Use
Mounng system for installing framed PV modules with heights between 30 and 50 mm on pitched roofs with the following characteristics:
- Roof pitch 5° – 60° (solar fasteners), 20°- 60° (Roof hooks)
- Single and double roman, plain le, natural slate, and flat es with wooden substructures.
- PV-panel landscape and portrait oriented
Static calculation must exist and be considered according to local regulations.
Installation guidelines
Ensure that the roof construction is suitable for the introduction of forces at the fixing points and their subsequent transmission. In order to compensate thermal expansion, included a break every 12 meters when planning the PV- system. For module positioning/fastening points please refer to manufacturers recommen- dations. Please follow your local timber construction standard. Please do not use installed roof connections as ladder.If installation is located within 10km from the coast, we advice not to use zinc coated material. For further information please contact your sales representative or the technical depart-ment at ITT Bulgaria EOOD.
The structural stability of the PV- system must be verified before installation. The building must be able to support the additional weight safely.
Installation notes
Please read these installation instructions carefully before starting the installation and familiarise yourself with the system components. During the installation and in particular whilst working on the roof, ensure to work according to the relevant health and safety guidelines, safety guidelines and please follow the current rules and regulations for your corresponding region.
The individual installation instructions are merely recommendations in accordance with the current state of technology and are based on previous experiences of how systems can be installed
If any special characteristics of the roof or object need to be taken into account, we recommend you to consult specialists such as roofers or structural engineers where necessary. Please check that the applied manual which is up to date. All manuals are available in the download area at https://itt-shop.bg/
Testing/certification:
- TÜV
- MCS012 (IK0197)
- ISO 9001
“General installation, maintenance and as- sembly instructions” “Safety Instructions for Installation Instruc- tions”
These documents are available at https://itt-shop.bg/
ITT Bulgaria EOOD is not accountable for the roofs capability to maintain the intro- duced forces. Please check the roofs com- patibility with a static engineer.
TIN ROOF MOUNTING System
SOLAR PANELS LAYOUT
**Step.1. Spread out the inclined beam and the angle adjustment tube of the A frame kit.
**
Step.2 Bolt the A frame kitto the base structure securely. The A frame kit
can be installed on the ground or metal roofs. (Recommended Torque: 9-11N.M)
It is recommended to apply polyurethane (PU) waterproof glue to achieve
complete waterproofing, if the roof involves perforated installation
Step.3 Remove accessories package M8 60 screw group.Align the upper hole
of the angle adjustment tube with the threaded hole of the inclined beam.
Tighten the M860 bolt securely. (Recommended Torque 12-14N.M)
Step.4 Ensure that all the A frame kits are aligned. Ensure the correct
spacing of each A frame kit in accordance with design specifications.
Step.5 Assemble the rail clamps correctly on the pre assembly bracket according to the drawing, then place the beam, and finally lock the M8 bolt on the rail clamps.
Installing the rail
Step. 1 There are type for the SSC rail.( SSC rail Outer Joiner)
OR There are type for the SSC rail. ( Select Rail Joiner)
Install Select panel clamps
-
Against the panel, Hold it with your thumb
-
Against the panel, Hold it with your thumb
Attention:
- The panel clampis close against the solar panel.
- Tighten the bolt slowly, until the clamp in holding position.
- Then use 12-14N.M torque to tighten the bolt.
*Ensure The Lock Nuts Are Secured to Rail.
Solar panel installation completed. Double check ensure all bolts be tighten
COMPONENTS
Part nam| SSC Rail| Select Rails Joiner|
---|---|---|---
Part No.| SLR ACC03| SLR ACC04|
Figure| | |
Part name| Adjustable A-Frame Leg| SSC Rail Clamp|
Part No.| SLR ACC05| SLR ACC06|
| | |
Part name| End Clamp Kit| Inner Clamp Kit| Standard Earthing Plate
Part No| SLR ACC02| SLR ACC01| SLR ACC10
| | |