Pro Series 29DPSSF18TPSI-N Round Flat Disc Fire Pits Instruction Manual
- June 15, 2024
- PRO-SERIES
Table of Contents
- 29DPSSF18TPSI-N Round Flat Disc Fire Pits
- 61 (0.039)
- 72 (0.025)
- 61 (0.039)
- 72 (0.025)
- 61 (0.039)
- 72 (0.025)
- PREPARING A NON-COMBUSTIBLE STRUCTURE
- HARD PIPING TO FIRE PIT WITHOUT GAS PROXIMITY
- ****PREPARING A NON-COMBUSTIBLE STRUCTURE
- INSTALLATION OF FIRE PIT INTO AN APPROVED ENCLOSURE
- REQUIREMENTS
- REMOVING PARTS FROM CARTON
- PREPARING BURNERPAN FOR INSTALLATION
- FINAL PREPARATION
- IF USING AMD DIRECT, INC GL GLASS OR GLR
- OPERATION
- SAFETY WARNINGS
- WARNING
- TURNING ON FIRE PIT
- TURNING OFF FIRE PIT
- TPSI REPLACEMENT PARTS
- REPLACEMENT PARTS LIST
- FIRE PIT MAINTENANCE
- Brass Burner Maintenance Information:
- TROUBLE SHOOTING
- Water in my fire pit
- OPTIONAL ACCESSORIES
- READY TO FINISH/ANF ENCLOSURES
- ACCESSORIES
- BURNER SYSTEMS, BURNERS, COMPONENTS AND ACCESSORIES
- OUTDOOR FIREPLACE – KALEA BAY
- SANCTUARY SERIES – GFRC FIRE FEATURES
- READY TO FINISH (RTF) ENCLOSURES
- ACCESSORIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
29DPSSF18TPSI-N Round Flat Disc Fire Pits
DO NOT DISCARD. THIS MANUAL HAS IMPORTANT OPERATING AND
MAINTENANCE INSTRUCTIONS. LEAVE WITH THE HOMEOWNER.
Models
N= Natural Gas
|
Models
P= Propane
|
Description
---|---|---
FPB-19DPSSF11TPSI-N
|
FPB-19DPSSF11TPSI-P
|
19” Round Flat Disc & 11” Pro Snowflake Burner
FPB-25DPSSF18TPSI-N
|
FPB-25DPSSF18TPSI-P
|
25” Round Flat Disc & 18” Pro Snowflake Burner
FPB-29DPSSF18TPSI-N
|
FPB-29DPSSF18TPSI-P
|
29” Round Flat Disc & 18” Pro Snowflake Burner
Round Flat Disc Fire Pits with Thermocouple Piloted Safety Ignition
(TPSI) & Pro Brass Snowflake Burner Installation and Operating Instructions
IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS
DO NOT ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE
These fire pits are manufactured from the factory as Natural or Propane Gas.
These are not convertible from one gas to another. Ensure you order the proper
gas type before installing.
INSTALLATION PRECAUTION:
This fire pit requires a minimum 18-square inches (per side) of cross
ventilation.
Failure to provide proper ventilation can void the warranty.
Warning: For Outdoor Use Only
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed area can kill you.
Never use this appliance in an enclosed space such as a camper, tent, car or home.
DANGER
If you smell gas:
1. Shut off gas to the appliance
2. Extinguish any open flame.
3. If odor continues, keep away from
the appliance and immediately call
your gas supplier or fire department.
WARNING
Do not store or us gasoline or other
flammable vapors and liquids in the
vicinity of this or other appliances.
Any LP cylinder not connected for use
shall not be stored in the vicinity of this
or other appliances.
WARNING
Do not leave unattended during use.
Do not use for cooking.
Follow all gas leak procedures in this
manual prior to operation.
WARNING
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property damage.
Read the installation, operating and
maintenance instructions thoroughly
before installing or servicing this
equipment.
WARNING
If the information in these instructions is not followed exactly, a fire or
explosion
may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity
of this or other appliances.
Fuels used in gas fired appliances, and the products of combustion such as
fuels, contain
chemicals known to cause cancer, birth defects and/or other reproductive harm.
This warning is issued pursuant to the California Health & Safety Code Sec.
25249.1
CALIFORNIA PROPOSITION 65
WARNING
This product is designed to operate with one of the following fuel sources:
Liquid Propane or Natural Gas. The fuel
used to operate this product, and the products of combustion of such fuel, can
expose you to chemicals including
Benzene which is known to the State of California to cause cancer, birth
defects and other reproductive harm and
Carbon Monoxide which is known to the State of California to cause birth
defects or other reproductive harm.
(For more information go to: www.p65Warnings.ca.gov.)
NOTE: An exterior lid/cover is not required but highly recommended when
the fire pit is not in use. Even though fire
pits are designed for outdoors they are not impervious to all weather
conditions if not protected. See the accessory
page for information and sizes.
