CMS Electracom FR001 Freedom Portable USB Charger Instruction Manual
- June 16, 2024
- CMS Electracom
Table of Contents
CMS Electracom FR001 Freedom Portable USB Charger
IMPORTANT SAFETY INSTRUCTIONS WARNING
This symbol indicates information concerning your personal safety.
CAUTION This symbol indicates information on how to avoid damaging the unit.
IMPORTANT This symbol indicats tips and information about seting up FR002 (Charging Base).
CAUTION / WARNING
- Do not exposed to water.
- This unit may become hot when recharging, handle with care.
- Do not leave in hot conditions 60C or above e.g., left sitting in hot car.
- Do not operate unit outside of specified conditions.
- This unit contains Li-ion 18650 or equivalent cells.
- Do not expose to heat or throw in fire.
- Do not attempt to modify.
- Be careful when unpackaging the unit. Do not use sharp objects when removing the packaging as this may cause scratches to the unit.
Specification
- Model: FR001
- Battery cells : Li-ion 18650
- Battery Capacity: 18900mAh*(+/- 5%)
- Input (Power in contacts ): DC 20V/1.5A (max)
- Type-C output: DC 5V/3A, 9V/3A, 15V/3A, 20V/3A (PD3.0 60W)
- Type-A output: DC 5V/3A, 9V/2A, 12V/1.5A (QC3.0 18W)
- Total output : 78W (Both ports combined)
- Dimensions : 136mm diameter x 33mm tall
- Weight: 0.46KG
- Operation Temperature : 5~35C
- Packaging Content: 1 x FR001 Specification FR002
- Model : FR002
- Power Input : 20V/7.5A
- Power output : 20V/7.5A
- Dimensions : 145mm diameter x 21.5mm tall
- Weight : 0.34KG
Packaging content : 1 x FR002, 1 x AC Power Cord, 1 x Power Supply (20V/7.5A)
Product Overview – FR001
-
Reset button location
-
USB C Port
-
USB A Port
-
Power Button
-
LED Charge level indicator
-
Power Contact Rings
-
Power Out Contact Rings
-
Power Indicator
-
D.C. Jack – Power In
-
Available with optional fixing brackets as shown.
Setting Up FR002
- Plug the AC cord into the power supply.
- Plug the AC plug into an outlet.
- Plug the power out lead from the power supply into the DC jack on at the back of FR002. Power indicator will illuminate green.
IMPORTANT – Fixing Bracket
- Take the fixing bracket and 2x screws out of the packet. a)
- Align the fixing bracket with the 2 screw holes as shown above and screw into place.
- You can use any screw of your choosing that fit a 4mm hole to fix the charging base in place.
Setting Up & Recharging FR001
Setting up IMPORTANT
To recharge the power bank, place it onto the dedicated charging base (FR002).
The power bank will be recharged via the contact pins on the base of each
unit. Multiple power banks can be stacked on top of one another when
recharging.
The dedicated charge base (FR002) can support 5 units with recharge times
around 3.3 hours, or 5 plus units at extended recharge times.
A white LED will flash to indicate the power bank is recharging. As the unit charges the additional LED(s) will remain on until all four LEDs are on constantly.
Using the Power Bank
FR001 can recharge any USB C or USB A compatible device(s). Simply plug in the device and press the power button on freedom to turn it on. Four white LEDs will illuminate.
As FR001 discharges your device each LED will go out systematically until the unit is depleted.
User Maintenance
Instructions
Important – Cleaning
When cleaning FR001 do not spray cleaner directly onto unit. Spray onto cloth and wipe down the unit. Only spray enough cleaner that the cloth is just damp to the touch. When cleaning FR002 disconnect from mains power before wi ping down. Do not spray cleaner directly onto the unit. Spray onto a cloth and wipe down the unit. Only spray enough cleaner that the cloth is just damp to the touch.
User Do’s & Don’ts
- Don’t expose to water or high humidity environment.
- Don’t leave outdoors or be exposed to weather.
- Don’t leave sitting in or exposed to direct sunlight.
- Don’t operate in the hot environment exceeding product operating range.
- Do allow time for FR001 to cool down before recharging if a large load has been applied to the unit (rapidly discharging) to maintain the battery health.
Moving & Storage
Instructions
& CAUTION – Storage Temperature
- As FR001 contain Lithium-ion batteries; exposure to extreme temperatures, both high and low, can negatively impact their performance and compromise their safety. High temperatures accelerate the aging process and can cause thermal instability, leading to thermal runaway. Freezing temperatures can cause irreversible damage to the battery’s chemistry, reducing its capacity and overall lifespan.
- Therefore, storing the Power Bank(s) in a cool and dry environment, away from direct sunlight and heat sources, is vital to maintain their integrity and performance.
- Try to store them at a temperature range of between (10~30 ) and humidity of (30~ 70%).
CAUTION – Physical Damage
Avoid physical damage or stress to the Power Bank(s). Crushing or puncturing the Power Bank(s) can result in internal short circuits, leading to thermal runaway. Store in a safe location away from any risk of being crushed or punctured.
IMPORTANT- Long Term Storage
& Maintaining Battery Health Maintaining an appropriate state of charge during storage is crucial to maintaining battery health. When left in storage the power bank{s) will have a small discharge rate of 0.25mA, over time this will deplete the power bank(s).
Discharge Rate :
- Total Capacity: 3000mAh
- PCB Self-discharge current : 0.25mA MAX As a result, the power bank(s) MUST be recharged every 6 months to maintain cell health.
Disposal of Product
CAUTION
This product contains Lithium-Iron batteries, Do not dispose of FR001 in general waste.
CMS guarantees to receive these batteries back at the end of its in-use phase for recycling. The service is free and the used batteries need to be delivered by the client to our CMS offices. Otherwise at the end of the product life cycle the freedom unit must be disposed off at an appropriate waste facility.
Troubleshooting
Issue | Cause | Solution |
---|---|---|
All four LEDs flashing simultaneous | The over-current protection is activated | |
during discharging. | Remove the over-loading device | |
The over-temperature protection is activated during charging. | The Unit |
stopped charging as the device operating temperature has been exceeded. The
unit will resume function after returning to operating temperature range.
The power bank cannot be charged.| The firmware is shutdown.| press the reset
button.
Contact pins are not making good contact with the charging plates.| Check that
no debris is impeding recharging via the contact rings/pins and try again
your plugged-in device(s) are not charging.| There is no capacity left.| Re-
charge the power bank.
The firmware is shutdown.| Press the reset button.
The power bank isn’t turned on.| Press the power button
The connection cable is not good.| Make sure the cable is in good condition
and undamaged. You may need to try with another cable.
Unit run time is low| The capacity left is low| Re-charge the power bank.
The working current of devices is larger.| Battery degradation over time/usage
Battery is close to end of life| Battery degradation over time/usage
Unit is Unresponsive| The Unit software is frozen/unresponsive| Press and hold
RESET button for 10 seconds (Rest Button located on the underside of the
unit).
Read User Manual Online (PDF format)