robustel EV8100 Elevator Voice Gateway User Manual

June 16, 2024
robustel

robustel EV8100 Elevator Voice Gateway User Manual

Regulatory and Type Approval Information

Table 1: Toxic or Hazardous Substances or Elements with Defined Concentration Limits

Name of the Part Hazardous Substances
(Pb) (Hg)

Metal

parts

| X| o| o| o| –| –| –| –| –| –
Circuit

modules

| o| o| o| o| o| o| o| o| o| o
Cables and cable

assemblies

|

o

|

o

|

o

|

o

|

o

|

o

|

o

|

o

|

o

|

o

Plastic and

polymeric parts

|

o

|

o

|

o

|

o

|

o

|

o

|

o

|

o

|

o

|

o

o:

Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in RoHS2.0.

X:

Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part might exceed the limit requirement in RoHS2.0.

-:

Indicates that it does not contain the toxic or hazardous substance.

Radio Specifications for Europe

RF technologies 2G, 3G, 4G, GNSS, Wi-Fi, BLE*
Cellular Frequency 4G : LTE FDD:

B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28 LTE TDD: B38/B39/B40/B41

3G : WCDMA: B1/B2/B4/B5/B6/B8/B19

2G : GSM: B2/B3/B5/B8

Wi-Fi Frequency*| 2.4 GHz: 2.412 ~ 2.484 GHz

5 GHz: 5.18 ~ 5.825 GHz

BLE Frequency*| 2402 ~ 2480 MHz
Max RF power| 33 dBm±2dB@GSM, 24 dBm+1/-3dB@WCDMA, 23 dBm±2dB@LTE, 17 dBm ±2 dB

@2.4GHz Wi-Fi, 13 dBm ±2 dB@5GHz Wi-Fi, 4 dBm@BLE

May vary on difference models.

Note: The 5150 to 5350 MHz frequency range is restricted to indoor use only in.
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s) and Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause
  • This device must accept any interference, including interference that may cause undesired operation of the

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :

  • L’appareil ne doit pas produire de brouillage;
  • L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.

FCC& IC Radiation Exposure Statement

This equipment complies with FCC and Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Déclaration d’IC sur l’exposition aux radiations

Cet équipement est conforme aux limites d’exposition aux radiations définies par le Canada pour des environnements non contrôlés. Cet équipement doit être installé et utilisé à une distance minimum de 20 cm entre l’antenne et votre corps.
Cet émetteur ne doit pas être installé au même endroit ni utilisé avec une autre antenne ou un autre émetteur.

Simplified EU & UK Declaration of Conformity

We, Guangzhou Robustel Co., Ltd. are located at 501, Building #2, 63 Yongan Road, Huangpu District, Guangzhou, China, declare that this radio equipment complies with EU Radio Equipment Directive (RED)  2014/53/EU, Low Voltage Directive (LVD) 2014/35/EU, EMC Directive 2014/30/EU, UK Radio Equipment Regulations 2017, EMC Regulations 2016, Electrical Equipment(Safety) Regulations 2016. The full text of the EU& UK DoC is available at the following internet address:.robustel.com/certifications/

Safety Information General

  • The router generates radio frequency (RF) When using the router, care must be taken on safety issues related to RF interference as well as regulations of RF equipment.
  • Do not use your router in aircraft, hospitals, petrol stations or in places where using cellular products is
  • Be sure that the router will not be interfering with nearby equipment. For example: pacemakers or medical equipment. The antenna of the router should be away from computers, office equipment, home appliance,
  • An external antenna must be connected to the router for proper Only uses approved antenna with the router. Please contact authorized distributor on finding an approved antenna.

RF Exposure

  • This device meets the official requirements for exposure to radio This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by authorized agencies.
  • The device must be used with a minimum separation of 20 cm from a person’s body to ensure compliance with RF exposure Failure to observe these instructions could result in your RF exposure exceeding the applicable limits.

Note: Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door is open. Router may be used at this time.

The symbol indicates that the product should not be mixed with general household waste but must be sent to separate collection facilities for recovery and recycling.
The symbol indicates that the product meets the requirements of the applicable EU directives.
The symbol indicates that the product meets the requirements of the relevant UK legislation.

Find more product documents or tools at: www.robustel.com/documentation/

Technical Support

Tel: +86-20-82321505
Email: [email protected] Web: www.robustel.com

Document History

Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions.

Date| Firmware Version| Document Version| Change Description
---|---|---|---
Oct. 18, 2023| 2.1.1.3| 1.0.0| Initial release.
| | |
| | |

Overview

EV8100 is an advanced elevator voice gateway that supports voice transmission over VoIP and VoLTE, enabling seamless communication between a cellular network and the elevator’s intercom system, with latest Linux Debian bullseye based router OS with enhanced cybersecurity, advanced GUI and a myriad of software features.

