Literature Library FG7T Two Stage Variable Speed High Efficiency Upflow Horizontal and Downflow Gas Furnace Owner’s Manual
- June 15, 2024
- Literature Library
Table of Contents
- FG7T (A and K Series) ISEER, Smartlite®
- GAS FURNACE COMPONENTS
- DIMENSIONS
- | 0| 0| 0| 1000| 74| 1000| 89
- | 0| 0| 1| 1115| 66| 1115| 80
- | 0| 1| 0| 1230| 60| 1230| 72
- | 0| 1| 1| 1345| 55| 1345| 66
- | 1| 0| 0| 1460| 51| 1460| 61
- | 1| 0| 1| 1575| 47| 1575| 56
- | 1| 1| 0| 1690| 44| 1690| 53
- | 1| 1| 1| 1805| 41| 1805| 49
- Switch not used – can be 0 or 1
- COOLING AIRFLOWS
- MODEL IDENTIFICATION CODE
- Switch not used – can be 0 or 1
- SPECIFICATIONS
- ACCESSORIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TECHNICAL
SPECIFICATIONS
FG7T (A and K Series) ISEER, Smartlite®
Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas
Furnaces
Induced Draft – 80+ AFUE Input 60,000 – 140,000 Btuh
The high efficiency gas furnace may be installed free standing in a utility
room, basement, or enclosed in an alcove or closet. The rounded corner jacket
provides a pleasing “appliance appearance.” Design certified by CSA for
application in Canada and the United States. FEATURES and BENEFITS
- ISEER:Energy efficientbrushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling.
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
- LowBoy Height: Easy to applyin low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
- 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
- 30 second post purge: Increases life of heat exchanger.
- Two Stage Inducer: Optimizes efficiency on first stage heat and reduces sound levels.
- Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology.
- Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- Highstatic blowers: Allmodels equipped with high static blowers.
- 90 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a NORDYNE coil.
- Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
- LPconvertible: Simple burner orifice and regulator spring change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy torecognize states without counting flashes.
- Integrated control board: Incorporates connections for electronic air cleaner, humidifier and twinning.
- Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
- Blower Compartment: Insulated for ultra quiet operation.
GAS FURNACE COMPONENTS
ITEM | COMPONENT NAME |
---|---|
1. | Blower Assembly |
2. | Blower Door Switch |
3. | Burner Assembly |
4. | Flame Roll-Out Switch |
5. | Flame Sensor |
6. | Furnace Control Board |
7. | Gas Manifold |
8. | Gas Valve |
9. | Igniter |
10. | Inducer Assembly |
11. | Main Air Limit Switch |
12. | Motor Choke (C and D cabinets only) |
13. | Motor Control Board |
14. | Motor Control Box |
15. | Pressure Switches |
16. | Transformer |
Upflow/Horizontal Gas Furnace
ITEM | COMPONENT NAME |
---|---|
1. | Blower Assembly |
2′ | Blower Door Switch (behind blower panel) |
3. | Burner Assembly |
4. | Combustion Tube |
5. | Flame Roll-Out Switch |
6. | Flame Sensor |
7. | Furnace Control Board |
8. | Gas Manifold |
9. | Gas Valve |
10. | Igniter |
11. | Inducer Assembly |
12. | Main Air Limit Switch |
13. | Motor Choke (C and D cabinets only) |
14. | Motor Control Board |
15. | Pressure Switches |
16. | Transformer |
Downflow Gas Furnace
DIMENSIONS
*TA 80+ Upflow Furnace
*TA
Model’s| Dim.
“A”| Dim.
“B”| Dim.
“C”| Dim.
“D”
---|---|---|---|---
‘A’ CABINET| 14 1/4| 10 3/4| 12 5/8| 12 7/8
‘B’ CABINET| 17 1/2| 11 3/4| 15 7/8| 16 1/8
‘C’ CABINET| 21| 14| 19 3/8| 19 7/8
‘D’ CABINET| 24 1/2| 15 1/4| 22 7/8| 23 1/8
NOTES:
$IMENSIONS SHOWN IN )NCHES.
*TK 80+ Downflow Furnace
*TK
Model’s| Dim.
“A”| Dim.
“B”| Dim.
“C”| Dim.
“D”
---|---|---|---|---
‘A’ Cabinet| 14 1/4| 10 3/4| 12 5/8| 12 7/8
‘B’ Cabinet| 17 1/2| 11 3/4| 15 7/8| 16 1/8
‘C’ Cabinet| 21| 14| 19 3/8| 19 5/8
‘D’ Cabinet| 24 1/2| 15 1/4| 22 7/8| 23 1/8
NOTES:
Dimensions shown in Inches.
