Schneider Electric PKR11241 00 Circuit Breaker Compact Installation Guide
- June 16, 2024
- Schneider Electric
Table of Contents
Schneider Electric PKR11241 00 Circuit Breaker Compact
Product Information
Specifications
- Type: HMIDM6 ATEX/IECEx
- Application: Potentially explosive atmospheres (Zones 2/22)
- Type examination certificate: INERIS 22ATEX3003U
- IECEx Certificate of Conformity: IECEx INE22.0052U
- Power Supply: 12 Vdc
Safety Instructions
Read these instructions carefully, and look at the equipment to become
familiar with the device before trying to install, operate, or maintain it.
The following special messages may appear throughout this documentation or on
the equipment to warn of potential hazards or to call attention to information
that clarifies or simplifies a procedure.
- DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
- WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
- CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
- NOTICE: Used to address practices not related to physical injury.
- PLEASE NOTE: Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to the construction and operation of electrical equipment and its installation, and has received safety training to recognize and avoid the hazards involved.
Scope
This present document applies when the HMIDM6 bears marking and provides
important information when used in hazardous areas. This documentation has to
be kept and always refer to those instructions for installation, operation,
maintenance or evolution of your system. You can download this instruction
guide at www.se.com. If any translation is needed, you can
contact your local Schneider support or sales center.
Relevant Standards
These terminals have been manufactured in accordance with: POTENTIAL FOR
EXPLOSION and other document relating to where the apparatus is installed.
Failure to follow these instructions will result in death or serious injury.
Permitted Zones of Application
Refer to the section Markings to get information about the permitted zones
of protection and the types of protection.
Product Usage Instructions
Installation
Make sure you follow all the recommendations in the user manual for each
product and additionally those listed below:
- DANGER: POTENTIAL FOR EXPLOSION
- The front surface of the product has a risk of electrostatic discharge. If the product is operating in zone 2/22 areas, the following instructions must be applied:
- The environmental conditions shall not be lower than 25% relative humidity.
- If the potential electrostatic source is higher than 30 kV, it is necessary to call an expert to evaluate the electrostatic risk and the distance between the product and the electrostatic source.
Operation
Follow the instructions provided in the user manual for proper operation of
the HMIDM6.
Maintenance
Regularly inspect and maintain the HMIDM6 according to the instructions
provided in the user manual. Ensure that any servicing or maintenance is
carried out by qualified personnel.
FAQ
-
Q: What is the power supply for the HMIDM6?
A: The HMIDM6 is only supplied with 12 Vdc. -
Q: Where can I download the instruction guide?
A: You can download the instruction guide at www.se.com. -
Q: Who should install and maintain the electrical equipment?
A: Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel who have skills and knowledge related to the construction and operation of electrical equipment and its installation, and have received safety training to recognize and avoid hazards involved.
HMIDM6
ATEX/IECEx Instruction Guide
Concerning the use of HMIDM6 for applications in potentially explosive atmospheres (Zones 2/22)
- Schneider Electric
- 8ème rue, ZI Carros
- 06516 Carros cedex – France
- Type examination certificate: INERIS 22ATEX3003U
- IECEx Certificate of Conformity: IECEx INE22.0052U
SAFETY INSTRUCTIONS
- Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
- The addition of this symbol to a “Danger” or “Warning” safety label indicates that an electrical hazard exists, which will result in personal injury if the instructions are not followed.
- This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
The information in this document is subject to change without notice. Copyright © 12/2022 Schneider Electric
- All Rights Reserved.
- PKR11241 00
- Printed in
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
PLEASE NOTE
Electrical equipment should be installed, operated, serviced, and maintained
only by qualified personnel. No responsibility is assumed by Schneider
Electric for any consequences arising out of the use of this material. A
qualified person is one who has skills and knowledge related to the
construction and operation of electrical equipment and its installation, and
has received safety training to recognize and avoid the hazards involved.
SCOPE
- This present document applies when the HMIDM6 bears marking and provides important information when used in hazardous areas. This documentation has to be kept and always refer to those instructions for installation, operation, maintenance or evolution of your system.
- You can download this instruction guide at www.se.com .
- If any translation is needed, you can contact your local Schneider support or sales center.
- The products are only supplied with 12 Vdc.
Relevant Standards
These terminals have been manufactured in accordance with:
- Standard EN IEC 60079-0 (2018) and IEC 60079-0 (2017): Explosive atmospheres – Part 0: Equipment – General requirements.
- Standard EN IEC 60079-7 (2015) + A1 (2018) and IEC 60079-7 (2017): Explosive atmospheres – Part 7: Equipment protection by increased safety “e”.
- Standard EN 60079-15 (2010) and IEC 60079-15 (2017): Explosive atmospheres – Part 15: Equipment protection by type of protection “n”.
- Standard EN 60079-31 (2014) and IEC 60079-31 (2013): Explosive atmospheres – Part 31: Equipment dust ignition protection by enclosure “t”.
DANGER
POTENTIAL FOR EXPLOSION
- Install, use, and maintain these modules in accordance with:
- Standard IEC 60079-14: Explosive atmospheres – Part 14: Electrical installations design, selection and erection.
- Standard IEC 60079-17: Inspection and maintenance of electrical installations in hazardous areas.
- Edicts, by-laws, laws, directives, circulars, standards, regulations and any other document relating to where the apparatus is installed.
- Failure to follow these instructions will result in death or serious injury.
Permitted zones of application
- Refer to the section “Markings” to get information about the permitted zones of protection and the types of protection.
