NEXO eLS18 18 Inch Passive Install Subwoofer
Product Information
Specifications
- Product Type: eLS18
- Serial Number: DP6766-01a-DI
- IP Rating: IP55
Description
The eLS18 is a compact and powerful subwoofer designed to complement the ePS10 and ePS12. It is equipped with 2 pairs of screw terminal blocks for easy wiring. The permissible cable size ranges from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) with a maximum outside diameter of 11mm.
To wire the eLS18, slit the membrane of the grommet crosswise, pass the cable through, and make the connection to the screw terminals. Place the IPCOV correctly to ensure IP55 protection.
Warnings and Precautions
Warnings:
- Select screws and mounting location supporting 4 times the system weight.
- Do not expose the system to excessive dust, vibrations, extreme cold or hot temperatures to avoid damaging components.
- Do not place the system in an unstable position to prevent accidental falls.
- If the system is used on a tripod, ensure the tripod’s specifications are adapted and that its height does not exceed 1.40m/55. Do not move the tripod with the system in position.
Safety Informations:
- Unplug connected cables before moving the system.
- Power off the system before connecting or disconnecting any cables.
- When switching on the installation, power on the amplifier last. When switching off the installation, shut off the amplifier first.
- If you work in cold temperatures, gradually raise the level to the nominal value during the first few minutes of use to allow system components to stabilize.
- Regularly check the system condition.
High Sound Pressure Levels
Exposure to very high sound pressure levels may cause permanent hearing loss. The OSHA (Occupational Safety and Health Administration) American Agency specifies the following maximal exposures:
Number of Hours | Sound Pressure Level (dBA), Slow Response |
---|---|
90 | 92 |
95 | 97 |
100 | 102 |
105 | 110 |
115
Equipment
The eLS18 is equipped with the following:
- Two M10 fittings on each side of the cabinet for connecting accessories (VNI-VCPL535, VNI-HCPL600, VNU-HBRK600, eye-bolts).
- Two pairs (In/Out) of 7.62 mm pitch screw terminal blocks for easy cable connections. The permissible cable size ranges from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) copper section.
Compatibility
The eLS18 is compatible with the following systems:
System | Compatibility |
---|---|
ePS10 | 1 per bridged channels, up to 2 per channel |
ePS12 | 1 per bridged channels, up to 2 per channel |
eLS18 | 1 per bridged channels, 2 per bridged channels |
NXAMP4X2mk2 | Up to 4 per channel |
Product Usage Instructions
Wiring the eLS18
To wire the eLS18, follow these steps:
- Slit the membrane of the grommet crosswise.
- Pass the cable through the grommet.
- Make the connection to the screw terminals.
- Place the IPCOV correctly for IP55 protection.
Mounting the eLS18
When mounting the eLS18, ensure that the screws and mounting location can support at least 4 times the weight of the system. Avoid exposing the system to excessive dust, vibrations, extreme cold or hot temperatures. Place the system in a stable position to prevent accidental falls. If using a tripod, make sure its specifications are suitable and the height does not exceed 1.40m/55. Do not move the tripod with the system in position.
Powering the eLS18
Follow these precautions when connecting and powering the eLS18:
- Unplug connected cables before moving the system.
- Power off the system before connecting or disconnecting any cables.
- When switching on the installation, power on the amplifier last. When switching off the installation, shut off the amplifier first.
- If working in cold temperatures, gradually raise the level to the nominal value during the first few minutes of use to allow system components to stabilize.
- Regularly check the system condition.
FAQ
Q: What is the IP rating of the eLS18?
A: The eLS18 has an IP55 rating.
Q: What is the maximum cable size that can be used with the eLS18?
A: The permissible cable size ranges from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) copper section with a maximum outside diameter of 11mm.
EU Conformity declaration
WARNINGS PRECAUTIONS
- Do not open the speaker, do not try to disassemble it neither to modify it in any way. The system doesn’t include any user-repairable part.
- If the system seems to be malfunctioning or damaged, stop using it at once and have it repaired by a NEXO qualified technician.
- Do not expose the system directly to the sun or to the rain, do not immerse it into fluids, do not place objects filled with liquid on the system. If a liquid gets into the system, please have it inspected by a NEXO qualified technician.