BLOWER PERFORMANCE – FG7TA/TK
Nominal Heating Airflows (CFM) and Temperature Rise (°F)
A Cabinet | *TA/TK-060( )-VA Models |
---|---|
3WITCH 3ETTINGS HEAT | INPUT (BTU) 60000 |
A/B 2 3 4 | CFM |
0 | 0 |
0 | 0 |
0 | 0 |
0 | 0 |
0 | 1 |
0 | 1 |
0 | 1 |
0 | 1 |
B Cabinet | *TA/TK-080( )-VB Models |
--- | --- |
SWITCH SETTINGS HEAT | INPUT (BTU) 80000 |
A/B 2 3 4 | CFM |
1 | 0 |
1 | 0 |
1 | 0 |
1 | 0 |
1 | 1 |
1 | 1 |
1 | 1 |
1 | 1 |
C Cabinet | *TA/TK-100( )-VC Models |
Models
---|---|---
SWITCH SETTINGS HEAT| INPUT (B45) 100000| INPUT (BTU) 120000
A/B 2 3 4| CFM| TEMP RISE ( °F)| **** CFM| TEMP RISE ( °F)
| 0| 0| 0| 1000| 74| 1000| 89
| 0| 0| 1| 1115| 66| 1115| 80
| 0| 1| 0| 1230| 60| 1230| 72
| 0| 1| 1| 1345| 55| 1345| 66
| 1| 0| 0| 1460| 51| 1460| 61
| 1| 0| 1| 1575| 47| 1575| 56
| 1| 1| 0| 1690| 44| 1690| 53
| 1| 1| 1| 1805| 41| 1805| 49
D Cabinet | *TA-140( )-VD Model |
---|---|
SWITCH SETTINGS HEAT | INPUT (B45) 140000 |
A/B 2 3 4 | CFM |
# | 0 |
# | 0 |
# | 0 |
# | 0 |
# | 1 |
# | 1 |
# | 1 |
# | 1 |
Switch not used – can be 0 or 1
Notes:
- Two openings are recommended for airflows above 1600 CFM f the fiter(s) is (are) adjacent to the fumace.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.
COOLING AIRFLOWS
MODEL IDENTIFICATION CODE
Switch not used – can be 0 or 1
SPECIFICATIONS
FG7TA/TK MODEL NUMBERS| 060-VA| 080-VB| 100-VC|
120-VC| *140-VD
---|---|---|---|---|---
INPUT – BTUH (A)| 60,000 / 39,000| 80,000 / 52,000| 100,000 / 65,000| 120,000
/ 78,000| 140,000 / 91,000
(EATING CAPACITY – BTUH| 48,000 / 31,200| 64,000 / 41,600| 80,000 / 52,000|
96,000 / 62,400| 112,000 / 72,800
AFUE**| 80.0| 80.0| 80.0| 80.0| 80.0
BLOWER $ X 7| 10 X 6| 11 X 8| 11 X 10| 11 X 10| 11 X 10
MOTOR (.0. – 3PEED – 4YPE| 1/2 – 6ARIABLE| 1/2 – 6ARIABLE| 3/4 – 6ARIABLE| 3/4
– 6ARIABLE| 1 – 6ARIABLE
MOTOR &LA| 6.2| 6.2| 8.7| 8.7| 11.7
2ATED EXT. 30 – )N. 7.C.| 0.5| 0.5| 0.5| 0.5| 0.5
4EMPERATURE 2ISE 2ANGE – Ž&| 25-55| 30-60| 35-65| 35-65| 40-70
3HIPPING 7EIGHTS| 115LBS| 110LBS| 125LBS| 135LBS| 155LBS
“Canbe CorN
ACCESSORIES
FG7TA/TK KITS
Description| SKU
“B”, “C”, “$” CABINET DOWNflOW SUB BASE KIT| 904911
5.3. L0 CONVERSION KIT (0 TO 10,000 FT.)| 904914
CANADA L0 CONVERSION KIT (0 TO 4,500 FT.)| 904915
BOTTOM RETURN fiLTER 20 PER BOX, “A” CABINET| 903088
BOTTOM RETURN fiLTER 20 PER BOX, “B” CABINET| 904916
BOTTOM RETURN fiLTER 20 PER BOX, “C” CABINET| 904917
BOTTOM RETURN fiLTER 20 PER BOX, “$” CABINET| 904918
3IDE RETURN fiLTER KIT| 541036
All models are 115V, 60 HZ. Gas connections are 1/2″ N.PT.
AFUE= Annual Fuel Utilization Efficiency
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC LLC will furnish a replacement for any part of this product
which fails in normal use and service within the terms and conditions of the
warranty.
For complete details of the Limited Warranty, including applicable terms and
conditions, see your local installer or contact the Nortek Global HVAC LLC
warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency
information available from your retailer. Specifications and illustrations
subject to change without notice and without incurring obligations. Printed in
U.S.A (0 /2015)