omega HHSL-101 USB Digital Sound Level Data Logger User Guide
- June 12, 2024
- Omega
Table of Contents
- HHSL-101 USB Digital Sound Level Data Logger
- INTRODUCTION
- KEY FEATURES
- SAFETY INSTRUCTION
- WHAT’S IN THE PACKAGE
- PRODUCT OVERVIEW
- SETUP INSTRUCTIONS
- OPERATING INSTRUCTIONS
- SPECIFICATIONS
- MAINTENANCE TIPS
- WARRANTY/ DISCLAIMER
- RETURN REQUESTS/ INQUIRIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HHSL-101
USB Digital Sound Level
Data Logger
User’s Guide
HHSL-101 USB Digital Sound Level Data Logger
omega.com
info@omega.com
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
Stamford, CT 06907-0047 USA
Toll-Free: 1-800-826-6342 (USA & Canada
only)
Customer Service: 1-800-622-2378 (USA &
Canada only)
Engineering Service: 1-800-872-9436
(USA & Canada only)
Tel: 203-359-1660 Fax:
203-359-7700
e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
The information contained in this document is believed to be correct, but
OMEGA accepts no liability for any errors it contains, and reserves the right
to alter specifications without notice.
INTRODUCTION
Thank you for purchasing the HHSL-101 USB Digital Sound Level Data Logger.
Please read this user’s manual carefully and thoroughly before using the
instrument.
The HHSL-101 is a low-cost, compact, battery-powered sound level meter capable
of unattended logging (recording) of the decible level of an environment for
days, weeks, or months. Data logging can be started or stopped by pushing a
button on the unit, eliminating the need to bring a laptop to the job site.
Windows® 7 and Windows® XP are registered trademarks of Microsoft Corporation.
After a data log has been captured and stored, it can be uploaded as a .txt
file to any PC running the Windows® 7 or Windows® XP operating system after
plugging the HHSL-101 into one of the computer’s USB ports. The HHSL-101’s
internal flash memory is large enough to store up to 32000 data points.
Included with the product—which is slightly larger than a thumb drive—is a
mini-disc with the drivers needed to interface the unit to the computer, as
well as software that can display a data log file as a table or graph and/or
export it to Microsoft Excel. Exporting to Excel is recommended for
sophisticated trending and analysis of sound level data and easy detection of
unexpected excursions.
KEY FEATURES
- One button starts/stops data logging without a PC
- Plug-and-play USB 2.0 interface; no need for cables, cradles or docks
- Large storage capacity offers the ability to track, store, and download 32,000 data points into Excel-Format.
- LCD displays real time sound level
- A/C frequency weighting
- FAST/SLOW time weighting
- MAX/MIN/AVG displays
- High and low alarm limit, selectable sampling time
- Ability to analyze data in graph view using included software and also print or save the results.
SAFETY INSTRUCTION
Do not use the HHSL-101 in the presence of flammable or explosive gases.
WHAT’S IN THE PACKAGE
The HHSL-101 comes in a blister pack containing:
- The instrument (with included “1/2 AA” battery)
- A disc with software drivers for Windows® 7 or Windows® XP computers, a program for capturing data logs and displaying them as curves, a software installation and operation manual, a PDF of this user’s manual
- A stand to mount the instrument
- A USB extension cord
- A hard copy of this user’s manual (inside the fold-over card)
PRODUCT OVERVIEW
Fig. 1 shows the main components, controls, display and connectors of the
HHSL-101. names and functions before moving on to the Setup
Instructions.A. Microphone
B. Function button
C. LCD
D. Protective cap
E. Full-size USB plug
SETUP INSTRUCTIONS
INSTALL THE BATTERY
The HHSL-101 uses a 3.6VDC “1/2 AA” Lithium-ion battery (included). To open
the battey compartment, use a screwdriver with a fine point to push in the
silver flange showing through the small square hole in the rear of the unit.
Push back the cover, insert a fresh battery in the correct orientation, and
replace the cover, pushing it forward until you feel and hear a click.
Note: If the battery is removed from a unit before it has been set up from
software or while it is recording, the unit must be reconfigured before it can
be reactivated. If it is not reconfigured, the unit will remain in standby
mode.
Replacement “1/2 AA” batteries are available from Omega (part no. OM-EL-BATT).
SOFTWARE, DRIVERS, CONFIGURATION
Please refer to the software manual on the CD for installation, configuration
and operating instructions.
OPERATING INSTRUCTIONS
DEPLOY THE UNIT
The HHSL-101 is particularly easy to deploy on a job site because the unit
does not need to be plugged into a computer to be activated (ready to start
logging data). The HHSL-101— with its protective cap on—can be deployed either
by laying it on a horizontal surface or by mounting it onto the stand
provided.
BUTTON FUNCTIONS
To turn on the device, press and hold the unlabeled yellow Function button
(Fig. 1, Callout B) for 3 seconds. If the device has not yet been activated,
this operation will activate the device and the LCD will display Log. If the
device is already activated, this operation will deactivate the logger and the
LCD will display Con. If the memory is full, the LCD will display FUL during
recording. The data logger has 5 display modes which are Normal, Max, Avg and
Status. Press the button briefly to switch between these modes.
