TBL-DES CONCENTRATED Hot Air Gun Instruction Manual

June 10, 2024
TBL-DES

TBL-DES CONCENTRATED Hot Air Gun

Thank you for using this product. Please read the instructions carefully before use to avoid errors in operation.

Remark:
The “warning” and “note” in the specification are defined as follows:

Warning : abuse shall result in death or serious injury.

Note : abuse shall result in damage to the users or the objects

PRODUCT MODEL

PACKING LIST

  • Mainframe ……………………………………………. 1
  • FP Pick-up …………………………………………… 1
  • FP Pick-up wire (L) …………………………………….. 1
  • FP Pick-up wire (S) ……………………………………… 1
  • Spurt-tip NS05 ……………………………………….. 1
  • Spurt-tip NS08 ……………………………………….. 1
  • Instruction manual. ……………………………………… 1
  • Guaranty card ………………………………………….. 1
  • Qualified certificate ………………………………………. 1

FEATURES

  • Small volume. saving working space with the new design.
  • It is new vortex design for exit, decreasing anomaly temperature.
  • Small body volume, saving working space, portable handle domiation, saving working time.
  • Adjustable air volume & temperature, adapting to de-soldering chips of QFP, SOP, PLCC, &SOJ.
  • Setting cooling function; turning offthe power, the system continues sending cool air until the temperature is lower down to 80°C, protecting the elements from high temperature damage.
  • Inside temperature sensor setting, ensuring stable temperature for different air volume.
  • Static elimination design that is safe for sensitive elements.

SPECIFICATIONS

  • Name DES 560B I DES 560C
  • Display Digital display I Digital display
  • Power consumption 560W
  • Temperature Range 80~600°C
  • Air-volume Level 1~8
  • DC turbine fan 12V/8500 Rotation
  • High temperature set of head GP5/GP6 (Purchase additionally)
  • Exothermic material oAC11 0V(A 1525B) o AC220V(A 1526B)
  • Cord length 1.6m
  • Total length (without cord) 250 (L) mm
  • Weight 0.6kg
  • Packing size 320X205X60mm
  • Power supply oAC110V/60HZ oAC220V/50HZ

This product is protected against electrostatic discharge. Specifications and design are subject to change without notice.

CAUTION

  • Do not touch the metallic parts near the tip.
  • Do not use the produce near flammable items.
  • Do not face the spurt-tip to the worker face.
  • Advise other people in the work area that the unit can reach a very high temperature.
  •  Turn the power off while taking breaks and when you are finished using it.
  • Before replacing parts or or storing the unit,turn the power off and allow the unit to cool to room temperature.
  • Do not close the flammable,paper,or other flammable material,is damage to the worker.For new equipment,do not touch the heating tube or hot air spurting.
  • Please avoid falling off or violent shaking for fear of damage. ‘ A..,
  • Instead of the exothermic material parts must be same … parts in a opposite diredtion.
  • Make sure turn off the power when you are not working.

Note :Turning offthe power. the system continues sending cool air until the temperature is lower down to so, protecting the elements from high temperature damage.

operation

OFP Desoldering

A:Preparation for working
Choose the proper dimension (integration model. pull-out copper cord, spurt- tip and fixed them completely Place the FP pick-up under the IC lead. Slip the FP pick-up wire under the IC lead. (Figure 1) If the width of the IC does not match the size of the FP pick-up,adjust the width of the pick-up by squeezing the wire. In case of PLCC or small components such as chip resistors, desolder by using tweezers,etc

Turn on Operation

  • a. Connect power and remember to use the equipment after grounded;
  • b. Turn on the power switch of host;
  1. If the display screen of DES 560B and DES 560C is I OFF I after displaying the originally set temperature and air volume, the system is in standby mode instead of working. (As shown in Figure 1 and 2);
  2. Please set the required temperature and air volume before work. (See below for adjustment of temperature and air volume)

Operation Temperature
HEATER knob on panel is a knob for adjustment of temperature and the adjustable range is 80’c~600°C. Rotate the knob right to increase temperature and left to decrease temperature

  1. Taking DES 560B as an example: while rotating the temperature adjusting knob, the display screen should show the temperature required to be set, such as 350’c; (as shown in Figure 1 );
  2. Taking DES 560C as an example: while pressing keys to increase or decrease temperature, the display screen should show the temperature required to be set, such as 350’c; (as shown in Figure 2);

Operation Air Quantity
AIR knob on panel is a knob for adjustment of air volume and the scope of air volume is grade 1-8. Rotate the knob right to increase air volume and left to decrease air volume. the pointer should point at the required air volume.

