Literature Library KG7T Two Stage Fixed Speed High Efficiency Upflow Horizontal and Downflow Gas Furnaces Owner’s Manual
- June 15, 2024
- Literature Library
Table of Contents
- FEATURES and BENEFITS
- GAS FURNACE COMPONENTS
- DIMENSIONS
- KG7TK 80+ High Efficiency Downflow SeriesBLOWER PERFORMANCE – KG7TA/TK
- ****
- Model Number
- Heating Input (Btuh)
- Motor Switch Setting
- External Static Pressure (in.w.c.)
- 0.1
- 0.2
- 0.3
- 0.4
- 0.5
- 0.6
- 0.7
- 0.8
- 1/5
- 2/6
- 3/7
- 4/8
- CFM
- Rise
- CFM
- Rise
- CFM
- Rise
- CFM
- Rise
- CFM
- Rise
- CFM
- Rise
- CFM
- Rise
- CFM
- Rise
- ****
- ****
- ****
- ****
- ****
- ****
- ****
- ****
- TA/TK-120(C)-C1
- ****
- ****
- ****
- ****
- ****
- ****
- ****
- ****
- 120000
- 0
- 0
- 0
- 0
- 1125
- –
- 1040
- 1
- 0
- 0
- 0
- 1205
- –
- 1120
- –
- 1040
- –
- 0
- 1
- 0
- 0
- 1305
- –
- 1225
- –
- 1150
- –
- 1070
- –
- 1
- 1
- 0
- 0
- 1430
- 62
- 1350
- –
- 1270
- –
- 1190
- –
- 1110
- –
- 1030
- –
- 0
- 0
- 1
- 0
- 1525
- 58
- 1450
- 61
- 1375
- 65
- 1300
- –
- 1225
- –
- 1150
- –
- 1075
- –
- 1000
- –
- 1
- 0
- 1
- 0
- 1620
- 55
- 1540
- 58
- 1465
- 61
- 1390
- 64
- 1315
- –
- 1240
- –
- 1165
- –
- 1090
- –
- 0
- 1
- 1
- 0
- 1695
- 52
- 1620
- 55
- 1545
- 58
- 1465
- 61
- 1390
- 64
- 1315
- –
- 1235
- –
- 1160
- –
- 1
- 1
- 1
- 0
- 1770
- 50
- 1700
- 52
- 1630
- 55
- 1555
- 57
- 1485
- 60
- 1410
- 63
- 1340
- 66
- 1265
- –
- 0
- 0
- 0
- 1
- 1875
- 47
- 1805
- 49
- 1730
- 51
- 1655
- 54
- 1580
- 56
- 1510
- 59
- 1435
- 62
- 1340
- 66
- 1
- 0
- 0
- 1
- 1905
- 47
- 1840
- 48
- 1775
- 50
- 1710
- 52
- 1640
- 54
- 1575
- 56
- 1510
- 59
- 1445
- 62
- 0
- 1
- 0
- 1
- 1980
- 45
- 1910
- 47
- 1845
- 48
- 1780
- 50
- 1715
- 52
- 1650
- 54
- 1580
- 56
- 1515
- 59
- 1
- 1
- 0
- 1
- 2025
- 44
- 1960
- 45
- 1895
- 47
- 1830
- 49
- 1765
- 50
- 1700
- 52
- 1635
- 54
- 1570
- 57
- 0
- 0
- 1
- 1
- 2085
- 43
- 2025
- 44
- 1960
- 45
- 1900
- 47
- 1840
- 48
- 1775
- 50
- 1715
- 52
- 1655
- 54
- 1
- 0
- 1
- 1
- 2135
- 42
- 2070
- 43
- 2010
- 44
- 1945
- 46
- 1880
- 47
- 1815
- 49
- 1750
- 51
- 1685
- 53
- 0
- 1
- 1
- 1
- 2200
- 40
- 2145
- 41
- 2090
- 43
- 2035
- 44
- 1980
- 45
- 1925
- 46
- 1870
- 48
- 1820
- 49
- 1
- 1
- 1
- 1
- 2280
- 39
- 2225
- 40
- 2170
- 41
- 2115
- 42
- 2065
- 43
- 2010
- 44
- 1955
- 45
- 1900
- 47
- ****
- ****
- ****
- ****
- ****
- ****
- ****
- ****
- TA/TK-140(C)-D1
- ****
- ****
- ****
- ****
- ****
- ****
- ****
- ****
- 140000
- 0
- 0
- 0
- 0
- 1395
- –
- 1350
- –
- 1305
- –
- 1260
- –
- 1210
- –
- 1165
- –
- 1
- 0
- 0
- 0
- 1465
- –
- 1420
- –
- 1375
- –
- 1330
- –
- 1290
- –
- 1245
- –
- 1200
- –
- 0
- 1
- 0
- 0
- 1555
- 67
- 1510
- 69
- 1470
- –
- 1425
- –
- 1380
- –
- 1340
- –
- 1295
- –
- 1250
- –
- 1
- 1
- 0
- 0
- 1625