Congratulations! You have just purchased a AMD Direct, Inc “Pro Series”
Snowflake Burner. These are Brass
Burners that come with a 11” and 18” burner. The 11” burner has 8 injectors
and the 18” burner has 24
injectors. Each model burner has individual injectors that eliminates the need
for a main burner orifice.
All media (i.e. lava rock, lava stones, lava boulders and fire glass) has the
potential of thermal
spalling. This is a process that may occur when media is wet and moisture gets
trapped inside of
the material due to rapid temperature differences. When this happens the media
has the potential
to crack or “pop” outside the fireplace.
WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE
The use of a cover can lessen the impact of thermal spalling; however, heavy
rains, high
humidity and the presence of moisture may still cause the media to pop.
ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE
Extra caution should be taken when lighting a fireplace when heavy rains, high
humidity and
moisture are present. Light the fireplace; leave the area allowing any
moisture in the media to
dissipate. We strongly recommend that during this drying out time that you
monitor the fire feature
from a distance. This drying out period should be no less than 30 minutes.
Continue monitoring
the flame from distance to ensure that all popping has ceased before fully
enjoying the fire.
SPECIFICATIONS
MODELS
N = Natural
P = Propane
|
PAN
DIMENSIONS
(I.D.)
|
MAX.
OPENING SIZE
|
BURNER
SIZE
|
GROUND LEVEL
|
SIDE
WALL
|
COMBUSTIBLE CEILING
|
COMBUSTIBLE FLOOR
---|---|---|---|---|---|---|---
FPB-19DPSSF11TPSI-N FPB-19DPSSF11TPSI-P
|
19” Diameter (I.D.) (483mm)
|
20” Diameter (508mm)
|
11” Sq.
(279mm)
|
8”
(203mm)
|
36”
(914mm)
|
96”
(3048mm)
|
18”
(457mm)
FPB-25DPSSF18TPSI-N FPB-25DPSSF18TPSI-N
|
25” Diameter (I.D.) (635mm)
|
26” Diameter (660mm)
|
18” Sq.
(457mm)
|
8”
(203mm)
|
36”
(914mm)
|
120”
(3048mm)
|
18”
(457mm)
FPB-29DPSSF18TPSI-N FPB-29DPSSF18TPSI-N
|
29” Diameter (I.D.) (737mm)
|
27” Diameter (686mm)
|
18” Sq.
(457mm)
|
8”
(203mm)
|
36”
(914mm)
|
120”
(3048mm)
|
18”
(457mm)
Models:
Natural Gas
|
Jets
|
NG Injector Size
|
BTU
Ratings
|
Models:
Propane Gas
|
LP Injector Size
|
BTU
Ratings
---|---|---|---|---|---|---
FPB-19DPSSF11TPSI-N
|
8
|
61 (0.039)
|
50K (14.65kW)
|
FPB-19DPSSF11TPSI-N
|
72 (0.025)
|
42K (12.30kW)
FPB-25DPSSF18TPSI-N
|
24
|
61 (0.039)
|
145K (42.95kW)
|
FPB-25DPSSF18TPSI-N
|
72 (0.025)
|
124K (36.34kW)
FPB-29DPSSF18TPSI-N
|
24
|
61 (0.039)
|
145K (42.95kW)
|
FPB-29DPSSF18TPSI-N
|
72 (0.025)
|
124K (36.34kW)
Table 3 Burner specifications
Disclaimer: BTU listings are based on 7.0”WC for Natural Gas
and 11.0”WC for Liquid Propane (LP) at the burner orifice. Flex
line size and proper gas pipe sizing will also affect BTU’s. As a
result your BTU’s may vary slightly from Table 2 specifications.
CAUTION:
No LPK conversion kits are available for brass burners.
You must order the correct burner.
PREPARING A NON-COMBUSTIBLE STRUCTURE
Description: These fire pits are designed to be installed into a non-
combustible enclosure. They are a “drop-in pan”
style system to make installation quick and convenient. Media (not supplied)
is required inside the burner pan for
operation (See page 9).
WARNING: Proper clearances from combustible materials must be maintained
from all sides, top and bottom of this
appliance. Use the specifications listed on pages 4 for proper clearance to
combustibles.
AMD Direct, Inc fire pits are constructed and tested to follow the rigid ANSI
standards for gas appliances and
manufactured safely providing dependable and certified products. If these fire
pits are not installed according to the
installation manual (i.e. not providing ventilation, not providing proper
drainage, installing fire pits below grade or
modifying the existing products from a normal installation) AMD Direct, Inc
cannot be responsible if the product does not
operate as designed.
Modifying the fire pit directly out of the carton will void the warranty and
nullify the product listing it was certified for.
Before you consider creating your own custom design with a certified product
ensure you contact AMD Direct, Inc to
consult the installation before proceeding. If you move forward and modify a
product without consulting, Firegear
Outdoors cannot be responsible if the product does not operate as designed.
