NEXO eLS18 18 Inch Passive Install Subwoofer User Manual

June 16, 2024
NEXO

NEXO eLS18 18 Inch Passive Install Subwoofer

Product Information

Specifications

  • Product Type: eLS18
  • Serial Number: DP6766-01a-DI
  • IP Rating: IP55

Description

The eLS18 is a compact and powerful subwoofer designed to complement the ePS10 and ePS12. It is equipped with 2 pairs of screw terminal blocks for easy wiring. The permissible cable size ranges from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) with a maximum outside diameter of 11mm.

To wire the eLS18, slit the membrane of the grommet crosswise, pass the cable through, and make the connection to the screw terminals. Place the IPCOV correctly to ensure IP55 protection.

Warnings and Precautions

Warnings:

  • Select screws and mounting location supporting 4 times the system weight.
  • Do not expose the system to excessive dust, vibrations, extreme cold or hot temperatures to avoid damaging components.
  • Do not place the system in an unstable position to prevent accidental falls.
  • If the system is used on a tripod, ensure the tripod’s specifications are adapted and that its height does not exceed 1.40m/55. Do not move the tripod with the system in position.

Safety Informations:

  • Unplug connected cables before moving the system.
  • Power off the system before connecting or disconnecting any cables.
  • When switching on the installation, power on the amplifier last. When switching off the installation, shut off the amplifier first.
  • If you work in cold temperatures, gradually raise the level to the nominal value during the first few minutes of use to allow system components to stabilize.
  • Regularly check the system condition.

High Sound Pressure Levels

Exposure to very high sound pressure levels may cause permanent hearing loss. The OSHA (Occupational Safety and Health Administration) American Agency specifies the following maximal exposures:

Number of Hours Sound Pressure Level (dBA), Slow Response
90 92
95 97
100 102
105 110

115

Equipment

The eLS18 is equipped with the following:

  • Two M10 fittings on each side of the cabinet for connecting accessories (VNI-VCPL535, VNI-HCPL600, VNU-HBRK600, eye-bolts).
  • Two pairs (In/Out) of 7.62 mm pitch screw terminal blocks for easy cable connections. The permissible cable size ranges from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) copper section.

Compatibility

The eLS18 is compatible with the following systems:

System Compatibility
ePS10 1 per bridged channels, up to 2 per channel
ePS12 1 per bridged channels, up to 2 per channel
eLS18 1 per bridged channels, 2 per bridged channels
NXAMP4X2mk2 Up to 4 per channel

Product Usage Instructions

Wiring the eLS18

To wire the eLS18, follow these steps:

  1. Slit the membrane of the grommet crosswise.
  2. Pass the cable through the grommet.
  3. Make the connection to the screw terminals.
  4. Place the IPCOV correctly for IP55 protection.

Mounting the eLS18

When mounting the eLS18, ensure that the screws and mounting location can support at least 4 times the weight of the system. Avoid exposing the system to excessive dust, vibrations, extreme cold or hot temperatures. Place the system in a stable position to prevent accidental falls. If using a tripod, make sure its specifications are suitable and the height does not exceed 1.40m/55. Do not move the tripod with the system in position.

Powering the eLS18

Follow these precautions when connecting and powering the eLS18:

  • Unplug connected cables before moving the system.
  • Power off the system before connecting or disconnecting any cables.
  • When switching on the installation, power on the amplifier last. When switching off the installation, shut off the amplifier first.
  • If working in cold temperatures, gradually raise the level to the nominal value during the first few minutes of use to allow system components to stabilize.
  • Regularly check the system condition.

FAQ

Q: What is the IP rating of the eLS18?

A: The eLS18 has an IP55 rating.

Q: What is the maximum cable size that can be used with the eLS18?

A: The permissible cable size ranges from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) copper section with a maximum outside diameter of 11mm.

