CARRO LCFR523F3-L11-WM1-FM Lainey 52 in White Integrated LED Indoor Ceiling Fan Instruction Manual

June 16, 2024
CARRO

CARRO LCFR523F3-L11-WM1-FM Lainey 52 in White Integrated LED Indoor

Ceiling Fan

CARRO-LCFR523F3-L11-WM1-FM-Lainey-52-in-White-Integrated-LED-Indoor-Ceiling-
Fan-product

This Carro Ceiling Fan has

CARRO-LCFR523F3-L11-WM1-FM-Lainey-52-in-White-Integrated-LED-Indoor-Ceiling-
Fan-fig-1

SAFETY PRECAUTIONS

  • Before you begin installing the fan, shut the power off at the circuit breaker of the fuse box.

  • Make sure that all electrical connections are under the National Electrical Code, ANSI/NFPA 70 and local codes. Hire a licensed electrician if you are unfamiliar with installing electrical wiring.

  • Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 2.1 m (7 feet) from the floor and 18 inches from the tip of the blades to the wall.

  • The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 pounds. Use only U.L. listed outlet boxes marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or less”.

  • Before and after you install the fan, make sure that all mounting components are secured to prevent the fan from falling.

  • Do not insert anything into the fan blades while the fan is operating.

  • To change the direction of the rotation of the blades, the fan must be in operation mode.

  • All screws must be checked and retightened where necessary before installation.

  • After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.

  • The splices after being made should be turned upward and pushed carefully up into the outlet box. Conductor wiring identified as grounded is to be connected to a grounded conductor of power supply. Conductor wiring identified as an ungrounded conductor is to be connected to an ungrounded conductor. Conductor wiring identified for equipment grounding is to be connected to an equipment-grounding conductor.

  • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

  • CAUTION: Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

  • WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked ”Acceptable for Fan Support of 15.9 kg (35 lbs) or less” and use mounting screws provided with the outlet box.

  • CAUTION: To reduce the risk of injury, use only the screws provided with the outlet box
    in conjunction with the lock washers.

  • WARNING: To reduce the risk of personal injury, do not bend the blade bracket when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

  • CAUTION: To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing the light kit.

  • WARNING: To reduce the risk of fire or electric shock, this fan must be installed with a general use, non-dimmable, single gang, isolating wall control/switch.

  • WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid­state speed control device.
    NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which cannot be built into this product. These factors must be supplied by the person (s) installing, caring for and operating the unit.

  • CAUTION: The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the product should be returned to an authorized service facility for examination or repair.

  • WARNING: Do not use corrosive detergents for cleaning.

Fan Diagram

CARRO-LCFR523F3-L11-WM1-FM-Lainey-52-in-White-Integrated-LED-Indoor-Ceiling-
Fan-fig-2

Installation

WARNING: To avoid serious injury or death, turn off the power at the circuit breaker before installing the fan.

Tools you’ll need

Install the Fan Blades

  1. Locate 6 blade attachment screws and washers included in the hardware pack. Use these screws and washers to firmly attach each blade to the motor hub, as demonstrated in Fig. 1.1.
  2. Follow the same procedure for the remaining blades, making sure all screws are tightly secured to ensure a stable installation.

Install the Light Kit Pan & Light Kit

  1. Remove the light assembly from the packaging, and detach the LED light kit from the light kit pan directly, as it is held in place by magnets as shown in Fig. 2.1.

  2. Unscrew one light kit assembly screw from the motor plate and loosen the remaining two screws.
    Thread the wire plug from the motor and the safety rope through the center hole of the light kit pan. Align and secure the light kit pan to the motor plate, ensuring the heads of the two loosened screws fit into the keyhole slots. Rotate the light kit pan until the screws move into the narrow ends of the keyhole slots as shown in Fig. 2.2.
    Once aligned, tighten all the screws securely, and then reinstall the light kit assembly screw that was removed earlier. Make sure that all screws are tightened securely for stability.

  3. Let the wire plug pass through the light kit. Reattach the light kit. The light kit will be magnetically attracted to the pan with the help of magnets.

  4. Connect the wire plug to the terminal block of the light kit as shown in Fig. 2.4. ****

Mounting Options

Install the Mounting Plate
Carefully flip the fan over. Loosen the canopy screws and remove the mounting plate. Save the screws for later use as shown in Fig. 3.1.

You have two options for the mounting plate installation. Choose the one that works best for your location.

Hanging

WARNING: Before beginning, make sure to turn off the power from the breaker circuit!
Note: For optimal fan performance, ensure that the mounting plate is level.

  • Option 1 : Secure the mounting plate to a wooden ceiling beam or support structure with an approved electrical outlet box using the ST5x24mm wood screws (included) as shown
    in Fig. 3.2.

  • Option 2: Use machine screws (provided with outlet box) and washers to attach the mounting plate to an existing ceiling fan-rated outlet box. If the mounting plate is installed at the outlet box, it should be installed on the outlet box with the screws that came with your outlet box. Pull the supply wires (the black, white, and ground wires) out of the outlet box and through the hole in the mounting plate, then set them aside.

WARNING: DO NOT use a plastic outlet box. Use only U.L. listed outlet boxes marked ”Acceptable for Fan Support of 15.9 kg (35 lbs) or less”.

Hang the Fan
Carefully lift the fan-motor assembly and hang it using the hook of the mounting plate. Securely suspend the motor assembly by using one of the round holes at the outer rim of the motor housing as shown in Fig. 4.1.

Safety Rope
There are multiple methods to install the safety rope; here are two options for your reference.

  • Option 1: Refer to Fig. 4.2. Hang the safety rope on the ceiling hook (not included). Using a screwdriver, loosen the screw on the safety rope lock. Pull the safety rope taut and then tighten the screw on the safety rope lock to ensure a firm and secure connection between the safety rope and the ceiling hook. Always double-check to ensure the safety rope is taut.
  • Option 2: Refer to Fig. 4.3. Thread a screw, accompanied by a washer
    (both not included), through the centre of the safety rope. Fasten the screw to the ceiling and then loosen the screw on the safety rope lock using a screwdriver. Pull the safety rope taut and then tighten the screw on the safety rope lock to securely anchor the safety rope to the fixed screw on the ceiling. Always double­check to ensure the safety rope is taut.

Note: Installing the ceiling fan with a safety rope is an extra safety feature. It secures the fan to the ceiling hook or other attachment point and prevents the fan from falling even in the case of material failure.
When the safety rope is fixed and installed, it is important to adjust both the length of the wire rope and the screw on the safety rope lock to ensure a secure and tight connection with the fixed object.This step is crucial to prevent the safety rope from accidentally coming off. Improper installation of the safety rope may compromise its effectiveness and lead to potential safety risks. Therefore, it is essential to make sure the safety rope is properly tightened and secured for maximum safety.

Wiring

  • Connect the Wiring

    • Connect the Green/Yellow wire from the mounting plate to the supply Ground wire using a wire nut.
    • Connect the White wire from the motor to the supply White (Neutral) wire using a wire nut. Connect the Black wire from the motor to the supply Black/Red (Hot/Live) wire using a wire nut.
    • Make sure all the wires are connected to the correct colors as shown in Fig. 5.1. Then, hide the wiring inside the motor housing.

Securing the Fan

  • Reinstall two of the four canopy screws onto the mounting plate (located on opposite sides), but do not fully tighten them yet.
  • With both hands, lift the fan body off of the hook. Ensure that the hook does not interfere with the wires and align the two key slots on top of the motor assembly with the two loosened screws on the mounting plate.
  • Push the fan motor assembly up and twist it to lock onto the mounting plate. Tighten the two screws. Then, reinstall the other two screws into the remaining two holes and tighten all four screws firmly.

WARNING: Falling fan hazard!
Make sure all screws are tightened securely to hold the fan motor assembly in place.

Lampshade/ Power On

  • Install the Lampshade
    Align the slots of the lampshade with the slots of the light kit pan, and turn the lampshade clockwise to securely lock it into place, as shown in Fig. 7 .1.
    Note : Do not over tighten the lampshade.

WARNING: To prevent SERIOUS INJURY or DEATH, make sure that the lampshade is properly secured. Allow the lampshade to cool completely before attempting to remove it.

Power On
At this time, the ceiling fan has been installed. Turn on the power supply from the breaker circuit of the main switch or the room where the ceiling fan is installed. Once the power is on, check to see if the fan light is illuminated and pair the fan with the remote immediately.

Remote Control Instructions

Pair the Remote Control to Your Fan
Power on the fan and pair the remote to the fan within 1 minute. To pair the remote to the fan, press and hold the button for 3-5 secs to pair. Successful pairing will trigger the fan light off.

Remote Control Button Definition s

  • Turn the fan off.
  • Switch between summer mode and winter mode.
    • Summer mode – (Counter-clockwise)
    • Winter mode – (Clockwise )
  • Turn the fan on and decrease the fan speed.
  • Turn the fan on and increase the fan speed. ON
  • Switch the fan speed between nature mode and normal mode. Simulate a natural breeze, gentle enough not to disturb you while you sleep.
  • Turn the light on or off and remote pairing.
  • Note: Power on the fan and pair the remote to the fan within 1 minute. To pair the remote to the fan, press and hold the button for 3-5 secs to pair. Successful pairing will trigger the fan light off.
  • Switch between warm light and cool light.
  • Press/Hold the button to decrease the light intensity.
  • Press/Hold to button to increase the light intensity.

WARNING : Do not expose the remote control to direct contact with water.

Troubleshooting

Try these troubleshooting steps before contacting Customer Service. For additional operation, maintenance, and troubleshooting information, please contact our customer service centre.

CARRO-LCFR523F3-L11-WM1-FM-Lainey-52-in-White-Integrated-LED-Indoor-Ceiling-
Fan-fig-28

Care & Cleaning

  1. Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure. Because of the fan’s natural movement, some connections may become loose over time. It is not necessary to remove the fan from the ceiling.
  2. Clean your fan periodically. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer to minimize discoloration or tarnishing.
  3. (Optional) Apply a light coat of furniture polish to the wood blades.
  4. (Optional) Cover small scratches with a light application of shoe polish.

DO NOT:

  1. Use water when cleaning. Water could damage the motor, or the wood, or possibly cause an electrical shock.
  2. Apply oil to your fan or motor. The motor has permanently lubricated sealed ball bearings. WARNING: Power off the fan before performing maintenance or cleaning the fan.

FCC Statement

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Important: Please read and save these instructions before installation

Basic Product Specifications

CARRO-LCFR523F3-L11-WM1-FM-Lainey-52-in-White-Integrated-LED-Indoor-Ceiling-
Fan-fig-29

U.S. Patent Nos.: 10,511,206 and 11,296,561. Other Patent(s) Pending.

Questions
Have questions about our products? Contact us and talk to our helpful tech support team.

Technical Support

  • Business Hours:
  • Monday – Friday (Holidays observed).
  • 9:00 am to 5:30 pm PST.
  • Tel: 888-253-2374

The product images shown in the manual are for reference purposes only. Actual product may differ slightly.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CARRO User Manuals

Related Manuals