Product Information
Specifications
- Product Name: Wireless 6 or 10 Zones Water Heating Controller Heat & Cool
- Model Numbers: WFC-03 6Z HC RF 24, WFC-03 10Z HC RF 24, WFC-03 6Z HC RF 230, WFC-03 10Z HC RF 230
- Connectivity: Wireless
- Zones: 6 or 10
- Power Supply: 24VAC or 230VAC
- Website: wattswater.eu
FAQ
- Q: What is the maximum number of zones supported by this controller?
- A: The Wireless Water Heating Controller supports either 6 or 10 zones, depending on the model.
- Q: What is the power supply requirement for this controller?
- A: The controller can be powered by either 24VAC or 230VAC, depending on the model.
- Q: What are the compatible actuators for this controller?
- A: The controller is compatible with 230V/24V NC/NO actuators up to 2W. Compatible actuators include BT-A03 RF, BT-D03 RF, BT-DP03 RF, BT-CT02 RF, BT-CT03 RF, and WFC-03 HCM RF 230.
Product Usage Instructions
Installation
- Ensure all power sources are turned off before installation.
- Refer to the installation manual for detailed instructions on how to install the Wireless Water Heating Controller.
- If using the TRF02 230/24 option, connect it to the appropriate power source.
- Connect the RF Room thermostats to the Heat Pump or Boiler.
- Connect the NC or NO Actuators to the appropriate zones.
- If using the TRF03 230/24 option, connect it to the appropriate power source.
- Connect the MASTER and SLAVE controllers according to the provided diagram.
Operation
Once the installation is complete, follow these steps to operate the Wireless Water Heating Controller:
- Turn on the power supply.
- Use the LED/zone demand buttons to control the heating or cooling for each zone.
- Monitor the status of the system through the display panel.
- Use the USB SW update Datalog feature to update the software if necessary.
- Connect the RF Antenna (optional) for improved wireless communication.
What In The Box
Information
Connections
Safety warnings and operating instructions
This product should be installed preferably by a qualified professional. Subject to observation of the above terms, the manufacturer shall assume the liability for the equipment as provided by legal stipulations. All instructions in this Quick Installation Guide should be observed when working with the controller. Failures due to improper installation, improper use or poor maintenance are voiding manufacturer liability. Any attempt to repair voids the responsibility and the obligation to guarantee and replacement from the manufacturer.
Installation Instructions
Dimensions
Specifications
- Maximal humidity percentage: 85% at 20°C (68°F)
- Electrical protection: Class II with functional earth
- IP protection: IP30
- Shipping and storage temperature: -10°C to 50°C (14°F to 122°F)
- Power supply: 230 Vac ± 10% 50Hz
- 24 Vac ± 10% 50Hz (with transfo)
- Output maximum load (2 outputs): Relay: 5A
- Actuators: 230V /24V NC/NO up to 2W
- Compatibility : BT-A03 RF / BT-D03 RF / BT-DP03 RF / BT-CT02 RF
- BT-CT03 RF / WFC-03 HCM RF 230
Contacts
Watts Electronics S.A.S.
- B.P. N°10 – Z.A. des Tourettes • 43800 ROSIERES • France
- Tél. +33 (0)4 71 57 40 49
- Fax. +33 (0)4 71 57 40 90
- Sales-rosieres@wattswater.com
- www.wattswater.fr
© 2023 Watts
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>