EU Conformity declaration

WARNINGS PRECAUTIONS

  • Do not open the speaker, do not try to disassemble it neither to modify it in any way. The system doesn’t include any user-repairable part.
  • If the system seems to be malfunctioning or damaged, stop using it at once and have it repaired by a NEXO qualified technician.
  • Do not expose the system directly to the sun or to the rain, do not immerse it into fluids, do not place objects filled with liquid on the system. If a liquid gets into the system, please have it inspected by a NEXO qualified technician.
  • When flying outdoor systems ensure that the system is not exposed to excessive wind or snow loads and is protected from rainfall.
  • In case of wind greater than 8 on Beaufort scale (72km/h – 45mph), a touring system has to be landed or an additional securing has to be implanted.
  • For fixed installations, wind loading has to be taken into account in accordance to the national standards
  • The connection should be performed by qualified technician, by ensuring that power is off.
  • Operating temperature with temperate climate: 0°C to +40°C (+32°F to +104); -20°C à +60°C (-4°F to +140°F) for storage.

SAFETY INFORMATION

  • Read this manual before using the speaker.
  • Keep this manual available for further reference.
  • Observe all warnings and cautions.
  • Please check the NEXO Web site nexo-sa.com to get the most up-to-date version of this manual.
  • Ensure you are aware of the safety rules applying to rigging, stacking or installing on tripod or speaker stand. Failure to observe these rules may expose persons to potential wounds or even death.
  • Only use the system with accessories specified by NEXO.
  • Please always consult a NEXO-accredited technician if the installation needs architectural works and observe following precautions:

Mounting Precautions:

  • Please select screws and mounting location supporting 4 times the system weight.
  • Do not expose the system to excessive dust, vibrations, to extreme cold or hot temperatures, to reduce the risk of damaging components.
  • Do not place the system in an unstable position: it could fall accidentally.
  • If the system is used on a tripod, please ensure the tripod’s specifications are adapted and that its height does not exceed 1.40m/55”. Do not move the tripod with the system in position.

Connection and Powering Precautions:

  • Unplug connected cables before moving the system.
  • Power off the system before connecting the system.
  • When switching on the installation, the amplifier must be powered last; when switching the installation off, shut off the amplifier first.
  • If you work by cold temperatures, progressively raise the level to nominal value during the first minutes of use, to allow the system components to stabilize.
    Please check regularly the system condition.

HIGH SOUND PRESSURE LEVELS
Exposure to very high sound pressure levels may cause permanent hearing losses. Degrees of hearing losses may be different from one person to another, but almost everybody will be affected if exposed to high sound pressure levels during a long period of time. The OSHA (Occupational Safety and Health Administration) American Agency specified the following maximal exposures:

Number of Hours

| Sound Pressure Level (dBA), Slow Response
---|---
8| 90
6| 92
4| 95
3| 97
2| 100
1 ½| 102
1| 105
½| 110
¼ or less| 115

WASTE OF ELECTRIC OR ELECTRONIC EQUIPMENT
This symbol on the product or its packaging indicates that this product must not be treated as household waste. Instead, it is your responsibility to hand it over to a designated collection point for the recycling of waste electrical and electronic equipment. By ensuring your waste equipment is recycled, you will help prevent potential negative consequences for the environment and human health, which could appear if this product was not recycled. Recycling helps spare natural resources. For more information about the recycling of this product, please contact your local city office, your household waste disposal service or your reseller.

EQUIPMENT

On the four sides of the cabinet, two M10 fittings will connect the eLS18 to accessories.
(VNI-VCPL535, VNI-HCPL600, VNU-HBRK600, eye-bolts).
2 pairs (In/Out) of 7.62 mm pitch screw terminal blocks. Cables from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) copper section.

DESCRIPTION

  • eLS18 is a compact and powerful subwoofer, ideal complementing ePS10 and ePS12.

  • eLS18 is equipped with 2 pairs (In/Out) of screw terminal blocks, permissible cables from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) copper section. Cable with maximum outside diameter of 11mm.

  • To wire eLS18, slit the membrane of the grommet crosswise, pass the cable through and make the connection to the screw terminals. Place the IPCOV.

  • IP55: be careful to place the IPCOV correctly.

  • Amplification

  • The eLS18 speakers must be used with a NEXO processor to handle EQ, phase alignment, crossover, and excursion/thermal protection for the system loudspeaker.