HARD PIPING TO FIRE PIT WITHOUT GAS PROXIMITY
NOTE: Refer to the NFPA54 (National Fuel Gas Code) for proper pipe
sizing. See gas line sizing chart on page 7 as a
reference.
-
Turn OFF gas supply system. NOTE: All gas connections (except for brass to brass) require the following. Clean pipe
threads using either a wire brush or steel wool. Apply pipe sealant to the fittings before making any connection.
BE CAREFUL! Ensure all gas connections are snug, but do not over tighten! -
Extend the gas supply system using minimum of ¾” black iron pipe or an approved flexible gas line from existing
house supply. This can be accomplished by teeing off or tapping into a gas line connection. Install necessary pipe for the
distance required and then install a manual shut-off valve at the exterior house wall. If pipe is to pass through a foundation
or house wall, make sure to re-seal the area around the pipe with weather sealant. -
The primary gas shut-off (not supplied) will require a ½” male flared fitting to enable connection of the stainless steel
flex gas line supplied with the fire pit (see Fig. 7 page 9).
IMPORTANT
Installation of Natural or LP gas should be done by a qualified installer,
service agency or gas supplier.
This appliance must be isolated from the gas supply piping system by closing
its manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures equal to or
less than ½” psig (3.5kPa)
Injectors/Jets – Fire features using a Firegear Pro Series brass burner
incorporates individual injectors/jets on each
burner leg. All injectors are protected by a injector cover that is provided
with each burner. The injector hole size is
measured by using a numbered drill bit. An injector/jet limits the amount of
gas flow to the burner to ensure the flame is a
safe and reasonable height to not pose a risk to people or property. Note: The
Firegear Pro Series brass burners DO NOT
USE a primary main burner orifice like a standard stainless steel burner. A
steel nipple is installed in place of the primary
burner orifice. Each injector is installed at an angle inside each burner leg
to maximize flame appearance.
ALL PAN OR FLAT DISCS MUST BE REMOVABLE FOR SERVICE Pans or Discs CANNOT
be installed
in a manner to prevent them from being removed for service. Top coping
material or top cap of fire pit
MUST NOT overlap onto the pan or disc surface without easily being removed.
Pan lip of disc edge must
be unobstructed so it can be lifted our of the fire pit for servicing. We
highly recommend the use of a flex
frame kit for all installations.
****PREPARING A NON-COMBUSTIBLE STRUCTURE
VENTILATION FOR NON-COMBUSTIBLE ENCLOSURE
Fire pits are subjected to many outdoor elements such as rain,
snow, wind, heat or cold. A minimum of 18 square inches
(two opposite sides) of cross ventilation is required to
keep the components in good working order. Use Fig. 3 as
guide to assist to incorporate proper ventilation.
INSTALLATION OF FIRE PIT INTO AN APPROVED ENCLOSURE
REQUIREMENTS
-
Only non-combustible materials should come in direct contact with any part of the fire pit. Underneath area should
be non-combustible or a flat level combustible surface according to the clearances specified in this manual. -
Refer to the NFPA54 (National Fuel Gas Code) for proper pipe sizing. Determine the size of the fire pit you are
preparing to install (Refer to page 7). -
You must provide a rectangular opening cutout to place the fire pit into the non-combustible enclosure. Refer to Table
1, dimension A. -
DO NOT place an LP tank inside any fire pit enclosure. Locate all Propane (LP) tanks outside the enclosure.
-
Follow the local code requirements for the gas type being used. This fire pit should be installed in accordance with
local codes and ordinances or in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1
NFPA54 or CSA B149.1, Natural and Propane Installation Code in Canada. -
Fire pits create high temperatures, it is very important to have any combustibles at a safe distance.
-
CAUTION: A minimum of 18 square inches of cross ventilation (opposite sides) is required to keep the
enclosure dry. See Fig. 3. -
These products are designed for outdoor use only. Not approved for any indoor use.
-
This fire pit is designed to have AMD Direct, Inc lava rock or glass media completely covering the burner, so that the
burner is not visible. Do not cover more than 1” above the top of burner. Ensure the injectors are not blocked by any
media. Use lava rock a minimum of 1” diameter as a base to fill the burner pan. DO NOT USE STONE OR RIVER
ROCK. -
Gas lines and fittings must be installed into the non-combustible structure. All gas connections must be leak tested
before installation of the fire pit. Soapy water leak detection is required before regular use of the fire pit. -
Do not use media that will absorb moisture over time and will not release this moisture quickly. Moisture can boil in
this material and can rapidly break apart and cause damage or personal injury. See Caution on bottom of page 3. -
Never leave any combustible material on top of the fire pit. This could cause unsafe operation of this system and
damage to the component that will not be covered under our warranty. -
Ensure proper water drainage is also incorporated into the fire pit enclosure.