- When flying outdoor systems ensure that the system is not exposed to excessive wind or snow loads and is protected from rainfall.
- In case of wind greater than 8 on Beaufort scale (72km/h – 45mph), a touring system has to be landed or an additional securing has to be implanted.
- For fixed installations, wind loading has to be taken into account in accordance to the national standards
- The connection should be performed by qualified technician, by ensuring that power is off.
- Operating temperature with temperate climate: 0°C to +40°C (+32°F to +104); -20°C à +60°C (-4°F to +140°F) for storage.
SAFETY INFORMATION
- Read this manual before using the speaker.
- Keep this manual available for further reference.
- Observe all warnings and cautions.
- Please check the NEXO Web site nexo-sa.com to get the most up-to-date version of this manual.
- Ensure you are aware of the safety rules applying to rigging, stacking or installing on tripod or speaker stand. Failure to observe these rules may expose persons to potential wounds or even death.
- Only use the system with accessories specified by NEXO.
- Please always consult a NEXO-accredited technician if the installation needs architectural works and observe following precautions:
Mounting Precautions:
- Please select screws and mounting location supporting 4 times the system weight.
- Do not expose the system to excessive dust, vibrations, to extreme cold or hot temperatures, to reduce the risk of damaging components.
- Do not place the system in an unstable position: it could fall accidentally.
- If the system is used on a tripod, please ensure the tripod’s specifications are adapted and that its height does not exceed 1.40m/55”. Do not move the tripod with the system in position.
Connection and Powering Precautions:
- Unplug connected cables before moving the system.
- Power off the system before connecting the system.
- When switching on the installation, the amplifier must be powered last; when switching the installation off, shut off the amplifier first.
- If you work by cold temperatures, progressively raise the level to nominal value during the first minutes of use, to allow the system components to stabilize.
Please check regularly the system condition.
HIGH SOUND PRESSURE LEVELS
Exposure to very high sound pressure levels may cause permanent hearing
losses. Degrees of hearing losses may be different from one person to another,
but almost everybody will be affected if exposed to high sound pressure levels
during a long period of time. The OSHA (Occupational Safety and Health
Administration) American Agency specified the following maximal exposures:
Number of Hours
| Sound Pressure Level (dBA), Slow Response
---|---
8| 90
6| 92
4| 95
3| 97
2| 100
1 ½| 102
1| 105
½| 110
¼ or less| 115
WASTE OF ELECTRIC OR ELECTRONIC EQUIPMENT
This symbol on the product or its packaging indicates that this product must
not be treated as household waste. Instead, it is your responsibility to hand
it over to a designated collection point for the recycling of waste electrical
and electronic equipment. By ensuring your waste equipment is recycled, you
will help prevent potential negative consequences for the environment and
human health, which could appear if this product was not recycled. Recycling
helps spare natural resources. For more information about the recycling of
this product, please contact your local city office, your household waste
disposal service or your reseller.
EQUIPMENT
On the four sides of the cabinet, two M10 fittings will connect the eLS18 to
accessories.
(VNI-VCPL535, VNI-HCPL600, VNU-HBRK600, eye-bolts).
2 pairs (In/Out) of 7.62 mm pitch screw terminal blocks. Cables from 0.75 mm2
to 3.31 mm2 (12 to 15 AWG) copper section.
DESCRIPTION
-
eLS18 is a compact and powerful subwoofer, ideal complementing ePS10 and ePS12.
-
eLS18 is equipped with 2 pairs (In/Out) of screw terminal blocks, permissible cables from 0.75 mm2 to 3.31 mm2 (12 to 15 AWG) copper section. Cable with maximum outside diameter of 11mm.
-
To wire eLS18, slit the membrane of the grommet crosswise, pass the cable through and make the connection to the screw terminals. Place the IPCOV.
-
IP55: be careful to place the IPCOV correctly.
-
Amplification
-
The eLS18 speakers must be used with a NEXO processor to handle EQ, phase alignment, crossover, and excursion/thermal protection for the system loudspeaker.