  1. Taking DES 560B as an example: while rotating the air volume adjusting knob, the display screen should show the air volume required to be set, such as grade 5; (as shown in Figure 1 );
  2. Taking DES 560C as an example: while pressing keys to increase or decrease air volume, the display screen should show the air volume required to be set, such as grade 5; (as shown in Figure 2

Cleaning tin course

  1. After temperature and air volume are set, keep pressing the start button to enter working condition;
  2. If long-time work is required, continuously press the start button twice to maintain the working condition; the display screen shows temperature value when it is in working position;
  3. Heating After the stability temperature, the pull-out equipment is on integration model,letting the tip shoot at the part by heating air melting(the spurt-tip is above the integration).
  4. Remove the IC Once the solder has melted, remove the IC by lifting the FP pick=up. (Figure 1)
  5. Remove any remaining solder. After removing the IC,remove remaining solder with a soldering iron and wick or desoldering tool.

Turn off Operation

  1. lf shutdown is required, keep pressing start button will be shown.and then the machine will stop heating. During this stage, don’t unplug the power plug. Until about one minute later when the temperature in spray nozzle sleeve drops to below 80’c, will the fan stop automatically. The power switch can only be turned off after the fan stop working to prevent overheating of the heating element.
    CAUTION
    During the cooling process, the amount of air is controlled by the setting of the air flow adjustment knob. It recommends setting the knob at maximum when cooling for greatest effciency

  2. Turn the power switch off. After the flowing function finished,turn off the power switch

Error display
If the product is in trouble,the sign will display.

  • The machine is stopped in a forced way because the heating element breaks down, the temperature is out of control or beyond the upper limit.
  • The fan breaks down. Please replace it
  • It is indicated when heating core is not connected

QFP Soldering

  1. Apply the solder paste.
    Apply the proper quality of solder paste and install the SMD on the PWB.

  2. Preheat the SMD
    Refer to the figure 1 to preheat SMD.

  3. Soldering
    Heat the lead frame evenly. (Figure 2)

  4. Cleaning
    When soldering is completed,clean the residual flux from the board with an appropriate cleaner.

CAUTION
Soldering with hot air has many advantages,such as the inherent ability to pre-heat the component being replaced.As with any soldering process, however,there is always the possibility of forming solder balls,bridges between leads,and inadequate solder joints.Always inspect the finished solder joints for structural and electrical integrity

Keep pressing start button to close the heating state If it is DES 560B/560C, OFF will be shown, and then the machine will stop heating. Until the temperature in spray nozzle sleeve drops to below 80’C about one minute later, will the fan the fan stop autom-atically. Therefore, the power plug cannot be un-plugged during cooling stage.

Turn the power switch off.
After the flowing function finished,turn off the power switch

Removable Accessories

  1. High temperature set of head:
  2. Exothermic material

Maintenance/Inspection

Broken heating element

CAUTION
Replacing the heating element is very dangerous. Be sure to turn the power switch OFF and becareful of the following procedure when replacing the heating element.

  1. Take out the high-temperature casing head; firstly, rotate the casing head, and then take off it when the two triangles at back are aligned (as shown in Figure 1 ).

  2.  Take off the 5P extension cord (as shown in Figure 2) connected with handle, then take off the 3 screws fixing sleeve of heating element, and last, take off the sleeve and heating element (as shown in Figure 3). CAUTION
    Handle the heating element with care.Never rub the heating element wire!

  3. Replace new heating element as well as the sleeve.

  4. Assembled to the original shape (as shown in Figure 4 ).

parts list

Item NO. Part No. Part Name Specifications
1 WWJ00106 Booting tube Vortex
2 CFR00057 Exothermic material A1525B 220V 550W
3 CFR00058 Exothermic material A1526B 110V 550W
4 SSJ00147 High temperature set of head GPS
SSJ00158 High temperature set of head GP6(purchase additionally)
5 SSJ00148 Power-on Button
6 SSJ00149 Knob1 cp9mm
7 SSJ00149 Knob2 <1>9mm
8 SSJ00119 CAL rubber plug
9 SM800034 PVC panel 22*50mm
10 DDJ00010 DCTurbinefan (excludingdimension of lines) 40•40•2omm
11 SSJ00150 Upper enclosure cp44*176mm
12 SSJ00151 Lowerenclosure cp44*176mm
13 ZDL00034 P.W.B. Silicon controlled and other parts
14 DKG00023 Power switch Maximum Diameter 16.5mm
15 SSJ00001 Line sheath Silica gel

16

| DXC00045| Powercord,3wiredcord&Europeanplug| 220V KTL,230V CE
DXC0000B| Powercord,3wiredcord&Chinese plug| China
17| CPZ00022| Spray nozzle NS05| q,5(1O)
18| CPZ00023| Spray nozzle NS08| <1>8(10)
19| WLS00060| Crossed self-tapping screw| PT2. 610mm
20| WLS000SS| Crossed self-tapping screw| PT2. 6
5mm
21| WLS00034| Crossed self-tapping screw| PM2*5mm

OPTIONAL NOZZLES

CAUTION
The size in Name/ Specification indicates the size of IC package

Air nozzle with vacuum function

We are entitle to restore the produce capability & technique parameter.without noticing additional.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals