
252—255| Sound Active change D– CD– BCD–ABCD
CH10| Phase-X| 0—63| No phase
64– 127| AB and CD phase, oposite position
128– 191| AC and BD phase, oposite position
192–255| AD and BC phase, oposite position
CH11| Phase-Y| 0—63| No phase
64— 127| AB and CD phase, oposite position
128– 191| AC and BD phase, oposite position
192–255| AD and BC phase, oposite position

Caution: Do not allow contact between the common and the ficture’s chassis ground.

Troubleshooting

  1. If the power supply indicator doesn’t light up and the laser doesn’t work, please check the power supply, the input voltage and the fuse.

  2. In Stand-Alone operation, if the power supply indicator is light up and sound active indicator isn’t light up, but the laser is shut off doesn’t work.
    A. Because sound is too small make for laser shut off in sound active, please increase the music volume or increase audio sensitivity with sensitivity knob, please check as below.
    B. Please check if unit has been set up in slave mode, then set up in master mode.

  3. In Master-Slave operation, slave unit don’t function, please check as below.
    A Make sure to there’s only one master in the chain, and the others are set in slave mode.
    B. Make sure to control the unit without DMX console controlling.
    €. Make sure to take a good quality power cable and connection.

  4. In DMX mode operation, the laser is OFF and the DMX signal indicator is unlighted, please check as below.
    A. Make sure to set up the DMX mode.
    B. Make sure to have a good connection.

  5. Tn DMX operation, the unit can’t be controlled by the DMX console, but the DMX signal indicator is flashing, please make sure the DMX console and unit have the same channel.

  6. If the unit is fail, please turn off the unit, then turn on again after 5 minutes.

Warranty Warnings:

  1. Damages caused by the distegard of this user manual are not subject to Warranty.
  2. Please consider that unauthorized modifications on the device are forbidden due to safety reasons. Please note that damages caused by manual modifications on the device or unauthorized operation by unqualified persons are not subject to warranty.
  3. If this device will be operated in any way different to the one described in this manual, it may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burms electric shock, etc.

After trying the above solution you still have a problem, please contact your dealer or our company for service.

DMXAddress Chart

This chart lists the DMX dipswitch setting for DMX address 1 through 511. Follow the instructions below to configure fixture dipswitches with you desired DMX address.
DMX Address Quick Reference Chart![U King RGBY Four Tunnels Laser Show System

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals