Safety directions/Please read this information carefully before installing or using this product. Please keep this user manual for further reference.

  1. The lamps may only be installed by authorized and qualified technicians according to the valid regulations for electrical installation.

  2. The manufacturer does not accept any responsibility for injuries or damage resulting from improper use of the light.

  3. Maintenance of the lights is limited to the surfaces. When doing this, no moisture must come into contact with any areas of the terminal connections or main voltage control parts.

  4. Attention! Before starting the installation work, make sure that the mains power line is voltage-free – turn off the safety cutout or unscrew the protection fuse. The switch must be “OFF”.

  5. Warning! Before drilling the mounting holes, make sure that no gas, water, or electricity pipes and wires can be drilled through or damaged in your chosen mounting location.

  6. The symbol of the crossed-out garbage can on the product or the packaging means that the product must not be disposed of with ordinary household waste. At the end of its useful life, the product must be returned to a point of acceptance for the recycling of electric and electronic devices. Please ask your local municipality for the point of acceptance.

  7. Safety class II Icon. This light is specially insulated and must not be connected to an earthed conductor.

  8. Description of the supply terminals: L = Phase N = Neutral conductor **** = Earthed conductor.

  9. This product is designed for direct wiring to the mains “230 V/50 Hz”.

  10. The lamp does not have a connecting terminal. An electrician may need to be consulted to connect the lamp.

  11. You can use the following connectors (not included in delivery):
    2 screwless connectors in accordance with EN 60998-2-2 (min. 2 poles with retention clip – e.g. “WAGO series 221/222“ ) designed for a cross-section of 0.5 mm² – 1.5 mm² with a rated voltage of min. 250 V and a rated current of min. 16 A.
    The free cable ends of the light must be provided with ferrules depending on the design of the connectors. The connection to the power network must take place within a sufficiently large enough standard junction box per light (not included in delivery).

  12. Protective covers and end covers for mains voltage control parts must always be mounted.

  13. Do not install the light on a damp or conductive subsurface.

  14. Please make sure that no cables get damaged during the installation work.

  15. Attention! During operation, lamp parts and illuminants can reach temperatures of more than 60°C. Do not touch during operation!

  16. The lights have a protection class rating of “IP23“ and are solely intended for indoor use only in private households.

  17. The protection class “IP23” only applies to the visual area of the lamp when installed.

  18. The protection class “IP20” applies to the concealed area of the lamp when installed.

  19. IP degree of protection applies for ceiling suspension only.

  20. Do not look directly into the light source (illuminant, LED, etc.).

  21. The light source of this lamp is not replaceable. If the light source has reached the end of its operational life, the entire lamp must be replaced.

  22. This lamp is not suitable for dimmers and electronic switches.

  23. Never cover these lamps with heat-insulating enclosures or similar materials.

  24. LED color deviation when using different chargers may occur. The light color and luminous strength of the LEDs can also change as a result of the battery life span level.