-
The following table shows the number of ePS speakers and eLS18 subwoofers usable with each solution.
| DTD + DTDAMP4X0.7| DTD + DTDAMP4X1.3 **|
NXAMP4X1mk2 **| NXAMP4X2mk2 **| NXAMP4X4mk2 **
---|---|---|---|---|---
ePS10| 1 per bridged channels| Up to 2 per channel| 1 per channel | Up to 4
per channel| Up to 4 per channel
ePS12| 1 per bridged channels| Up to 2 per channel| 1 per channel | Up to 4
per channel| Up to 4 per channel
eLS18| 1 per bridged channels| 1 per bridged channels| 2 per bridged channels|
1 per channel *| Up to 4 per channel
PRESET
Please consult nexo-sa.com for NEXO TD Controllers firmware information.
For a traditional use of the subwoofer, there are 3 setups for eLS18:
- 32 Hz – 85 Hz
- 32 Hz – 120 Hz
- 32 Hz – 150 Hz
eLS18 + ePS10
eLS18 + ePS12
ACCESSORIES
WARNINGS
- All accessories are specifically rated in agreement with structural computations.
- Never use other accessories when assembling eLS cabinets than the ones provided by NEXO: NEXO will decline responsibility if any component is purchased from different supplier.
- PROHIBITED: ePS10 or ePS12 below eLS18 without dedicated accessory
VNU-HBRK600
- Horizontal Cradle, can be used with VNI-CLADAPT.
- VNU-HBRK600 (1 position).
- Remove the M10 inserts from each side.
- Place HBRK600 on eLS18, use only
- fasteners provided.
- Tight properly.
- Refer to the Product Data Sheet
VNI-CLADAPT
Ceiling Adapter, use with VNI-HBRK600.
Screw VNI-CLADAPT to the ceiling (fasteners not provided).
Place the assembly on VNI-CLADAPT, use the 2 guides. Tight with the fasteners
provided with VNI-CLADAPT.
Refer to the Product Data Sheet
ACCESSORIES
Page 8 / 14 eLS18 VNI-VCPL535
Coupler ePS10 under Vertical eLS18 Refer to the Product Data Sheet
VNI-HCPL600
Coupler ePS12 under Horizontal eLS18
Refer to the Product Data Sheet
ARRAY EQ
The ArrayEQ allows to adjust the system frequency response in its lower range (see curves below, with different ArrayEq values):
MAINTENANCE
NOTE:
Speakers and Grills can be sent back to NEXO for recycling
Driver access
Loosen the 4 screws, Remove the grille.
Tightening torque: 2.5Nm
Remove 8 screws.
Tightening torque: 3.5Nm (Thread Locker: Loctite 242)
Spare parts
MARK | QUANTITY | REFERENCE | DESIGNATION |
---|---|---|---|
1 | 1 | 05ELS18-UA | eLS18 Complete grille Black |
2 | 1 | 05EBELS18 | eLS18 Empty cabinet Black |
3 | 8 | 05VXTSTHC1012 | HEADLESS Screw M10x12 Black (x10) |
4 | 1 | 05HP18122-8 | peaker 1 ” hms |
1 | 05HP18122-8R/K | Recone Kit for HP18122-8 | |
5 | 1 | 05LOGNEXO6 | NEXO Logo (with 2x starlock) |
6 | 2 | 05PASF-DG9E1 | Grommet DG11 Ø15.5mm (x2) |
TECHNICAL SPECIFICATIONS
WITH NEXO ELECTRONICS
Model | eLS18 |
---|---|
Frequency range (±6dB) | 32 Hz – 150 Hz |
Sensivity 1W@1m | 106 dB SPL Nominal |
Peak SPL Level (1m) | 138dB Peak |
Operating voltage | 55 Vrms |
Crossover Frequency | 32 – 85 Hz; 32 – 120 Hz; 32 – 150 Hz |
Nominal Impedance | 8 ohms |
SPECIFICATIONS
NEXO S.A.
arc d’activité de la Dame Jeanne
F-60128 PLAILLY
Tel: +33 3 44 99 00 70
Fax: +33 3 44 99 00 30
E-mail: info@nexo.fr
nexo-sa.com
References
Read User Manual Online (PDF format)