Package Checklist

Before commencing installation ensure your package has the following components:

Note: The accessories could be different on specific order

Panel Layout

Interface Descriptions

  1. Serial
Name Description
CANL For transmitting low-level signals
CANH For transmitting high-level signals
GND Ground
Name RS232 Mode
TXD/A data sending
RXD/B data receiving
GND Ground
  1. Ethernet Two Ethernet ports, both of them could be configured as WAN or LAN.
LED Description
Activity On, blinking
Off No activity
Link Off
On Link on
  1. Reset
Function Operation
Reboot Press and hold the RST button for 2~5 seconds under the operating

status.
Restore to default configuration| Press and hold the RST button for 5 ~10 seconds under the operating status.

The RUN light flashes quickly, and then release the RST button,

and the device will restore to the

default configuration.

Restore to factory configuration| Once the operation of restoring the default configuration is performed twice within one minute, the device will restore to the factory default settings.

Digital Input and Relay Outpurt.

Four sets of digital inputs and a set of relay output

Name Type Description
DI1+ ****



Digital I/O

| Digital Input positive
DI1-| Digital Input negative
DI2+| Digital Input positive
DI2-| Digital Input negative
DI3+| Digital Input positive
DI3-| Digital Input negative
DI4+| Digital Input positive
DI4-| Digital Input negative
NC| ****

Relay Output

| Normally Closed
COM| Common
NO| Normally Open

  • Digital Input and Relay Four sets of digital inputs and a set of relay output.

Note: When the relay is off, NC is connected to COM, and NO is disconnected. The external power supply input voltage range is DC 5-48V, with a maximum load current of 300mA.

  1. LED
LED Description


RUN

| On, solid| Gateway system is initializing
On,blinking| Gateway starts operating
Off| Gateway is powered off
Note: The RUN LED’s color is green



Line

| Color| SIP: Green, VoLTE: Yellow,

Other: Red

On| In a call
On,blinking| On-hook
Off| Dialing/Incoming call


MDM

| Color| 2G: Red, 3G: Yellow, 4G: Green
On, blinking| Link connection is working
Off| Link connection is not working
****| Green| Strong signal
Yellow| Medium signal
Red| Weak or no signal


Cloud

| On, solid| Connected successfully
On,blinking| In communication
Off| Disconnected


Device

| On, solid| Connected successfully
On,blinking| In communication
Off| Disconnected




Battery

| On| Powered by Battery



On,blinking

| 1.   Battery Powered:

Low battery level

2.   AC Powered:

Battery malfunction or Battery anomaly

Off| Non-battery power supply

  1. FXS
Name Description
TIP Connect to the RING lead of the subscriber loop.
RING Connect to the TlP lead of the subscriber loop。

Lithium-ion Battery Instructions

  1. Device is only compatible with 18650 lithium
  2. If using a single battery, install it in position
  3. Improper installation or use of incorrect batteries may damage the device and void

Hardware Installation

  1. SIM Card Installation. Insert the SIM cards into the device and paste SIM card cover sticker if

  2. Antenna Installation. Rotate the antenna into the antenna connector accordingly.

  3. Terminal Block Insert the 2x3PIN and 2x4PIN terminal blocks into the interfaces connector, then can connect the devices or sensors to the gateway with wires via corresponding interfaces e.g. RS232, RS485, DIDO, CAN,FXS…

  4. Power Supply installation. Insert the power supply cord into the corresponding terminal block if needed, then insert the terminal block into the power connector.

  5. DIN Rail Use 2 M3 screws to fix the DIN rail to the device, then hang the DIN rail on the mounting bracket.

  6. Wall Mounting. Use 4 M3 screws to fix the Wall mounting to the device

  7. Magnetic Use 4 magnet buttons to attach in the corresponding positions behind the device with screws.

Login to the Device

  1. Connect the gateway’s Ethernet port to a PC with a standard Ethernet cable.

  2. Before logging in, manually configure the PC with a static IP address on the same subnet as the gateway address, click and configure “Use the following IP address”.

  3. To enter the gateway’s web interface, type http://192.168.0.1 into the URL field of your Internet browser.

  4. Use login information shown in the product label when prompted for authentication.

  5. After logging in, the home page of the web interface is displayed, then you can view system information and perform configuration on the

  6. The automatic APN selection is ON by default, if need to specify your own APN, please go to the menu Interface- >Cellular->Advanced Cellular Setting->General Settings to finish the specific