- 64
- 1585
- 65
- 1540
- 67
- 1500
- 69
- 1460
- –
- 1415
- –
- 1375
- –
- 1335
- –
- 0
- 0
- 1
- 0
- 1690
- 61
- 1650
- 63
- 1610
- 64
- 1570
- 66
- 1530
- 68
- 1485
- 70
- 1445
- –
- 1405
- –
- 1
- 0
- 1
- 0
- 1760
- 59
- 1715
- 60
- 1670
- 62
- 1625
- 64
- 1575
- 66
- 1530
- 68
- 1485
- 70
- 1440
- –
- 0
- 1
- 1
- 0
- 1835
- 57
- 1790
- 58
- 1745
- 59
- 1695
- 61
- 1650
- 63
- 1605
- 65
- 1555
- 67
- 1510
- 69
- 1
- 1
- 1
- 0
- 1885
- 55
- 1840
- 56
- 1790
- 58
- 1745
- 59
- 1700
- 61
- 1655
- 63
- 1610
- 64
- 1565
- 66
- 0
- 0
- 0
- 1
- 1945
- 53
- 1900
- 55
- 1850
- 56
- 1805
- 57
- 1760
- 59
- 1710
- 61
- 1665
- 62
- 1620
- 64
- 1
- 0
- 0
- 1
- 1950
- 53
- 1905
- 54
- 1860
- 56
- 1820
- 57
- 1775
- 58
- 1735
- 60
- 1690
- 61
- 1650
- 63
- 0
- 1
- 0
- 1
- 2075
- 50
- 2030
- 51
- 1990
- 52
- 1945
- 53
- 1900
- 55
- 1855
- 56
- 1810
- 57
- 1770
- 59
- 1
- 1
- 0
- 1
- 2125
- 49
- 2085
- 50
- 2040
- 51
- 2000
- 52
- 1955
- 53
- 1910
- 54
- 1870
- 55
- 1825
- 57
- 0
- 0
- 1
- 1
- 2170
- 48
- 2130
- 49
- 2090
- 50
- 2045
- 51
- 2005
- 52
- 1965
- 53
- 1925
- 54
- 1880
- 55
- 1
- 0
- 1
- 1
- 2215
- 47
- 2180
- 48
- 2140
- 48
- 2105
- 49
- 2070
- 50
- 2035
- 51
- 2000
- 52
- 1965
- 53
- 0
- 1
- 1
- 1
- 2225
- 47
- 2165
- 48
- 2100
- 49
- 2040
- 51
- 1
- 1
- 1
- 1
- 2170
- 48
- 2120
- 49
- 2065
- 50
- MODEL IDENTIFICATION CODE
- SPECIFICATIONS
- ACCESSORIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**Literature Library KG7T Two Stage Fixed Speed High Efficiency Upflow Horizontal and Downflow Gas Furnaces Owner’s Manual
**
FEATURES and BENEFITS
-
100% fired and tested: All units and each component are tested on the manufacturing line. • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
-
Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
-
Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
-
30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
-
30 second post purge :Increases life of heat exchanger.
-
Hot surface ignitor : Innovative application of an appliance type ignitor with a 20 year history of reliability. Utilizes proven Smartlite® technology.
-
Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
-
High static blowers: All models equipped with high static blowers.
-
90 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
-
Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
-
Variable speed blower kit: Upgradable to full variable speed with kit.
-
Convertible : Simple burner orifice and regulator spring
change for ease of convertibility. -
Diagnostic lights for easy troubleshooting without counting lashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
-
Integrated control board: Incorporates connections for electronic air cleaner and humidifier.