GAS PIPE SIZING CHART
NATURAL GAS : PIPE SIZING CHART
Length of Pipe in Feet 1/2” 3/4” 1” 1 – 1/4” 1 – 1/2” 2” 2 – 2 1/2” 3” 4”
10 108 230 387 793 1237 2259 3640 6434 – 20 75 160 280 569 877 1610 2613 5236 9521 30 61 129 224 471 719 1335 2165 4107 7859 40 52 110 196 401 635 1143 1867 3258 6795 50 46 98 177 364 560 1041 1680 2936 6142 60 42 89 159 336 513 957 1559 2684 5647 70 38 82 149 317 476 896 1447 2492 5250 80 36 76 140 239 443 840 1353 2315 4900 90 33 71 133 275 420 793 1288 2203 4667 100 32 68 126 266 411 775 1246 2128 4518 125 28 60 117 243 369 700 1143 1904 4065 150 25 54 105 215 327 625 1008 1689 3645 175 23 50 93 196 303 583 993 1554 3370
200 22 47 84 182 280 541 877 1437 3160 300 17 37 70 145 224 439 686 1139 2539
LIQUID PROPANE : PIPE SIZING CHART
Length of Pipe in Feet 1/2” 3/4” 1” 1 – 1/4” 1 – 1/2” 2” 2 – 2 1/2” 3” 4”
10 275 567 1071 2205 3307 6221 10140 17990 35710 20 189 393 732 1496 2299 4331 7046 12510 25520 30 152 315 590 1212 1858 3465 5695 10110 20620 40 129 267 504 1039 1559 2992 4778 8481 17300 50 114 237 448 913 1417 2646 4343 7708 15730 60 103 217 409 834 1275 2394 3908 6936 14150 70 89 185 346 724 1086 2047 3329 5908 12050 80 78 162 307 630 976 1811 2991 5309 10830 90 69 146 275 567 866 1606 2654 4711 9613 100 63 132 252 511 787 1496 2412 4281 8736
125 54 112 209 439 665 1282 2083 3618 7382 150 48 100 185 390 590 1138 1808 3210 6549 175 43 90 168 353 534 1030 1637 2905 5927 200 40 83 155 325 491 947 1505 2671 5450 300 37 77 144 303 458 887 1404 2492 5084
• Natural Gas (NG) flow is given in thousands of BTU/hr. = 1 cubic foot of NG gas – 1000 BTU
• Nominal pressure at the burner for Natural Gas is 3.5” of water column. (Typical machine supply 5”-7”)
• Pipe length must include additional length for all fittings. Add approximately 5 feet of pipe per fitting.
• Natural Gas Example: A machine with a burner that requires 440,000 BTU would need a 1 -1/4” pipe for a 20” long run.
• Liquid Propane (LP) Gas flow is given in thousands of BTU/hr. = 1 cubic foot of LP gas – 2500 BTU.
• This chart refers to low pressure LP, after regulation, Standard nominal pressure at the burner for Liquid Propane Gas is 11” of water column.
• Pipe length must include additional length for all fittings. Add approximately 5 feet of pipe per fitting.
• LP Example: A machine with a burner that requires 440,000 BTU would need a 1” pipe for a 20’ long run.
NOTE: The sizing charts above list the specific pipe sizes required for the amount of BTU’s for a new gas line installations. If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure. This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel Gas Code – current edition) for more details.
Table 4 Gas pipe sizing.
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 7
Valve Assembly
REMOVING PARTS FROM CARTON
Fig. 4 Removing contents from carton.
The fire pit comes partially assembled from the factory. The pilot tubing and thermocouple leads are 48” in total length, therefore, when mounting the Gas Valve/Piezo mounting plate, ensure the mounting plate is close enough to make all connections.
Open carton and remove contents. Inspect for any damage or missing parts.
The hardware bag includes mounting plate screws, orifice, Piezo wires and flex connector to complete the installation.
Carefully install the fire pit into the prepared enclosure, connect the gas line and wire according to the figure drawings in this manual.
INSTALLING NIPPLE INTO BURNER
Before the fire pit is installed:
Install a 2” nipple and flared fitting into the bottom of the burner. Ensure the nipple has gas rated Teflon tape wrapped around the threads. Thread the nipple into the burner in a clockwise manner. Secure into position. See Fig. 5.
CONTROL PANEL MOUNTING PLATE
The control panel mounting plate is pre-assembled at the factory with the gas valve and Piezo ignitor. On the back of this manual is a template for use to cut an opening for the mounting plate. Once you have determined the location of control panel mounting plate install the gas connections and Piezo wires as shown in Fig. 6 and secure all
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 8
PREPARING BURNERPAN FOR INSTALLATION
Gas valve and flexible gas lines are supplied; E-Stop shut-off is not supplied, but available in accessories page. Flex lines with flared fittings do not require Teflon tape or pipe compound.
Ensure not to “kink” the flex lines to allow better gas flow of gas. The illustration above is only a guide for the gas connection. Local codes may require different methods to connect the gas supply.