Normal: displays current sound level
Max: displays the maximum reading recorded since activation of this mode
Min: displays the minimum reading recorded since activation of this mode
Avg: displays the average value of readings recorded since activation of this
mode
Status: displays status of the device
Log: currently logging data
Con: inactive; connect to computer to configure for next data logging session
Ful: memory is full — configured and ready to start logging
SPECIFICATIONS
Range: 30~130dB Resolution: 0.1dB Accuracy: ±1.5dB
Max capacity: 32000 data points Link Protocol: USB 1.0/2.0
Power supply: DC3.6V Li Battery Capacity: 1200mAh
Working current: <1mA
Operating temperature: 32° to 122°F (0° to 50°C)
Operating humidity: 10-90%RH non-condensing
Storage temperature: 14° to 122°F (-10° to 50°C), 5% to 95%RH w/o battery
Dimensions: 7.09 x 1.10 x 1.06 in. (180 x 28 x 27 mm)
Weight: 2.01 oz. (57g) w/o battery
MAINTENANCE TIPS
- Avoid dropping the unit. Do not subject it to violent shock or vibration or expose it to strong electromagnetic fields (for example, near arc welders or induction heaters).
- Keep the unit out of direct sunlight.
- Do not use chemicals or abrasive cloth to clean the display window or housing.
- Before storing the HHSL-101 for an extended period of time (several months or more), remove the battery to avoid having it leak and damage the unit.
WARRANTY/ DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials
and workmanship for a period of 13 months from date of purchase. OMEGA’s
Warranty adds an additional one (1) month grace period to the normal one (1)
year product warranty to cover handling and shipping time. This ensures that
OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation.
OMEGA’s Customer Service Department will issue an Authorized Return (AR)
number immediately upon phone or written request. Upon examination by OMEGA,
if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action
of the purchaser, including but not limited to mishandling, improper
interfacing, operation outside of design limits, improper repair, or
unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result
of excessive corrosion; or current, heat, moisture or vibration; improper
specification; misapplication; misuse or other operating conditions outside of
OMEGA’s control. Components in which wear is not warranted, include but are
not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products.
However, OMEGA neither assumes responsibility for any omissions or errors nor
assumes liability for any damages that result from the use of its products in
accordance with information provided by OMEGA, either verbal or written. OMEGA
warrants only that the parts manufactured by the company will be as specified
and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY
KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED
WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The
remedies of purchaser set forth herein are exclusive, and the total liability
of OMEGA with respect to this order, whether based on contract, warranty,
negligence, indemnification, strict liability or otherwise, shall not exceed
the purchase price of the component upon which liability is based. In no event
shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall
it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with
any nuclear installation or activity; or (2) in medical applications or used
on humans. Should any Product(s) be used in or with any nuclear installation
or activity, medical application, used on humans, or misused in any way, OMEGA
assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER
language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA
harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
RETURN REQUESTS/ INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer
Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST
OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE
DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number
should then be marked on the outside of the return package and on any
correspondence. The purchaser is responsible for shipping charges, freight,
insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS , please have the following information available
BEFORE contacting OMEGA:
- Purchase Order number under which the product was PURCHASED,
- Model and serial number of the product under warranty, and
- Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
- PurchaseOrder number to cover the COST of the repair,
- Model and serial number of the product, and
- Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an
improvement is possible. This affords our customers the latest in technology
and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2016 OMEGA ENGINEERING, INC. All rights reserved. This document
may not be copied, photocopied, reproduced, translated, or reduced to any
electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com SM
TEMPERATURE
MU Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
MU Wire: Thermocouple, RTD & Thermistor
MU Calibrators & Ice Point References
MU Recorders, Controllers & Process Monitors
MU Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
MU Transducers & Strain Gages
MU Load Cells & Pressure Gages
MU Displacement Transducers
MU Instrumentation & Accessories
FLOW/LEVEL
MU Rotameters, Gas Mass Flowmeters & Flow Computers
MU Air Velocity Indicators
MU Turbine/Paddlewheel Systems
MU Totalizers & Batch Controllers
pH/CONDUCTIVITY
MU pH Electrodes, Testers & Accessories
MU Benchtop/Laboratory Meters
MU Controllers, Calibrators, Simulators & Pumps
MU Industrial pH & Conductivity Equipment
DATA ACQUISITION
MU Data Acquisition & Engineering Software
MU Communications-Based Acquisition Systems
MU Plug-in Cards for Apple, IBM & Compatibles
MU Data Logging Systems
MU Recorders, Printers & Plotters
HEATERS
MU Heating Cable
MU Cartridge & Strip Heaters
MU Immersion & Band Heaters
MU Flexible Heaters
MU Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
MU Metering & Control Instrumentation
MU Refractometers
MU Pumps & Tubing
MU Air, Soil & Water Monitors
MU Industrial Water & Wastewater Treatment
MU pH, Conductivity & Dissolved Oxygen Instruments
Shop online at
omega.com SM
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
M5562/0416
References
- Omega Engineering | Sensing, Monitoring and Control Solutions
- Global Presence | Omega Engineering
- Omega Engineering | Sensing, Monitoring and Control Solutions
Read User Manual Online (PDF format)