-
Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
-
Energy Efficient Brushless DC (ECM) Motor: Gives up to 1 SEER point efficiency gain in cooling.
-
Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.
GAS FURNACE COMPONENTS
Upflow/Horizontal Gas Furnace
Downflow Gas Furnace
DIMENSIONS
GAS FURNACE COMPONENTSU pflow/Horizontal Gas Furnace Downflow Gas Furnace DIMENSIONS
*TA Model #’s| Dimension “A”| Dimension “B”| Dimension
“C”| Dimension “D”
---|---|---|---|---
060-23A1| 14 1/4| 10 3/4| 12 5/8| 12 7/8
080-24B1| 17 1/2| 11 3/4| 15 7/8| 16 1/8
100-24B1
100-35C1| 21| 14| 19 3/8| 19 5/8
120-35C1
140-45D1| 24 1/2| 15 1/4| 22 7/8| 23 1/8
KG7TA 80+ High Efficiency Upflow/Horizontal Series
*TK Model #’s| Dimension “A”| Dimension “B”| Dimension
“C”| Dimension “D”
---|---|---|---|---
060-23A1| 14 1/4| 10 3/4| 12 5/8| 12 7/8
080-24B1| 17 1/2| 11 3/4| 15 7/8| 16 1/8
100-24B1
100-35C1| 21| 14| 19 3/8| 19 5/8
120-35C1
140-45D1| 24 1/2| 15 1/4| 22 7/8| 23 1/8
KG7TK 80+ High Efficiency Downflow SeriesBLOWER PERFORMANCE – KG7TA/TK
G7TA/TK – 80% AFUE, Two Stage Gas Furnace
**Model Number| ****Heating Input (Btuh)| Motor Switch
Setting| External Static Pressure (in.w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
1/5| 2/6| 3/7| 4/8| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise| CFM| Rise| CFM| Rise
***TA/TK-060(C)-*A1|
**60000| 0| 0| 0| 0| | | | | | | | | | | |
| | | |
1| 0| 0| 0| | | | | | | | | | | | | | | |
0| 1| 0| 0| 600| –| 555| –| 510| | | | | | | | | | |
1| 1| 0| 0| 705| –| 670| –| 635| –| 600| –| | | | | | | |
0| 0| 1| 0| 775| 57| 740| 60| 705| –| 665| –| | | | | | | |
1| 0| 1| 0| 900| 49| 870| 51| 835| 53| 800| 56| 765| 58| 730| 61| 695| 64|
660| 67
0| 1| 1| 0| 950| 47| 920| 48| 890| 50| 855| 52| 825| 54| 795| 56| 765| 58|
730| 61
1| 1| 1| 0| 1000| 44| 970| 46| 940| 47| 910| 49| 880| 51| 850| 52| 820| 54|
790| 56
0| 0| 0| 1| 1075| 41| 1045| 43| 1015| 44| 985| 45| 960| 46| 925| 48| 900| 49|
870| 51
1| 0| 0| 1| 1110| 40| 1080| 41| 1055| 42| 1025| 43| 1000| 44| 975| 46| 945|
47| 920| 48
0| 1| 0| 1| 1170| 38| 1140| 39| 1115| 40| 1090| 41| 1060| 42| 1035| 43| 1010|
44| 985| 45
1| 1| 0| 1| 1210| 37| 1185| 38| 1160| 38| 1130| 39| 1105| 40| 1080| 41| 1055|
42| 1025| 43
0| 0| 1| 1| 1520| 29| 1225| 36| 1200| 37| 1175| 38| 1150| 39| 1120| 40| 1095|
41| 1070| 42
1| 0| 1| 1| 1305| 34| 1280| 35| 1255| 35| 1230| 36| 1205| 37| 1180| 38| 1155|
38| 1130| 39
0| 1| 1| 1| 1350| 33| 1230| 36| 1305| 34| 1285| 35| 1260| 35| 1240| 36| 1215|
37| 1195| 37
1| 1| 1| 1| 1440| 31| 1400| 32| 1365| 33| 1230| 36| 1295| 36| 1255| 35| 1220|
36| 1185| 38
***TA/TK-080(C)-*B1|
**80000**| 0| 0| 0| 0| | | | | | | | | | | |
| | | |
1| 0| 0| 0| | | | | | | | | | | | | | | |
0| 1| 0| 0| | | | | | | | | | | | | | | |
1| 1| 0| 0| 725| –| | | | | | | | | | | | | |
0| 0| 1| 0| 810| –| | | | | | | | | | | | | |
1| 0| 1| 0| 940| –| 890| –| 845| –| 795| –| 750| –| 700| –| | | |
0| 1| 1| 0| 990| 60| 945| –| 905| –| 860| –| 820| –| 775| –| 735| –| 690| –
1| 1| 1| 0| 1055| 56| 1015| 58| 970| –| 930| –| 890| –| 845| –| 805| –| 760| –
0| 0| 0| 1| 1135| 52| 1095| 54| 1055| 56| 1010| 59| 960| –| 930| –| 890| –|
850| –
1| 0| 0| 1| 1185| 50| 1145| 52| 1105| 54| 1065| 56| 1030| 58| 990| 60| 950| –|
910| –
0| 1| 0| 1| 1250| 47| 1210| 49| 1170| 51| 1135| 52| 1095| 54| 1055| 56| 1020|
58| 980| 60
1| 1| 0| 1| 1290| 46| 1255| 47| 1220| 49| 1180| 50| 1145| 52| 1110| 53| 1075|
55| 1040| 57
0| 0| 1| 1| 1315| 45| 1275| 46| 1240| 48| 1200| 49| 1160| 51| 1120| 53| 1085|
55| 1045| 57
1| 0| 1| 1| 1350| 44| 1315| 45| 1280| 46| 1245| 48| 1205| 49| 1170| 51| 1135|
52| 1100| 54
0| 1| 1| 1| 1390| 43| 1350| 44| 1315| 45| 1275| 46| 1240| 48| 1200| 49| 1160|
51| 1125| 53
1| 1| 1| 1| 1420| 42| 1380| 43| 1345| 44| 1310| 45| 1270| 47| 1235| 48| 1200|
49| 1160| 51
Notes :
- Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
- Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
- Data is shown without filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises that are shaded in grey are not recommended.
BLOWER PERFORMANCE – KG7TA/TK Continued
G7TA/TK – 80% AFUE, Two Stage Gas Furnace
**Model Number| ****Heating Input (Btuh)| ****Motor
Switch Setting| External Static Pressure (in.w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
1/5| 2/6| 3/7| 4/8| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise| CFM| Rise| CFM| Rise
***TA100(C)-*B1|
**100000| 0| 0| 0| 0| 905| –| 890| –| 805|
–| 780| –| | | | | | | |
1| 0| 0| 0| 980| –| 930| –| 900| –| 835| –| 820| –| 800| –| 715| –| 670| –
0| 1| 0| 0| 1095| –| 1015| –| 980| –| 915| –| 895| –| 870| –| 810| –| 765| –
1| 1| 0| 0| 1160| 64| 1100| –| 1065| –| 1035| –| 995| –| 940| –| 895| –| 865|
–
0| 0| 1| 0| 1230| 60| 1195| 62| 1170| –| 1110| –| 1075| –| 1060| –| 995| –|
970| –
1| 0| 1| 0| 1315| 56| 1275| 58| 1240| 60| 1195| 62| 1160| 64| 1140| 65| 1115|
–| 1075| –
0| 1| 1| 0| 1345| 55| 1310| 57| 1280| 58| 1250| 59| 1220| 61| 1190| 62| 1140|
65| 1115| –
1| 1| 1| 0| 1445| 51| 1390| 53| 1350| 55| 1315| 56| 1280| 58| 1250| 59| 1230|
60| 1185| 63