FINAL PREPARATION
INJECTOR HOOD/RAIN SHIELD INSTALLATION Install the hood/rain shields over top of each injector of the pro brass burner by sliding it into position. Use the bead in the lower section of the hood, and align it with the groove in the injector, until it snaps into place. See Fig. 8. Rotate the hood to ensure it is protecting the injector opening from the elements (i.e. rain, dirt or media). See Fig. 9 for proper alignment. Note: If there is no detent in the injector, ensure the hood is ½” from the base of the injector to the bottom edge of the hood.
INSTALLATION OF MEDIA INTO BURNER PAN Install lava rock into the burner pan. Ensure the lava rock is a minimum of 1-inch diameter for proper operation. Note: Do not pour Lava Rock directly from bag. It should be placed naturally and NOT packed in tight. Loose fitting is important to ensure robust flames. Placing the lava rock in the pan by hand, ensures no excessive dust from bag lays in the bottom of pan and potentially plugs the burner port holes or the pan weep holes. DO NOT BLOCK INJECTORS WITH MEDIA.
CAUTION: It is imperative the “open side” of all hoods
covering the injectors/jets are installed facing downward.
Because the hoods can be removed or turned, the
orientation is extremely important to protect the injector or
jets from dust, dirt or rain. See detail in Fig. 8.
WARNING: Failure to orient the hoods in the
proper position on the burner tube will void
the manufacturer warranty.
IF USING AMD DIRECT, INC GL GLASS OR GLR
REFLECTIVE GLASS, ENSURE THE MEDIA DOES NOT
BLOCK THE INJECTOR HOLES.
IMPORTANT: DO NOT PLACE ROCK OVER TOP OR
UNDER THE PILOT SCREEN COVER. The screen must
be free of any debris to ensure proper lighting of burner
and good flame sense (See Fig. 11).
Cover the burner completely with media but do not make
the depth greater than 1-inch over-top of the burner
port holes.
Do NOT cover the top of mesh pilot hood with any rock or
glass. It must be free an any debris to operate properly.
OPERATION
CAUTION : Children and adults should be alerted to the hazards on high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the area of the appliance.
WARNING: Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of control system and any gas control, which has been under water.
SAFETY WARNINGS
1. Never leave the fire pit unattended during operation.
2. Clothing or other flammable materials should not be placed on or near the appliance.
3. Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance.
4. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative the control compartment, burners and circulating air passageways of the appliance be kept clean.
5. Inspect the fuel supply connection before each use of the appliance.
6. Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply (Natural or L.P. gas line).
WARNING
1. This appliance is hot when operated and can cause sever burns if contacted.
2. Do not burn any solid fuels in this appliance.
READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LIGHT FIRE PIT CAUTION: ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING.
WARNING: Do not stand over fire pit during ignition or operation due to high surface temperatures. LIGHTING INSTRUCTIONS
TURNING ON FIRE PIT
1. Depress and hold the red Piezo button and ensure sparking is occurring inside the pilot hood. An audible sparking sound can be heard.
2. While holding the Piezo button, slightly depress the control knob inward and rotate counter clockwise to the PILOT position. Depress and hold control knob inward for at least 30 to 60 seconds; to light the PILOT. 3. Once the pilot lights, release the Piezo button and turn control knob counter clockwise to the ON position. If pilot does not stay lit, release the control knob, turn the control knob clockwise to turn OFF and wait 5 minutes before trying again. Turn gas supply OFF to check ignitor spacing and Piezo battery if no sparking occurs. 4. Repeat steps 1-4 to try again.
TURNING OFF FIRE PIT
1. Slightly depress the control knob inward and rotate the knob clock wise to OFF position. Fire pit will turn OFF. 2. After cooling off install cover (if applicable).
