Emitever KVG-DW Series 120W Dimmable LED Driver
Product Information
Specifications
- Model: KVG-DW Series 120W
- Whole Family: KVG-XXXXX-DWJ 12V/ 24V DC – [ 30W 60W 80W 96W 100W 120W 150W 200W 300W 600W ]
- Output Range: Constant Voltage
- Input Voltage Range: 100-277VAC
- PFC design: Built-in active PFC function
- Efficiency: Up to 84%
- Protections: Short circuit/overload/over-temperature
- Heat dissipation: Cooling by free air convection
- Waterproof performance: Suitable for dry, damp, wet locations
- Dimming function: Phase dimming (work with forward phase, MLV and Reverse phase, ELV, TRIAC dimmers) and 0-10V dimming (0-10V/1-10V/Potentiometer/10V PWM)
- Dimming range: 0-100%
- Application: Suitable for LED lighting and moving sign applications
- Warranty: 5 years
Product Usage Instructions
Installation
- Ensure that the input voltage is within the specified range of 100-277VAC.
- Connect the input wires to the corresponding AC power source.
- Connect the output wires to the LED lighting or moving sign application.
- Make sure all connections are secure and insulated.
Dimming Function
The dimmable LED driver supports both phase dimming and 0-10V dimming.
Phase Dimming
To use phase dimming, follow these steps:
- Ensure that the LED driver is connected to a compatible forward phase, MLV, or reverse phase, ELV, TRIAC dimmer.
- Turn on the AC power source.
- Use the dimmer control to adjust the brightness of the LED lights or moving sign.
0-10V Dimming
To use 0-10V dimming, follow these steps:
- Ensure that the LED driver is connected to a compatible 0-10V dimmer, 1-10V dimmer, potentiometer, or 10V PWM dimmer.
- Turn on the AC power source.
- Adjust the dimmer control within the range of 0-10V to achieve the desired brightness level.
FAQ (Frequently Asked Questions)
-
Q: What is the input voltage range for this LED driver?
A: The input voltage range is 100-277VAC. -
Q: What types of dimmers are compatible with this LED driver?
A: This LED driver is compatible with forward phase, MLV, and reverse phase, ELV, TRIAC dimmers for phase dimming. It is also compatible with 0-10V dimmers, 1-10V dimmers, potentiometers, and 10V PWM dimmers for 0-10V dimming. -
Q: Can I use this LED driver in wet locations?
A: Yes, this LED driver has waterproof performance and can be used in dry, damp, and wet locations. -
Q: What is the warranty period for this LED driver?
A: This LED driver comes with a 5-year warranty.
Whole Family: KVG-XXXXX-DWJ 12V/ 24V DC – [ 30W 60W 80W 96W 100W 120W 150W 200W 300W 600W ]
Features
- Output: Constant Voltage
- Range: 100-277VAC
- PFC design: Built-in active PFC function
- Efficiency: Up to 84%
- Protections: Short circuit/ over load/ over temperature
- Heat dissipation: Cooling by free air convection
- Waterproof performance: For dry, damp, wet locations
- Dimming function:
- Phase dimming: work with forward phase, MLV and Reverse phase , ELV, TRIAC dimmers.