0| 0| 0| 1| 1490| 50| 1430| 52| 1420| 52| 1380| 54| 1340| 55| 1310| 57| 1280|
58| 1275| 58
1| 0| 0| 1| 1550| 48| 1510| 49| 1475| 50| 1450| 51| 1420| 52| 1375| 54| 1340|
55| 1325| 56
0| 1| 0| 1| 1600| 46| 1270| 58| 1540| 48| 1500| 49| 1475| 50| 1445| 51| 1425|
52| 1385| 53
1| 1| 0| 1| 1640| 45| 1605| 46| 1570| 47| 1550| 48| 1525| 49| 1490| 50| 1460|
51| 1430| 52
0| 0| 1| 1| 1690| 44| 1665| 44| 1630| 45| 1600| 46| 1570| 47| 1550| 48| 1515|
49| 1490| 50
1| 0| 1| 1| 1755| 42| 1730| 43| 1680| 44| 1660| 45| 1640| 45| 1610| 46| 1575|
47| 1550| 48
0| 1| 1| 1| 1805| 41| 1770| 42| 1740| 43| 1715| 43| 1690| 44| 1655| 45| 1645|
45| 1605| 46
1| 1| 1| 1| 1860| 40| 1825| 41| 1790| 41| 1765| 42| 1745| 42| 1710| 43| 1695|
44| 1660| 45
***TA/TK-100(C)-*C1|
**100000**| 0| 0| 0| 0| 1125| 66| 1040| –|
960| –| | | | | | | | | |
1| 0| 0| 0| 1205| 61| 1120| –| 1040| –| 960| –| | | | | | | |
0| 1| 0| 0| 1305| 57| 1225| 60| 1150| 64| 1070| –| 995| –| 915| –| | | |
1| 1| 0| 0| 1430| 52| 1350| 55| 1270| 58| 1190| 62| 1110| –| 1030| –| 950| –|
865| –
0| 0| 1| 0| 1525| 49| 1450| 51| 1375| 54| 1300| 57| 1225| 60| 1150| 64| 1075|
–| 1000| –
1| 0| 1| 0| 1620| 46| 1540| 48| 1465| 51| 1390| 53| 1315| 56| 1240| 60| 1165|
64| 1090| –
0| 1| 1| 0| 1695| 44| 1620| 46| 1545| 48| 1465| 51| 1390| 53| 1315| 56| 1235|
60| 1160| 64
1| 1| 1| 0| 1770| 42| 1700| 44| 1630| 45| 1555| 48| 1485| 50| 1410| 53| 1340|
55| 1265| 59
0| 0| 0| 1| 1875| 40| 1805| 41| 1730| 43| 1655| 45| 1580| 47| 1510| 49| 1435|
52| 1340| 55
1| 0| 0| 1| 1905| 39| 1840| 40| 1775| 42| 1710| 43| 1640| 45| 1575| 47| 1510|
49| 1445| 51
0| 1| 0| 1| 1980| 37| 1910| 39| 1845| 40| 1780| 42| 1715| 43| 1650| 45| 1580|
47| 1515| 49
1| 1| 0| 1| 2025| 37| 1960| 38| 1895| 39| 1830| 40| 1765| 42| 1700| 44| 1635|
45| 1570| 47
0| 0| 1| 1| 2085| 36| 2025| 37| 1960| 38| 1900| 39| 1840| 40| 1775| 42| 1715|
43| 1655| 45
1| 0| 1| 1| 2135| 35| 2070| 36| 2010| 37| 1945| 38| 1880| 39| 1815| 41| 1750|
42| 1685| 44
0| 1| 1| 1| 2200| 34| 2145| 35| 2090| 35| 2035| 36| 1980| 37| 1925| 38| 1870|
40| 1820| 41
1| 1| 1| 1| 2280| 32| 2225| 27| 2170| 34| 2115| 35| 2065| 22| 2010| 37| 1955|
38| 1900| 39
Notes:
- Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
- Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
- Data is shown without filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises that are shaded in grey are not recommended.
BLOWER PERFORMANCE – KG7TA/TK Continued
****
Model Number
|
Heating Input (Btuh)
|
Motor Switch Setting
|
External Static Pressure (in.w.c.)