- The product installed in zones 2/22 hazardous areas must be certified and bear the marking.
- Ensure with the marking that the terminals are compatible with the conditions permitted for the hazardous area at the site where it is being used.
Installation, Operation and Maintenance
Make sure you follow all the recommendations in the user manual for each product and additionally those listed below.
DANGER
POTENTIAL FOR EXPLOSION
- Confirm that the location is free from explosively hazardous gases or dust before connecting or disconnecting equipment, replacing or wiring modules.
- Make sure that the ambient temperature in protective enclose never exceeds the temperature marked on the product.
- Confirm each interface (COM, Ethernet, USB, power line, …) has been securely locked.
- Confirm that any USB cable has been attached with its appropriate clamp.
- Install the modules in an enclosure EPL Gc insuring a minimal ingress protection IP54 for use in zone 2 and in an enclosure EPL Dc insuring a minimal ingress protection IP6X for use in zone 22.
- Make sure the purging test inside the product is performed and validated in accordance with IEC 60079-2 when installed in an IP4X pressurized enclosure.
- Do not install the modules in the environment more than Pollution Degree 2 as defined in IEC 60664-1.
- Do not open the enclosure when an explosive atmosphere is present.
- Confirm that the power supply has been turned OFF before disconnecting, replacing or wiring modules.
- Ensure that ground at power supply is properly connected.
- Do not use equipment that has been damaged.
- Do not expose the terminal to direct sunlight.
- Do not allow layers of dust to form on the product: it should be cleaned regularly.
- Implement method to avoid risk of electrostatic discharge at using zone 2 and 22 areas. See the details at NOTE.
- Add the warning for potential electrostatic charging hazard in a location visible by the operator after installation in order to maintain the required level of safety.
- Take into consideration during the installation, that the product underwent only a shock corresponding to an energy of a low risk at 2J.
- Mount the display in an enclosure according to the installation procedures described in the user manual.
- Ensure that the power source for this product has transient protection set to a voltage level not exceeding 140% of the peak rated voltage.
- Failure to follow these instructions will result in death or serious injury.
- NOTE: The front surface of the product has risk of electrostatic discharge. If the product is operating in zone 2/22 areas, the following instructions must be applied:
Analog resistance film touch panel type:
- Use non-conductive gloves (e.g. Electro soft Latex Gloves by Honeywell Safety) made of leather, plastic or rubber whose surface resistance is more than 1 GΩ at 23 ± 2 °C and 50 ± 5 % relative humidity.
- Use a non-conductive touch pen (XBTZGPEN by Schneider Electric) made of plastic material whose surface resistance is more than 1 GΩ at 23 ± 2 °C and 50 ± 5 % relative humidity to all terminals.
Capacitive touch panel (P-CAP) type:
Install the product away from 1,000 mm distance from a potential electrostatic
source (e.g. plant process, conveyor belt, pipe, etc). The environmental
conditions shall not be lower than 25 % relative humidity. If the potential
electrostatic source is upper than 30 kV, it is necessary to call an expert to
evaluate the electrostatic risk and the distance between the product and the
electrostatic source.
Markings
ATEX and IECEx markings, applied to the product are as follows:
- Schneider Electric
- 06516 Carros – France
- INERIS 22ATEX3003U
- IECEx INE 22.0052U
- II 3 G D
- Ex ec nC IIC Gc or Ex ec IIC Gc Ex tc IIIC Dc
- Tamb :
- 0°C to +50°C or
- 0°C to +60°C
WARNING
- Do not disconnect when circuit is live
- Potential electrostatic charging hazard (see instructions)
NOTE: Other required elements such as product reference, serial number
and date code of manufacture are already marked on products.
All models may be followed by alphanumeric characters and there is no impact
safety related critical components and constructions.
EU DECLARATION OF CONFORMITY
- We: Schneider Electric Industries SAS
- 35 rue Joseph Monier
- Rueil Malmaison 92500 – France
Declare under our sole responsibility that the products:
Trademark|
---|---
Name| HMIDM6
Type| Display Unit
Models|
- HMIDM6600TM,
- HMIDM6700TM,
- HMIDM6500WC,
- HMIDM6600WC,
- HMIDM6700WC,
- HMIDM6800WC,
- HMIDM6900WC
Includes models with additional alphanumeric characters at the end of the model number.
Are in conformity with the requirements of the following directives and conformity was checked in accordance with the following standards.
Directive | Harmonized standard / Notified body reference |
---|---|
- EN IEC 60079-0: 2018 + AC: 2020,
- EN IEC 60079-7: 2015 + A1: 2018,
- EN 60079-15: 2010, EN 60079-31: 2014
ATEX Directive 2014/34/EU| Type examination certificate:
- INERIS 22ATEX3003U and IECEx INE 22.0052U II 3 G D
- Ex ec nC IIC Gc or Ex ec IIC Gc Ex tc IIIC Dc
Tamb:
- 0°C to +50°C or
- 0°C to +60°C
| By INERIS: Parc Technologique ALATA, 60550 Verneuil en Halatte – France
- Subject to correct installation, maintenance and use conforming to its intended purpose, to the applicable regulations and standards, to the supplier’s instructions and to accepted rules of the art. This declaration becomes invalid in the case of any modification to the products not authorized by us.
- Compliance with the ATEX Directives will require the application of ATEX guide giving requirements, details and advices for installation of products used.
- The guides are available on www.se.com
- Issued at F-06516 Carros : 2022.12.19
Name: Samuel MAREAU
Digital Factory
Manager Compliance & Certification
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>