- 0-10V dimming: 0-10V/1-10V/Potentiometer/10V PWM 4 in 1
- Dimming range: 0-100%
- Application: Suitable for LED lighting and moving sign applications
- Warranty: 5 years warranty
Specification
Model | KVG-12120-DWJ | KVG-24120-DWJ |
---|---|---|
Certificate | UL / cUL / FCC / CE / Rohs / REACH | |
Output | DC Voltage | 12V |
Voltage Tolerance | ±0.5V | |
Voltage Regulation | ±0.5% | |
Rated current | 10A | 5A |
Rated power | 120W | |
Load Regulation | ±2% | ±1% |
Input | Voltage Range | 100-277VAC |
Frequency Range | 47 – 63Hz | |
Power Factor (Typ.) @ full load | 0.99@120VAC 0.96@277VAC | 0.98@120VAC |
0.95@277VAC
THD(Typ. ) @ full load| <20%@120VAC & 277VAC
Efficiency(Typ.) @ full load| ≥82%@120VAC ≥83%@277VAC| ≥82%@120VAC
≥84%@277VAC
AC Current (Max.)| 1.7A
Inrush Current (Typ.)| 20A, 50%, 1.6ms @120VAC; 25A, 50% 1.2ms @277VAC
Leakage current| <0.5mA
Protection| Short Circuit| Shut down o/p voltage, re-power on to recover
after fault condition removed
Over Load| ≤120% constant current limiting, auto-recovery after fault
condition removed
Over temperature| 100℃±10℃ shut down o/p voltage, automatically recover after
cooling
Environment| Working TEMP.| -40~+60℃ (see below derating curve)
Working Humidity| 20 – 95%RH non-condensing
Storage TEM.,Humidity| -40 – +80℃,10 – 95% RH non-condensing
TEMP.coefficient| ±0.03%/℃(0 – 50℃)
Vibration| 10~500Hz, 5G 12min./1 cycle, period for 72min. each along X,Y,Z
axes
Safety & EMC| Safety standards| UL8750 , CAN/CSA-C22.2 No.250.13
Withstand voltage| I/P-O/P: 1.8KVAC I/P-FG: 1.8KVAC O/P-FG1.8KVAC
Isolation resistance| I/P-O/P: 100MΩ/ 500VDC/ 25℃/ 70% RH
EMC Emission| FCC 47 CFR Part 15 ,Subpart B
Others| Net Weight| 1.364Kg
Dimension| 22095.443.8mm(LWH)
Packing| 298265220mm 10pcs /CTN
Notes| 1. All parameters NOT specially mentioned are measured at
120VAC input, rated load and 25℃of ambient temperature.
2. Tolerance: includes set up tolerance and load regulation.
Efficiency Curve (efficiency vs output load)
Derating Curve (output load vs TEMP.)
- To extend their life, please refer to the Derating Curve and derate according to the temperature.
Power factor curve
Mechanical Specification
- Input cable 3*18AWG, the Green cable to (FG), Black cable to L, and White cable to N of Mains AC
- Output cable 2*16AWG, Red cable (+) to LED Positive side (+) , Black cable (-) to LED Negative side (-).
- Dimming cable 2*18AWG, Purple cable DIM (+) to 0/1-10V dimmer signal(+ ), Pink cable DIM (-) to 0/1-10V dimmer signal (-)
- Please DO NOT connect “DIM-“ to “LED-“, “DIM+” to “ LED+”, or other incorrect connection.
- Please make sure your connect these correctly otherwise your product will not function correctly and could be damaged.
Warm tips:
- Recommended Max. Carrying Current (A) = wire diameter(mm²) x 10A/mm ² For example: 1mm ² output cable, Recommended Max. Carrying Current (A) = 1mm ² x 10A/mm ²=10A
- Any other requests for, we can customized.
Dimming Operation and Connecting Diagram
- Using two ways of dimming at the same time, you must be assured that LED lighting is up to the max. Brightness then you could operate with the other dimming;
- Using one dimming —TRIAC/Phase cut dimming
1. The Pulse-Width Modulation (PWM) of output voltage can be adjusted through input terminal of the AC phase line(L) by connection a phase /Triac dimmer or lighting system.
2. Working with forward phase, MLV and Reverse phase , ELV, TRIAC dimmers or light system.
3. Min. loading is about 10%
4. Please try to use dimmers with power at least 1.5 times as the output power of the driver.
- Using one dimming —0-10/ 1-10V/ 10V PWM/ Potentiometer dimming
Instruction
- This driver should be installed by qualified and professional person.
- Please make sure the driver is installed with adequate ventilation around it to allow for heat dissipation.
- Ensure that wiring is correct before test in order to avoid light and power supply damage.
- If driver Cannot work normally, don’t maintain privately.