TPSI REPLACEMENT PARTS
REPLACEMENT PARTS LIST
Item Description
Qty. Part #
1
|
19” Round Stainless Flat Pan
|
1
|
PAN-SS19D
---|---|---|---
1A
|
25” Round Stainless Flat Pan
|
1
|
PAN-SS25D
1B
|
29” Round Stainless Flat Pan
|
1
|
PAN-SS29D
2
|
Brass Burner Support & Hardware Bag
|
1
|
10850
3
|
18” Pro Brass Snowflake Burner – Natural Gas
|
1
|
10902
3A
|
18” Pro Brass Snowflake Burner – Propane Gas
|
1
|
10903
4
|
11” Pro Brass Snowflake Burner – Natural Gas
|
1
|
10900
4A
|
11” Pro Brass Snowflake Burner – Propane Gas
|
1
|
10901
5
|
½” Flex Gas Line (46-inch Length)
|
1
|
T-200-9898-46
6
|
Copreci High Capacity Gas Valve
|
1
|
68001599
7
|
Lock Nut, M15 x 1 for TPSI Gas Valve
|
1
|
08032504
8
|
Gas Valve Control Knob for TPSI Valve
|
1
|
CN-ALHC
9
|
Complete Natural Gas Pilot Assembly with 48” leads
|
1
|
PSE-NA495
10
|
Complete Propane Gas Pilot Assembly with 48” leads
|
1
|
PSE-LP495
11
|
TPSI Face Plate
|
1
|
78188
12
|
½” OD Flare to 3/8” MIP Fitting
|
1
|
U1-8C-S
13
|
½” NPT Female to ½” Male Flare Fitting
|
1
|
U3-8D-S
14
|
½” Flare to ½” MIP 90° elbow
|
1
|
49-88
15
|
LP Regulator with 32” Hose – NOT FOR USE WITH NATURAL GAS
|
1
|
FG-32LPHRK
16
|
1/2” MIP x 2” Stainless Steel Nipple (not shown)
|
1
|
10858
17
|
½” Flare to 1/2” FIP Fitting (used with all kits) (not shown)
|
1
|
46-86
18
|
Manual Spark Ignitor Module (not shown)
|
1
|
3042-RB
19
|
Spark Ignitor for 3042-RB (not shown)
|
1
|
3042-RB -IGNITOR
20
|
Plastic Nut for 3042-RB (not shown)
|
1
|
3042-RB-NUT
21
|
25” Piezo Extension wire – See page 16 (not shown)
|
1
|
PIEZO25WH
22
|
48” Piezo Extension wire – See page 16 (not shown)
|
1
|
PIEZO48WH
23
|
Ground tab for Piezo ignition (not shown)
|
1
|
GROUNDTAB
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 13
FIRE PIT MAINTENANCE
1. The fire pit should be inspected and cleaned before initial use, at least annually, by a qualified field service person.
2. Any component that is found faulty must be replaced with an approved component.
3. Any tampering or modifying with the fire pit is dangerous and voids all warranties.
4. During winter months in cold climates and various seasons of operation the fire pit may be affected by weather conditions. It is recommended to use a ventilated cover over top of your fire pit to protect it from humid/rainy weather conditions when not in use. Heavy rains/downpours could affect the fire pit operation if not covered; if this occurs ensure you allow the fire pit time to dry out before attempting to operate.
NOTE: If a combustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard.
5. Over time stainless steel parts can discolor when heated, usually a golden or brown hue. This discoloration is normal and does not affect the performance of the appliance.
Brass Burner Maintenance Information:
• Dust in injector – Use compressed air from aerosol can or compressor.
• Check for bug nests or stubborn debris – replacement where necessary.
Note: Always use safety equipment including but not limited to SAFETY glasses or goggles when using compressed air and consider a disposable mask for particulate.
TROUBLE SHOOTING
Symptom Remedy
Fire pit won’t light
1. Bleed gas line.
2. Ensure all gas supply lines are turned ON.
3. Ensure there is not too much media over top of burner; it can inhibit gas from flowing.
4. Check gas pressure.
Low flame 1. Ensure the base media is at least 1-inch in diameter and top media is no more than 1-inch over top of burner and do not cover injectors.
2. Ensure all shut-off valves and key valve is fully open. See page 9; Fig. 7
3. Check gas pressure.
Water in my fire pit
1. Excess dust/sand material from media may be blocking the weep holes to relieve water.
2. Remove all media and unplug weep holes. Clean or install new media free of dust and dirt.
3. Ensure fire pit enclosure has proper drainage for water and proper ventilation to dry out.
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 14
OPTIONAL ACCESSORIES
The following accessories are available from your local AMD Direct, Inc dealer/distributor.
Each accessory comes with a separate installation manual. Read each instruction thoroughly before installing.
Lids for Drop-In Pan
Models:
LID-19R2 (19” Rd.drop-in pan)
LID-25R2 (25” Rd.drop-in pan)
LID-20S (20” Sq. drop-in pan)
LID-26S (26” Sq. drop-in pan)
|
Media
Lava Stones 1” to 2” size (50lbs.) Models: FG-LS50 (Bag)
Lava Rock 1” to 2” size
Models: FG-LAVA-40 (Bag)
FG-LAVA-10 (Bag)
See catalog for various colors.
|
Glass Windshields
See catalog for a windshield to fit your application.
FLEXFRAME
Universal brackets to support fire pit when using paver blocks or other non combustible enclosures.
Model: FLEXFRAME-SS (2 piece) Model: FLEXFRAME-SS3 (3 piece)
---|---|---
CAUTION:
LPK conversion kits are not available for any brass burner.
MSI (Manual Spark Ignition) kits are not available for brass burners.
|
E-STOP
Mechanical gas timer valve with emergency shut-off.
Model: ESTOP1-0H 1hr. timer Model: ESTOP2-5H 2.5hr. timer
|
Shut-Off Valves
Model: 01-387 ⅜” OD Flare x ½” FIP Model: 01-487 ½” OD Flare x ½” FIP Model: 01-266
⅜” OD Flare x ⅜” OD Flare Model: 01-288
½” OD Flare x ½” OD Flare
NOTE: See the AMD Direct, Inc catalog for other accessories also available.
