B K Licht BKL1333 Ceiling Light Instruction Manual

June 9, 2024
B K Licht

B K Licht BKL1333 Ceiling Light

B K Licht BKL1333 Ceiling Light

INSTALLATION INSTRUCTION

B K Licht BKL1333 Ceiling Light 1

SAFETY INSTRUCTION

Safety directions / Please read this information carefully before installing or using this product. Please keep this user manual for further reference.

  1. The lamps may only be installed by authorized and qualified technicians according the valid regulations for electrical installation.
  2. The manufacturer does not accept any responsibility for injuries or damage resulting from improper use of the light.
  3. Maintenance of the lights is limited to the surfaces. When doing this, no moisture must come into contact with any areas of the terminal connections or mains voltage control parts.
  4. Attention! Before starting the installation work, make sure that the mains power line is voltage-free – turn off safety cutout or unscrew the protection fuse. The switch must be “OFF”.
  5. Warning! Before drilling the mounting holes, make sure that no gas, water or electricity pipes and wires can be drilled through or damaged in your chosen mounting location.
  6. When mounting, ensure that the attachment material is suitable for the subsurface and that this surface is capable of carrying the weight of the fixture. The manufacturer is not liable for improper installation of the item on the relevant subsurface.
  7. The symbol of the crossed-out garbage can on the product or the packaging means that the product must not be disposed with ordinary household waste. At the end of its useful life, the product must be returned to a point of acceptance for the recycling of electric and electronic device. Please ask your local municipality for the point of acceptance.
  8. Safety class II S. This light is specially insulated and must not be connected to an earthed conductor.
  9. Protection class II. Take note that when switching on that the building site supply lines available have double or reinforced insulation up to the terminal connection area. The enclosed terminal box ensures that when the building site conductors with basic insulation have a maximum length of “80 mm“.
  10. Description of the supply terminals: L = Phase N = Neutral conductor G = Earthed conductor.
  11. Protective covers and end covers for mains voltage control parts must always be mounted.
  12. Do not install the light on a damp or conductive subsurface.
  13. Please make sure that no cables get damaged during the installation work.
  14. Attention! During operation, lamp parts and illuminants can reach temperatures of more than 60°C. Do not touch during operation!
  15. The lamp may only be adjusted and positioned after having cooled down.
  16. The lights have a protection class rating of “IP20“ and are solely intended for indoor use only of private households.
  17. Do not look directly into the light source (illuminant, LED, etc.).
  18. The light source of this lamp is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
  19.  LED colour deviation when using different chargers may occur. The light color and luminous strength of the LED’s can also change as a result of life span level from the lamp.
  20. This article is not suitable for use with dimmable electric circuits. It can be controlled using the accompanying remote control.
  21. This light is fitted with an electronic changeover switch. This means that the colour temperature of the lamp is controlled by switching the power supply on and off.
    • 1 x on  It will be switched to a colour temperature of “3000K”.
    • 1 x off and within 1 sec. on again  It will be switched to a colour temperature of “4000K”.
    • 1 x off and within 1 sec. on again It will be switched to a colour temperature of “6500K”.
    • 1 x Off and On again within “1” sec.  It switches to a dimming level of approx. “10%” and to a colour temperature of approx. “3000K”.
    • Further switching on and off of the lamp means having to run through the individual stages again.
  22. It generally does not matter how the lamp is switched on (circuit-breaker, multi-switch connection or cross circuit). Essential for operation is the connection and disconnection of the lamp from the power supply.
  23. Memory function: switching on the light using the remote control or an external light switch always activates the last light colour and dimming level set.
  24.  Lamp with remote control
  25.  “B.K.Licht“ hereby declares that the radio equipment type “BKL1333“ complies with the directive “2014/53/EU“.
  26. This product works with an operating frequency of “2,4 GHz” and a transmission power of “max. 13 dBm”.
  27. Available functions of the product:
  28. The “ON” button switches the lights on with the last switch position to have been used. The “OFF” button switches the lights off.
  29. The “Dim+” and “Dim-” buttons brighten and dim the lights either in stages or continuously.
  30.  The “CW” and “WW” buttons move the colour temperature closer to cool white or warm white either in stages or continuously.
  31.  The “Night Light” button switches the lights to their dimmest setting with a colour temperature of approximately “3000K”.
  32. The “Timer” button switches the lights off after “1” minutes. The light will confirm the process with a flash “1 x“.
  33.  The push-button “WW / NW / CW“ toggles the colour temperature of the light in “3“ stages between cold white and warm white.
  34. If it is not functioning, it may be possible that the remote control needs to be paired with the light.
  35. The accompanying remote control can be connected to many different articles in the same series.
  36. Programming can only take place within a short period of approx. “3” seconds after the operating voltage has been set up on the radio receiver. Within this short period of time the “ON/OFF” must be pressed and held. The programming procedure has been successful if there is a short flash directly afterwards. If “1” remote controls have already been previously programmed on the radio receiver, the other one is deleted from the storage capacity.
  37.  Batteries or rechargeable batteries are not permitted in domestic waste. They must be decontaminated according to the regulations of the responsible authorities as hazardous waste. Use the available collection points

Dear customer
If, contrary to expectations, defects are discovered despite the latest production methods and the most precise quality controls, please contact us Please contact the following hotline, stating the date of purchase and the item number of the product: [email protected]

References