  • The following table shows the number of ePS speakers and eLS18 subwoofers usable with each solution.

 |       DTD + DTDAMP4X0.7| DTD + DTDAMP4X1.3 **| NXAMP4X1mk2 **| NXAMP4X2mk2 **| NXAMP4X4mk2 **
---|---|---|---|---|---
ePS10| 1 per bridged channels| Up to 2 per channel| 1 per channel | Up to 4 per channel| Up to 4 per channel
ePS12| 1 per bridged channels| Up to 2 per channel| 1 per channel
| Up to 4 per channel| Up to 4 per channel
eLS18| 1 per bridged channels| 1 per bridged channels| 2 per bridged channels| 1 per channel *| Up to 4 per channel

PRESET

Please consult nexo-sa.com for NEXO TD Controllers firmware information.

For a traditional use of the subwoofer, there are 3 setups for eLS18:

  • 32 Hz – 85 Hz
  • 32 Hz – 120 Hz
  • 32 Hz – 150 Hz

eLS18 + ePS10

eLS18 + ePS12

ACCESSORIES

WARNINGS

  • All accessories are specifically rated in agreement with structural computations.
  • Never use other accessories when assembling eLS cabinets than the ones provided by NEXO: NEXO will decline responsibility if any component is purchased from different supplier.
  • PROHIBITED: ePS10 or ePS12 below eLS18 without dedicated accessory

VNU-HBRK600

  • Horizontal Cradle, can be used with VNI-CLADAPT.
  • VNU-HBRK600 (1 position).
  • Remove the M10 inserts from each side.
  • Place HBRK600 on eLS18, use only
  • fasteners provided.
  • Tight properly.
  • Refer to the Product Data Sheet

VNI-CLADAPT
Ceiling Adapter, use with VNI-HBRK600.
Screw VNI-CLADAPT to the ceiling (fasteners not provided).
Place the assembly on VNI-CLADAPT, use the 2 guides. Tight with the fasteners provided with VNI-CLADAPT.
Refer to the Product Data Sheet

ACCESSORIES
Page 8 / 14 eLS18 VNI-VCPL535
Coupler ePS10 under Vertical eLS18 Refer to the Product Data Sheet

VNI-HCPL600
Coupler ePS12 under Horizontal eLS18
Refer to the Product Data Sheet

ARRAY EQ

The ArrayEQ allows to adjust the system frequency response in its lower range (see curves below, with different ArrayEq values):

MAINTENANCE

NOTE:
Speakers and Grills can be sent back to NEXO for recycling

Driver access
Loosen the 4 screws, Remove the grille.
Tightening torque: 2.5Nm

Remove 8 screws.
Tightening torque: 3.5Nm (Thread Locker: Loctite 242)

Spare parts

MARK QUANTITY REFERENCE DESIGNATION
1 1 05ELS18-UA eLS18 Complete grille Black
2 1 05EBELS18 eLS18 Empty cabinet Black
3 8 05VXTSTHC1012 HEADLESS Screw M10x12 Black (x10)
4 1 05HP18122-8     peaker 1 ”  hms
  1 05HP18122-8R/K Recone Kit for HP18122-8
5 1 05LOGNEXO6 NEXO Logo (with 2x starlock)
6 2 05PASF-DG9E1 Grommet DG11 Ø15.5mm (x2)

TECHNICAL SPECIFICATIONS

WITH NEXO ELECTRONICS

Model eLS18
Frequency range (±6dB) 32 Hz – 150 Hz
Sensivity 1W@1m 106 dB SPL Nominal
Peak SPL Level (1m) 138dB Peak
Operating voltage 55 Vrms
Crossover Frequency 32 – 85 Hz; 32 – 120 Hz; 32 – 150 Hz
Nominal Impedance 8 ohms

SPECIFICATIONS

NEXO S.A.
arc d’activité de la Dame Jeanne
F-60128 PLAILLY

Tel: +33 3 44 99 00 70
Fax: +33 3 44 99 00 30
E-mail: info@nexo.fr
nexo-sa.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals