TROX UK Installation Example Schoolair D Instruction Manual

June 16, 2024
TROX UK

TROX UK Installation Example Schoolair D

Product Information

  • Specifications
    • Type: SCHOOLAIR-D
    • Application Range: Supply and extract air unit with heat exchanger and heat recovery, secondary air option (based on air quality), for installation below the ceiling slab
    • Functionality: Ready-to-operate decentralized ventilation unit
    • Intended Use: Provides good comfort levels, used for the ventilation and extract ventilation of rooms such as classrooms in schools
  • Optional Equipment and Accessories:
    • Modular control system FSL-CONTROL II, especially for decentralised ventilation systems
    • Demand-based fresh air volume
    • Free cooling and night purge, depending on the control strategy
    • Automatic switching to secondary air mode (based on air quality)
    • Variable heat recovery
    • Powder-coated RAL 9005 (black, casing) or RAL 9010 (white, cover)

Product Usage Instructions

  • Installation
    • The SCHOOLAIR-D unit should be installed below the ceiling slab. Follow these steps:
    • Choose a suitable location for installation.
    • Ensure there is sufficient space for the unit.
    • Securely mount the unit using appropriate fixtures.
    • Connect the necessary electrical and ducting connections.
    • Ensure proper sealing to prevent air leakage.
  • Control System Setup
    • If you have the optional modular control system FSL-CONTROL II, follow these steps to set it up:
    • Refer to the control system manual for connection instructions.
    • Configure the control system based on your desired control strategy.
    • Set the demand-based fresh air volume.
    • Adjust the settings for free cooling and night purge if required.
    • Enable automatic switching to secondary air mode based on air quality.
  • Operation
    • Once the installation and control system setup are complete, follow these steps to operate the SCHOOLAIR-D unit:
    • Ensure the unit is connected to a power source.
    • Turn on the unit using the power switch.
    • Set the desired ventilation mode (e.g., supply air, extract air).
    • Adjust the temperature settings if applicable.
    • Monitor the air quality indicators and adjust settings accordingly.
  • FAQ
    • Q: Can I install the SCHOOLAIR-D unit in any room?
    • A: The SCHOOLAIR-D unit is specifically designed for classrooms in schools. While it can be used in other rooms, it is recommended to consult the product documentation or contact our support team for guidance.
    • Q: Can I use the SCHOOLAIR-D unit without the optional control system?
    • A: Yes, the SCHOOLAIR-D unit can still function without the optional control system. However, some advanced features such as demand-based fresh air volume and automatic switching to secondary air mode will not be available.

INTRODUCTION

Type SCHOOLAIR-D

  • Supply and extract air unit with heat exchanger and heat recovery, secondary air option (based on air quality), for installation below the ceiling slab
  • Ready-to-operate decentralized ventilation unit that provides good comfort levels, used for the ventilation and extract ventilation of rooms such as classrooms in schools
  • Acoustically optimized EC fans with low specific fan powers, SFP-1 according to EN 13779
  • Plate heat exchanger for heat recovery (air/air), including bypass damper with electric actuator (open-close)
  • Heat exchanger for heating and cooling as 2-pipe or 4-pipe system
  • Reduction of fine dust and pollen contamination due to integral filters; F7 fresh air filter
  • The condensate drip tray is useful if the temperature temporarily falls below the dew point
  • Motorized shut-off dampers, normally closed (NC)
  • Installation without interruption to the operations of the respective school
  • Easy filter change, no tools required

Optional equipment and accessories

  • Modular control system FSL-CONTROL II, especially for decentralized ventilation systems
  • Demand-based fresh air volume, free cooling, and night purge, depending on the control strategy
  • Automatic switching to secondary air mode (based on air quality)

Variable heat recovery

  • Powder-coated RAL 9005 (black, casing) or RAL 9010 (white, cover)
  • For further product information please click here.