FOR TECHNICAL SERVICE, CALL: 800-966-8126
AMD Direct, Inc Outdoors
17322 Gothard St.
Huntington Beach, CA 92647
Web Site: www.amddirect.com
Manual changes often occur, ensure to check the AMD Direct
website for any recent updates and warranty information.
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 15
AMD DIRECT LIMITED WARRANTY – 2022 / 2023
AMD DIRECT hereby warrants to the end user that products will be free from material and workmanship de fects that prevent safe and correct operation of the product. The warranty commences from date of sale to the end user for the following period:
CONSUMER RESIDENTIAL APPLICATIONS – MANUFACTURED AFTER 12/02/2019
• BURNER SYSTEMS, BURNERS, COMPONENTS AND ACCESSORIES
• LIFETIME WARRANTY ON CONSTRUCTION AND MANUFACTURER DEFECTS
• LIFETIME WARRANTY – STAINLESS STEEL BURNERS AND PANS
• LIFETIME WARRANTY – BRASS BURNERS
• FIVE (5) YEAR WARRANTY – GAS VALVE, SPARK IGNITER, PILOT ASSEMBLIES
• FIVE (5) YEAR WARRANTY – AWS ELECTRONIC IGNITION SYSTEMS (24VAC, 30 VDC)
• FIVE (5) YEAR WARRANTY – TMSI/TPSI ELECTRONIC COMPONENTS
• FIVE (5) YEAR WARRANTY – MT COMPONENTS (KEY VALVE)
• FIVE (5) YEAR WARRANTY – REFRACTORY GAS LOG SETS
• FIVE (5) YEAR WARRANTY – READY TO FINISH/ANF FIRE PIT ENCLOSURES
• FIVE (5) YEAR WARRANTY – SKYTECH MANUFACTURED OPTIONAL CONTROLS
• OUTDOOR FIREPLACE – KALEA BAY
• LIFETIME WARRANTY – CONSTRUCTION AND MANUFACTURER DEFECTS
• LIFETIME WARRANTY – STAINLESS STEEL COMPONENTS
• FIVE (5) YEAR WARRANTY – GAS VALVE, PILOT ASSEMBLY, POWER SUPPLY, CONTROLS
• FIVE (5) YEAR WARRANTY – SKYTECH MANUFACTURED OPTIONAL CONTROLS
• SANCTUARY SERIES – GFRC FIRE FEATURES
• THREE (3) YEAR WARRANTY – GFRC STRUCTURE
• REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANT
WARRANTY COVERS MANUFACTURING DEFECTS OR STRUCTURAL FAILURE. SMALL STRESS CRACKS AND SURFACE CRAZING ARE A NATURAL OCCURRENCE IN GFRC PRODUCTS AND NOT COVERED BY WARRANTY.
READY TO FINISH/ANF ENCLOSURES
• FRAME – LIFETIME WARRANTY ON CONSTRUCTION AND MANUFACTURER DEFECTS
ACCESSORIES
• LIFETIME WARRANTY – CONSTRUCTION AND MANUFACTURER DEFECTS
• LIFETIME WARRANTY – STAINLESS STEEL COMPONENTS (LIDS, STAINLESS STEEL COVERS)
• ONE (1) YEAR WARRANTY – ESTOP1-OH, ESTOP2-5H WINDSHIELDS, HOSES AND REGULATORS
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 16
COMMERCIAL APPLICATIONS – MANUFACTURED AFTER 12/02/2019
BURNER SYSTEMS, BURNERS, COMPONENTS AND ACCESSORIES
• TWO (2) YEAR WARRANTY ON CONSTRUCTION AND MANUFACTURER DEFECTS
• TWO (2) YEAR WARRANTY – STAINLESS STEEL BURNERS AND PANS
• TWO (2) YEAR WARRANTY – BRASS BURNERS
• TWO (2) YEAR WARRANTY – GAS VALVE, SPARK IGNITER, PILOT ASSEMBLIES
• TWO (2) YEAR WARRANTY – AWS ELECTRONIC IGNITION SYSTEMS (24VAC, 30 VDC)
• TWO (2) YEAR WARRANTY – MT COMPONENTS (KEY VALVE)
• TWO (2) YEAR WARRANTY – REFRACTORY GAS LOG SETS
• FIVE (5) YEAR WARRANTY – READY TO FINISH/ANF FIRE PIT ENCLOSURES
• TWO (2) YEAR WARRANTY – SKYTECH MANUFACTURED OPTIONAL CONTROLS
OUTDOOR FIREPLACE – KALEA BAY
• LIFETIME WARRANTY – CONSTRUCTION AND MANUFACTURER DEFECTS
• LIFETIME WARRANTY – STAINLESS STEEL COMPONENTS
• TWO (2) YEAR WARRANTY – GAS VALVE, PILOT ASSEMBLY, POWER SUPPLY, CONTROLS
• TWO (2) YEAR WARRANTY – SKYTECH MANUFACTURED OPTIONAL CONTROLS
SANCTUARY SERIES – GFRC FIRE FEATURES
• THREE (3) YEAR WARRANTY – GFRC STRUCTURE
• REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY
WARRANTY COVERS MANUFACTURING DEFECTS OR STRUCTURAL FAILURE. SMALL STRESS CRACKS AND SURFACE CRAZING ARE A NATURAL OCCURRENCE IN GFRC PRODUCTS AND NOT COVERED BY WARRANTY.