0.1
|
0.2
|
0.3
|
0.4
|
0.5
|
0.6
|
0.7
|
0.8
1/5
|
2/6
|
3/7
|
4/8
|
CFM
|
Rise
|
CFM
|
Rise
|
CFM
|
Rise
|
CFM
|
Rise
|
CFM
|
Rise
|
CFM
|
Rise
|
CFM
|
Rise
|
CFM
|
Rise
****
****
****
****
****
****
****
****
TA/TK-120(C)-C1
|
****
****
****
****
****
****
****
****
120000
|
0
|
0
|
0
|
0
|
1125
|
–
|
1040
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
0
|
0
|
0
|
1205
|
–
|
1120
|
–
|
1040
|
–
|
|
|
|
|
|
|
|
|
|
0
|
1
|
0
|
0
|
1305
|
–
|
1225
|
–
|
1150
|
–
|
1070
|
–
|
|
|
|
|
|
|
|
1
|
1
|
0
|
0
|
1430
|
62
|
1350
|
–
|
1270
|
–
|
1190
|
–
|
1110
|
–
|
1030
|
–
|
|
|
|
0
|
0
|
1
|
0
|
1525
|
58
|
1450
|
61
|
1375
|
65
|
1300
|
–
|
1225
|
–
|
1150
|
–
|
1075
|
–
|
1000
|
–
1
|
0
|
1
|
0
|
1620
|
55
|
1540
|
58
|
1465
|
61
|
1390
|
64
|
1315
|
–
|
1240
|
–
|
1165
|
–
|
1090
|
–
0
|
1
|
1
|
0
|
1695
|
52
|
1620
|
55
|
1545
|
58
|
1465
|
61
|
1390
|
64
|
1315
|
–
|
1235
|
–
|
1160
|
–
1
|
1
|
1
|
0
|
1770
|
50
|
1700
|
52
|
1630
|
55
|
1555
|
57
|
1485
|
60
|
1410
|
63
|
1340
|
66
|
1265
|
–
0
|
0
|
0
|
1
|
1875
|
47
|
1805
|
49
|
1730
|
51
|
1655
|
54
|
1580
|
56
|
1510
|
59
|
1435
|
62
|
1340
|
66
1
|
0
|
0
|
1
|
1905
|
47
|
1840
|
48
|
1775
|
50
|
1710
|
52
|
1640
|
54
|
1575
|
56
|
1510
|
59
|
1445
|
62
0
|
1
|
0
|
1
|
1980
|
45
|
1910
|
47
|
1845
|
48
|
1780
|
50
|
1715
|
52
|
1650
|
54
|
1580
|
56
|
1515
|
59
1
|
1
|
0
|
1
|
2025
|
44
|
1960
|
45
|
1895
|
47
|
1830
|
49
|
1765
|
50
|
1700
|
52
|
1635
|
54
|
1570
|
57
0
|
0
|
1
|
1
|
2085
|
43
|
2025
|
44
|
1960
|
45
|
1900
|
47
|
1840
|
48
|
1775
|
50
|
1715
|
52
|
1655
|
54
1
|
0
|
1
|
1
|
2135
|
42
|
2070
|
43
|
2010
|
44
|
1945
|
46
|
1880
|
47
|
1815
|
49
|
1750
|
51
|
1685
|
53
0
|
1
|
1
|
1
|
2200
|
40
|
2145
|
41
|
2090
|
43
|
2035
|
44
|
1980
|
45
|
1925
|
46
|
1870
|
48
|
1820
|
49
1
|
1
|
1
|
1
|
2280
|
39
|
2225
|
40
|
2170
|
41
|
2115
|
42
|
2065
|
43
|
2010
|
44
|
1955
|
45
|
1900
|
47
****
****
****
****
****
****
****
****
TA/TK-140(C)-D1
|
****
****
****
****
****
****
****
****
140000
|
0
|
0
|
0
|
0
|
1395
|
–
|
1350
|
–
|
1305
|
–
|
1260
|
–
|
1210
|
–
|
1165
|
–
|
|
|
|
1
|
0
|
0
|
0
|
1465
|
–
|
1420
|
–
|
1375
|
–
|
1330
|
–
|
1290
|
–
|
1245
|
–
|
1200
|
–
|
|
0
|
1
|
0
|
0
|
1555
|
67
|
1510
|
69
|
1470
|
–
|
1425
|
–
|
1380
|
–
|
1340
|
–
|
1295
|
–
|
1250
|
–
1
|
1
|
0
|
0
|
1625
|
64
|
1585
|
65
|
1540
|
67
|
1500
|
69
|
1460
|
–
|
1415
|
–
|
1375
|
–
|
1335
|
–
0
|
0
|
1
|
0
|
1690
|
61
|
1650
|
63
|
1610
|
64
|
1570
|
66
|
1530
|
68
|
1485
|
70
|
1445
|
–
|
1405
|
–
1
|
0
|
1
|
0
|
1760
|
59
|
1715
|
60
|
1670
|
62
|
1625
|
64
|
1575
|
66
|
1530
|
68
|
1485
|
70
|
1440
|
–
0
|
1
|
1
|
0
|
1835
|
57
|
1790
|
58
|
1745
|
59
|
1695
|
61
|
1650
|
63
|
1605
|
65
|
1555
|
67
|
1510
|
69
1
|
1
|
1
|
0
|
1885
|
55
|