READY TO FINISH (RTF) ENCLOSURES
• FRAME – LIFETIME WARRANTY ON CONSTRUCTION AND MANUFACTURER DEFECTS
ACCESSORIES
• LIFETIME WARRANTY – CONSTRUCTION AND MANUFACTURER DEFECTS • LIFETIME WARRANTY – STAINLESS STEEL COMPONENTS (LIDS, STAINLESS STEEL COVERS) • ONE (1) YEAR WARRANTY – ESTOP1-OH, ESTOP2-5H WINDSHIELDS, HOSES AND REGULATORS
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 17
The end-user must provide a bill of sale, canceled check, or payment record to verify the purchase date and to establish the warranty period. This Limited Warranty shall be valid and limited to the original purchaser only.
WARNING: Any modification to the product will void the warranty.
This Limited Warranty shall be limited to the repair and/or replacement of parts that have been proven to be defective under normal use and service. All warranty claims must be made by the OEM/Distributor/Dealer account on behalf of the end-user. You may contact Technical Support at 800-966-8126.
Our Technical Service Department must confirm all approved defects. If a defect is confirmed and we approve the claim, we will replace such parts without charge. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.
The manufacturer may request defective products returned with an RMA (Return Merchandise Authorization) issued by AMD DIRECT for specific products, which is considered to be the nature of the defect and or warranty claim. Product to be returned should; be packed so as not to incur damages during transportation. AMD DIRECT is not responsible for damages on returned items. RMA is valid for thirty (30) days from the date issued. The RMA must be clearly marked on the outside of the package.
Please check with your local building code department or governing agency for proper approvals before purchasing. AMD DIRECTOutdoors is not responsible for any violation of local codes.
Travel, diagnostic cost, service labor to repair the defect on warranty parts to and from the factory will be the responsibility of the owner. We will not be responsible for labor charges and/or damage incurred in installation, repair, and replacement. AMD DIRECT is not responsible for Issues related to gas or electrical installation.
The Limited Warranty is voided if not assembled, installed, and operated as intended. This Limited Warranty does not cover any defects due to accident, abuse, misuse, alteration, misapplication, vandalism, improper installation or improper maintenance or service, removal from the original location, or re- installation into another location, or failure to perform normal and routine maintenance.
Damage due to severe weather conditions such as hail, hurricanes, earthquakes, tornadoes, discoloration due to overheating, exposure to chemicals (including chlorine and salt), either directly or in the atmosphere, or very high humidity, is not covered by this Limited Warranty. Coastal, humid and/or salt environments are subject to manufacturer review. All out-of-box claims must be made within 30 days of purchase and must be made prior to installation. Any product installed damaged will be considered damaged during installation and not covered under warranty.
There are no other express warranties except as set forth herein. For consumer applications, any applicable implied warranties of merchantability and fitness are limited in duration to the period of coverage of this Limited Warranty. Some states do not allow limitation on how long an implied warranty lasts, so this limitation may not apply to you.
For Commercial Applications, the liability of AMD DIRECT is limited to the express terms of this warranty. We expressly disclaim any and all implied warranties, including any warranties of fitness for a particular purpose or merchantability.
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 18
We are not liable for any special, indirect or consequential damages. Our maximum liability is limited to the purchase price of the purchased units. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusion may not apply to you.
We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment, and or such representation are binding.
AMD DIRECT
17322 Gothard St.
Huntington Beach, CA 92647
www.amddirect.com
Phone: 800-966-8126
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 19
Having problems getting the gas appliance to operate?
Don’t leave the job site! We want to help! Call 800.966.8126 for Technical Support between the hours of 8:00AM to 5:00PM PST. BEFORE YOU CALL WE WILL NEED THIS INFORMATION
1. Model Number: ___
2. Serial Number: ___
3. How long is the gas line run? Nat Gas LP Gas 4. What size is gas line? _____
5. Inlet Gas Pressure: _____WC
Manifold Gas Pressure: _____ WC
6. What type of media are you using? __ 7. Review the troubleshooting section in the installation manual. 8. What are the symptoms? Please be prepared to explain. 9. Be prepared to send photos to us when on the phone. 10. Found missing or damaged parts? Let us know ASAP or send photos.
Fire Pits FPSS 3-30-16Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition REV. A Page 20
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>