1840
|
56
|
1790
|
58
|
1745
|
59
|
1700
|
61
|
1655
|
63
|
1610
|
64
|
1565
|
66
0
|
0
|
0
|
1
|
1945
|
53
|
1900
|
55
|
1850
|
56
|
1805
|
57
|
1760
|
59
|
1710
|
61
|
1665
|
62
|
1620
|
64
1
|
0
|
0
|
1
|
1950
|
53
|
1905
|
54
|
1860
|
56
|
1820
|
57
|
1775
|
58
|
1735
|
60
|
1690
|
61
|
1650
|
63
0
|
1
|
0
|
1
|
2075
|
50
|
2030
|
51
|
1990
|
52
|
1945
|
53
|
1900
|
55
|
1855
|
56
|
1810
|
57
|
1770
|
59
1
|
1
|
0
|
1
|
2125
|
49
|
2085
|
50
|
2040
|
51
|
2000
|
52
|
1955
|
53
|
1910
|
54
|
1870
|
55
|
1825
|
57
0
|
0
|
1
|
1
|
2170
|
48
|
2130
|
49
|
2090
|
50
|
2045
|
51
|
2005
|
52
|
1965
|
53
|
1925
|
54
|
1880
|
55
1
|
0
|
1
|
1
|
2215
|
47
|
2180
|
48
|
2140
|
48
|
2105
|
49
|
2070
|
50
|
2035
|
51
|
2000
|
52
|
1965
|
53
0
|
1
|
1
|
1
|
|
|
|
|
|
|
|
|
2225
|
47
|
2165
|
48
|
2100
|
49
|
2040
|
51
1
|
1
|
1
|
1
|
|
|
|
|
|
|
|
|
|
|
2170
|
48
|
2120
|
49
|
2065
|
50
Notes:
- Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
- Two openings are required for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
- Data is shown without filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises that are shaded in grey are not recommended.
MODEL IDENTIFICATION CODE
SPECIFICATIONS
KG7TA/TK MODEL NUMBERS| **060C-23A1| ****080C-24B1|
****100C-24B1| ****100C-35C1| ****120C-35C1| ****140C-45D1
---|---|---|---|---|---|---
Input – Btuh (a)| 60,000 / 39,000| 80,000 / 52,000| 100,000 / 65,000| 100,000
/ 65,000| 120,000 / 78,000| 140,000 / 91,000
Heating Capacity – Btuh| 48,000 / 31,200| 64,000 / 41,600| 80,000 / 52,600|
80,000 / 52,600| 96,000 / 62,400| 112,000 / 72,800
AFUE**| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0
Blower D x W| 10 x 6| 11 x 8| 11 x 8| 11 x 10| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/2 BLDC| 1/2 BLDC| 1/2 BLDC| 3/4 BLDC| 3/4 BLDC| 1
BLDC
Motor FLA| 6.2| 6.2| 8.7| 8.7| 8.7| 11.7
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 25-55| 30-60| 30-60| 35-65| 35-65| 40-70
Shipping Weights – TA| 104lbs| 116lbs| 120lbs| 135lbs| 135lbs| 154lbs
Shipping Weights – TK| 104lbs| 116lbs| 116lbs| 135lbs| 140lbs| 146lbs
All models are 115 V, 60 HZ. Gas connections are 1/2″ N.P.T. AFUE= Annual Fuel Utilization Efficiency
ACCESSORIES
KG7TA/TK KITS
Description| SKU
Fixed Speed to Variable Speed| 904880
“A” Cabinet Downflow Sub Base Kit| 902974
“B”, “C”, “D” Cabinet Downflow Sub Base Kit| 904911
U.S. LP Conversion Kit (0 to 10,000 ft.)| 905028
Canada LP Conversion Kit (0 to 4,500 ft.)| 905029
Bottom Return Filter 20 per Box, “B” Cabinet| 904916
Bottom Return Filter 20 per Box, “D” Cabinet| 904918
Side Return Filter Kit| 541036
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations
subject to change without notice and without incurring obligations. Printed in U.S.A (06/2017